Loading...
Search for: high-sensitivity
0.006 seconds
Total 33 records

    A New Method for Measuring very Low Variation in Physical Parameters based on the Sensitivity to Conditions of Chaotic Systems

    , M.Sc. Thesis Sharif University of Technology Seddighi Renani, Jamal (Author) ; Zohoor, Hasan (Supervisor)
    Abstract
    Since the beginning of human civilization, improving the methods of measuring and identifying changes in order to improve the level of comfort and safety of human civilization is inevitable. The intrinsic property of high sensitivity to system conditions in chaos phenomena has led some researchers to use this feature for purposes of identifying and measuring changes. The most important bugs of previous researches in this area are the complexity, lack of coherence and dependence on the nominal parameters. By analyzing the effect of the type and magnitude of the initial deviation in a system parameter on all the characteristics of the Duffing system response in the chaotic regime, was observed... 

    The decoration of TiO2/reduced graphene oxide by Pd and Pt nanoparticles for hydrogen gas sensing

    , Article International Journal of Hydrogen Energy ; Volume 37, Issue 20 , 2012 , Pages 15423-15432 ; 03603199 (ISSN) Esfandiar, A ; Ghasemi, S ; Irajizad, A ; Akhavan, O ; Gholami, M. R ; Sharif University of Technology
    Elsevier  2012
    Abstract
    Reduced graphene oxide (RGO) was used to improve the hydrogen sensing properties of Pd and Pt-decorated TiO2 nanoparticles by facile production routes. The TiO2 nanoparticles were synthesized by sol-gel method and coupled on GO sheets via a photoreduction process. The Pd or Pt nanoparticles were decorated on the TiO2/RGO hybrid structures by chemical reduction. X-ray photoelectron spectroscopy demonstrated that GO reduction is done by the TiO2 nanoparticles and Ti-C bonds are formed between the TiO2 and the RGO sheets as well. Gas sensing was studied with different concentrations of hydrogen ranging from 100 to 10,000 ppm at various temperatures. High sensitivity (92%) and fast response time... 

    In situ solid-phase microextraction and post on-fiber derivatization combined with gas chromatography-mass spectrometry for determination of phenol in occupational air

    , Article Analytica Chimica Acta ; Volume 742 , 2012 , Pages 17-21 ; 00032670 (ISSN) Es haghi, A ; Baghernejad, M ; Bagheri, H ; Sharif University of Technology
    Elsevier  2012
    Abstract
    A method based on solid-phase microextraction (SPME) followed by on-fiber derivatization and gas chromatography-mass spectrometry detection (GC-MS) for determination of phenol in air was developed. Three different types of SPME fibers, polar and non-polar poly(dimethylsiloxane) (PDMS) and polyethylene glycol (PEG) were synthesized using sol-gel technology and their feasibility to the sampling of phenol were investigated. Different derivatization reagents for post on-fiber derivatization of phenol were studied. Important parameters influencing the extraction and derivatization process such as type of fiber coating, type and volume of derivatizing reagent, derivatization time and temperature,... 

    Fabrication of a modified electrode based on Fe3 O4 NPs/MWCNT nanocomposite: Application to simultaneous determination of guanine and adenine in DNA

    , Article Bioelectrochemistry ; Volume 86 , 2012 , Pages 78-86 ; 15675394 (ISSN) Shahrokhian, S ; Rastgar, S ; Amini, M. K ; Adeli, M ; Sharif University of Technology
    Abstract
    Multi-walled carbon nanotubes decorated with Fe 3O 4 nanoparticles (Fe 3O 4NPs/MWCNT) were prepared and used to construct a novel biosensor for the simultaneous detection of adenine and guanine. The direct electro-oxidation of adenine and guanine on the modified electrode were investigated by linear sweep voltammetry. The results indicate a remarkable increase in the oxidation peak currents together with negative shift in the oxidation peak potentials for both adenine and guanine, in comparison to the bare glassy carbon electrode (GCE). The surface morphology and nature of the composite film deposited on GCE were characterized by transmission electron microscopy, atomic force microscopy,... 

