Loading...
Search for: electric-power-system-interconnection
0.007 seconds
Total 36 records

    Reliability study of HV substations equipped with the fault current limiter

    , Article IEEE Transactions on Power Delivery ; Vol. 27, issue. 2 , 2012 , p. 610-617 ; ISSN: 8858977 Fotuhi-Firuzabad, M ; Aminifar, F ; Rahmati, I ; Sharif University of Technology
    Abstract
    Of particular interest to restrict the short-circuit level of interconnected power systems is to exploit fault current limiter (FCL) technologies. FCLs let the system planners devise new reliable and rather economical substation configurations and provide the possibility of proposing a promising cost-effective and prompt solution to the fault current over duty problem in the existing substations. This paper attempts to assess reliability of substation architectures accommodating the FCL operation and, besides, numerically investigates the FCL's impacts on the substation reliability indices. In order to clarify the proposed approach, two case studies with and without FCL are analyzed and... 

    Probabilistic multistage PMU placement in electric power systems

    , Article IEEE Transactions on Power Delivery ; Vol. 26, issue. 2 , 2011 , p. 841-849 ; ISSN: 08858977 Aminifar, F ; Fotuhi-Firuzabad, M ; Shahidehpour, M ; Khodaei, A ; Sharif University of Technology
    Abstract
    This paper presents an optimization model for the calculation of the minimum number of phasor measurement units (PMUs) in electrical power networks. The problem constraint is a predefined probability of observability associated with each bus. The mixed-integer programming is used for the proposed optimization and an efficient linearization technique is proposed to convert the nonlinear function representing the probability of observability into a set of linear expressions. The PMU placement is staged in a multi-year planning horizon due to financial and physical constraints. The average probability of observability is maximized at the intermediate planning stages, subject to a limited number... 

    Observability enhancement by optimal PMU placement considering random power system outages

    , Article Energy Systems ; Vol. 2, issue. 1 , 2011 , p. 45-65 ; ISSN: 18683967 Aminifar, F ; Fotuhi-Firuzabad, M ; Shahidehpour, M ; Khodaei, A ; Sharif University of Technology
    Abstract
    This paper enhances the observability of power networks by taking into consideration random component outages. The architecture of wide-area measurement system (WAMS) is analyzed in order to identify components that would affect the network observability. An iterative framework is devised to calculate a bus index in power networks equipped with phasor measurement units (PMUs) and conventional measurements. The average of bus indices represents a system index which provides an overall insight on the power network observability. The system index is utilized as a criterion to distinguish among multiple optimal PMU placements. Conventional bus injection and line flow measurements and the effect... 

    Reliability modeling of PMUs using fuzzy sets

    , Article IEEE Transactions on Power Delivery ; Vol. 25, issue. 4 , 2010 , p. 2384-2391 ; ISSN: 8858977 Aminifar, F ; Bagheri-Shouraki, S ; Fotuhi-Firuzabad, M ; Shahidehpour, M ; Sharif University of Technology
    Abstract
    Probabilistic analyses of a wide-area measurement system (WAMS) would require equivalent reliability models for its components which include phasor measurement units (PMUs). In this paper, the reliability modeling of PMU is proposed and the proposed model is extended to consider options for the PMU hardware. The Markov process is employed to analyze the proposed model and to present an equivalent two-state model of PMUs. Reliability parameters of PMU are estimated with major difficulties associated with limited and uncertain data. In this paper, uncertainties are taken into account to achieve more realistic estimates of PMU characteristics. Fuzzy sets along with reliability analyses and... 

    Two-level optimal load-frequency control for multi-area power systems

    , Article International Journal of Electrical Power and Energy Systems ; Volume 53, Issue 1 , December , 2013 , Pages 540-547 ; 01420615 (ISSN) Rahmani, M ; Sadati, N ; Sharif University of Technology
    2013
    Abstract
    In large-scale power systems, classical centralized control approaches may fail due to geographically distribution of information and decentralized controllers result in sub-optimal solution for load-frequency control (LFC) problems. In this paper, a two-level structure is presented to obtain optimal solution for LFC problems and also reduce the computational complexity of centralized controllers. In this approach, an interconnected multi-area power system is decomposed into several sub-systems (areas) at the first-level. Then an optimization problem in each area is solved separately, with respect to its local information and interaction signals coming from other areas. At the second-level,... 

