UPFC for enhancing power system reliability
, Article IEEE Transactions on Power Delivery ; Vol. 25, issue. 4 , 2010 , p. 2881-2890 ; ISSN: 8858977 ; Fotuhi-Firuzabad, M ; Shahidehpour, M ; Feuillet, R ; Sharif University of Technology
Abstract
This paper discusses various aspects of unified power flow controller (UPFC) control modes and settings and evaluates their impacts on the power system reliability. UPFC is the most versatile flexible ac transmission system device ever applied to improve the power system operation and delivery. It can control various power system parameters, such as bus voltages and line flows. The impact of UPFC control modes and settings on the power system reliability has not been addressed sufficiently yet. A power injection model is used to represent UPFC and a comprehensive method is proposed to select the optimal UPFC control mode and settings. The proposed method applies the results of a contingency...
UPFC for enhancing power system reliability
, Article IEEE Transactions on Power Delivery ; Volume 25, Issue 4 , 2010 , Pages 2881-2890 ; 08858977 (ISSN) ; Fotuhi Firuzabad, M ; Shahidehpour, M ; Feuillet, R ; Sharif University of Technology
2010
Abstract
This paper discusses various aspects of unified power flow controller (UPFC) control modes and settings and evaluates their impacts on the power system reliability. UPFC is the most versatile flexible ac transmission system device ever applied to improve the power system operation and delivery. It can control various power system parameters, such as bus voltages and line flows. The impact of UPFC control modes and settings on the power system reliability has not been addressed sufficiently yet. A power injection model is used to represent UPFC and a comprehensive method is proposed to select the optimal UPFC control mode and settings. The proposed method applies the results of a contingency...
Two-level optimal load-frequency control for multi-area power systems
, Article International Journal of Electrical Power and Energy Systems ; Volume 53, Issue 1 , December , 2013 , Pages 540-547 ; 01420615 (ISSN) ; Sadati, N ; Sharif University of Technology
2013
Abstract
In large-scale power systems, classical centralized control approaches may fail due to geographically distribution of information and decentralized controllers result in sub-optimal solution for load-frequency control (LFC) problems. In this paper, a two-level structure is presented to obtain optimal solution for LFC problems and also reduce the computational complexity of centralized controllers. In this approach, an interconnected multi-area power system is decomposed into several sub-systems (areas) at the first-level. Then an optimization problem in each area is solved separately, with respect to its local information and interaction signals coming from other areas. At the second-level,...
The impact of demand response programs on UPFC placement
, Article Turkish Journal of Electrical Engineering and Computer Sciences ; Volume 27, Issue 6 , 2019 , Pages 4624-4639 ; 13000632 (ISSN) ; Ehsan, M ; Fotuhi Firuzabad, M ; Sharif University of Technology
Turkiye Klinikleri
2019
Abstract
Demand response (DR) and flexible AC transmission system (FACTS) devices can be effectively used for congestion management in power transmission systems. However, demand response program (DRP) implementation can itself affect the optimum location of FACTS devices, which is one of the main issues in power system planning. This paper investigates the impact of DRPs on unified power flow controller (UPFC) placement. The harmony search algorithm is employed to determine the optimum locations and parameter setting of UPFC in a long-term framework. The optimization problem is solved with different objectives including generation and congestion cost reduction, as well as loss reduction. In this...
Supervisory predictive control of power system load frequency control
, Article International Journal of Electrical Power and Energy Systems ; Vol. 61, issue , October , 2014 , p. 70-80 ; Ranjbar, A. M ; Sharif University of Technology
Abstract
Objective: The objective of this paper is to develop a hierarchical two-level power system load frequency control. Design: At the button level, standard PI controllers are utilized to control area's frequency and tie-line power interchanges. At the higher layer, model predictive control (MPC) is employed as a supervisory controller to determine the optimal set-point for the PI controllers in the lower layer. The proposed supervisory predictive controller computes the optimal set-points such that to coordinate decentralized local controllers. Blocking and coincidence point technology is employed to alleviate the computational effort of the MPC. In order to achieve the best closed loop...
