Loading...
Search for: dilatancy
0.004 seconds
Total 39 records

    Expansion Modeling of Coronary Stent for Selection of Optimized Stent

    , M.Sc. Thesis Sharif University of Technology Izadi Ramini, Elaheh (Author) ; Movahhedy, Mohammad Reza (Supervisor)
    Abstract
    Referring to mortality increasment having sprung from atherosclerosis, work on treatment of coronary heart disease seems to be necessary. Stent implementation is one of stenosis treatment. Stent deployment has been done during past two decades, but clinical evidence showed that because of some weakness in designing and implementing, restenosis occurs again. Material, structure and coating texture of stent are the designing criteria beside stent implementation importance. Thus a lot of activities have been done in this area to improve performance of these applications. Nowadays a lot of companies' researchers try the best to get better their products; consequently there is different types of... 

    Meaurement of Flow Mediated Dilation Using Photoplethysmography

    , M.Sc. Thesis Sharif University of Technology Goldoozian, Layli Sadat (Author) ; Zahedi, Edmond (Supervisor)
    Abstract
    Endothelial cells cover the inner surface of blood vessels. In response to different physical (such as reactive hyperemia-RH) and pharmacological stimuli, they maintain homeostasis by changing the vascular diameter (by releasing chemical agents like nitric oxide). The endothelium inability to respond to metabolic need (endothelial dysfunction) is an early marker of cardiovascular diseases such as atherosclerosis. Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmographic (PPG) signal changes... 

    Development of a Wrist PPG Probe for the Measurement of Radial Artery Diameter

    , M.Sc. Thesis Sharif University of Technology Keikhosravi, Adib (Author) ; Zahedi, Edmond (Supervisor)
    Abstract
    Inability of endothelial cells in responding to metabolic needs (endothelial dysfunction,) is a sign of heart diseases like atherosclerosis and vascular stenosis. Recently, a new method using finger PPG signal has been proposed to determine endothelial function in response to reactive hypertension (RH.) PPG-based endothelial function assessment results are not fully correlated with ultrasound FMD tests, and this is because of some auto-regulation phenomena in the fingertip. It is expected that such problems will not exist in larger arteries, like the radial artery. The goal of this project is to acquire the PPG signal from the radial artery as it is proportional to blood volume changes in... 

    Investigation of Stress-Dependence on Hydro-Mechanical Properties of Fractured Rocks

    , M.Sc. Thesis Sharif University of Technology Khazaie, Sina (Author) ; Goodarznia, Iraj (Supervisor)
    Abstract
    Fracture and Matrix permeability systematically change because production time of gas and oil reservoirs is very long and pore pressure, temperature and in-situ stresses continously change in reservoirs.This parameters have an important role in determination and development of wells according to the permeability distribution.The main factors in determination of fracture permeability values is normal and shear stiffness that parameters such as roughness, opening, closure, aperture and asperities influence this factor.In this thesis, we try to investigate the influence of this parameters on fracture permeability according to the normal and shear stresses.Also we want to investigate the... 

    Analyzing the Endothelial Function by Means of Photoplethysmogram Signal Modeling

    , M.Sc. Thesis Sharif University of Technology Amiri, Mina (Author) ; Zahedi, Edmond (Supervisor) ; Behnia, Fereidoon (Supervisor)
    Abstract
    The endothelial (the artery inner lumen cells) function is associated with cardiovascular risk factors. Its assessment methods can be classified into the two groups of invasive and noninvasive ones. The most widely used method among the current non-invasive tests employed in research settings is flow-mediated dilation (FMD). This technique measures endothelial function by inducing reactive hyperemia via the temporary arterial occlusion and measuring the resultant relative increase in the blood vessel diameter via ultrasound. The high price and large size of the device, and being operator dependent are the limitation of this method. In this work, we propose using the photoplethysmogram (PPG)... 

    Modeling the Endothelial Function in the Brachial Artery Using Photoplethysmography

    , M.Sc. Thesis Sharif University of Technology Mashayekhi, Ghoncheh (Author) ; Zahedi, Edmond (Supervisor) ; Jahed, Mehran (Supervisor)
    Abstract
    Flow Mediated Dilation (FMD) is a non-invasive method for endothelial function assessment providing an index extracted from ultrasonic B-mode images. Although utilized in the research community, the difficulty of its application and high cost of ultrasonic device prevent it from being widely used in clinical settings. In this study we show that substituting the ultrasonic device with more easily handled and low cost photoplethysmography and electrocardiography is possible. We introduce new indices based on the photoplethysmogram (PPG) and electrocardiogram (ECG) and show that they are correlated with the ultrasound-based FMD index. To this end, conventional ultrasound FMD test was carried... 