    Optimal integration of phasor measurement units in power systems considering conventional measurements

    , Article IEEE Transactions on Smart Grid ; Volume 4, Issue 2 , June , 2013 , Pages 1113-1121 ; 19493053 (ISSN) Azizi, S ; Gharehpetian, G. B ; Dobakhshari, A. S ; Sharif University of Technology
    2013
    Abstract
    This paper presents an integer linear programming (ILP) framework for the optimal placement of phasor measurement units (PMUs), in the presence of conventional measurements. Furthermore, by the proposed method, the power system remains completely observable during all possible single contingencies for lines and measurement devices. In doing so, the potential of circuit equations associated with both PMUs and conventional measurements as well as the network topology are fully utilized by a system of equations to reach the minimum possible numbers of required PMUs. The limitation of communication channels is also taken into account in the proposed ILP-based framework. The method is implemented... 

    Hierarchical optimal robust load-frequency control for power systems

    , Article IET Generation, Transmission and Distribution ; Volume 6, Issue 4 , 2012 , Pages 303-312 ; 17518687 (ISSN) Rahmani, M ; Sadati, N ; Sharif University of Technology
    Abstract
    In this study, a hierarchical optimal robust controller is presented for the power system load-frequency control problem. In this approach, the multi-area power system is first decomposed into several sub-systems (areas). Then by using a two-level control strategy, the overall optimal solution is obtained. At the first level, the optimal control of each area is obtained with respect to local information and also considering interactions coming from other areas. At the second level, by using a coordination strategy, the local controllers will converge to global solution and optimal robust controller is achieved. This approach is applicable to both single-area and multi-area interconnected... 

    Reliability study of HV substations equipped with the fault current limiter

    , Article IEEE Transactions on Power Delivery ; Volume 27, Issue 2 , 2012 , Pages 610-617 ; 08858977 (ISSN) Fotuhi Firuzabad, M ; Aminifar, F ; Rahmati, I ; Sharif University of Technology
    2012
    Abstract
    Of particular interest to restrict the short-circuit level of interconnected power systems is to exploit fault current limiter (FCL) technologies. FCLs let the system planners devise new reliable and rather economical substation configurations and provide the possibility of proposing a promising cost-effective and prompt solution to the fault current over duty problem in the existing substations. This paper attempts to assess reliability of substation architectures accommodating the FCL operation and, besides, numerically investigates the FCL's impacts on the substation reliability indices. In order to clarify the proposed approach, two case studies with and without FCL are analyzed and... 

    Load-frequency control of interconnected power system using emotional learning-based intelligent controller

    , Article International Journal of Electrical Power and Energy Systems ; Volume 36, Issue 1 , March , 2012 , Pages 76-83 ; 01420615 (ISSN) Farhangi, R ; Boroushaki, M ; Hosseini, S. H ; Sharif University of Technology
    2012
    Abstract
    In this paper a novel approach based on the emotional learning is proposed for improving the load-frequency control (LFC) system of a two-area interconnected power system with the consideration of generation rate constraint (GRC). The controller includes a neuro-fuzzy system with power error and its derivative as inputs. A fuzzy critic evaluates the present situation, and provides the emotional signal (stress). The controller modifies its characteristics so that the critic's stress is reduced. The convergence and performance of the proposed controller, both in presence and absence of GRC, are compared with those of proportional integral (PI), fuzzy logic (FL), and hybrid neuro-fuzzy (HNF)... 

    Application of intelligence-based predictive scheme to load-frequency control in a two-area interconnected power system

    , Article Applied Intelligence ; Volume 35, Issue 3 , 2011 , Pages 457-468 ; 0924669X (ISSN) Mazinan, A. H ; Hosseini, A. H ; Sharif University of Technology
    2011
    Abstract
    This paper describes an application of intelligence- based predictive scheme to load-frequency control (LFC) in a two-area interconnected power system. In this investigation, at first, a dynamic model of the present system has to be considered and subsequently an efficient control scheme which is organized based on Takagi-Sugeno-Kang (TSK) fuzzy-based scheme and linear generalized predictive control (LGPC) scheme needs to be developed. In the control scheme proposed, frequency deviation versus load electrical power variation could efficiently be dealt with, at each instant of time. In conclusion, in order to validate the effectiveness of the proposed control scheme, the whole of outcomes are... 

