Loading...
Search for: fault-location
0.008 seconds
Total 28 records

    Limiting fault currents in wind power plants using superconductive shielded core reactors

    , Article IEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES, Pittsburgh, PA, 20 July 2008 through 24 July 2008 ; 2008 ; 9781424419067 (ISBN) Behzadirafi, S ; Salehfar, H ; Varahram, H ; Sharif University of Technology
    2008
    Abstract
    In this paper we investigate the effects of superconducting shielded core reactor (SSCR) on the operation of induction generators. Large number of induction generators used in wind power plants generally increase the short circuit current level of the system. The reason is that they provide parallel reduced-impedance paths for the fault currents. Taking advantage of SSCR in wind power plants allows for using these generating units in large numbers with no concerns about the system fault current increments. The study is performed on a test system using the conventional model of an induction generator and a new effective model for SSCR based on its shielding behavior. Mathematical equations... 

    A novel method for fault location of transmission lines by wide-area voltage measurements considering measurement errors

    , Article IEEE Transactions on Smart Grid ; Volume 6, Issue 2 , 2015 , Pages 874-884 ; 19493053 (ISSN) Dobakhshari, A. S ; Ranjbar, A. M ; Sharif University of Technology
    Abstract
    Smart transmission grids are intended to utilize various measurements for enhanced operation. In particular, synchronized phasor measurements have found many applications in this context. This paper presents a linear weighted least-squares (WLS) method for fault location estimation of transmission lines by synchronized voltage measurements. The measurements may be taken from the faulted line terminals or buses far from the faulted line. The circuit equations of the network are used to find the transfer function between the fault location and each voltage measurement. Next, two auxiliary variables are defined to transform the nonlinear fault location estimation problem into a linear WLS... 

    Optimal placement of sectionalizing switch considering switch malfunction probability

    , Article IEEE Transactions on Smart Grid ; 2017 ; 19493053 (ISSN) Farajollahi, M ; Fotuhi Firuzabad, M ; Safdarian, A ; Sharif University of Technology
    Abstract
    Sectionalizing switches (SSs) are often presumed to function fully reliable. However, SSs are exposed to have some malfunctions, whereby undermining their ability to improve service reliability. This study presents a model to integrate SS malfunction probability into SS placement problem. The model aims to minimize the total SSs costs as well as customers interruption cost. The proposed model is formulated in mixed integer programing (MIP), which can be easily solved via several available solvers and gain global optimal solution. The proposed model indicates the extent to which the placement problem is affected by uncertainty associated with SSs functionality, and how not considering SSs... 

    Deployment of fault indicator in distribution networks: a MIP-based approach

    , Article IEEE Transactions on Smart Grid ; Volume 9, Issue 3 , May , 2018 , Pages 2259-2267 ; 19493053 (ISSN) Farajollahi, M ; Fotuhi Firuzabad, M ; Safdarian, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    Fault indicator (FI) plays a crucial rule in enhancing service reliability in distribution systems. This device brings substantial benefits for fault management procedure by speeding up fault location procedure. This paper intends to develop a new optimization model to optimally deploy FI in distribution systems. The proposed model aims to consider a tradeoff between the total customer interruption cost and FI relevant costs, including capital investment, installation, and maintenance costs. As the main contribution of this paper, the problem is formulated in mixed integer programing, which guarantees global optimum solution achieved in an effective runtime. Moreover, the model takes... 

    Simultaneous placement of fault indicator and sectionalizing switch in distribution networks

    , Article IEEE Transactions on Smart Grid ; 2018 ; 19493053 (ISSN) Farajollahi, M ; Fotuhi Firuzabad, M ; Safdarian, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    Automation systems provide substantial improvement in service reliability through speeding up fault management procedure. However, this is at expense of high investments whose justification needs thorough cost/worth analyses. This paper introduces a mathematical model to optimally place automation system devices within distribution networks. The model establishes a trade-off between service reliability improvements and the relevant costs. Among different automation system devices, fault indicators and remote controlled switches are considered here. Also, the impact of manual switches is regarded since their number and location significantly affect the solution of the placement problem. The... 