    Prediction of Coronary Angiography Results by Flow Mediated Dilation Assessments with Photoplethysmography

    , M.Sc. Thesis Sharif University of Technology Hosseini, Zahra Sadat (Author) ; Zahedi, Edmond (Supervisor) ; Fakhrzadeh, Hossein (Supervisor)
    Abstract
    Cardio Vascular Diseases (CVD) is currently the most important cause of mortality in the world. Coronary artery disease (CAD-with 3 major epicardial vessels) is one of the significant CVD. Coronary angiography remains the gold standard for identifying the presence and absence of stenosis due to CAD. It is performed by inserting a catheter into the coronary artery, directly injecting radiopaque contrast material there and recording radiographic images in different view of arteries. Images of this invasive way show severity and area of stenosis.
    A sign of CAD is endothelial dysfunction (inner artery layer) in peripheral arteries like the brachial artery. Due to a significant correlation... 

    Modeling the Relationship between Central Aortic Pressure and Radial Photoplethysmogram in Flow-mediated Dilation Test

    , Ph.D. Dissertation Sharif University of Technology Parsafar, Mohammad Habib (Author) ; Vosughi Vahdat, Bijan (Supervisor) ; Zahedi, Edmond (Supervisor)
    Abstract
    According to the World Health Organization, about 35% of deaths worldwide are due to cardiovascular diseases, therefore the evaluation of vascular endothelial function has great prognostic and diagnostic value for cardiovascular diseases. The conventional noninvasive method for endothelial function evaluation is the measurement of flow-mediated dilation in brachial artery using ultrasound imaging (FMD-US). As the accuracy of FMD-US depends on the operator's skill and the resolution of the ultrasound images, this method has not been adopted. In this work, we propose to use a low cost, easily-accessible surrogate signal, the photoplethysmogram (PPG) to implement the FMD test. Whereas previous... 

    A Micro-structural Study on Hydro-mechanical Behavior of Loess

    , Ph.D. Dissertation Sharif University of Technology Sadeghi, Hamed (Author) ; Jafarzadeh, Fardin (Supervisor) ; W. W. NG, Charles (Supervisor)
    Abstract
    Loess soil layers in semi-arid to arid areas have been deposited through the accumulation of aeolian sediments, resulted in a special metastable and open structure being usually unsaturated in nature. Since naturally occurred loess is widespread, it has been recently considered as a promising resource for constructing earth-fill structures. However, due to different microstructures of intact and recompacted loess, different responses to hydraulic and mechanical loading would be expected. Up to now, the hydro-mechanical behavior of loess from different perspectives has not been linked to its microstructural characteristics. The current research, therefore, aims to provide insight into the... 

    Rheology of interfacial layers

    , Article Current Opinion in Colloid and Interface Science ; Vol. 19, issue. 6 , 2014 , pp. 514-519 ; ISSN: 13590294 Karbaschi, M ; Lotfi, M ; Kragel, J ; Javadi, A ; Bastani, D ; Miller, R ; Sharif University of Technology
    Abstract
    Dilational and shear viscoelasticities are important properties of interfacial layers. These quantities are particularly relevant in all systems which contain a huge internal interfacial area such as foams and emulsions. Therefore, also the 3D rheological behavior of foams or emulsions studied by respective methods is superimposed by the 2D interfacial rheology.We report on recent developments in dilational and shear rheology from an experimental point of view as well as discuss the state of the art of the underlying theories. Examples of most relevant experiments are also presented and discussed. Although not yet extensively investigated, the links between bulk rheology of foams and... 

    A robust zero-watermarking scheme using Canny edge detector

    , Article International Journal of Electronic Security and Digital Forensics ; Volume 5, Issue 1 , 2013 , Pages 25-44 ; 1751911X (ISSN) Shakeri, M ; Jamzad, M ; Sharif University of Technology
    2013
    Abstract
    By expansion of digital multimedia and networking technology, the problem of ownership protection has become increasingly important. Digital watermarking is an efficient way for copyright protection of digital images. Traditional watermarking techniques degrade the quality of host image by embedding a watermark logo. Facing this problem, a new watermarking approach called zero-watermarking has been proposed. In zero-watermarking methods, the watermark does not require to be embedded into the protected image but it uses both the watermark and the protected image to generate a verification map which is registered to a trusted authority for further protection. In this paper we propose a robust... 