    Probabilistic multistage PMU placement in electric power systems

    , Article IEEE Transactions on Power Delivery ; Volume 26, Issue 2 , December , 2011 , Pages 841-849 ; 08858977 (ISSN) Aminifar, F ; Fotuhi Firuzabad, M ; Shahidehpour, M ; Khodaei, A ; Sharif University of Technology
    2011
    Abstract
    This paper presents an optimization model for the calculation of the minimum number of phasor measurement units (PMUs) in electrical power networks. The problem constraint is a predefined probability of observability associated with each bus. The mixed-integer programming is used for the proposed optimization and an efficient linearization technique is proposed to convert the nonlinear function representing the probability of observability into a set of linear expressions. The PMU placement is staged in a multi-year planning horizon due to financial and physical constraints. The average probability of observability is maximized at the intermediate planning stages, subject to a limited number... 

    Observability enhancement by optimal PMU placement considering random power system outages

    , Article Energy Systems ; Volume 2, Issue 1 , 2011 , Pages 45-65 ; 18683967 (ISSN) Aminifar, F ; Fotuhi Firuzabad, M ; Shahidehpour, M ; Khodaei, A ; Sharif University of Technology
    Abstract
    This paper enhances the observability of power networks by taking into consideration random component outages. The architecture of wide-area measurement system (WAMS) is analyzed in order to identify components that would affect the network observability. An iterative framework is devised to calculate a bus index in power networks equipped with phasor measurement units (PMUs) and conventional measurements. The average of bus indices represents a system index which provides an overall insight on the power network observability. The system index is utilized as a criterion to distinguish among multiple optimal PMU placements. Conventional bus injection and line flow measurements and the effect... 

    Performance improvement of steady-state and transient operation of offshore wind farm HVDC power transmission

    , Article 2015 IEEE 16th Workshop on Control and Modeling for Power Electronics, COMPEL 2015, 12 July 2015 through 15 July 2015 ; July , 2015 , Page(s): 1 - 7 ; 9781467368476 (ISBN) Safaeian, R ; Ebrahimi, S ; Parniani, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    Wind power generation is increasing fast as a clean renewable energy resource. Offshore wind farms are popular due to advantages such as higher and smoother wind speeds, less farm site limitations, etc. High capacitive currents and need to expensive compensations, make use of high-voltage-direct-current (HVDC) power transmission indispensable for longdistance wind farm power generations. Steady-state and transient performance improvements of HVDC systems have always been an interesting industrial and academic research area. In this paper, a novel control method is proposed to improve the steady-state operation of HVDC system. Moreover, a new fault detection scheme is proposed to improve the... 

    Developing a stochastic framework to determine the static reserve requirements of high-wind penetrated power systems

    , Article Journal of Intelligent and Fuzzy Systems ; Volume 29, Issue 5 , 2015 , Pages 2039-2046 ; 10641246 (ISSN) Riahinia, S ; Abbaspour, A ; Fotuhi Firuzabad, M ; Moeini Aghtaie, M ; Sharif University of Technology
    IOS Press  2015
    Abstract
    Operational and planning studies of high-wind penetrated power systems have well come to the light as a major concern of future energy systems. This paper focuses on the procedure of determining required static reserve of the high-wind penetrated power systems which has not been well accompanied by comprehensive analysis and proper modeling tools. To reach this goal, first, a probabilistic algorithm has been proposed to effectively model the variations in output generation of wind turbines. In this algorithm, the fuzzy c-means clustering method (FCM) is exploited as an efficient as well as robust clustering method to find the multi-state model of wind turbines output generation. Based on... 

    Reliability improvement of power system utilizing BESS with wind farm

    , Article 2015 IEEE 15th International Conference on Environment and Electrical Engineering, EEEIC 2015 - Conference Proceedings, 10 June 2015 through 13 June 2015 ; 2015 , Pages 1120-1125 ; 9781479979936 (ISBN) Shahooei, Z ; Fotuhi-Firuzabad, M ; Abbaspour, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    In this paper, the effect of wind power generation on power system reliability is investigated. Furthermore, reliability improvement of power system using integrated battery energy storage system and wind farm will be evaluated. Growing demand for electrical energy, gradual diminishing of fossil fuel resources and environmental pollution due to continuous exploitation of them, have led to inevitable change of energy sources in power generation. Due to the random nature of wind speed, the power output of a wind farm is fluctuating; as a result, it does not have a proper control capability. The growing penetration of wind power generation in power system could cause various problems in... 