    Optimal placement of sectionalizing switch considering switch malfunction probability

    , Article IEEE Transactions on Smart Grid ; Volume 10, Issue 1 , 2019 , Pages 403-413 ; 19493053 (ISSN) Farajollahi, M ; Fotuhi Firuzabad, M ; Safdarian, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Sectionalizing switches (SSs) are often presumed to function fully reliable. However, SSs are exposed to have some malfunctions, whereby undermining their ability to improve service reliability. This paper presents a model to integrate SS malfunction probability into SS placement problem. The model aims to minimize the total SSs costs as well as customers interruption cost. The proposed model is formulated in mixed integer programing, which can be easily solved via several available solvers and gain global optimal solution. The proposed model indicates the extent to which the placement problem is affected by uncertainty associated with SSs functionality, and how not considering SSs... 

    Optimal placement of sectionalizing switch considering switch malfunction probability

    , Article IEEE Transactions on Smart Grid ; Volume 10, Issue 1 , 2019 , Pages 403-413 ; 19493053 (ISSN) Farajollahi, M ; Fotuhi Firuzabad, M ; Safdarian, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Sectionalizing switches (SSs) are often presumed to function fully reliable. However, SSs are exposed to have some malfunctions, whereby undermining their ability to improve service reliability. This paper presents a model to integrate SS malfunction probability into SS placement problem. The model aims to minimize the total SSs costs as well as customers interruption cost. The proposed model is formulated in mixed integer programing, which can be easily solved via several available solvers and gain global optimal solution. The proposed model indicates the extent to which the placement problem is affected by uncertainty associated with SSs functionality, and how not considering SSs... 

    Detecting the location of short-circuit faults in active distribution network using pmu-based state estimation

    , Article IEEE Transactions on Smart Grid ; Volume 11, Issue 2 , 2020 , Pages 1396-1406 Gholami, M ; Abbaspour, A ; Moeini Aghtaie, M ; Fotuhi Firuzabad, M ; Lehtonen, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    With the rapid advancement of phasor measurement units (PMUs) technology, system operators in different level of power systems have access to new and abundant measurements. Taking into account these measurements in active distribution systems (ADNs), a new algorithm for short-circuit fault detection and identification based on state estimation (SE) is introduced in this paper. In this regard, as the first step, traditional SE process is revised to be compatible with fault conditions. Then, a fault location algorithm (FLA) based on the revised SE (RDSSE) is presented which attends to detect the location of fault after diagnosing faulted zone. For this purpose, current and voltage... 

    Secure steganography using Gabor filter and neural networks

    , Article Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics) ; Volume 4920 LNCS , 2008 , Pages 33-49 ; 03029743 (ISSN); 3540690166 (ISBN); 9783540690160 (ISBN) Jamzad, M ; Zahedi Kermani, Z ; Sharif University of Technology
    2008
    Abstract
    The main concern of steganography (image hiding) methods is to embed a secret image into a host image in such a way that it causes minimum distortion to the host; to make it possible to extract a version of secret image from the host in such a way that the extracted version of secret image be as similar as possible to its original version (this should be possible even after usual attacks on the host image), and to provide ways of embedding secret images with larger size into a given host image. In this paper we propose a method that covers all above mentioned concerns by suggesting the idea of finding from an image data base, the most suitable host for a given secret image. In our method,... 

    A novel GA-based High-Level Synthesis technique to enhance RT-level concurrent testing

    , Article 14th IEEE International On-Line Testing Symposium, IOLTS 2008, Rhodes, 7 July 2008 through 9 July 2008 ; 2008 , Pages 173-174 ; 9780769532646 (ISBN) Karimi, N ; Aminzadeh, S ; Safari, S ; Navabi, Z ; Sharif University of Technology
    2008
    Abstract
    This paper presents an efficient High-Level Synthesis (HLS) approach to improve RT-Level concurrent testing. The proposed method used for both fault detection and fault location. At first the available resources are used in their dead intervals to test active resources for fault detection, and then some changes are applied to the RT-Level controller to locate the faults. The fault detection step is based on a genetic algorithm (GA) search technique. This genetic algorithm is applied to the design after high level synthesis process to explore the test map. The proposed method has been evaluated based on dependability enhancement and area/latency overhead imposed to different benchmarks after... 

