Utility of a nonlinear joint dynamical framework to model a pair of coupled cardiovascular signals
, Article IEEE Journal of Biomedical and Health Informatics ; Volume 17, Issue 4 , 2013 , Pages 881-890 ; 21682194 (ISSN) ; Shamsollahi, M. B ; Sharif University of Technology
2013
Abstract
We have recently proposed a correlated model to provide a Gaussian mixture representation of the cardiovascular signals, with promising results in identifying rhythm disturbances. The approach provides a transformation of the data into a set of integrable Gaussians distributed over time. Looking into the model from a new joint modeling perspective, it is capable of assembling a filtered estimation, and can be used to derive temporal information of the waveforms. In this paper, we present a step-by-step derivation of the joint model putting correlation assumptions together to conclude a minimal joint description for a pair of ECG-ABP signals. We then probe novel applications of this model,...
Validation of the Saadat NIBP module according to the ANSI/AAMI-SP10 protocol
, Article 2013 20th Iranian Conference on Biomedical Engineering, ICBME 2013 ; Deembec , 2013 , Pages 199-202 ; Mashayekhi, G ; Behzadfar, N ; Yaghoobzadeh, A ; Babaee, T ; Sharif University of Technology
IEEE Computer Society
2013
Abstract
This study is conducted with the aim of validating the Saadat non-invasive blood pressure (NIBP) module accuracy and reliability against direct intra arterial pressure measurement (IBP) according to the ANSI/AAMI SP10-2002 guidelines. Measurement and comparison procedure were done in a static population of 19 adult patients with brachial catheterized arterial line with total measurements of 195 under supervision of a highly experienced cardiovascular anesthesiologist in accordance with the ANSI/AAMI SP10-2002 regulation. Data analysis was performed based on the protocol criteria. In order to represent relationships between the test device and the reference method, Bland-Altman graphical...
Mathematical modeling of heart rate and blood pressure variations due to changes in breathing pattern
, Article 2013 20th Iranian Conference on Biomedical Engineering, ICBME 2013, Tehran, 18 December 2013 through 20 December 2013 ; 2013 , Pages 54-58 ; Zahedi, E ; Sharif University of Technology
IEEE Computer Society
2013
Abstract
Analysis of the heart rate (HR) variation due to respiration, known as respiratory sinus arrhythmia (RSA), is a method to assess the autonomic nervous system (ANS) function. In this paper a physiologically-based mathematical model consisting of the cardiorespiratory system and ANS control has been used in order to study the cardiovascular response (mean arterial blood pressure and HR) to breathing with different respiration rates and tidal volumes. Simulation results show that RSA has its maximal amplitude at the respiration frequency of 0.12 Hz and that RSA amplitude varies linearly by tidal volume. These results are in agreement with real data from the literature. In addition, the...
Introducing an adaptive robust controller for artificial heart
, Article Proceedings of the IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics, 24 June 2012 through 27 June 2012 ; June , 2012 , Pages 413-418 ; 21551774 (ISSN) ; 9781457711992 (ISBN) ; Jahed, M ; Sharif University of Technology
2012
Abstract
Prolonged and uncontrolled high shear stresses and turbulence can cause hemolysis, while alternating and low-level stresses may contribute to platelet activation and thrombus formation. Such deficiencies are reported for Total Artificial Heart (TAH) systems which are generally not fully capable of dynamic adaptation to sudden pressure and volume changes. This study introduces an adaptive robust controller for a linear motor based TAH (LMTAH) which overcomes such shortcomings. Proposed controller performance is compared with simulated natural heart in normal and stressed physiological conditions. Application of adaptive robust control results in flows with less stress variation and...
Life-threatening arrhythmia verification in ICU patients using the joint cardiovascular dynamical model and a bayesian filter
, Article IEEE Transactions on Biomedical Engineering ; Volume 58, Issue 10 PART 1 , 2011 , Pages 2748-2757 ; 00189294 (ISSN) ; Shamsollahi, M. B ; Sharif University of Technology
Abstract
In this paper, a novel nonlinear joint dynamical model is presented, which is based on a set of coupled ordinary differential equations of motion and a Gaussian mixture model representation of pulsatile cardiovascular (CV) signals. In the proposed framework, the joint interdependences of CV signals are incorporated by assuming a unique angular frequency that controls the limit cycle of the heart rate. Moreover, the time consequence of CV signals is controlled by the same phase parameter that results in the space dimensionality reduction. These joint equations together with linear assignments to observation are further used in the Kalman filter structure for estimation and tracking. Moreover,...