    Optimal unified power flow controller application to enhance total transfer capability

    , Article IET Generation, Transmission and Distribution ; Volume 9, Issue 4 , 2015 , Pages 358-368 ; 17518687 (ISSN) Rajabi Ghahnavieh, A ; Fotuhi Firuzabad, M ; Othman, M ; Sharif University of Technology
    Institution of Engineering and Technology  2015
    Abstract
    For a power transfer path, total transfer capability (TTC) represents maximum power that can be transferred over the transmission system. Unified power flow controller (UPFC) is a device that can be used to increase in TTC. This study presents a new method for optimal UPFC application to minimise power loss while enhancing TTC. Based on UPFC injection model, the solution region of UPFC parameters is first found using the proposed method to maximise TTC. It then searches the solution region to find optimal UPFC control mode and setting to minimise system power loss. The proposed method is applied to the IEEE-Reliability Test System and the UPFC application impact are evaluated. Comparative... 

    Modeling, control and islanding detection of microgrids with passive loads

    , Article Proceedings of EPE-PEMC 2010 - 14th International Power Electronics and Motion Control Conference, 6 September 2010 through 8 September 2010 ; September , 2010 , Pages T11107-T11112 ; 9781424478545 (ISBN) Popov, M ; Karimi, H ; Nikkhajoei, H ; Terzija, V ; Sharif University of Technology
    2010
    Abstract
    This paper presents a control scheme for microgrids with passive loads. The existing control techniques for distributed generation systems are designed to operate either in the grid-connected or in the islanded mode. In the grid-connected mode of operation, a currentcontrolled scheme based on d-q variables is used for the regulation of real and reactive powers of the converter. In the islanded mode of operation, the converter is controlled in the voltage-controlled mode. This paper deals with the modeling of both control schemes. Furthermore, reconnection from the islanded mode to the grid-connected mode based on the use of adequate Phase-Locked Loops (PLLs) has been demonstrated  

    Reliability modeling of PMUs using fuzzy sets

    , Article IEEE Transactions on Power Delivery ; Volume 25, Issue 4 , August , 2010 , Pages 2384-2391 ; 08858977 (ISSN) Aminifar, F ; Bagheri Shouraki, S ; Fotuhi Firuzabad, M ; Shahidehpour, M ; Sharif University of Technology
    2010
    Abstract
    Probabilistic analyses of a wide-area measurement system (WAMS) would require equivalent reliability models for its components which include phasor measurement units (PMUs). In this paper, the reliability modeling of PMU is proposed and the proposed model is extended to consider options for the PMU hardware. The Markov process is employed to analyze the proposed model and to present an equivalent two-state model of PMUs. Reliability parameters of PMU are estimated with major difficulties associated with limited and uncertain data. In this paper, uncertainties are taken into account to achieve more realistic estimates of PMU characteristics. Fuzzy sets along with reliability analyses and... 

    An analytical framework for operational reliability studies of highly wind integrated power systems

    , Article 2016 International Conference on Probabilistic Methods Applied to Power Systems, PMAPS 2016 - Proceedings, 16 October 2016 through 20 October 2016 ; 2016 ; 9781509019700 (ISBN) Parvini, Z ; Abbaspour, A ; Fotuhi Firuzabad, M ; Moeini Aghtaie, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2016
    Abstract
    This paper presents a new framework for evaluating contribution of wind farms in operational reliability level of power systems. In this regard, at first, it provides a short-term analytical model well designed to represent intermittent and uncertain nature of wind power. Combining the attained multi-state model of wind farms with the other committed generating units, operational risk of the system is evaluated. The concept of Pennsylvania-New Jersey-Maryland (PJM), previously developed to assess the short-term/mid-term reliability of conventional generating units, is revisited in this paper to more practically incorporate wind farms in reliability studies of the power system. The proposed... 

    Plug-in hybrid electric vehicle battery charger with soft-switched dual-bridge resonant converter for smart grid applications

    , Article 7th IEEE International Symposium on Power Electronics for Distributed Generation Systems, PEDG 2016, 27 June 2016 through 30 June 2016 ; 2016 ; 9781467386166 (ISBN) Akbari, R ; Ebrahimi, S ; Tahami, F ; Oraee, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2016
    Abstract
    Battery chargers are fundamental components for successful deployment of plug-in hybrid electric vehicles (PHEVs) into future smart grid. Recently, an integrated isolated bidirectional battery charger has been proposed for PHEV applications. The proposed charger eliminates the conventional bulky dc-link capacitor by feeding a dual-bridge resonant tank directly from the three-phase grid. The disadvantages associated with the presented charger are the high number of semiconductor switches which contribute to high cost and switching losses of converter as well as complicated control circuitry. In this paper, the previous structure is modified to address the aforementioned drawbacks and is...