    Discrimination of bilateral finger photoplethysmogram responses to reactive hyperemia in diabetic and healthy subjects using a differential vascular model framework

    , Article Physiological Measurement ; Volume 34, Issue 5 , 2013 , Pages 513-525 ; 09673334 (ISSN) Keikhosravi, A ; Aghajani, H ; Zahedi, E ; Sharif University of Technology
    2013
    Abstract
    Endothelial dysfunction assessment has received considerable attention due to its potential in early screening of cardiovascular diseases. Since the seminal work by Celermajer in flow-mediated dilation (FMD) based on B-mode ultrasound measurement of the brachial artery dilation following limb ischemia, many attempts have been made toward applying this method to clinical, non-invasive endothelial dysfunction assessment. One major obstacle toward achieving this objective has been the relative high cost of the required setup and skilled manpower. Such limitations have prompted the investigation of other non-invasively accessible signals such as the photoplethysmogram (PPG) in relation to FMD.... 

    Fast dynamic interfacial tension measurements and dilational rheology of interfacial layers by using the capillary pressure technique

    , Article Colloids and Surfaces A: Physicochemical and Engineering Aspects ; Volume 407 , August , 2012 , Pages 159-168 ; 09277757 (ISSN) Javadi, A ; Krägel, J ; Makievski, A. V ; Kovalchuk, V. I ; Kovalchuk, N. M ; Mucic, N ; Loglio, G ; Pandolfini, P ; Karbaschi, M ; Miller, R ; Sharif University of Technology
    Elsevier  2012
    Abstract
    The oscillating drop and bubble analyzer (ODBA) is an experimental set-up based on the measurement of capillary pressure under static and dynamic conditions. It allows studies of slow and fast dynamic surface and interfacial tensions, following different growing and oscillating drop or bubble protocols, as well as determination of the dilational interfacial visco-elasticity of liquid interfacial layers. For the visco-elasticity studies, drops or bubbles are subjected to harmonic oscillations of area or volume in a broad frequency range, and the resulting harmonic capillary pressure response is analyzed by Fourier analysis. Also, transient relaxations can be easily performed, which are of... 

    Electrical analog model of arterial compliance during reactive hyperemia

    , Article 2011 1st Middle East Conference on Biomedical Engineering, MECBME 2011, 21 February 2011 through 24 February 2011, Sharjah ; 2011 , Pages 49-53 ; 9781424470006 (ISBN) Goldoozian, L. S ; Zahedi, E ; Sharif University of Technology
    2011
    Abstract
    Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmogram (PPG) changes during reactive hyperemia. It was shown that the amplitude of the PPG pulse (FMD-PPG) changed in a quite similar manner to that of the artery diameter in the method of the FMD-US i.e. increases following releasing the cuff and then gradually returns to baseline. In this study PPG changes following reactive hyperaemia were modelled using time-varying passive electrical elements (R, L and C). The output of the electric analog... 

    Flow mediated dilation with photoplethysmography as a substitute for ultrasonic imaging

    , Article Physiological Measurement ; Volume 36, Issue 7 , 2015 , Pages 1551-1571 ; 09673334 (ISSN) Mashayekhi, G ; Zahedi, E ; Movahedian Attar, H ; Sharifi, F ; Sharif University of Technology
    Institute of Physics Publishing  2015
    Abstract
    Flow mediated dilation (FMD) is a non-invasive method for endothelial function assessment providing an index extracted from ultrasonic B-mode images. Although utilized in the research community, the difficulty of its application and high cost of ultrasonic devices prevent it from being widely used in clinical settings. In this study we show that substituting the ultrasonic device with more easily handled and low cost photoplethysmography and electrocardiography is possible. We introduce new indices based on the photoplethysmogram (PPG) and electrocardiogram (ECG) and show that they are correlated with the ultrasound-based FMD Index. To this end, a conventional ultrasound FMD test was carried... 

    Comparing three image processing algorithms to estimate the grain-size distribution of porous rocks from binary 2D images and sensitivity analysis of the grain overlapping degree

    , Article Special Topics and Reviews in Porous Media ; Volume 6, Issue 1 , 2015 , Pages 71-89 ; 21514798 (ISSN) Rabbani, A ; Ayatollahi, S ; Sharif University of Technology
    Begell House Inc  2015
    Abstract
    The grain-size distribution (GSD) of porous rocks is important in order to better understand their hydrodynamic behavior. Clear and precise GSD data can be used to computationally reconstruct rock structure for further analysis. In this study, three main algorithms for image analysis have been examined to estimate the GSD of clastic rocks. The main challenge in GSD determination from images is in detecting overlapping grains and measuring their size separately. In this study, three previously developed image processing algorithms are implemented on two-dimensional (2D) binary images of rocks in order to compare the obtained GSD from each of the methods, i.e., the mean intercept length... 