    Fault analysis on AC railway supply system

    , Article 6th Annual International Power Electronics, Drive Systems, and Technologies Conference, PEDSTC 2015, 3 February 2015 through 4 February 2015 ; February , 2015 , Pages 567-572 ; 9781479976539 (ISBN) Noroozi, N ; Mokhtari, H ; Zolghadri, M. R ; Khodabandeh, M ; Abazai, A ; Seyyedi Khakshani, R ; Mazaheri, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    A short circuit fault in an AC railway supply system could have undesired consequences; including high-amplitude current flow in the power path, the rail potential rise in the fault vicinity. This paper studies the problem of the rail voltage rise in Tehran-Karaj railway system by the use of a steady state circuit model for the AC autotransformer during a phase-to-ground fault. By using this model, all the currents and voltages of the system can be easily calculated for all possible short circuit fault locations. With the help of the derived analytical model, one can also predict the possible fault locations which may cause the protection system to operate. The estimation of the system... 

    Reliability enhancement in switching substations using fault current limiters

    , Article 2006 9th International Conference on Probabilistic Methods Applied to Power Systems, PMAPS, Stockholm, 11 June 2006 through 15 June 2006 ; 2006 ; 9171783520 (ISBN); 9789171783523 (ISBN) Rafi, S. B ; Fotuhi Firuzabad, M ; Sidhu, T. S ; Sharif University of Technology
    2006
    Abstract
    Power system equipments are normally designed for a specific system and load situation. This situation could change significantly as a result of the system expansion or aging. Among the system equipments, circuit breakers are more sensitive to the system expansion and they must be able to isolate the faulty components if a fault occurs. As the system load increases in the future, the power network must be expanded. In this situation, either the switching equipments must be replaced in order to be able to respond to the new fault current or the fault current must be limited to the interrupting capability of the existing circuit breakers. Application of Fault current Limiters (FCL) serves as a... 

    Accurate unbalanced fault location method for multi-ended multi-tapped structures

    , Article International Review of Electrical Engineering ; Volume 8, Issue 2 , 2013 , Pages 839-848 ; 18276660 (ISSN) Rezaei Jegarluei, M ; Moaddabi, N ; Gharehpetian, G. B ; Mohammadalizadeh Shabestary, M ; Sharif University of Technology
    2013
    Abstract
    The accurate fault location is an important criterion for protection system. Accurate and fast fault location decreases the outage time, consumers dissatisfaction and operation cost. Different methods have been proposed to determine the fault location. The impedance-based methods are usually used to protect power systems. The accuracy of these methods depends on system parameters and the structure of power systems. Also, these methods require an iterative process, the phase alignment and a high volume of data. Another algorithm has been newly presented based on negative sequence parameters, which is not iterative and the amount of data communicated between relays is small. Besides, this... 

    A new algorithm for fault location on transmission lines by optimal PMU placement

    , Article International Transactions on Electrical Energy Systems ; Volume 25, Issue 10 , 2015 , Pages 2071-2086 ; 20507038 (ISSN) Rezaei Jegarluei, M ; Salehi Dobakhshari, A ; Ranjbar, A. M ; Tayebi, A ; Sharif University of Technology
    John Wiley and Sons Ltd  2015
    Abstract
    In this paper, the problem of placing a minimum number of phasor measurement units (PMUs) in a transmission system is considered so that faults on all lines of the network can be diagnosed and located irrespective of their locations. For this purpose, a PMU placement algorithm is applied to calculate the required data for impedance-based fault location of any fault line in the network, achieving the full potential of the circuit laws throughout the system. Another algorithm is then proposed to compute the voltage and current values of the fault line for fault-location purposes. Moreover, as many networks are already equipped with PMUs, the proposed algorithm makes it possible to locate... 

    Accurate fault location algorithm for series compensated transmission lines

    , Article IEEE Transactions on Power Delivery, Piscataway, NJ, United States ; Volume 15, Issue 3 , 2000 , Pages 1027-1033 ; 08858977 (ISSN) Sadeh, J ; Hadjsaid, N ; Ranjbar, A. M ; Feuillet, R ; Sharif University of Technology
    IEEE  2000
    Abstract
    In this paper, an accurate fault location algorithm for series compensated power transmission lines is presented. Distributed time domain model is used for modeling of the transmission lines. The algorithm makes use of two subroutines for estimation of the fault distance - one for faults behind the series capacitors and another one for faults in front of the series capacitors. Then a special procedure to select the correct solution is utilized. Samples of voltages and currents at both ends of the line are taken synchronously and used to calculate the location of the fault. The proposed algorithm is independent of fault resistance and does not require any knowledge of source impedance. The... 

