Loading...
Search for: electric-relays
0.011 seconds
Total 23 records

    Power allocation in the energy harvesting full-duplex Gaussian relay channels

    , Article International Journal of Communication Systems ; Volume 30, Issue 2 , 2017 ; 10745351 (ISSN) Feghhi, M. M ; Mirmohseni, M ; Abbasfar, A ; Sharif University of Technology
    John Wiley and Sons Ltd  2017
    Abstract
    In this paper, we propose a general model to study the full-duplex non-coherent (NC) decode-and-forward Gaussian relay channel (RC) with energy harvesting (EH) nodes, called NC-EH-RC, in three cases: (i) no energy transfer (ET), (ii) one-way ET from the source (S) to the relay (R), and (iii) two-way ET. We consider the problem of optimal power allocation in NC-EH-RC in order to maximize the total transmitted bits from S to the destination in a given time duration. General stochastic energy arrivals at S and R with known EH times and values are assumed. In NC-EH-RC with no ET, the complicated min-max optimization form along with its constraints make the problem intractable. It is shown that... 

    Relay logic for islanding detection in active distribution systems

    , Article IET Generation, Transmission and Distribution ; Volume 9, Issue 12 , August , 2015 , Pages 1254-1263 ; 17518687 (ISSN) Vatani, M ; Amraee, T ; Ranjbar, A. M ; Mozafari, B ; Sharif University of Technology
    Institution of Engineering and Technology  2015
    Abstract
    This study presents a passive model to detect islanding conditions of synchronous distributed generation resources in a distribution network or a microgrid. The proposed approach uses the classification and regression tree algorithm for distinguishing between islanding and non-islanding situations. It utilises the rate of change of frequency (ROCOF) and harmonic content of the equivalent reactance seen at the location of distributed generation as input features for decision tree construction. Indeed the thresholds of the proposed input features are extracted by the decision tree algorithm. The output if-then rules of the decision tree algorithm are then utilised to make a new relay logic for... 

    Current-Transformer Saturation Compensation for Transformer Differential Relays

    , Article IEEE Transactions on Power Delivery ; Volume 30, Issue 5 , 2015 , Pages 2293-2302 ; 08858977 (ISSN) Hajipour, E ; Vakilian, M ; Sanaye-Pasand, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    Current-transformer (CT) saturation threatens accurate discrimination between internal fault current and magnetizing inrush current of a transformer and endangers the proper operation of a differential relay. Thus, compensation of CT saturation could substantially improve the performance and security of transformer differential relays. So far, almost all of the technical literature in this field has focused exclusively on fault current compensation. However, this paper proposes an efficient compensation algorithm to reconstruct the fault and inrush currents which are distorted by CT saturation. Some of the attractive features of the proposed method are its accuracy, fast response time,... 

    On the capacity region of asymmetric gaussian two-way line channel

    , Article IEEE Transactions on Communications ; Volume 64, Issue 9 , 2016 , Pages 3669-3682 ; 00906778 (ISSN) Ghasemi Goojani, S ; Karimi Bidhendi, S ; Behroozi, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2016
    Abstract
    Lattice codes are known to outperform random codes for certain networks, especially in the Gaussian two-way relay channels (GTWRCs) where lattice codes are able to exploit their linearity. As an extension of the GTWRC, in this paper, we consider the asymmetric Gaussian two-way line network where two nodes exchange their messages through multiple relays. We first investigate the capacity region of the full-duplex two-way two-relay line network. The results can be extended to an arbitrary number of relays and to half-duplex scenarios. This channel consists of four nodes: 1 ↔ 2 ↔ 3 ↔ 4, where nodes 1 and 4 with the help of two full-duplex relays, i.e., nodes 2 and 3, exchange their messages... 

    A comprehensive digital protection scheme for low-voltage microgrids with inverter-based and conventional distributed generations

    , Article IEEE Transactions on Power Delivery ; Volume 32, Issue 1 , 2017 , Pages 441-452 ; 08858977 (ISSN) Zarei, S. F ; Parniani, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    Microgrid (MG) protection is one of the main challenges in proliferation of microgrids. Due to limited fault current feeding of inverter-based distributed generations (DGs), in islanded operation of MG, protection problems become more complicated; and, therefore, conventional protection strategies cannot be applied. Hence, new protection methods that are applicable in islanded and grid-connected modes of operation are necessary. In this paper, a comprehensive digital-relay based protection is introduced for the protection of MGs. The proposed method includes protection of lines, distributed generations, and the point of common coupling. The structure and graphical schematic of the proposed... 

