Loading...
Search for: fault-detection-systems
0.012 seconds

    FPGA-based fault tolerant scheme with reduced extra-sensor number for WECS with DFIG

    , Article Proceedings - ISIE 2011: 2011 IEEE International Symposium on Industrial Electronics, 27 June 2011 through 30 June 2011 ; 2011 , Pages 1595-1601 ; 9781424493128 (ISBN) Shahbazi, M ; Gaillard, A ; Poure, P ; Zolghadri, M. R ; Sharif University of Technology
    2011
    Abstract
    Fast fault detection and converter reconfiguration is necessary for fault tolerant doubly fed induction generator (DFIG) in wind energy conversion systems (WECS) to prevent further damage and to make possible the continuity of service. Extra sensors are needed in order to detect the faults rapidly. In this paper, a very fast FPGA-based fault detection scheme is presented that minimizes the number of additional voltage sensors. A fault tolerant converter topology for this application is studied. Control and fault detection system are implemented on a single FPGA and Hardware in the Loop experiments are performed to evaluate the proposed detection scheme, the digital controller and the fault... 

    Fast detection of open-switch faults with reduced sensor count for a fault-tolerant three-phase converter

    , Article 2011 2nd Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2011 ; 2011 , Pages 546-550 ; 9781612844213 (ISBN) Shahbazi, M ; Zolghadri, M ; Poure, P ; Saadate, S ; Sharif University of Technology
    Abstract
    Fast fault detection and reconfiguration is necessary in power electronic converters in lots of applications to prevent further damage and to make possible the continuity of service. In this paper a very fast fault detection scheme is presented that minimizes the use of voltage sensors. A fault tolerant topology is studied. Control and fault detection system are implemented on a single FPGA and hardware in the loop experiments are performed to evaluate the detection scheme, the digital controller and the structure  

    A series stacked IGBT switch to be used as a fault current limiter in HV high-power supplies

    , Article IEEE Journal of Emerging and Selected Topics in Power Electronics ; Volume 9, Issue 5 , 2021 , Pages 6300-6314 ; 21686777 (ISSN) Mohsenzade, S ; Zarghani, M ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2021
    Abstract
    The safe operating condition for the vacuum tubes is very important and critical since they are very expensive and delicate. Providing limited short circuit energy for the vacuum tube and fast transferring from the short circuit to the nominal operation state are absolutely necessary. Extant protection strategies threat the availability of the vacuum tubes. In addition, they cannot completely protect the tube due to the delay of the fault detection system. This article proposes a high voltage (HV) short circuit fault current limiter which can limit the short circuit energy of the system inherently. The proposed structure activates automatically when the current exceeds the predetermined...