Prediction of acute hypotension episodes using Logistic Regression model and Support Vector Machine: A comparative study
, Article 2011 19th Iranian Conference on Electrical Engineering, ICEE 2011, 17 May 2011 through 19 May 2011 ; May , 2011 , Page(s): 1 - 4 ; ISSN :21647054 ; 9789644634284 (ISBN) ; Arasteh, A ; Moradi, M. H ; Sharif University of Technology
2011
Abstract
Acute hypotension episodes are one of the hemodynamic instabilities with high mortality rate that is frequent among many groups of patients. Prediction of acute hypotension episodes can help clinicians to diagnose the cause of this physiological disorder and select proper treatment based on this diagnosis. In this study new physiological time series are generated based on heart rate, systolic blood pressure, diastolic blood pressure and mean blood pressure time series. Statistical features of these time series are extracted and patients whom are exposed to acute hypotension episodes in future 1 hour time interval and whom are not, are classified based on these features and with the aid of...
Modeling Brachial Blood Pressure by Using Finger PPG Signal
, M.Sc. Thesis Sharif University of Technology ; Zahedi, Edmond (Supervisor)
Abstract
Nowadays, all of the devices that measure blood pressure commercially at home are using wrist or arm cuffs preventing the systolic or diastolic blood pressure from being measured continuously. Various parameters such as blood flow with some degree of correlation with blood pressure that can be measured noninvasively have been suggested. However, these parameters do not produce accurate estimates for blood pressure. Pulse Transit Time (PTT) which is defined as the interval between the R peak of ECG signal and the next PPG signal valley has shown to have over 90% correlation with systolic blood pressure in past studies. In this thesis, the relationship between the value of the systolic blood...
Blood Pressure Measurement by using Pulse Transit Time
, M.Sc. Thesis Sharif University of Technology ; Zahedi, Edmond (Supervisor) ; Jahed, Mehran (Supervisor)
Abstract
Continuous and non-invasive blood pressure (BP) measurement systems generally utilize applanation tonometry and vascular unloading. Some of them satisfies the AAMI standards (|mean|<5, |SD|<8). Unfortunately they are hardly to be widely affordable due to the complicated mechanical structure and high production cost. Till now those devices are seldom being used in operation room and generally used in clinical researches. In 2000, a linear model using pulse transit time (PTT) to continuous and non-invasive blood pressure (BP) measurement was proposed. Due to the nonlinear performance parameters of the arteries, researchers have used nonlinear models to promote this method. Although the...
Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time
, Article Proceedings - IEEE International Symposium on Circuits and Systems, 24 May 2015 through 27 May 2015 ; Volume 2015-July , 2015 , Pages 1006-1009 ; 02714310 (ISSN) ; 9781479983919 (ISBN) ; Kiani, M.M ; Mohammadzade, H ; Shabany, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2015
Abstract
Recently a few methods have been proposed in the literature for non-invasive cuff-less estimation of systolic and diastolic blood pressures. One of the most prominent methods is to use the Pulse Transit Time (PTT). Although it is proven that PTT has a strong correlation with the systolic and diastolic blood pressures, this relation is highly dependent to each individuals physiological properties. Therefore, it requires per person calibration for accurate and reliable blood pressure estimation from PTT, which is a big drawback. To alleviate this issue, in this paper, a novel method is proposed for accurate and reliable estimation of blood pressure that is calibration-free. This goal is...
Definition and comparison of a new vascular index between young healthy and aged subjects
, Article IECBES 2014, Conference Proceedings - 2014 IEEE Conference on Biomedical Engineering and Sciences: "Miri, Where Engineering in Medicine and Biology and Humanity Meet", 8 December 2014 through 10 December 2014 ; 2015 , Pages 911-915 ; 9781479940844 (ISBN) ; Zahedi, E ; Mohd Ali, M. A ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2015
Abstract
In an effort to identify a useful noninvasive screening tool for cardiovascular diseases (CVD) screening, photoplethysmograph (PPG) signals were acquired and analyzed. These PPG signals were recorded during reactive hyperemia experiments consisting of a 4-minute blood flow blockage of the right arm (RA) brachial artery (BA) using a blood pressure cuff inflator. This procedure is usually done for the assessment of endothelial dysfunction which is a risk factor for developing CVD. In this study, signals of the infrared (IR) and red (R) LED's of the PPG sensor were analyzed. These signals were preprocessed, normalized and slow varying component of the signal (DC values) and the pulsatile...
