Loading...
Search for: calibration-curves
0.003 seconds
Total 35 records

    Design and Construction of a Density Prob with Experimental Measurments

    , M.Sc. Thesis Sharif University of Technology Rafizade, Abolfazl (Author) ; Sohrabpour, Mostafa (Supervisor)
    Abstract
    In this project a dual density logging tool has been designed and constructed for measuring the bulk density of a formation using gamma rays. One of the main applications of this tool is obtaining porosity. It also is useful in the detection of formations containing oil and gas. In this work, MCNP Monte Carlo code was used to simulate the performance of the scattered gamma rays under various sond-formation parametric condition. The results coming from this code are applied to determine the fundamental parameters of gamma-gamma density tools like, Energy window, thickness of lead, optimum distance between each detectors. Furthermore, a novel method based on summation of back scatter and... 

    Design and Construction of a Densitometer Tool and Simulation of its Performance by the Mcnp Code and Comparison of the Obtained Data with Experimental Results

    , M.Sc. Thesis Sharif University of Technology Shabani, Ali (Author) ; Sohrabpour, Mostafa (Supervisor)
    Abstract
    In this Thesis, a nuclear borehole logging tool has been designed and constructed for measuring the bulk density of a formation by the use of gamma rays. One of the main applications of this tool is obtaining of porosity. It also is useful in the detection of formations containing oil and gas. This tool consists of: a gamma ray source 60Co, a single gamma ray detector NaI(Tl), lead shield and electronic modules. The cylindrical sond is entered into a borehole and the surrounding formation is subjected to the emitted gamma rays from the source. The formation density can be determined from the measurement of the scattered photons reaching the detector from the formation. The purpose of the... 

    A sensitive and selective colorimetric method for detection of copper ions based on anti-aggregation of unmodified gold nanoparticles

    , Article Talanta ; Vol. 129, issue , 2014 , pp. 227-232 ; ISSN: 00399140 Hormozi-Nezhad, M. R ; Abbasi-Moayed, S ; Sharif University of Technology
    Abstract
    A highly sensitive and selective colorimetric method for detection of copper ions, based on anti-aggregation of D-penicillamine (D-PC) induced aggregated gold nanoparticles (AuNPs) was developed. Copper ions can hinder the aggregation of AuNPs induced by D-PC, through formation of mixed-valence complex with D-PC that is a selective copper chelator. In the presence of a fixed amount of D-PC, the aggregation of AuNPs decreases with increasing concentrations of Cu2+ along with a color change from blue to red in AuNPs solution and an increase in the absorption ratio (A520/A 650). Under the optimum experimental conditions (pH 7, [AuNPs] =3.0 nmol L-1 and [NaCl]=25 mmol L-1), a linear calibration... 

    Voltammetric monitoring of Cd (II) by nano-TiO2 modified carbon paste electrode sensitized using 1,2-bis-[o-aminophenyl thio] ethane as a new ion receptor

    , Article Sensors and Actuators, B: Chemical ; Vol. 192 , 2014 , pp. 648-657 ; ISSN: 09254005 Ramezani, S ; Ghobadi, M ; Bideh, B. N ; Sharif University of Technology
    Abstract
    The objective of the work ahead is presentation of a new carbon paste electrode (CPE) modified by TiO2 nanoparticles (TiO2NPs) and 1,2-bis-[o-aminophenyl thio] ethane (APTE) ligand as a selective cation receptor for determination of the Cd (II) ions using differential pulse anodic stripping voltammetry (DPASV). The electrode shows an excellent tendency to Cd (II) ions in presence of some interfering species. Under the optimum conditions, a linear calibration curve was obtained in the concentration range of 2.9 nM to 4.6 μM with a correlation coefficient of 0.9969 in the anodic potential of 0.54 (V vs. Ag/AgCl). The metal detection limit was 2.0 nM after 10 min preconcentration (S/N = 3). The... 

