Loading...
Search for: chemometric-analysis
0.011 seconds

    Second-order calibration for simultaneous determination of pharmaceuticals in water samples by solid-phase extraction and fast high-performance liquid chromatography with diode array detector

    , Article Chemometrics and Intelligent Laboratory Systems ; Vol. 137, issue , 2014 , pp. 146-154 ; ISSN: 01697439 Akvan, N ; Parastar, H ; Sharif University of Technology
    Abstract
    A fast high-performance liquid chromatography-diode array detection (HPLC-DAD) approach combined to solid phase extraction (SPE) as a pre-concentration step is developed for simultaneous determination of five selected pharmaceuticals (carbamazepine, naproxen, diclofenac, gemfibrozil and mefenamic acid) in water samples. The effective factors on the efficiency of SPE procedure are optimized using faced-centered central composite design (FCCD). In addition, multi-response optimization by using Derringer's desirability function is used to find the optimum experimental conditions for extraction of analytes from well and river waters. Due to the complexity of water matrices and the presence of... 

    Fourier transform infrared spectroscopy: A potential technique for noninvasive detection of spermatogenesis

    , Article Avicenna Journal of Medical Biotechnology ; Vol. 6, Issue. 1 , 2014 , pp. 47-52 ; ISSN: 2008-4625 Gilany, K ; Moazeni Pouracil, R. S ; Reza Sadeghi, M ; Sharif University of Technology
    Abstract
    Background: The seminal plasma is an excellent source for noninvasive detection of spermatogenesis. The seminal plasma of normospermic and azoospermic men has been analyzed for detection of spermatogenesis. Methods: Optical spectroscopy (Attenuated Total Reflectance-Infrared spectroscopy (ATR-IR) and Fourier Transform infrared spectroscopy (FT-IR) has been used to analyze the seminal plasma and the metabolome of seminal plasma for detection of spermatogenesis. Results The seminal plasma of normospermic and azoospermic men has been analyzed by ATR-IR. The results show that there is a pattern variation in the azoospermic men compared to normospermic men. However, the seminal plasma is too... 

    Chromatographic fingerprint analysis of secondary metabolites in citrus fruits peels using gas chromatography-mass spectrometry combined with advanced chemometric methods

    , Article Journal of Chromatography A ; Volume 1251 , 2012 , Pages 176-187 ; 00219673 (ISSN) Parastar, H ; Jalali Heravi, M ; Sereshti, H ; Mani Varnosfaderani, A ; Sharif University of Technology
    2012
    Abstract
    Multivariate curve resolution (MCR) and multivariate clustering methods along with other chemometric methods are proposed to improve the analysis of gas chromatography-mass spectrometry (GC-MS) fingerprints of secondary metabolites in citrus fruits peels. In this way, chromatographic problems such as baseline/background contribution, low S/N peaks, asymmetric peaks, retention time shifts, and co-elution (overlapped and embedded peaks) occurred during GC-MS analysis of chromatographic fingerprints are solved using the proposed strategy. In this study, first, informative GC-MS fingerprints of citrus secondary metabolites are generated and then, whole data sets are segmented to some... 

    Binding assessment of two arachidonic-based synthetic derivatives of adrenalin with β-lactoglobulin: Molecular modeling and chemometrics approach

    , Article Biophysical Chemistry ; Volume 207 , 2015 , Pages 97-106 ; 03014622 (ISSN) Gholami, S ; Bordbar, A. K ; Akvan, N ; Parastar, H ; Fani, N ; Gretskaya, N. M ; Bezuglov, V. V ; Haertlé, T ; Sharif University of Technology
    Elsevier  2015
    Abstract
    A computational approach to predict the main binding modes of two adrenalin derivatives, arachidonoyl adrenalin (AA-AD) and arachidonoyl noradrenalin (AA-NOR) with the β-lactoglubuline (BLG) as a nano-milk protein carrier is presented and assessed by comparison to the UV-Vis absorption spectroscopic data using chemometric analysis. Analysis of the spectral data matrices by using the multivariate curve resolution-alternating least squares (MCR-ALS) algorithm led to the pure concentration calculation and spectral profiles resolution of the chemical constituents and the apparent equilibrium constants computation. The negative values of entropy and enthalpy changes for both compound indicated... 

    MVC app: A smartphone application for performing chemometric methods

    , Article Chemometrics and Intelligent Laboratory Systems ; Volume 147 , October , 2015 , Pages 105-110 ; 01697439 (ISSN) Parastar, H ; Shaye, H ; Sharif University of Technology
    Elsevier  2015
    Abstract
    In this work, a novel smartphone application entitled ". MVC app" is developed to perform different multivariate calibration methods. This app is designed for chemists who are not expert in programming or in advanced statistics. The developed application can use any Android-powered device as an environment for running. It is an easy to use app which can simply install in your smartphone and play. Different multivariate calibration methods, such as multiple linear regression (MLR), principal component regression (PCR) and partial least squares (PLS) are included in this app. As an instance, for performing PLS modeling, first calibration and validation data sets are imported (via USB or... 