    State-dependent multiple access relay channel with cooperating transmitters

    , Article 2018 Iran Workshop on Communication and Information Theory, IWCIT 2018, 25 April 2018 through 26 April 2018 ; 2018 , Pages 1-6 ; 9781538641491 (ISBN) Gholipour, J ; Mirmohseni, M ; Seyfe, B ; Aref, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    In this paper, we consider a state-dependent multiple access relay channel (MARC) with two-way cooperation at transmitters, in which the transmitters cooperate with each other over two limited-rate channels. We derive an achievable rate region for this channel by using block-Markov superposition coding, and double binning techniques. In our proposed scheme, the relay decodes only parts of the messages which are shared between the transmitters. © 2018 IEEE  

    Transformer turn-to-turn fault protection based on fault-related incremental currents

    , Article IEEE Transactions on Power Delivery ; Volume 34, Issue 2 , 2019 , Pages 700-709 ; 08858977 (ISSN) Farzin, N ; Vakilian, M ; Hajipour, E ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Winding turn-to-turn fault (TTF) is one of the most reported reasons for transformer unplanned outage. If its occurrence is not detected at an early stage, it can develop into a costly phase-to-ground fault. In this paper, a novel algorithm based on the fault-related incremental currents is proposed to detect a low-level transformer TTF. This paper shows that the performance of the proposed method is independent of the transformer operating condition. Therefore, it is reliable even under the presence of power system transients such as the external faults. In addition, the proposed algorithm can be configured uniquely and easily. This feature prevents the algorithm from unnecessary trips.... 

    A lattice-based compress-and-forward strategy for Gaussian two-way relay channel with direct links

    , Article IEEE Wireless Communications Letters ; Volume 5, Issue 5 , 2016 , Pages 500-503 ; 21622337 (ISSN) Ghasemi Goojani, S ; Mardani, S ; Behroozi, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc 
    Abstract
    In this letter, the Gaussian two-way relay channel with direct links is investigated in which two users aim at exchanging their messages with the help of a relay node. We propose a new lattice-based compress-and-forward strategy and obtain its achievable rate-region. We show that the proposed scheme is superior to all previously known achievable schemes for channel gains larger than one. In particular, under the symmetric case, the proposed scheme is able to achieve a capacity region within 0.5 bit or (1/2)log 3 ≅ 0.79 bit, depending on the power of the relay  

    A new wavelet-based method for detection of high impedance faults

    , Article 2005 International Conference on Future Power Systems, Amsterdam, 16 November 2005 through 18 November 2005 ; Volume 2005 , 2005 ; 9078205024 (ISBN); 9789078205029 (ISBN) Mokhtari, H ; Aghatehrani, R ; Sharif University of Technology
    IEEE Computer Society  2005
    Abstract
    Detecting high impedance faults is one of the challenging issues for electrical engineers. Over-current relays can only detect some of the high impedance faults. Distance relays are unable to detect faults with impedance over 100Ω. In this paper, by using an accurate model for high impedance faults, a new wavelet-based method is presented. The proposed method, which employs a 3 level neural network system, can successfully differentiate high impedance faults from other transients. The paper also thoroughly analyzes the effect of choice of mother wavelet on the detection performance. Simulation results which are carried out using PSCAD/EMTDC software are summarized  

    A novel algorithm to identify power swing based on superimposed measurements

    , Article 2012 11th International Conference on Environment and Electrical Engineering, EEEIC 2012 - Conference Proceedings ; 2012 , Pages 1109-1113 ; 9781457718281 (ISBN) Afzali, M ; Esmaeilian, A ; Sharif University of Technology
    IEEE  2012
    Abstract
    This paper describes a novel adaptive out-of-step detection algorithm based on dissimilar measurement approaches. Two superimposed measurements enable the algorithm to detect fast as well as slow power swings. Both methods recognize power swings right from the beginning of the swing impedance movement. The first principle is based on continuous rate-of-change measurement of the traveling swing impedance. The second method continuously monitors the speed and the shape of the swing impedance trajectory. The algorithm detects extremely high swing frequencies of up to 7 Hz and maintains functionality under single-pole open conditions, i.e. auto-reclose dead time. The associated distance relay... 