    A horizontally oriented setup for liquid-liquid-liquid microextraction of estrogens

    , Article Analytical Methods ; Volume 5, Issue 22 , 2013 , Pages 6517-6522 ; 17599660 (ISSN) Bagheri, H ; Maleki, H ; Es'Haghi, A ; Sharif University of Technology
    2013
    Abstract
    A horizontally oriented liquid-liquid-liquid microextraction (HOLLLME) setup was developed and applied for the isolation of two major estrogens from aquatic media. In contrast to the conventional procedure, in this setup the extracting microdrop was suspended from a horizontally positioned needle in order to provide much higher stability to the extracting phase. The developed HOLLLME approach was applied to isolate two major selected estrogens from aquatic media followed by high performance liquid chromatography-ultraviolet (HPLC-UV) determination. Estrogens were, initially, extracted from water samples into hexane and subsequently, the back extraction stage was performed with 6 μL of sodium... 

    Using three different optical fiber designs to study humidity effect on the air refractive index

    , Article Optics and Lasers in Engineering ; Volume 50, Issue 11 , November , 2012 , Pages 1495-1500 ; 01438166 (ISSN) Golnabi, H ; Sharif University of Technology
    2012
    Abstract
    Design and operation of three different optical designs based on the light intensity modulation for investigation of the humidity effects on the air index of refraction are described. The measurement variable is the transmitted power, which depends on the refractive index of the medium in the path of a fiber-to-fiber optical design. Three different probes (probe #1, #2, and #3) are tested in which probe #1 and probe #2 can also check the presence of water or any other transparent liquid in the gap between the two axial fibers. Performances of the new systems are tested as a refractive index monitoring mean and experimental results are given. The variations of the modulated powers as... 

    Spectrophotometric determination of glutathione and cysteine based on aggregation of colloidal gold nanoparticles

    , Article Scientia Iranica ; Volume 19, Issue 3 , June , 2012 , Pages 958-963 ; 10263098 (ISSN) Hormozi Nezhad, M. R ; Seyedhosseini, E ; Robatjazi, H ; Sharif University of Technology
    2012
    Abstract
    We report herein the development of a highly sensitive colorimetric method for the determination of cysteine and glutathione, based on aggregation of the citrate capped gold nanoparticles (Au NPs). This was exploited from high affinity of low-molecular-weight aminothiols towards the Au NPs surface, which could induce displacement of the citrate shell by the thiolate shell of target molecules, resulting in aggregation of the NPs through intermolecular electrostatic interaction or hydrogen-bonding. As a result of aggregation, which can be affected by the ionic strength, pH and concentration of Au NPs, the plasmon band at around 521 nm decreases gradually, along with formation of a new red... 

    Electrochemical determinations of 6-mercaptopurine on the surface of a carbon nanotube-paste electrode modified with a cobalt salophen complex

    , Article Journal of Solid State Electrochemistry ; Volume 16, Issue 4 , April , 2012 , Pages 1643-1650 ; 14328488 (ISSN) Shahrokhian, S ; Ghorbani Bidkorbeh, F ; Mohammadi, A ; Dinarvand, R ; Sharif University of Technology
    2012
    Abstract
    A mixture of multi-walled carbon nanotube/graphite paste electrode modified with a salophen complex of cobalt was prepared and was applied for the study of the electrochemical behavior of 6-mercaptopurine (MP) using cyclic and differential pulse voltammetry (DPV). An excellent electrocatalytic activity toward the oxidation of MP was achieved, which led to a considerable lowering in the anodic overpotential and remarkable increase in the response sensitivity in comparison with unmodified electrode. Utilizing DPV method, a linear dynamic range of 1-100 μM with detection limit of 0.1 μM was obtained in phosphate buffer of pH 3.0. The electrochemical detection system was very stable, and the... 

