Loading...
Search for: blood-pressure-measurement
0.006 seconds

    Blood Pressure Measurement by using Pulse Transit Time

    , M.Sc. Thesis Sharif University of Technology Mazaheri, Samaneh (Author) ; Zahedi, Edmond (Supervisor) ; Jahed, Mehran (Supervisor)
    Abstract
    Continuous and non-invasive blood pressure (BP) measurement systems generally utilize applanation tonometry and vascular unloading. Some of them satisfies the AAMI standards (|mean|<5, |SD|<8). Unfortunately they are hardly to be widely affordable due to the complicated mechanical structure and high production cost. Till now those devices are seldom being used in operation room and generally used in clinical researches. In 2000, a linear model using pulse transit time (PTT) to continuous and non-invasive blood pressure (BP) measurement was proposed. Due to the nonlinear performance parameters of the arteries, researchers have used nonlinear models to promote this method. Although the... 

    Design and Implementation of Non-Invasive Blood Pressure Monitor for Smart Health Application

    , M.Sc. Thesis Sharif University of Technology Amini, Alireza (Author) ; Fakharzadeh Jahromi, Mohammad (Supervisor)
    Abstract
    The blood pressure (BP) is one of the most vital signs to monitor human health. Hypertension is a major public health problem that is associated with morbidity and mortality. In the past decades, the number of people with hypertension disease has been increased. According to Ministry of Health, 54 percent of hypertensive patients are unaware of this health threat. Therefore, accurate and continuous measurement of BP is essential for its prevention and treatment. Traditional non-invasive methods of BP monitoring use an inflatable cuff, which causes discomfort due to occlusion of the artery and can not be used continuously. Numerous studies have attempted to present methods without using a... 

    Experimental feasibility study of estimation of the normalized central blood pressure waveform from radial photoplethysmogram

    , Article Journal of Healthcare Engineering ; Volume 6, Issue 1 , 2015 , Pages 121-144 ; 20402295 (ISSN) Zahedi, E ; Sohani, V ; Mohd. Ali, M. A ; Chellappan, K ; Beng, G. K ; Sharif University of Technology
    Multi-Science Publishing Co. Ltd  2015
    Abstract
    The feasibility of a novel system to reliably estimate the normalized central blood pressure (CBPN) from the radial photoplethysmogram (PPG) is investigated. Right-wrist radial blood pressure and left-wrist PPG were simultaneously recorded in five different days. An industry-standard applanation tonometer was employed for recording radial blood pressure. The CBP waveform was amplitude-normalized to determine CBPN. A total of fifteen second-order autoregressive models with exogenous input were investigated using system identification techniques. Among these 15 models, the model producing the lowest coefficient of variation (CV) of the fitness during the five days was... 

    Cuffless blood pressure estimation algorithms for continuous health-care monitoring

    , Article IEEE Transactions on Biomedical Engineering ; Volume 64, Issue 4 , 2017 , Pages 859-869 ; 00189294 (ISSN) Kachuee, M ; Kiani, M. M ; Mohammadzade, H ; Shabany, M ; Sharif University of Technology
    IEEE Computer Society  2017
    Abstract
    Goal: Continuous blood pressure (BP) monitoring can provide invaluable information about individuals' health conditions. However, BP is conventionally measured using inconvenient cuff-based instruments, which prevents continuous BP monitoring. This paper presents an efficient algorithm, based on the pulse arrival time (PAT), for the continuous and cuffless estimation of the systolic BP, diastolic blood pressure (DBP), and mean arterial pressure (MAP) values. Methods: The proposed framework estimates the BP values through processing vital signals and extracting two types of features, which are based on either physiological parameters or whole-based representation of vital signals. Finally,...