Loading...
Search for: electric-power-systems
0.016 seconds
Total 213 records

    Harmonic filter design consideration for a Tire-Rubber factory

    , Article 5th IASTED International Conference on Power and Energy Systems, EuroPES 2005, Benalmadena, 15 June 2005 through 17 June 2005 ; 2005 , Pages 380-383 ; 14827891 (ISSN) Zebardast, A ; Mokhtari, H ; Hamza M. H ; IASTED ; Sharif University of Technology
    2005
    Abstract
    Increase in the number of non-linear loads has increased harmonic pollution in industries, resulting in lower power factor and more losses. Harmonics may also lead to adverse conditions in cases they match a resonance frequency existing in the system. To alleviate the problems of harmonics, tuned harmonic filters are used. However, design and installation of passive elements in power systems or industries requires special attentions due to the possible resonances that may occur. In this paper, a Tire-Rubber company is analyzed for a filter installation. Harmonic analysis is performed, and site measurements are examined. Cautions to be taken for design consideration are then discussed  

    A comprehensive digital protection scheme for low-voltage microgrids with inverter-based and conventional distributed generations

    , Article IEEE Transactions on Power Delivery ; Volume 32, Issue 1 , 2017 , Pages 441-452 ; 08858977 (ISSN) Zarei, S. F ; Parniani, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    Microgrid (MG) protection is one of the main challenges in proliferation of microgrids. Due to limited fault current feeding of inverter-based distributed generations (DGs), in islanded operation of MG, protection problems become more complicated; and, therefore, conventional protection strategies cannot be applied. Hence, new protection methods that are applicable in islanded and grid-connected modes of operation are necessary. In this paper, a comprehensive digital-relay based protection is introduced for the protection of MGs. The proposed method includes protection of lines, distributed generations, and the point of common coupling. The structure and graphical schematic of the proposed... 

    Enhanced control of grid forming VSCs in a micro-grid system under unbalanced conditions

    , Article 9th Annual International Power Electronics, Drive Systems, and Technologies Conference, PEDSTC 2018, 13 February 2018 through 15 February 2018 ; Volume 2018-January , April , 2018 , Pages 380-385 ; 9781538646977 (ISBN) Zarei, S. F ; Mokhtari, H ; Ghasemi, M. A ; SHarif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    Due to the technical advances in power electronic industry, employing inverter-based distributed energy resources (IBDERs) are increased in electric power systems. Distributed generators (DGs) with the rating capacity of few megawatts are commonly connected to the distribution level of power systems which are inherently unbalanced. A cluster of IBDERs and loads form a small-scale grid called microgrid (MG) which can operate independent of the main grid. In a MG, grid forming voltage source converters (VSCs) are used to control the voltages and frequency of the MG. However, grid forming VSCs with conventional control schemes cannot do this task properly when the MG is unbalanced. In this... 

    Reinforcing fault ride through capability of grid forming voltage source converters using an enhanced voltage control scheme

    , Article IEEE Transactions on Power Delivery ; Volume 34, Issue 5 , 2019 , Pages 1827-1842 ; 08858977 (ISSN) Zarei, S. F ; Mokhtari, H ; Ghasemi, M. A ; Blaabjerg, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Medium power distributed energy resources (DERs) are commonly connected to medium voltage distribution systems via voltage source converters (VSCs). Several guidelines and standards have been developed to establish the needed criteria and requirements for DERs interconnections. In this respect, it is preferred to reinforce the VSC fault ride through (FRT) capability, which considerably minimizes the DG outage period and reconnection time and results in a resilient system against short circuits. Considering the significant number of asymmetrical faults in distribution systems, the VSC response in such conditions must be investigated, and consequently, its FRT capability must be reinforced. In... 

    Power delivery solutions in 3-D processor-DRAM systems in presence of hot spots

    , Article 2014 IEEE 23rd Conference on Electrical Performance of Electronic Packaging and Systems, EPEPS 2014, 26 October 2014 through 29 October 2014 ; Oct , 2014 , Pages 207-210 ; 9781479936410 (ISBN) Zabihi, M ; Radfar, F ; Sarvari, R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2014
    Abstract
    An important application of 3-D integration technology is stacked processor-DRAM systems. One of the major design issues in 3-D processor-DRAM stacks is power delivery. Presence of hot spots, high density power regions, in processor die poses serious challenges to the design of power distribution network (PDN). In this paper, we investigate solutions to ensure power integrity in the hot spot regions  