    Novel polyamide-based nanofibers prepared by electrospinning technique for headspace solid-phase microextraction of phenol and chlorophenols from environmental samples

    , Article Analytica Chimica Acta ; Volume 716 , 2012 , Pages 34-39 ; 00032670 (ISSN) Bagheri, H ; Aghakhani, A ; Baghernejad, M ; Akbarinejad, A ; Sharif University of Technology
    2012
    Abstract
    A novel solid phase microextraction (SPME) fiber was fabricated by electrospinning method in which a polymeric solution was converted to nanofibers using high voltages. A thin stainless steel wire was coated by the network of polymeric nanofibers. The polymeric nanofiber coating on the wire was mechanically stable due to the fine and continuous nanofibers formation around the wire with a three dimensional structure. Polyamide (nylon 6), due to its suitable characteristics was used to prepare the unbreakable SPME nanofiber. The scanning electron microscopy (SEM) images of this new coating showed a diameter range of 100-200nm for polyamide nanofibers with a homogeneous and porous surface... 

    Polyaniline-nylon-6 electrospun nanofibers for headspace adsorptive microextraction

    , Article Analytica Chimica Acta ; Volume 713 , 2012 , Pages 63-69 ; 00032670 (ISSN) Bagheri, H ; Aghakhani, A ; Sharif University of Technology
    2012
    Abstract
    A headspace adsorptive microextraction technique was developed using a novel polyaniline-nylon-6 (PANI-N6) nanofiber sheet, fabricated by electrospinning. The homogeneity and the porosity of the prepared PANI-N6 sheet were studied using the scanning electron microscopy (SEM) and nanofibers diameters were found to be around 200nm. The novel nanofiber sheet was examined as an extracting medium to isolate some selected chlorobenzenes (CBs), as model compounds, from aquatic media. The extracted analytes were desorbed using μL-amounts of solvent and eventually an aliquot of extractant was injected into gas chromatography-mass spectrometry (GC-MS). Various parameters affecting the extraction and... 

    Mediator-less highly sensitive voltammetric detection of glutamate using glutamate dehydrogenase/vertically aligned CNTs grown on silicon substrate

    , Article Biosensors and Bioelectronics ; Volume 31, Issue 1 , 2012 , Pages 110-115 ; 09565663 (ISSN) Gholizadeh, A ; Shahrokhian, S ; Iraji zad, A ; Mohajerzadeh, S ; Vosoughi, M ; Darbari, S ; Sanaee, Z ; Sharif University of Technology
    Abstract
    A sensitive glutamate biosensor is prepared based on glutamate dehydrogenase/vertically aligned carbon nanotubes (GLDH, VACNTs). Vertically aligned carbon nanotubes were grown on a silicon substrate by direct current plasma enhanced chemical vapor deposition (DC-PECVD) method. The electrochemical behavior of the synthesized VACNTs was investigated by cyclic voltammetry and electrochemical impedance spectroscopic methods. Glutamate dehydrogenase covalently attached on tip of VACNTs. The electrochemical performance of the electrode for detection of glutamate was investigated by cyclic and differential pulse voltammetry. Differential pulse voltammetric determinations of glutamate are performed... 

    Resolution and quantification of complex mixtures of polycyclic aromatic hydrocarbons in heavy fuel oil sample by means of GC × GC-TOFMS combined to multivariate curve resolution

    , Article Analytical Chemistry ; Volume 83, Issue 24 , 2011 , Pages 9289-9297 ; 00032700 (ISSN) Parastar, H ; Radović, J. R ; Jalali-Heravi, M ; Diez, S ; Bayona, J. M ; Tauler, R ; Sharif University of Technology
    Abstract
    Comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOFMS) combined to multivariate curve resolution-alternating least-squares (MCR-ALS) is proposed for the resolution and quantification of very complex mixtures of compounds such as polycyclic aromatic hydrocarbons (PAHs) in heavy fuel oil (HFO). Different GC × GC-TOFMS data slices acquired during the analysis of HFO samples and PAH standards were simultaneously analyzed using the MCR-ALS method to resolve the pure component elution profiles in the two chromatographic dimensions as well as their pure mass spectra. Outstandingly, retention time shifts within and between GC × GC runs were not affecting... 