Robust stability check for fractional PID-based control systems
, Article Transactions of the Institute of Measurement and Control ; Volume 35, Issue 2 , 2013 , Pages 236-246 ; 01423312 (ISSN) ; Haeri, M ; Sharif University of Technology
2013
Abstract
This paper considers a closed-loop system consisting of a fractional/integer order system and a fractional PID controller. Assuming that the uncertain coefficients of the fractional PID controller lie in some known intervals independently (i.e. that controller is a member of an interval family), the paper presents some easy to use theorems to investigate the robust bounded-input bounded-output stability of the resultant closed-loop system. Moreover, a finite frequency bound required in drawing the related graphs has also been provided. Finally, some numerical examples are presented to illustrate the results
Robust non-fragile fractional order PID controller for linear time invariant fractional delay systems
, Article Journal of Process Control ; Vol. 24, issue. 9 , 2014 , pp. 1489-1494 ; Haeri, M ; Sharif University of Technology
Abstract
A fractional order PID controller is designed to stabilize fractional delay systems with commensurate orders and multiple commensurate delays, where the time delays in the system may belong to several distinct intervals. Moreover, the controller parameters should belong to given intervals. In order to stabilize the system, the D-subdivision method is employed to choose the stabilizing set of the controller parameters from their available values. Furthermore, the nearest values of the obtained stabilizing set to their mean values are selected as the controller parameters so that a non-fragile controller is concluded. Two numerical examples evaluate the proposed control design method
Robust multivariable predictive based load frequency control considering generation rate constraint
, Article International Journal of Electrical Power and Energy Systems ; Volume 46, Issue 1 , March , 2013 , Pages 405-413 ; 01420615 (ISSN) ; Toulabi, M. R ; Ranjbar, A. M ; Sharif University of Technology
2013
Abstract
In this paper, a robust multivariable Model based Predictive Control (MPC) is proposed for the solution of load frequency control (LFC) in a multi-area power system. The proposed control scheme is designed to consider multivariable nature of LFC, system uncertainty and generation rate constraint, simultaneously. A constrained MPC is employed to calculate optimal control input including generation rate constraints. Economic allocation of generation is further ensured by modification of the predictive control objective function. To achieve robustness against system uncertainty and variation of parameters, a linear matrix inequality (LMI) based approach is employed. To validate the...
Robust control of the variable speed wind turbines in the presence of uncertainties: A comparison between H∞ and PID controllers
, Article Energy ; Volume 90 , October , 2015 , Pages 1508-1521 ; 03605442 (ISSN) ; Vossoughi, G ; Sharif University of Technology
Elsevier Ltd
2015
Abstract
To achieve a cost-effective and reliable use of wind power generation, advanced control techniques are required. In this paper, the application of two control strategies for the improvement of wind turbine power output is investigated in the presence of model/environmental uncertainties. Rotational speed of the wind turbine and consequently its power output are controlled via manipulation of blades pitch angle (at a constant generator torque). First, the classical PID controller is designed based on root locus analysis while in the second scheme, an H∞-robust controller is designed via μ-synthesis based on DKiteration algorithm. Performance of the two controllers in tracking of the desired...
Robust analysis and design of power system load frequency control using the Kharitonov's theorem
, Article International Journal of Electrical Power and Energy Systems ; Vol. 55, issue , 2014 , p. 51-58 ; Shiroei, M ; Ranjbar, A. M ; Sharif University of Technology
Abstract
This paper presents a robust decentralized proportional-integral (PI) control design as a solution of the load frequency control (LFC) in a multi-area power system. In the proposed methodology, the system robustness margin and transient performance are optimized simultaneously to achieve the optimum PI controller parameters. The Kharitonov's theorem is used to determine the robustness margin, i.e., the maximal uncertainty bounds under which the stable performance of the power system is guaranteed. The integral time square error (ITSE) is applied to quantify the transient performance of the LFC system. In order to tune the PI gains, the control objective function is optimized using the...
Power flow control and solutions with dynamic flow controller
, Article 2008 IEEE Electrical Power and Energy Conference - Energy Innovation, Vancouver, BC, 6 October 2008 through 7 October 2008 ; 2008 ; 9781424428953 (ISBN) ; Sheykholeslami, A ; Nabavi Niaki, A ; Ghaffari, H ; Sharif University of Technology
2008
Abstract
this paper presents two new methods for power flow calculation of power systems in presence of Dynamic Flow Controller (DFC), which is a new member of FACTS controllers. In first method A new steady state model of DFC is introduced for the implementation of the device in the conventional Newton-Raphson power flow algorithm. The impact of DFC on power flow is accommodated by adding new entries and modifying some existing ones in the linearized Jacobian equations of the same system without DFC. The focus of second method is on the discrete nature of the DFC and including its effects on power flow. This method is based on Nabavi model for FACTS devices. A case study on a power system located in...
