Loading...
Search for: continuity-of-services
0.004 seconds

    FPGA-based fast detection with reduced sensor count for a fault-tolerant three-phase converter

    , Article IEEE Transactions on Industrial Informatics ; Volume 9, Issue 3 , 2013 , Pages 1343-1350 ; 15513203 (ISSN) Mahmoud, M ; Philippe, P ; Shahrokh, S ; Mohammad Reza, M. R ; Sharif University of Technology
    2013
    Abstract
    Fast fault detection (FD) and reconfiguration is necessary for fault tolerant power electronic converters in safety critical applications to prevent further damage and to make the continuity of service possible. The aim of this study is to minimize the number of the used additional voltage sensors in a fault tolerant three-phase converter. In this paper, first a practical implementation of a very fast FD scheme with reduced sensor number is discussed. Then, an optimization in this scheme is also presented to decrease the detection time. For FD, special time and voltage criterion are applied to observe the error in the estimated phase-to-phase voltages for a specific period of time. The... 

    Wind energy conversion system based on DFIG with open switch fault tolerant six-legs AC-DC-AC converter

    , Article Proceedings of the IEEE International Conference on Industrial Technology, Cape Town ; February , 2013 , Pages 1656-1661 ; 9781467345699 (ISBN) Shahbazi, M ; Zolghadri, M. R ; Poure, P ; Saadate, S ; The Institute of Electrical and Electronics Engineers (IEEE); IEEE Industrial Electronics Society (IES); IEEE Technology Management Council; IEEE Region 8; IEEE South Africa Section IE/IA/PEL Joint Chapter ; Sharif University of Technology
    2013
    Abstract
    Continuity of service of wind energy conversion systems as well as their reliability and performances are some of the major concerns in this power generation area. Six-legs AC/DC/AC converters are normally used in modern wind energy systems like as in the system with a doubly-fed induction generator (DFIG). A sudden failure of the converter can lead to the total or partial loss of the control of the phase currents and can cause serious system malfunction or shutdown. Therefore, to prevent the spread of the fault to the other system components and to ensure continuity of service, fault tolerant converter topologies associated to quick and effective fault detection and compensation methods... 

    Fault-tolerant five-leg converter topology with FPGA-Based reconfigurable control

    , Article IEEE Transactions on Industrial Electronics ; Volume 60, Issue 6 , 2013 , Pages 2284-2294 ; 02780046 (ISSN) Shahbazi, M ; Poure, P ; Saadate, S ; Zolghadri, M. R ; Sharif University of Technology
    2013
    Abstract
    Fast fault detection and reconfiguration of power converters is necessary in electrical drives to prevent further damage and to make the continuity of service possible. On the other hand, component minimized converters may provide the benefits of higher reliability and less volume and cost. In this paper, a new fault-tolerant converter topology is studied. This converter has five legs before the fault occurrence, and after fault detection the converter continues to function with four legs. A very fast fault detection and reconfiguration scheme is presented and studied. Simulations and experimental tests are performed to evaluate the structure requirements, the digital reconfigurable... 

    FPGA-based fault tolerant scheme with reduced extra-sensor number for WECS with DFIG

    , Article Proceedings - ISIE 2011: 2011 IEEE International Symposium on Industrial Electronics, 27 June 2011 through 30 June 2011 ; 2011 , Pages 1595-1601 ; 9781424493128 (ISBN) Shahbazi, M ; Gaillard, A ; Poure, P ; Zolghadri, M. R ; Sharif University of Technology
    2011
    Abstract
    Fast fault detection and converter reconfiguration is necessary for fault tolerant doubly fed induction generator (DFIG) in wind energy conversion systems (WECS) to prevent further damage and to make possible the continuity of service. Extra sensors are needed in order to detect the faults rapidly. In this paper, a very fast FPGA-based fault detection scheme is presented that minimizes the number of additional voltage sensors. A fault tolerant converter topology for this application is studied. Control and fault detection system are implemented on a single FPGA and Hardware in the Loop experiments are performed to evaluate the proposed detection scheme, the digital controller and the fault... 

    Fast detection of open-switch faults with reduced sensor count for a fault-tolerant three-phase converter

    , Article 2011 2nd Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2011 ; 2011 , Pages 546-550 ; 9781612844213 (ISBN) Shahbazi, M ; Zolghadri, M ; Poure, P ; Saadate, S ; Sharif University of Technology
    Abstract
    Fast fault detection and reconfiguration is necessary in power electronic converters in lots of applications to prevent further damage and to make possible the continuity of service. In this paper a very fast fault detection scheme is presented that minimizes the use of voltage sensors. A fault tolerant topology is studied. Control and fault detection system are implemented on a single FPGA and hardware in the loop experiments are performed to evaluate the detection scheme, the digital controller and the structure  

    Six-leg AC-AC fault tolerant converter with reduced extra-sensor number

    , Article International Review of Electrical Engineering ; Volume 6, Issue 1 , 2011 , Pages 132-138 ; 18276660 (ISSN) Shahbazi, M ; Poure, P ; Zolghadri, M. R ; Saadate, S ; Sharif University of Technology
    Abstract
    In order to prevent further damage and to provide the continuity of service of six-leg converter in case of open-switch fault, it is mandatory to perform fast fault detection and converter reconfiguration schemes. Extra sensors are needed to detect the faults rapidly. In this paper, a very fast FPGA-based fault detection scheme is presented that minimizes the number of additional voltage sensors. A six-leg fault tolerant converter topology without redundancy and with bidirectional power flow is studied. First simulations are carried out to evaluate the proposed fault detection principle and the fault tolerant converter topology. The fully digital control and the fault detection are...