    An input-to-state stability approach to inertial frequency response analysis of doubly-fed induction generator-based wind turbines

    , Article IEEE Transactions on Energy Conversion ; Volume 32, Issue 4 , 2017 , Pages 1418-1431 ; 08858969 (ISSN) Toulabi, M ; Bahrami, S ; Ranjbar, A. M ; Sharif University of Technology
    Abstract
    Due to the proliferation of wind turbines in power networks, participation of doubly-fed induction generator (DFIG)-based wind turbines in the frequency regulation task is attracting more attention during recent decades. It is a challenge to design an effective DFIG's auxiliary frequency controller, since back-to-back converters used in DFIG make the possibility of large deviations in current and speed of rotor during frequency support period. Hence, it is necessary to use exact expression of DFIG's output power in the frequency-related studies. This paper addresses this challenge by developing a nonlinear dynamic model for the DFIG's output power integrated into the dynamic model of power... 

    Application of edge theorem for robust stability analysis of a power system with participating wind power plants in automatic generation control task

    , Article IET Renewable Power Generation ; Volume 11, Issue 7 , 2017 , Pages 1049-1057 ; 17521416 (ISSN) Toulabi, M ; Bahrami, S ; Ranjbar, A. M ; Sharif University of Technology
    Institution of Engineering and Technology  2017
    Abstract
    This study investigates the dynamic participation of wind power plants (WPPs) in the automatic generation control (AGC) task. The pre-specified model of wind farm in the AGC studies has been used. It is shown that operating of WPPs at the command mode results in a significant improvement in the frequency behaviour of power system due to their faster response. However, the WPPs may change their operation mode from the command mode to the maximum power point mode according to the wind speed conditions and load variations. This reduces the improvement in the frequency response. In this condition, the shortage in the wind power should be compensated by the conventional units. Thus, the share of... 

    Application of bang-bang controller to emulate primary frequency response in DFIGs

    , Article IEEE Systems Journal ; Volume 14, Issue 2 , 2020 , Pages 2615-2623 Toulabi, M ; Ashouri Zadeh, A ; Kazari, H ; Ranjbar, A. M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    This article proposes a bang-bang auxiliary frequency control scheme for doubly-fed induction generator (DFIG)-based wind turbines. It results in the DFIGs emulate the primary frequency control of conventional units and, thus, increases the power system frequency stability. Indeed, the suggested hysteresis controller causes to deliver the maximum extractable kinetic energy of DFIGs to the grid and consequently further enhance the power system frequency. This is accomplished using different frequency deviation indices, which determine the size of power mismatch and lead to an appropriate frequency response by the DFIGs. The operational constraints of the DFIGs are taken into account in the... 

    Influence of model simplifications and parameters on dynamic performance of grid connected fixed speed wind turbines

    , Article 19th International Conference on Electrical Machines, ICEM 2010, 6 September 2010 through 8 September 2010, Rome ; 2010 ; 9781424441754 (ISBN) Tohidi, S ; Rabiee, A ; Parniani, M ; Sharif University of Technology
    2010
    Abstract
    With the rising penetration of wind power into electric power systems, more accurate and comprehensive studies are required to identify the interaction between wind farm(s) and power system. This requires accurate models of different types of wind turbine-generators. This paper describes modeling and small signal analysis of a grid connected fixed speed wind turbine generator (FSWTG). A complete model of FSWTG is derived and some reduced-order models are deduced. Eigenvalues and participation factors of the system for these models are calculated. Then, using the eigen analysis results, the models are compared and the simplifying assumptions which have been considered in the literatures are... 

    Decentralized active power management in multi-agent distribution systems considering congestion issue

    , Article IEEE Transactions on Smart Grid ; Volume 13, Issue 5 , 2022 , Pages 3582-3593 ; 19493053 (ISSN) Tofighi Milani, M ; Fattaheian Dehkordi, S ; Fotuhi Firuzabad, M ; Lehtonen, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2022
    Abstract
    Recently, due to the restructuring of power systems and the high penetration level of local renewables, distribution systems have encountered with the complexity of power management. Therefore, the modern systems would be operated in a multi-agent structure which facilitates the power management as well as privacy protections of independent entities. In this structure, the distribution system is assumed to compose of several agents who independently schedule their local resources in order to maximize their own profits. Consequently, this paper provides an efficient peer-to-peer (P2P) active power management framework in a multi-agent distribution system while considering network constraints... 