    Chemometric-based determination of polycyclic aromatic hydrocarbons in aqueous samples using ultrasound-assisted emulsification microextraction combined to gas chromatography-mass spectrometry

    , Article Journal of Chromatography A ; Volume 1413 , September , 2015 , Pages 117-126 ; 00219673 (ISSN) Ahmadvand, M ; Sereshti, H ; Parastar, H ; Sharif University of Technology
    Elsevier  2015
    Abstract
    In the present research, ultrasonic-assisted emulsification-microextraction (USAEME) coupled with gas chromatography-mass spectrometry (GC-MS) has been proposed for analysis of thirteen environmental protection agency (EPA) polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Tetrachloroethylene was selected as extraction solvent. The main parameters of USAEME affecting the efficiency of the method were modeled and optimized using a central composite design (CCD). Under the optimum conditions (9 μL for extraction solvent, 1.15% (w/v) NaCl (salt concentration) and 10min for ultrasonication time), preconcentration factor (PF) of the PAHs was in the range of 500-950. In order to have a... 

    MCRC software: A tool for chemometric analysis of two-way chromatographic data

    , Article Chemometrics and Intelligent Laboratory Systems ; Volume 104, Issue 2 , 2010 , Pages 155-171 ; 01697439 (ISSN) Jalali Heravi, M ; Parastar, H ; Kamalzadeh, M ; Tauler, R ; Jaumot, J ; Sharif University of Technology
    2010
    Abstract
    This paper describes the development and implementation of MCRC software, chemometric software for Multivariate Curve Resolution of two-way Chromatographic data. MCRC software is developed for chemometric analysis of chromatographic data; however, it may also be used for other types of multivariate data. It consists of five groups of techniques for preprocessing, chemical rank determination, local rank analysis, multivariate resolution and peak integration. This software has the ability of the analysis of complex multi-component chromatographic signals of gas chromatography-mass spectrometry (GC-MS) and high performance liquid chromatography-diode array detection (HPLC-DAD). The software... 

    Optimization of dispersive liquid-liquid microextraction and improvement of detection limit of methyl tert-butyl ether in water with the aid of chemometrics

    , Article Journal of Chromatography A ; Volume 1217, Issue 45 , November , 2010 , Pages 7017-7023 ; 00219673 (ISSN) Karimi, M ; Sereshti, H ; Samadi, S ; Parastar, H ; Sharif University of Technology
    2010
    Abstract
    Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry-selective ion monitoring (GC-MS-SIM) was applied to the determination of methyl tert-butyl ether (MTBE) in water samples. The effect of main parameters affecting the extraction efficiency was studied simultaneously. From selected parameters, volume of extraction solvent, volume of dispersive solvent, and salt concentration were optimized by means of experimental design. The statistical parameters of the derived model were R 2=0.9987 and F=17.83. The optimal conditions were 42.0μL for extraction solvent, 0.30mL for disperser solvent and 5% (w/v) for sodium chloride. The calibration linear range... 

    Quality assessment of gasoline using comprehensive two-dimensional gas chromatography combined with unfolded partial least squares: A reliable approach for the detection of gasoline adulteration

    , Article Journal of Separation Science ; Volume 39, Issue 2 , 2016 , Pages 367-374 ; 16159306 (ISSN) Parastar, H ; Mostafapour, S ; Azimi, G ; Sharif University of Technology
    Wiley-VCH Verlag 
    Abstract
    Comprehensive two-dimensional gas chromatography and flame ionization detection combined with unfolded-partial least squares is proposed as a simple, fast and reliable method to assess the quality of gasoline and to detect its potential adulterants. The data for the calibration set are first baseline corrected using a two-dimensional asymmetric least squares algorithm. The number of significant partial least squares components to build the model is determined using the minimum value of root-mean square error of leave-one out cross validation, which was 4. In this regard, blends of gasoline with kerosene, white spirit and paint thinner as frequently used adulterants are used to make... 

    NMR spectroscopy-based metabolomic study of serum in sulfur mustard exposed patients with lung disease

    , Article Biomarkers ; Volume 22, Issue 5 , 2017 , Pages 413-419 ; 1354750X (ISSN) Nobakht, B.F., M. Gh ; Arefi Oskouie, A ; Rezaei Tavirani, M ; Aliannejad, R ; Taheri, S ; Fathi, F ; Naseri, M. T ; Sharif University of Technology
    Taylor and Francis Ltd  2017
    Abstract
    Sulfur mustard (SM) is a vesication chemical warfare agent for which there is currently no antidote. Despite years of research, there is no common consensus about the pathophysiological basis of chronic pulmonary disease caused by this chemical warfare agent. In this study, we combined chemometric techniques with nuclear magnetic resonance (NMR) spectroscopy to explore the metabolic profile of sera from SM-exposed patients. A total of 29 serum samples obtained from 17 SM-injured patients, and 12 healthy controls were analyzed by Random Forest. Increased concentrations of seven amino acids, glycerol, dimethylamine, ketone bodies, lactate, acetate, citrulline and creatine together with the... 