Optimal unified power flow controller application to enhance total transfer capability
, Article IET Generation, Transmission and Distribution ; Volume 9, Issue 4 , 2015 , Pages 358-368 ; 17518687 (ISSN) ; Fotuhi Firuzabad, M ; Othman, M ; Sharif University of Technology
Institution of Engineering and Technology
2015
Abstract
For a power transfer path, total transfer capability (TTC) represents maximum power that can be transferred over the transmission system. Unified power flow controller (UPFC) is a device that can be used to increase in TTC. This study presents a new method for optimal UPFC application to minimise power loss while enhancing TTC. Based on UPFC injection model, the solution region of UPFC parameters is first found using the proposed method to maximise TTC. It then searches the solution region to find optimal UPFC control mode and setting to minimise system power loss. The proposed method is applied to the IEEE-Reliability Test System and the UPFC application impact are evaluated. Comparative...
Optimal placement of unified power flow controllers (UPFCs) using mixed-integer non-linear programming (MINLP) method
, Article 2009 IEEE Power and Energy Society General Meeting, PES '09, 26 July 2009 through 30 July 2009, Calgary, AB ; 2009 ; 9781424442416 (ISBN) ; Fotuhi Firuzabad, M ; Khodaei, A ; Faried, S. O ; Sharif University of Technology
Abstract
Utilization of Unified Power Flow Controllers (UPFCs) can be more beneficial in the restructured power systems due to their capabilities in increasing the transmission line capacities as well as shunt reactive compensation. So, these devices should be installed such that the most benefit can be gained. In this paper, the problem of optimal placement of UPFCs is solved using Mixed-Integer Non-Linear Programming (MINLP) method. Hence, the problem is completely formulated based on this method and is solved using available commercial solvers. The salient feature of this method is having potential to simultaneously determine the optimal location of multi UPFCs. Also, since a full AC Optimal Power...
Optimal PID control of a nano-Newton CMOS-MEMS capacitive force sensor for biomedical applications
, Article Mechanics and Industry ; Vol. 15, issue. 2 , January , 2014 , p. 139-145 ; Ghafari, A. S ; Sharif University of Technology
Abstract
This paper presents closed loop simulation of a CMOS-MEMS force sensor for biomedical applications employing an optimal proportional-integral-derivative controller. Since the dynamic behavior of the sensor under investigation is nonlinear the iterative feedback tuning approach was proposed for optimal gains tuning of the proposed controller. Simulation results presented in this research illustrate that the proposed controller suppresses the undesired in-plane vibration induced by environment or gripper 40 times faster than the nonlinear controller proposed in the literature. To suppress the maximum input disturbance the maximum voltage was approximately 18 V which was less than the pull-in...
Modeling and control of dissolved oxygen concentration in the fermentation of glucose to gluconic acid
, Article Periodica Polytechnica: Chemical Engineering ; Volume 57, Issue 1-2 , 2013 , Pages 63-70 ; 03245853 (ISSN) ; Bamdad, H ; Papari, S ; Yaghmaei, S ; Sharif University of Technology
2013
Abstract
Fermentation systems are often highly nonlinear, with poorly understood dynamic behaviour of the reactor. In this work, mathematical modeling of the fermentation process based on aeration rate control was performed in a semi-batch airlift loop bioreactor. The bioconversion of glucose to gluconic acid by the Aspergillus niger strain was considered in an oxygen consuming system in the liquid phase. The proper kinetic model for the bioconversion of glucose to gluconic acid was investigated using experimental data from a 40 dm3reactor. Kinetic parameter estimation was used from the literature. The model was validated by experimental data and was compared with the Monod kinetic model. The...