    Design & implementation of a high precision & high dynamic range power consumption measurement system for smart energy IoT applications

    , Article Measurement: Journal of the International Measurement Confederation ; Volume 146 , 2019 , Pages 458-466 ; 02632241 (ISSN) Tehrani, Y. H ; Atarodi, S. M ; Sharif University of Technology
    Elsevier B.V  2019
    Abstract
    Internet of Things (IoT) devices have strict necessity for power consumption in order to achieve expected battery life. IoT nodes feature extreme power consumption range over 100 dB, between their operating modes. The main focus of this paper is to design and implement a high precision, high dynamic range, low power, and flexible power measurement system, which can be applied to different applications. The proposed system consists of a voltage regulating control loop, zero offset amplifiers, high precision analog to digital converters, and reference voltage. The proper operation of the proposed circuit are verified numerically with simulations and experimental measurements. The implemented... 

    Comments on 'fixed-time backstepping fractional-order sliding mode excitation control for performance improvement of power system'

    , Article IEEE Transactions on Circuits and Systems I: Regular Papers ; Volume 69, Issue 8 , 2022 , Pages 3461-3462 ; 15498328 (ISSN) Tavazoei, M. S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2022
    Abstract
    In this note, it is shown that the Lyapunov function-based analyses done in the above-titled article to design a backstepping sliding mode controller contain some drawbacks. These drawbacks include ignoring some terms in simplification of time-derivative of the considered Lyapunov functions, which do not vanish in a finite-time. Moreover, by presenting a counterexample, it is revealed that the finite-time convergence of the error signals cannot be necessarily concluded from a Lyapunov function-based inequality used in the aforementioned article. © 2004-2012 IEEE  

    Welfare-aware strategic demand control in an intelligent market-based framework: Move towards sustainable smart grid

    , Article Applied Energy ; Volume 251 , 2019 ; 03062619 (ISSN) Taheri Tehrani, M ; Afshin Hemmatyar, A. M ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    To address sustainability challenges appeared in today's power grids, it is essential for emerging demand control paradigm to be adapted more to the lifestyle of the customers. In this paper, due to the ever-growing interconnectivity of the grids, a distributed Commodity Market (CM) framework is proposed in which intelligent agents embedded inside of customers want to maximize their preferred welfare through real-time demand of power from an energy market. Since there is not a comprehensive model for the grids, utilizing Reinforcement Learning (RL) proves that the global optimal performance is achieved in the Nash Equilibrium (NE) of the proposed framework. This solution not only maximizes... 

    Toward operational resilience of smart energy networks in complex infrastructures

    , Article Advances in Intelligent Systems and Computing ; Volume 1123 , 2020 , Pages 203-228 Taheri, B ; Jalilian, A ; Safdarian, A ; Moeini Aghtaie, M ; Lehtonen, M ; Sharif University of Technology
    Springer  2020
    Abstract
    Smart energy systems can mitigate electric interruption costs provoked by manifold disruptive events via making efforts toward proper pre-disturbance preparation and optimal post-disturbance restoration. In this context, effective contingency management in power distribution networks calls for contemplating disparate parameters from interconnected electric and transportation systems. This chapter, while considering transportation issues in power networks’ field operations, presents a navigation system for pre-positioning resources such as field crews and reconfiguring the network to acquire a more robust configuration in advance of the imminent catastrophe. Also, after the occurrence of the... 

    Synthesis of composite coating containing tio2 and ha nanoparticles on titanium substrate by ac plasma electrolytic oxidation

    , Article Metallurgical and Materials Transactions A: Physical Metallurgy and Materials Science ; Volume 50, Issue 7 , 2019 , Pages 3310-3319 ; 10735623 (ISSN) Soleymani Naeini, M ; Ghorbani, M ; Chambari, E ; Sharif University of Technology
    Springer Boston  2019
    Abstract
    In this study, biocompatible ceramic layers containing TiO2 and hydroxyapatite (HA) nanoparticles (TiO2/HA) were deposited on pure commercial titanium (Grade 2) by using plasma electrolytic oxidation and AC power supply. The coating process was carried out in five different solutions for various times at a current density of 500 mA cm−2. To achieve the optimum conditions for thickness and microstructure, the coating process was conducted in solutions with a 3 g L−1 concentration of HA nanoparticles. FESEM, XRD, and FTIR results showed that HA nanoparticles were successfully incorporated into the pores of the layer. Furthermore, the corrosion behavior of the coating layers in the simulated... 