    Practical implementation of a new percentage-based turn-to-turn fault detection algorithm to transformer digital differential relay

    , Article International Journal of Electrical Power and Energy Systems ; Volume 121 , 2020 Farzin, N ; Vakilian, M ; Hajipour, E ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    Turn-to-turn fault (TTF) is one of the most prominent reasons for transformer failure. This fault typically initiates by involving only a few turns and can progress to a much more severe fault in a very short time. Therefore, it is critical for the transformer protective relays to detect the TTF in the early stages of its occurrence. The conventional differential relays, in general, cannot detect a minor TTF, and thus, a supplementary protective algorithm is usually required to improve the sensitivity of differential relays against TTFs. This paper proposes a percentage-based fault-related incremental currents method for the precise detection of a low-level TTF. The proposed method employs... 

    A reliability model for overcurrent relays considering harmonic-related malfunctions

    , Article International Journal of Electrical Power and Energy Systems ; Volume 131 , 2021 ; 01420615 (ISSN) Farzin, H ; Monadi, M ; Fotuhi Firuzabad, M ; Savaghebi, M ; Sharif University of Technology
    Elsevier Ltd  2021
    Abstract
    The number of harmonic-producing sources is rapidly growing in the power grid due to the increased penetration of power electronic-interfaced resources (such as wind turbines, photovoltaic systems, and energy storage units) and proliferation of nonlinear loads. Many researchers have investigated the effects of non-sinusoidal waveforms on the performance of different types of protective relays, and have reported some harmonic-related malfunctions. This paper presents a detailed Markov model that captures different impacts of harmonics on the reliability of overcurrent relays. In addition to addressing relevant considerations of the previous reliability models, this model accounts for new... 

    Low complexity resource allocation in the relay channels with energy harvesting transmitters

    , Article Ad Hoc Networks ; Volume 77 , 2018 , Pages 108-118 ; 15708705 (ISSN) Mohassel Feghhi, M ; Abbasfar, A ; Mirmohseni, M ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    Energy Harvesting (EH) is a novel technique to prolong the lifetime of the wireless Ad-hoc and sensor networks with replenishable nodes. In this sense, it has emerged as a promising technique for Green Communications. On the other hand, cooperative communication with the help of relay nodes improves the performance of wireless communication networks. In this paper, we investigate the cooperation in EH nodes. We consider the optimal power and rate allocation in the full-duplex Gaussian relay channel in which source and relay can harvest energy from their environments. In our model, the energy arrivals at the source and the relay are general stochastic processes with known EH times and amounts... 

    New considerations in modern protection system quantitative reliability assessment

    , Article IEEE Transactions on Power Delivery ; Vol. 25, issue. 4 , 2010 , p. 2213-2222 ; ISSN: 8858977 Etemadi, A. H ; Fotuhi-Firuzabad, M ; Sharif University of Technology
    Abstract
    Protective relay technologies have evolved from single-function electromechanical and static relays to modern multifunction digital relays over the past few years. Protection systems play a vital role in maintaining a desirable level of reliability in power systems. Thus, their own reliability should be evaluated and any cause of their malfunction should be fully comprehended. In this paper, a new reliability model is proposed that associates protection system failures to four main causes: 1) relay hardware, 2) relay software, 3) ancillary equipment, and 4) human error. In addition, this model can take other aspects of the protection system into consideration, such as human error during... 

    Random coding bound for E-capacity region of the relay channel with confidential messages

    , Article IWCIT 2014 - Iran Workshop on Communication and Information Theory ; May , 2014 ; 978-1-4799-4878-9 Afshar, N ; Akhbari, B ; Aref, M. R ; Sharif University of Technology
    Abstract
    We study a relay channel with confidential messages (RCC), which involves a sender, a receiver and a relay. In the RCC, a common information must be transmitted to both a receiver and a relay and also a private information to the intended receiver, while keeping the relay as ignorant of it as possible. The level of ignorance of the relay rather than the private message is measured by the equivocation rate. We consider two error probability exponents (reliabilities) E1, E2 of exponentially decrease of error probability of the receiver decoder and the relay decoder, respectively. For E = (E1, E2), the E-capacity region is the set of all E-achievable rates of codes with given reliability E. We... 

