    Six-leg AC-AC fault tolerant converter with reduced extra-sensor number

    , Article International Review of Electrical Engineering ; Volume 6, Issue 1 , 2011 , Pages 132-138 ; 18276660 (ISSN) Shahbazi, M ; Poure, P ; Zolghadri, M. R ; Saadate, S ; Sharif University of Technology
    Abstract
    In order to prevent further damage and to provide the continuity of service of six-leg converter in case of open-switch fault, it is mandatory to perform fast fault detection and converter reconfiguration schemes. Extra sensors are needed to detect the faults rapidly. In this paper, a very fast FPGA-based fault detection scheme is presented that minimizes the number of additional voltage sensors. A six-leg fault tolerant converter topology without redundancy and with bidirectional power flow is studied. First simulations are carried out to evaluate the proposed fault detection principle and the fault tolerant converter topology. The fully digital control and the fault detection are...