    Strategic bidding of generating units in competitive electricity market with considering their reliability

    , Article International Journal of Electrical Power and Energy Systems ; Volume 30, Issue 3 , 2008 , Pages 193-201 ; 01420615 (ISSN) Soleymani, S ; Ranjbar, A. M ; Shirani, A. R ; Sharif University of Technology
    2008
    Abstract
    In the restructured power systems, they are typically scheduled based on the offers and bids to buy and sell energy and ancillary services (AS) subject to operational and security constraints. Generally, no account is taken of unit reliability when scheduling it. Therefore generating units have no incentive to improve their reliability. This paper proposes a new method to obtain the equilibrium points for reliability and price bidding strategy of units when the unit reliability is considered in the scheduling problem. The proposed methodology employs the supply function equilibrium (SFE) for modeling a unit's bidding strategy. Units change their bidding strategies and improve their... 

    Coordinated control of doubley fed induction generator virtual inertia and power system oscillation damping using fuzzy logic

    , Article International Journal of Engineering, Transactions A: Basics ; Volume 32, Issue 4 , 2019 , Pages 536-547 ; 17281431 (ISSN) Solat, A. R ; Ranjbar, A. M ; Mozafari, B ; Sharif University of Technology
    Materials and Energy Research Center  2019
    Abstract
    Doubly-fed induction generator (DFIG) based wind turbines with traditional maximum power point tracking (MPPT) control provide no inertia response under system frequency events. Recently, the DFIG wind turbines have been equipped with virtual inertia controller (VIC) for supporting power system frequency stability. However, the conventional VICs with fixed gain have negative effects on inter-area oscillations of regional networks. To cope with this drawback, this paper proposes a novel adaptive VIC to improve both the inter-area oscillations and frequency stability. In the proposed scheme, the gain of VIC is dynamically adjusted using fuzzy logic. The effectiveness and control performance of... 

    A comparative study on fuzzy damping controller for DFIG wind farms to improve power system oscillations

    , Article Journal of Intelligent and Fuzzy Systems ; Volume 37, Issue 4 , 2019 , Pages 4965-4978 ; 10641246 (ISSN) Solat, A ; Ranjbar, A. M ; Mozafari, B ; Sharif University of Technology
    IOS Press  2019
    Abstract
    Doubly-fed induction generator (DFIG) is the most commonly used technology for wind power generation due to the variable speed performance, decoupled control of active and reactive powers, and high efficiency. However, the DFIG originally cannot participate in damping of power system oscillations since it is not synchronously connected to the power system. This paper proposes an optimal and robust additional damping controller for the DFIG wind turbine to contribute it to damp power system oscillations. It is a fuzzy logic controller that its parameters are optimally tuned using the genetic algorithm (GA). The proposed controller modifies the DFIG active power output by using feedback from... 

    Economic evaluation of micro-turbines in Iranian electric industry

    , Article 2007 IEEE Lausanne POWERTECH, Lausanne, 1 July 2007 through 5 July 2007 ; 2007 , Pages 1776-1779 ; 9781424421909 (ISBN) Siahkali, H ; Sharif University of Technology
    2007
    Abstract
    Today the electric utility industry is being restructured from monopoly and regulated structure to competitive and deregulated structure. Changes in electricity markets, in technology, economics and regulatory structures have created a new interest in small-scale generation and efficiency resources, dispersed throughout the lower voltage networks. Many reasons have been developed and encouraged using DG (Distributed Generation) in different countries such as power system restructuring, DG technologies advances and price increases. The most important problems of many developing countries is the high cost of finance and limited access to financial resources because of the electric industry is... 

    Integrating large scale wind farms in fuzzy mid term unit commitment using PSO

    , Article 2008 5th International Conference on the European Electricity Market, EEM, Lisboa, 28 May 2008 through 30 May 2008 ; 2008 ; 9781424417445 (ISBN) Siahkali, H ; Vakilian, M ; Sharif University of Technology
    2008
    Abstract
    This paper presents a new approach for unit commitment (UC); where a large scale wind power exists and the wind speed has a fuzzy characteristic; by using particle swarm optimization method (PSO). In this approach, the system reserve requirements, the requirement of having a load balance, and the wind power availability constraints are realized. A proper modeling of these constraints is an important issue in power system scheduling. Since these constraints are "fuzzy" in nature, any crisp treatment of them in this problem may lead to over conservative solutions. In this paper, a fuzzy optimization-based method is developed to solve power system UC problem with a fuzzy objective function and...