    Experimental investigation of constant and concentration-dependent diffusivity of a hydrocarbon solvents-heavy oil system: A comparative study

    , Article Energy Sources, Part A: Recovery, Utilization and Environmental Effects ; Volume 34, Issue 3 , 2011 , Pages 235-245 ; 15567036 (ISSN) Nasirahmadi, E ; Kharrat, R ; Ghazanfari, M. H ; Rashtchian, D ; Sharif University of Technology
    Abstract
    This work is concerned with the experimental investigation of mass transfer, which occurs during diffusion of hydrocarbon solvents in heavy oil based on constant and concentration-dependent diffusion coefficient. Here, a series of free fall diffusion experiments have been conducted in sealed test tubes at fixed temperatures. Pentane, hexane, and octane were used as solvents and were placed on heavy oil in tubes. The diffusivity of heavy oil into solvents was monitored by a digital camera. The image analysis technique was applied to extract concentration profiles in diffusion zones of solvents by means of calibration curves. Fick's second law was used to obtain both constant and... 

    Investigation of humidity effect on the air refractive index using an optical fiber design

    , Article Journal of Applied Sciences ; Volume 11, Issue 16 , 2011 , Pages 3022-3027 ; 18125654 (ISSN) Mehrabani, A ; Golnabi, H ; Sharif University of Technology
    2011
    Abstract
    In this study operation of an optical design based on the intensity modulation for the refractive index change has been described. The reported instrument measures the transmitted output power depending up on the medium refractive index in the light path of a fiber-to-fiber design. A liquid cell is located between the fibers in the light path and power variations for different cold and hot water levels in the cell are measured. By using a reference humidity meter the calibration curve representing the relative humidity (%RH) as a function of the transmitted output power is obtained. For the hot water with the final temperature of T = 32.7°C the output power range of 255.0 -313.OnW is... 

    Synthesis and characterisation of nanosized TiO2-ZrO2 binary system prepared by an aqueous sol-gel process: Physical and sensing properties

    , Article Sensors and Actuators, B: Chemical ; Volume 155, Issue 2 , July , 2011 , Pages 568-576 ; 09254005 (ISSN) Mohammadi, M. R ; Fray, D. J ; Sharif University of Technology
    2011
    Abstract
    Nanostructured TiO2-ZrO2 thin films and powders were prepared by a straightforward aqueous particulate sol-gel route. Titanium (IV) isopropoxide and zirconium (IV) acetate hydrate were used as precursors, and hydroxypropyl cellulose was used as a polymeric fugitive agent in order to increase the specific surface area. X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy revealed that the powder were crystallised at the low temperature of 500 °C, containing anatase-TiO 2 and tetragonal-ZrO2 phases. Furthermore, it was found that ZrO2 retarded the anatase-to-rutile transformation up to 900 °C. The activation energies for crystallite growth of TiO2 and ZrO2 components in... 

    Novel nanofiber coatings prepared by electrospinning technique for headspace solid-phase microextraction of chlorobenzenes from environmental samples

    , Article Analytical Methods ; Volume 3, Issue 6 , Apr , 2011 , Pages 1284-1289 ; 17599660 (ISSN) Bagheri, H ; Aghakhani, A ; Sharif University of Technology
    2011
    Abstract
    Novel unbreakable solid phase microextraction (SPME) fiber coatings were fabricated by electrospinning method in which the polymeric solution was converted to nanofibers using high voltages. Four different polymers, polyurethane (PU), polycarbonate (PC), polyamide (PA) and polyvinyl chloride (PVC) were prepared as the fiber coatings on thin stainless steel wires. The extraction efficiencies of new coatings were investigated by headspace solid-phase microextraction (HS-SPME) of some environmentally important chlorobenzenes from aqueous samples followed by gas chromatography-mass spectrometry (GC-MS) analysis. Among them, PU showed a prominent efficiency. Effects of coating time and polymer... 