    Finite-SNR diversity-multiplexing tradeoff in multi-relay channels

    , Article 2013 Iran Workshop on Communication and Information Theory ; 2013 ; 9781467350235 (ISBN) Haddadpour, F ; Gholami, E ; Rastegar, S. H ; Behroozi, H ; Sharif University of Technology
    2013
    Abstract
    In this paper, we investigate the diversity-multiplexing tradeoff (DMT) for multi-relay channels in finite-SNR regime. In our analysis, we consider the decode and forward (DF) relaying strategy and a line of sight path from source to destination. First, we determine the outage probability in a multi-relay scenario and obtain its exact analytical expressions. Then, the outage probability of a multi-relay channel with relay selection is calculated and provided as a closed-form expression. Based on these results, we determine the DMT in finite-SNR regime. Finally, using simulation results, we show that our analysis has accurate results which coincides with that of obtained from Monte-Carlo... 

    Digital distance protection of transmission lines in the presence of SSSC

    , Article International Journal of Electrical Power and Energy Systems ; Volume 43, Issue 1 , December , 2012 , Pages 712-719 ; 01420615 (ISSN) Ghorbani, A ; Mozafari, B ; Ranjbar, A. M ; Sharif University of Technology
    2012
    Abstract
    In this paper the impact of Static Synchronous Series Compensator (SSSC) on the impedance calculated by distance relay is investigated. Analytical results are presented and verified by detailed simulations. Six different phase to phase and phase to ground measuring units of the distance relay are simulated to resemble the behavior of the relay. It is shown in this paper that zero sequence of the injected voltage by 48 pulse SSSC converter has the most impact on the apparent impedance seen by the phase to ground fault measuring unit and cause under reaching of distance relay. It can be concluded from the results that SSSC located in the middle of the transmission line cause to divide trip... 

    Lattice-coded cooperation protocol for the half-duplex Gaussian two-way relay channel

    , Article Eurasip Journal on Wireless Communications and Networking ; Volume 2015, Issue 1 , 2015 , Pages 1-18 ; 16871472 (ISSN) Ghasemi Goojani, S ; Behroozi, H ; Sharif University of Technology
    Abstract
    This paper studies the Gaussian two-way relay channel (GTWRC), where two nodes exchange their messages with the help of a half-duplex relay. We investigate a cooperative transmission protocol, consisting of four phases: multiple access (MA) phase, broadcast (BC) phase, and two cooperative phases. For this setup, we propose a new transmission scheme based on superposition coding for nested lattice codes, random coding, and jointly typical decoding. This scheme divides the message of each node into two parts, referred to as satellite codeword and cloud center. Depending on the phase type, the encoder sends a linear combination of satellite codewords or cloud centers. For comparison, a rate... 

    New considerations in modern protection system quantitative reliability assessment

    , Article IEEE Transactions on Power Delivery ; Volume 25, Issue 4 , September , 2010 , Pages 2213-2222 ; 08858977 (ISSN) Etemadi, A. H ; Fotuhi Firuzabad, M ; Sharif University of Technology
    2010
    Abstract
    Protective relay technologies have evolved from single-function electromechanical and static relays to modern multifunction digital relays over the past few years. Protection systems play a vital role in maintaining a desirable level of reliability in power systems. Thus, their own reliability should be evaluated and any cause of their malfunction should be fully comprehended. In this paper, a new reliability model is proposed that associates protection system failures to four main causes: 1) relay hardware, 2) relay software, 3) ancillary equipment, and 4) human error. In addition, this model can take other aspects of the protection system into consideration, such as human error during... 

    A new achievable rate region for the gaussian two-way relay channel via hybrid broadcast protocol

    , Article IEEE Communications Letters ; Vol. 18, issue. 11 , 2014 , pp. 1883-1886 ; ISSN: 10897798 Ghasemi Goojani, S ; Behroozi, H ; Sharif University of Technology
    Abstract
    In this letter, we study the Gaussian two-way relay channel (GTWRC) with a direct link in which two nodes want to exchange information with each other with the help of a relay node in the presence of a direct link between two nodes. Specially, we focus on a protocol with four phases, which is called the hybrid broadcast (HBC) protocol. In the HBC protocol, sequential transmissions from both users are followed by a transmission from the relay. Using nested lattice codes, we obtain a new achievable rate region for this protocol. In fact, utilizing a four-stage lattice partition chain, we introduce an intermediate lattice in our lattice-based coding scheme, and by using it, we split the...