    Discrimination between different degrees of coronary artery disease using time-domain features of the finger photoplethysmogram in response to reactive hyperemia

    , Article Biomedical Signal Processing and Control ; Volume 18 , 2015 , Pages 282-292 ; 17468094 (ISSN) Hosseini, Z. S ; Zahedi, E ; Movahedian Attar, H ; Fakhrzadeh, H ; Parsafar, M. H ; Sharif University of Technology
    Elsevier Ltd  2015
    Abstract
    Atherosclerosis is a major cause of coronary artery disease leading to morbidity and mortality worldwide. Currently, coronary angiography is considered to be the most accurate technique to diagnose coronary artery disease (CAD). However, this technique is an invasive and expensive procedure with risks of serious complications. Since the symptoms of CAD are not noticed until advanced stages of the disease, early and effective diagnosis of CAD is considered a pertinent measure. In this paper, a non-invasive optical signal, the finger photoplethysmogram (PPG) obtained before and after reactive hyperemia is investigated to discriminate between subjects with different CAD conditions. To this end,... 

    A nonlinear theoretical model for prediction of mechanical behavior of particulate composites and experimental verification of the model predictions

    , Article Polymer Composites ; Volume 31, Issue 7 , August , 2010 , Pages 1150-1155 ; 02728397 (ISSN) Ramazani, A. S. A ; Najafi, N. C ; Sharif University of Technology
    2010
    Abstract
    A model for prediction the stress-strain behavior of particulate composite over wide ranges of filler concentration and composite deformation has been developed through combination of Anderson's and Yilmizer's model. The constitutive equations are extracted from first law of thermodynamic and nonlinear dilatational effects which are produced by filler-matrix debonding process. In addition to nonlinear behavior that has been resulted by filler-matrix debonding and was presented by Yilmizer, the formation and growing of void or cavitations has been also introduced in this model, whereas Anderson's model, most important reason for deviation of linear behavior is filler-matrix debonding and has... 

    Effect of dyslipidemia on a simple morphological feature extracted from photoplethysmography flow mediated dilation

    , Article International Conference in Electronic Engineering and Computing Technology, London, 1 July 2009 through 3 July 2009 ; Volume 60 LNEE , 2010 , Pages 551-561 ; 18761100 (ISSN) ; 9789048187751 (ISBN) Zaheditochai, M ; Zahedi, E ; Mohd Ali, M. A ; Sharif University of Technology
    2010
    Abstract
    Dyslipidemia is considered to be one of the main heart risk factors, affecting the endothelial vascular function, which can be non-invasively investigated by ultrasound flow-mediated dilation (US-FMD). However, US-FMD comes at a high-cost and is operator-dependent. In this paper, the effect of dyslipidemia on the photoplethysmogram (PPG) signal recorded from collateral index fingers is investigated following a previous study where it was shown that results similar to that of US-FMD can be replicated by the PPG. Two groups, consisting of 30 healthy subjects free from any risk factors and 30 subjects who have only dyslipidemia as risk factor were respectively considered. The percent change in... 

    Mathematical modeling of CSF pulsatile hydrodynamics based on fluid-solid interaction

    , Article IEEE Transactions on Biomedical Engineering ; Volume 57, Issue 6 , 2010 , Pages 1255-1263 ; 00189294 (ISSN) Masoumi, N ; Bastani, D ; Najarian, S ; Ganji, F ; Farmanzad, F ; Seddighi, A. S ; Sharif University of Technology
    2010
    Abstract
    Intracranial pressure (ICP) is derived from cerebral blood pressure and cerebrospinal fluid (CSF) circulatory dynamics and can be affected in the course of many diseases. Computer analysis of the ICP time pattern plays a crucial role in the diagnosis and treatment of those diseases. This study proposes the application of Linninger et al.s [IEEE Trans. Biomed. Eng. , vol. 52, no. 4, pp. 557565, Apr. 2005] fluidsolid interaction model of CSF hydrodynamic in ventricular system based on our clinical data from a group of patients with brain parenchyma tumor. The clinical experiments include the arterial blood pressure (ABP), venous blood pressure, and ICP in the subarachnoid space (SAS). These...