    Chemometrics comparison of gas chromatography with mass spectrometry and comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry Daphnia magna metabolic profiles exposed to salinity

    , Article Journal of Separation Science ; Volume 41, Issue 11 , 2018 , Pages 2368-2379 ; 16159306 (ISSN) Parastar, H ; Garreta Lara, E ; Campos, B ; Barata, C ; Lacorte, S ; Tauler, R ; Sharif University of Technology
    Wiley-VCH Verlag  2018
    Abstract
    The performances of gas chromatography with mass spectrometry and of comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry are examined through the comparison of Daphnia magna metabolic profiles. Gas chromatography with mass spectrometry and comprehensive two-dimensional gas chromatography with mass spectrometry were used to compare the concentration changes of metabolites under saline conditions. In this regard, a chemometric strategy based on wavelet compression and multivariate curve resolution–alternating least squares is used to compare the performances of gas chromatography with mass spectrometry and comprehensive two-dimensional gas chromatography with... 

    RMet: An automated R based software for analyzing GC-MS and GC×GC-MS untargeted metabolomic data

    , Article Chemometrics and Intelligent Laboratory Systems ; Volume 194 , 2019 ; 01697439 (ISSN) Moayedpour, S ; Parastar, H ; Sharif University of Technology
    Elsevier B.V  2019
    Abstract
    Gas chromatography-mass spectrometry (GC-MS) and comprehensive two-dimensional gas chromatography-mass spectrometry (GC×GC-MS) are powerful techniques for measurement of all metabolites in complex metabolic samples. However, analyzing GC-MS and especially GC×GC-MS metabolomic data is a major challenge to the researchers in the field of metabolomics mainly due to the complexity and large data size. In this regard, an automated R based software entitled RMet has been developed to overcome the challenges in the metabolomic analysis workflow of GC-MS and GC×GC-MS data sets. Additionally, it is able to facilitate the complex process of extracting reliable and useful biological information from... 

    Gas chromatographic fingerprint analysis of secondary metabolites of Stachys lanata (Stachys byzantine C. Koch) combined with antioxidant activity modelling using multivariate chemometric methods

    , Article Journal of Chromatography A ; Volume 1602 , 2019 , Pages 432-440 ; 00219673 (ISSN) Aminfar, P ; Abtahi, M ; Parastar, H ; Sharif University of Technology
    Elsevier B.V  2019
    Abstract
    S. lanata has been traditionally used as a medicinal plant due to its various biological activities such as antioxidant activity. Therefore, identification and quality control studies of this plant are of great importance. To this end, gas chromatography (GC) combined with chemometrics was proposed for fingerprint analysis of S. lanata samples. This study sought to classify GC fingerprints of twenty-eight S. lanata samples from eight different regions of Iran and more importantly, to correlate fingerprints to the antioxidant activity to select S. lanata volatile antioxidant markers. S. lanata samples were classified into five and three classes using partial least squares-discriminant... 

    Chemometric techniques coupled with NMR for matabolic profiling of lettuce exposed to polycyclic aromatic hydrocarbones

    , Article Analytical Biochemistry ; Volume 611 , 2020 Feizi, N ; Seraj, M ; Tajali, R ; Shavandi, S. R ; Parastar, H ; Sharif University of Technology
    Academic Press Inc  2020
    Abstract
    Treated waste water (TWW) quality varies due to the occurrence of polycyclic aromatic hydrocarbons (PAHs) up to low μg L−1. In this study, a non-targeted metabolomic analysis was performed on lettuce (Lactuca sativa L) exposed to 4 PAHs by irrigation. The plants were watered with different concentrations of contaminants (0–100 μg L−1) for 39 days under controlled conditions and then harvested, extracted and analyzed by nuclear magnetic resonance (NMR). Different chemometric tools based on principal component analysis (PCA) and partial least square discriminant analysis (PLS-DA) are proposed for the analysis of the complex data sets generated in the different exposure experiments.... 