Experimental feasibility study of estimation of the normalized central blood pressure waveform from radial photoplethysmogram
, Article Journal of Healthcare Engineering ; Volume 6, Issue 1 , 2015 , Pages 121-144 ; 20402295 (ISSN) ; Sohani, V ; Mohd. Ali, M. A ; Chellappan, K ; Beng, G. K ; Sharif University of Technology
Multi-Science Publishing Co. Ltd
2015
Abstract
The feasibility of a novel system to reliably estimate the normalized central blood pressure (CBPN ) from the radial photoplethysmogram (PPG) is investigated. Right-wrist radial blood pressure and left-wrist PPG were simultaneously recorded in five different days. An industry-standard applanation tonometer was employed for recording radial blood pressure. The CBP waveform was amplitude-normalized to determine CBPN . A total of fifteen second-order autoregressive models with exogenous input were investigated using system identification techniques. Among these 15 models, the model producing the lowest coefficient of variation (CV) of the fitness during the five days was...
A combined dynamical sequential network for generating coupled cardiovascular signals with different beat types
, Article ; 2010 3rd International Symposium on Applied Sciences in Biomedical and Communication Technologies, ISABEL 2010, 7 November 2010 through 10 November 2010 , 2010 ; 9781424481323 (ISBN) ; Shamsollahi, M. B ; Sharif University of Technology
Abstract
We present generalizations of the previously published artificial models for generating abnormal cardiac rhythms to provide simulations of coupled cardiovascular (CV) signals with different beat morphologies. Using a joint dynamical formulation, we generate the normal morphologies of the cardiac cycle using a sum of Gaussian kernels, fitted to real CV recordings. The joint inter-dependencies of CV signals are introduced by assuming the same angular frequency and a phase coupling. Abnormal beats are then specified as new dynamical trajectories. An ergadic first-order Markov chain is also used for switching between normal and abnormal beat types. Probability transitions can be learned from...
Mathematical modeling of CSF pulsatile hydrodynamics based on fluid-solid interaction
, Article IEEE Transactions on Biomedical Engineering ; Volume 57, Issue 6 , 2010 , Pages 1255-1263 ; 00189294 (ISSN) ; Bastani, D ; Najarian, S ; Ganji, F ; Farmanzad, F ; Seddighi, A. S ; Sharif University of Technology
2010
Abstract
Intracranial pressure (ICP) is derived from cerebral blood pressure and cerebrospinal fluid (CSF) circulatory dynamics and can be affected in the course of many diseases. Computer analysis of the ICP time pattern plays a crucial role in the diagnosis and treatment of those diseases. This study proposes the application of Linninger et al.s [IEEE Trans. Biomed. Eng. , vol. 52, no. 4, pp. 557565, Apr. 2005] fluidsolid interaction model of CSF hydrodynamic in ventricular system based on our clinical data from a group of patients with brain parenchyma tumor. The clinical experiments include the arterial blood pressure (ABP), venous blood pressure, and ICP in the subarachnoid space (SAS). These...
Parameter estimation of a mathematical model describing the cardiovascular-respiratory interaction
, Article Computing in Cardiology, 6 September 2015 through 9 September 2015 ; Volume 42 , 2015 , Pages 617-620 ; 23258861 (ISSN) ; 9781509006854 (ISBN) ; Hidalgo Muñoz, A. R ; Zarzoso, V ; Zahedi, E ; Murray A ; Sharif University of Technology
IEEE Computer Society
2015
Abstract
Short-term interaction between heart rate (HR) and physiological measures like blood pressure and respiration reveals relevant information about autonomic nervous system (ANS) function. Complex mathematical models for describing their couplings have been proposed in the literature. However, an accurate estimation of their parameters in an inverse modeling problem is crucial to extract reliable ANS related indices. This study considers a physiologically-based model of the cardiovascular-respiratory system and ANS control that presents the neural and mechanical effects of respiration separately. The estimation method is evaluated on synthetic signals. An accurate estimation of the...
Robust control of LVAD based on the sub-regional modeling of the heart
, Article Scientia Iranica ; Volume 23, Issue 6 , 2016 , Pages 2934-2943 ; 10263098 (ISSN) ; Jahed, M ; Sharif University of Technology
Sharif University of Technology
2016
Abstract
Left Ventricular Assist Devices (LVAD) have received renewed interest as a bridge-to-transplantation as well as a bridge-to-recovery device. Ironically, reports of malfunction and complications have hindered the growth of this device. In particular, the main concern is LVAD's susceptibility to excessive backlash and suction as a result of ows that are either too low or high, respectively. This study utilizes a well-established physiological model of the cardiovascular system as a reliable platform to study a proposed adaptive robust controller for a rotary motor based LVAD which overcomes such shortcomings. Proposed controller performance is evaluated by comparing simulated natural heart...