    Simultaneously synthesis and encapsulation of metallic nanoparticles using linear-dendritic block copolymers of poly (ethylene glycol)-poly (citric acid)

    , Article Key Engineering Materials, 8 July 2010 through 9 July 2010 ; Volume 478 , July , 2011 , Pages 7-12 ; 10139826 (ISSN) ; 9783037851357 (ISBN) Naeini, A. T ; Vossoughi, M ; Adeli, M ; Sharif University of Technology
    2011
    Abstract
    Linear-dendritic triblock copolymers of linear poly(ethylene glycol) and hyperbranched poly(citric acid) (PCA-PEG-PCA) were used as the reducing and capping agents to encapsulate gold and silver nanoparticles (AuNPs and AgNPs). PCA-PEG-PCA copolymers in four different molecular weights were synthesized using 2, 5, 10 and 20 citric acid/PEG molar ratios and were called A 1, A 2, A 3 and A 4, respectively. Nanoparticles were encapsulated simultaneously during the preparation process. AuNPs were simply synthesized and encapsulated by addition a boiling aqueous solution of HAuCl 4 to aqueous solutions of A 1, A 2, A 3 and A 4. In the case of silver, an aqueous solution of AgNO 3 was reduced... 

    Colorimetric detection of glutathione based on transverse overgrowth of high aspect ratio gold nanorods investigated by MCR-ALS

    , Article RSC Advances ; Volume 5, Issue 101 , 2015 , Pages 82906-82915 ; 20462069 (ISSN) Fahimi Kashani, N ; Shadabipour, P ; Hormozi-Nezhad, M. R ; Sharif University of Technology
    Royal Society of Chemistry  2015
    Abstract
    In this paper, we present a simple platform for colorimetric detection of glutathione using gold nanorods (AR ∼ 6.5 ± 0.2) as a plasmonic sensor. The functional mechanism of the sensor is based on shifts of longitudinal plasmon resonance during selective transverse overgrowth induced by preferential binding of glutathione at the nanorod tips. Under the optimum conditions, a calibration curve showed two linear regimes at the range of 50 nM to 20 μM of glutathione with a detection limit as low as 40 nM. The nanosensor maintains relatively high selectivity for determination of glutathione in the presence of several other amino acids. However, cysteine at similar concentration levels strongly... 

    An ultrasensitive and selective turn-off fluorescent nanoprobe for the detection of copper ions

    , Article Analytical Methods ; Volume 7, Issue 12 , 2015 , Pages 5067-5073 ; 17599660 (ISSN) Hormozi Nezhad, M. R ; Taghipour, M ; Sharif University of Technology
    Royal Society of Chemistry  2015
    Abstract
    In this study, a novel approach for sensitive and extremely selective detection of copper ions has been developed based on fluorescence resonance energy transfer (FRET) between AuNPs as an acceptor and fluorescein isothiocyanate (FITC) as a donor. Initially, the fluorescence of the FITC molecule turns-off due to adsorption to the AuNPs surface. However, the fluorescence of the FITC-AuNPs system was switched to turn-on by adding d-Pencillamine (d-PC) to the solution mixtures as FITC molecules are released upon displacement by d-PC on the NPs surface. The higher affinity of d-PC toward the surface of AuNPs was further evidenced by controlling the fluorescence intensity enhancement of the... 

    Resorcinol-formaldehyde xerogel as a micro-solid-phase extraction sorbent for the determination of herbicides in aquatic environmental samples

    , Article Journal of Separation Science ; Volume 38, Issue 13 , 2015 , Pages 2305-2311 ; 16159306 (ISSN) Es Haghi, A ; Zare, M ; Piri Moghadam, H ; Bagheri, H ; Sharif University of Technology
    Abstract
    In this study, organic aerogels were synthesized by the sol-gel polycondensation of mixed cresol with formaldehyde in a slightly basic aqueous solution. Carbon aerogels and xerogels are generated by pyrolysis of organic aerogels. The novel sol-gel-based micro-solid-phase extraction sorbent, resorcinol-formaldehyde xerogel, was employed for preconcentration of some selected herbicides. Three herbicides of the aryloxyphenoxypropionate group, clodinafop-propargyl, haloxyfop-etotyl, and fenoxaprop-P-ethyl, were extracted from aqueous samples by micro-solid-phase extraction and subsequently determined by gas chromatography with mass spectrometry. The effect of different parameters influencing the...