    Parametric analyses on the initial stiffness of the SHS column base plate connections using FEM

    , Article Engineering Structures ; Volume 34 , 2012 , Pages 363-370 ; 01410296 (ISSN) Khodaie, S ; Mohamadi-shooreh, M. R ; Mofid, M ; Sharif University of Technology
    Abstract
    Bolted Column Base Plate (BCBP) connections are widely used to connect steel columns to the concrete foundations. This paper conducts a parametric study on the initial stiffness of bolted base plate with Square Hollow Section (SHS) column connection, through an extended 3-D Finite Element Modeling (FEM). Different features of the connection such as material behavior, geometric details, typical contact phenomena and large displacements are also considered in the modeling. A comparison between experimental test and FEM is carried out to illustrate the ability of the numerical method to simulate the connection behavior. An analytical explanation on the initial stiffness of the connection is... 

    Parametric Study of Simple Column-Base Connections under Cyclic Loading

    , M.Sc. Thesis Sharif University of Technology Ghaffari Cherati, Amir (Author) ; Mofid, Massoud (Supervisor)
    Abstract
    Column-base connections are one of the most important elements in steel structures which connect the steel frame to the foundation. Therefore, in structures erected in seismic areas, these connections are critical to convey cyclic inertia forces to the frame. In this research the author performed a parametric study utilizing Finite Elements Method (FEM) to investigate the connection’s cyclic behavior. Primarily, the modeling method is verified and calibrated by the use of available experimental data. Afterwards, the parametric computer models are made. Though some researchers have investigated similar connection types, some components’ parameters like the column’s dimensions have not been...