    A robust short-circuit fault diagnosis for high voltage DC power supply based on multisensor data fusion

    , Article 10th International Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2019, 12 February 2019 through 14 February 2019 ; 2019 , Pages 659-664 ; 9781538692547 (ISBN) Ayoubi, R ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Short-circuit fault (SCF) detection is mandatory in a high voltage DC power supply (HVPS) to prevent fatal damage. The majority of converters employ a single sensor to detect the SCF. This attribute increases the interference vulnerability of the fault detection (FD) system in the presence of noise. Therefore, miss detections and false alarms are possible to occur. Miss detections and false alarms are harmful catastrophes in most applications. A commonly used method to suppress the noise impacts is using a low-bandwidth low-pass filter. However, the use of the low-bandwidth low-pass filter reduces the speed of FD due to the filter delay. This paper proposes a fast FD algorithm based on... 

    Performance comparison of the neyman-pearson fusion rule with counting rules for spectrum sensing in cognitive radio

    , Article Iranian Journal of Science and Technology - Transactions of Electrical Engineering ; Volume 36, Issue E1 , 2012 , Pages 1-17 ; 22286179 (ISSN) Mosleh, S ; Tadaion, A. A ; Derakhtian, M ; Aref, M. R ; Sharif University of Technology
    2012
    Abstract
    Distributed spectrum sensing (DSS) is of great importance in Cognitive Radio, especially under fading or shadowing effects. In order to evaluate the performance of a distributed system, it is commonly compared with the centralized system as an upper performance bound. Now the question is whether or not one can obtain a distributed strategy serving as an upper bound to benchmark any distributed strategy, tighter than that of the centralized scheme. Here, we suggest employing the Neyman-Pearson (NP) fusion rule to achieve an upper bound. Furthermore, the analysis of a randomized fusion rule has been provided, which is a long-existing problem in this field. For this purpose, theoretical... 

    Applying of Data Fusion Method for Improving the Protection System of the High Voltage DC Power Supply

    , M.Sc. Thesis Sharif University of Technology Ayoubi, Ramin (Author) ; Kaboli, Shahriyar (Supervisor)
    Abstract
    Short-circuit fault detection is mandatory in a high voltage DC power supply to prevent fatal damage. The majority of converters employ a single sensor to detect the short-circuit fault. This attribute increases the interference vulnerability of the fault detection system in the presence of noise. Therefore, miss detections and false alarms are possible to occur. Miss detections and false alarms are harmful catastrophes in most applications. A commonly used method to suppress the noise impacts is using a low-bandwidth low-pass filter. However, the use of the low-bandwidth low-pass filter reduces the speed of fault detection due to the filter delay. This paper proposes a fast fault detection...