    Development of a method for analysis of Iranian damask rose oil: combination of gas chromatography-mass spectrometry with Chemometric techniques

    , Article Analytica Chimica Acta ; Volume 623, Issue 1 , 8 August , 2008 , Pages 11-21 ; 00032670 (ISSN) Jalali Heravi, M ; Parastar, H ; Sereshti, H ; Sharif University of Technology
    2008
    Abstract
    Gas chromatography-mass spectrometry (GC-MS) combined with Chemometric resolution techniques were proposed as a method for the analysis of volatile components of Iranian damask rose oil. The essential oil of damask rose was extracted using hydrodistillation method and analyzed with GC-MS in optimized conditions. A total of 70 components were identified using similarity searches between mass spectra and MS database. This number was extended to 95 components with concentrations higher than 0.01% accounting for 94.75% of the total relative content using Chemometric techniques. For the first time in this work, an approach based upon subspace comparison is used for determination of the chemical... 

    Comparison between two different hemichromes of hemoglobins (HbA and HbS) induced by n-dodecyl trimethylammonium bromide: Chemometric study

    , Article Colloids and Surfaces B: Biointerfaces ; Volume 63, Issue 2 , 2008 , Pages 183-191 ; 09277765 (ISSN) Mojtahedi, M ; Parastar, H ; Jalali Heravi, M ; Chamani, J ; Chilaka, F. C ; Moosavi Movahedi, A. A ; Sharif University of Technology
    2008
    Abstract
    The interaction of n-dodecyl trimethylammonium bromide (DTAB) with oxyhemoglobin A and oxyhemoglobin S is investigated using UV-visible absorption spectra and chemometric resolution techniques. Oxyhemoglobins (A and S) induced to partial oxidized form (ferrihemoglobin) by DTAB and finally transform to fully oxidized hemichrome. Hemichrome mole fractions of HbS are more than HbA because of more hydrophobic interaction of DTAB-HbS in second set of binding site relative to DTAB-HbA. The visible spectra between 500 and 650 nm are used for identifying the present components in solution because each species of hemoglobin has a specific spectrum in this region. The number of components and mole... 

    Characterization of essential oil components of Iranian geranium oil using gas chromatography-mass spectrometry combined with chemometric resolution techniques

    , Article Journal of Chromatography A ; Volume 1114, Issue 1 , 2006 , Pages 154-163 ; 00219673 (ISSN) Jalali Heravi, M ; Zekavat, B ; Sereshti, H ; Sharif University of Technology
    2006
    Abstract
    The essential oil components of geranium oil cultivated in center of Iran were identified and determined using gas chromatography-mass spectrometry data combined with the chemometric resolution techniques. A total of 61 components accounting for 91.51% were identified using similarity searches between the mass spectra and MS database. This number was extended to 85 components using chemometric techniques. Various chemometric methods such as morphological scores, simplified Borgen method (SBM) and fixed size moving window evolving factor analysis (FSMWEFA) were used for determining the number of components, pure variables, zero concentration and selective regions. Then the overlapping peak... 

    Recent trends in application of chemometric methods for GC-MS and GC×GC-MS-based metabolomic studies

    , Article TrAC - Trends in Analytical Chemistry ; Volume 138 , 2021 ; 01659936 (ISSN) Feizi, N ; Hashemi Nasab, F. S ; Golpelichi, F ; Sabouruh, N ; Parastar, H ; Sharif University of Technology
    Elsevier B.V  2021
    Abstract
    Metabolomics is the science of studying small molecules (metabolites) in biological systems with the aim of getting insight into cells, biofluids and organisms. Chemometric methods are powerful tools to address data problems generated in metabolomic studies and to extract valuable information. This review focuses mainly on a range of chemometric methods used for processing of metabolomics data generated from gas chromatography-mass spectrometry (GC-MS) and comprehensive two-dimensional gas chromatography-mass spectrometry (GC × GC-MS). Herein, essential skills used for preprocessing of raw data, multivariate resolution, pattern recognition, variable selection and identification of... 

    Amoxicillin-loaded multilayer pullulan-based nanofibers maintain long-term antibacterial properties with tunable release profile for topical skin delivery applications

    , Article International Journal of Biological Macromolecules ; Volume 215 , 2022 , Pages 413-423 ; 01418130 (ISSN) Ajalloueian, F ; Asgari, S ; Guerra, P. R ; Chamorro, C. I ; Ilchenco, O ; Piqueras, S ; Fossum, M ; Boisen, A ; Sharif University of Technology
    Elsevier B.V  2022
    Abstract
    Unique physiochemical and biological properties of nanofibers along with the choice of a wide variety of materials for both fabrication and tunable release patterns make nanofibers an ideal option for drug delivery. Loading antibacterial agents into nanofibers has attracted great deal of attention. Whilst there are several studies focusing on applying new generations of antibacterial materials, antibiotics are still the gold standard in clinical applications. Therefore, we aimed at introducing antibiotic-loaded nanofiber substrates with potential for topical skin delivery applications, reduced consumption of antibiotics and increased storage time. We applied Amoxicillin (AMX) as a model drug...