Modeling and active control of chatter vibrations of piezoelectric stacked machining arm in micro-turning process
, Article Meccanica ; Volume 55, Issue 9 , 18 July , 2020 , Pages 1707-1731 ; Moradi, H ; Movahhedy, M. R ; Sharif University of Technology
Springer
2020
Abstract
Self-excited vibrations known as chatter are considered as the most detrimental issue in micro-turning processes. Occurring unpredictably, they adversely affect the tool life, productivity rate and surface quality of the machining processes. In this paper, a novel machining arm is modeled as a piezoelectric stacked rod which is subjected to a chatter force in the orthogonal micro-turning process. Due to the fact that machining processes are affected by various sources of uncertainties, H∞ robust control approach is used to suppress the chatter vibrations of the machining arm in the presence of tool wear and dynamic model parameter variations. Also, input control force of the system is...
Location of unified power flow controller and its parameters setting for congestion management in pool market model using genetic algorithm
, Article 2006 International Conference on Power Electronics, Drives and Energy Systems, PEDES '06, New Delhi, 12 December 2006 through 15 December 2006 ; 2006 ; 078039772X (ISBN); 9780780397729 (ISBN) ; Ehsan, M ; Fotuhi Firuzabad, M ; Sharif University of Technology
2006
Abstract
In this paper, AC Optimal Power Flow combined with UPFC has been used to manage the congestion of transmission lines in a restructured power system with pool market model. The modeling of Unified Power Flow Controller (UPFC) has been adopted based on bipolar model and power injection method. To determine an appropriate location for UPFC as well as to set its parameters, an approach based on genetic algorithm has been suggested. The modified IEEE 14-bus system is used to determine the effectiveness and applicability of the proposed method and results are discussed. ©2006 IEEE
Locating and parameters setting of unified power flow controller for congestion management and improving the voltage profile
, Article Asia-Pacific Power and Energy Engineering Conference, APPEEC, 28 March 2010 through 31 March 2010 ; March , 2010 ; 21574839 (ISSN) ; 9781424448135 (ISBN) ; Ehsan, M ; Sharif University of Technology
2010
Abstract
This paper propose a particle swarm optimization based algorithm for locating Unified power flow controller (UPFC), as well as set its parameters, with static point of view in deregulated electricity markets in order to reduce generation cost, voltage violation and manage congestion. The modeling of UPFC has been adapted based on power injection method. In order to verify and validate the effectiveness of the proposed method, it was applied to 24-bus Reliability Test System (RTS) and the results have been discussed
Load-frequency control of interconnected power system using emotional learning-based intelligent controller
, Article International Journal of Electrical Power and Energy Systems ; Volume 36, Issue 1 , March , 2012 , Pages 76-83 ; 01420615 (ISSN) ; Boroushaki, M ; Hosseini, S. H ; Sharif University of Technology
2012
Abstract
In this paper a novel approach based on the emotional learning is proposed for improving the load-frequency control (LFC) system of a two-area interconnected power system with the consideration of generation rate constraint (GRC). The controller includes a neuro-fuzzy system with power error and its derivative as inputs. A fuzzy critic evaluates the present situation, and provides the emotional signal (stress). The controller modifies its characteristics so that the critic's stress is reduced. The convergence and performance of the proposed controller, both in presence and absence of GRC, are compared with those of proportional integral (PI), fuzzy logic (FL), and hybrid neuro-fuzzy (HNF)...
Investigation of switching time and pressure head effects on hydro magnetic micro-pump and flow controller
, Article 2008 Proceedings of the ASME Fluids Engineering Division Summer Conference, FEDSM 2008, 10 August 2008 through 14 August 2008, Jacksonville, FL ; Volume 2 , 2009 , Pages 463-470 ; 9780791848418 (ISBN) ; Shafii, M. B ; Fluids Engineering Division, ASME ; Sharif University of Technology
2009
Abstract
The significant importance of micro-scaled devices in medicine, lab-on-a-chip, and etc resulted in a vast variety of researches. The idea behind the novel hydro magnetic micro-pump and flow controller is that ferromagnetic particles, mixed and dispersed in a carrier fluid, can be accumulated and retained at specific sites to form pistons in a micro-tube using some external magnetic field sources along the micro-tube. This external magnetic field is related to some solenoids, which are turned on and off alternatively. Depending upon dragging speed of these pistons, which itself is a function of switching time, this device can be used to either increase (pumping) or decrease (valving) the flow...