Non-invasive and Continuous Blood Pressure Measurement Using Pulse Transit Time without Cuff Requirement
, M.Sc. Thesis Sharif University of Technology ; Shabany, Mahdi (Supervisor)
Abstract
This thesis addresses cuff-less blood pressure (BP) estimation, for systolic blood pressure (SBP) and diastolic blood pressure (DBP) estimation with the aid of the processing of vital signals. Both with and without calibration per person approaches for BP estimation are considered. A data acquisition hardware is designed for high-resolution sampling of phonocardiogram (PCG), Photoplethysmogram (PPG) and electrocardiogram (ECG). Using these signals, pulse transit time (PTT) and pulse arrival time (PAT) indexes, which would be used for BP estimation with calibration, are extracted. For the BP estimator model using the calibration, A nonlinear model based on PTT or PAT, via modeling the vessels...
Design of Efficient Algorithms for Cuff-less and Continuous Estimation of Blood Pressure in Smart Mobile Healthcare Systems
, M.Sc. Thesis Sharif University of Technology ; Shabany, Mahdi (Supervisor) ; Mohammadzadeh, Hoda (Co-Advisor)
Abstract
Continuous Blood Pressure monitoring can provide invaluable information about individuals’ health conditions. However, BP is conventionally measured using inconvenient cuff-based instruments, which prevents continuous BP monitoring. This work presents an efficient algorithm, based on the Pulse Arrival Time (PAT), for the continuous and cuff-less estimation of the Systolic Blood Pressure (SBP), Diastolic Blood Pressure (DBP), and Mean Arterial Pressure (MAP) values. The proposed framework estimates the BP values through processing vital signals and extracting two types of features, which are based on either physiological parameters or whole-based representation of vital signals. Finally, the...
Hardware Implementation of Wearable Cuff-less Blood Pressure Monitoring Module
,
M.Sc. Thesis
Sharif University of Technology
;
Shabany, Mahdi
(Supervisor)
;
Mohammadzade, Hoda
(Supervisor)
Abstract
Hypertension precvalence is 24 and 20.5 percent in men and women, respectively. Continuous Blood Pressure monitoring can provide invaluable information about individuals’ health conditions. However, BP is conventionally measured using inconvenient cuff-based instruments, which prevents continuous BP monitoring. This work presents an efficient algorithm, based on the Pulse Arrival Time (PAT), extracted from Electrocardiogram (ECG) and Photopletysmograph (PPG), for the continuous and cuff-less estimation of the Systolic Blood Pressure (SBP), Diastolic Blood Pressure (DBP), and Mean Arterial Pressure (MAP) values. Methods: The proposed framework estimates the BP values through processing vital...
Nonlinear cuffless blood pressure estimation of healthy subjects using pulse transit time and arrival time
, Article IEEE Transactions on Instrumentation and Measurement ; Volume 66, Issue 12 , 2017 , Pages 3299-3308 ; 00189456 (ISSN) ; Kachuee, M ; Shabany, M ; Sharif University of Technology
Abstract
This paper presents a novel blood pressure (BP) estimation method based on pulse transit time (PTT) and pulse arrival time (PAT) to estimate the systolic BP (SBP) and the diastolic BP (DBP). A data acquisition hardware is designed for high-resolution sampling of phonocardiogram (PCG), photoplethysmogram, and electrocardiogram (ECG). PCG and ECG perform as the proximal timing reference to obtain PTT and PAT indices, respectively. In order to derive a BP estimator model, a calibration procedure, including a supervised physical exercise, is conducted for each individual, which causes changes in their BP, and then, a number of reference BPs are measured alongside the acquisition of the signals...
A multiscale approach for determining the morphology of endothelial cells at a coronary artery
, Article International Journal for Numerical Methods in Biomedical Engineering ; Volume 33, Issue 12 , 2017 ; 20407939 (ISSN) ; Saidi, M. S ; Firoozabadi, B ; Sharif University of Technology
Abstract
The morphology of endothelial cells (ECs) may be an indication for determining atheroprone sites. Until now, there has been no clinical imaging technique to visualize the morphology of ECs in the arteries. The present study introduces a computational technique for determining the morphology of ECs. This technique is a multiscale simulation consisting of the artery scale and the cell scale. The artery scale is a fluid-structure interaction simulation. The input for the artery scale is the geometry of the coronary artery, that is, the dynamic curvature of the artery due to the cardiac motion, blood flow, blood pressure, heart rate, and the mechanical properties of the blood and the arterial...