    Accurate fault location algorithm for power transmission lines

    , Article European Transactions on Electrical Power ; Volume 10, Issue 5 , 2000 , Pages 313-318 ; 1430144X (ISSN) Sadeh, J ; Ranjbar, A. M ; Hadjsaid, N ; Feuillet, R ; Sharif University of Technology
    John Wiley and Sons Ltd  2000
    Abstract
    In this paper we propose a new fault location algorithm for power transmission lines based on one terminal voltage and current data. A distributed time domain model of the line is used as a basis for algorithm development. The suggested technique only takes advantage of post-fault voltage and current samples taken at one end of the line and does not require filtering of DC offset and high-frequency components of the recorded signals, which are present during transient conditions. Another advantage of the proposed method is the application of a very narrow window of data i. e. less than 1/4 of a cycle. The paper also proposes two different algorithms for lossless and lossy line models.... 

    Accurate fault location algorithm for series compensated transmission lines

    , Article IEEE Power Engineering Society Winter Meeting, 2000, 23 January 2000 through 27 January 2000 ; Volume 4 , 2000 , Pages 2527-2532 ; 0780359356 (ISBN); 9780780359352 (ISBN) Sadeh, J ; Ranjbar, A. M ; Hadsaid, N ; Feuillet, R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2000
    Abstract
    In this paper, an accurate fault location algorithm for series compensated power transmission lines is presented. A distributed time domain model is used for modeling of the transmission lines. The algorithm makes use of two subroutines for estimation of the fault distance-one for faults behind the series capacitors and another one for faults in front of the series capacitors. Then a special procedure to select the correct solution is utilized. Samples of voltages and currents at both ends of the line are taken synchronously and used to calculate the location of the fault. The proposed algorithm is independent of fault resistance and does not require any knowledge of source impedance. The... 

    A closed-form solution for transmission line fault location using local measurements at a remote substation

    , Article Electric Power Systems Research ; Volume 111 , June , 2014 , Pages 115-122 ; ISSN: 03787796 Salehi Dobakhshari, A ; Ranjbar, A. M ; Sharif University of Technology
    Abstract
    This paper presents a novel approach for fault location of overhead transmission lines by voltage and current measurements in a remote substation. The method is applicable when not all of the transmission lines in an area are equipped with fault-locators, although there may be a critical substation (CS) in the area equipped with a digital fault recorder (DFR). In the proposed method, the circuit equations of the network are used to find the transfer function between the fault location and each voltage and current measurement in the CS. Next, two auxiliary variables are defined to transform the nonlinear fault location estimation problem into a linear least squares problem. A closed-form... 

    Robust fault location of transmission lines by synchronised and unsynchronised wide-area current measurements

    , Article IET Generation, Transmission and Distribution ; Volume 8, Issue 9 , 1 September , 2014 , Pages 1561-1571 ; ISSN: 17518687 Salehi-Dobakhshari, A ; Ranjbar, A. M ; Sharif University of Technology
    Abstract
    This study presents a novel method for fault location of transmission lines by multiple fault current measurements. In contrast to conventional methods, it is proposed to utilise several current measurements, which may be far from the faulted line. The circuit equations of the network are used to express each fault current as a function of fault location. Fault location is then estimated using a least-squares estimation technique. To achieve a robust estimation of fault location, statistical hypotheses-testing is employed for identifying erroneous measurements. The method is applicable to both synchronised and unsynchronised measurements. Moreover, fault location can be estimated regardless... 

    A new algorithm for fault location on transmission lines

    , Article 2009 IEEE Power and Energy Society General Meeting, PES '09, Calgary, AB, 26 July 2009 through 30 July 2009 ; 2009 ; 9781424442416 (ISBN) Shiroei, M ; Daniar, S ; Akhbari, M ; Sharif University of Technology
    IEEE  2009
    Abstract
    In this paper, a new algorithm for fault detection/location on transmission line based on linear state estimation is presented. The proposed technique uses phasor measurements from PMU's. Fault location and voltage of fault point are added as the new state variables in a linear state estimator based on PMU data. In addition, by using the ability of bad data identification in the state estimation, a new scheme for fault location and identification of faulted transmission line is proposed. For test and validation of the proposed algorithm, simulation results on a six bus test case are presented. ©2009 IEEE