    Electrodeposition of long gold nanotubes in polycarbonate templates as highly sensitive 3D nanoelectrode ensembles

    , Article Electrochimica Acta ; Volume 75 , 2012 , Pages 157-163 ; 00134686 (ISSN) Bahari Mollamahalle, Y ; Ghorbani, M ; Dolati, A ; Sharif University of Technology
    Elsevier  2012
    Abstract
    Electrodeposition of long and well-defined gold nanotubes in polycarbonate (PC) templates is still a major concern due to pore blockage problems. In the present study, we introduce a novel method for electrodeposition of long gold nanotubes within the pores of PC templates for the first time. In order to deposit gold atoms onto the pore walls preferentially, pore walls were functionalized with a coupling agent. Short and thin Ni nanotubes were then electrodeposited at the bottom of the pores. Gold nanotubes were subsequently electrodeposited at constant potentials and low solution concentrations. The morphology of nanotubes was characterized by electron microscopy and their formation... 

    Fabrication of sensitive glutamate biosensor based on vertically aligned CNT nanoelectrode array and investigating the effect of CNTs density on the electrode performance

    , Article Analytical Chemistry ; Volume 84, Issue 14 , June , 2012 , Pages 5932-5938 ; 00032700 (ISSN) Gholizadeh, A ; Shahrokhian, S ; Iraji Zad, A ; Mohajerzadeh, S ; Vosoughi, M ; Darbari, S ; Koohsorkhi, J ; Mehran, M ; Sharif University of Technology
    2012
    Abstract
    In this report, the fabrication of vertically aligned carbon nanotube nanoelectrode array (VACNT-NEA) by photolithography method is presented. Electrochemical impedance spectroscopy as well as cyclic voltammetry was performed to characterize the arrays with respect to different diffusion regimes. The fabricated array illustrated sigmoidal cyclic voltammogram with steady state current dominated by radial diffusion. The fabricated VACNT-NEA and high density VACNTs were employed as electrochemical glutamate biosensors. Glutamate dehydrogenase is covalently attached to the tip of CNTs. The voltammetric biosensor, based on high density VACNTs, exhibits a sensitivity of 0.976 mA mM-1 cm-2 in the... 

    Property change during nanosecond pulse laser annealing of amorphous NiTi thin film

    , Article Bulletin of Materials Science ; Volume 35, Issue 3 , 2012 , Pages 357-364 ; 02504707 (ISSN) Sadrnezhaad, S. K ; Yasavol, N ; Ganjali, M ; Sanjabi, S ; Sharif University of Technology
    2012
    Abstract
    Nanosecond lasers of different intensities were pulsed into sputter-deposited amorphous thin films of near equiatomic Ni/Ti composition to produce partially crystallized highly sensitive R-phase spots surrounded by amorphous regions. Scanning electron microscopy having secondary and back-scattered electrons, field emission scanning electron microscopy, optical microscopy and X-ray diffraction patterns were used to characterize the laser treated spots. Effect of nanosecond pulse lasering on microstructure, morphology, thermal diffusion and inclusion formation was investigated. Increasing beam intensity and laser pulse-number promoted amorphous to R-phase transition. Lowering duration of the... 

    Amperometric sulfide detection using Coprinus cinereus peroxidase immobilized on screen printed electrode in an enzyme inhibition based biosensor

    , Article Biosensors and Bioelectronics ; Volume 35, Issue 1 , 2012 , Pages 297-301 ; 09565663 (ISSN) Savizi, I. S. P ; Kariminia, H. R ; Ghadiri, M ; Roosta Azad, R ; Sharif University of Technology
    2012
    Abstract
    In the present work, an amperometric inhibition biosensor for the determination of sulfide has been fabricated by immobilizing Coprinus cinereus peroxidase (CIP) on the surface of screen printed electrode (SPE). Chitosan/acrylamide was applied for immobilization of peroxidase on the working electrode. The amperometric measurement was performed at an applied potential of -150. mV versus Ag/AgCl with a scan rate of 100. mV in the presence of hydroquinone as electron mediator and 0.1. M phosphate buffer solution of pH 6.5. The variables influencing the performance of sensor including the amount of substrate, mediator concentration and electrolyte pH were optimized. The determination of sulfide... 

    Highly sensitive voltammetric determination of lamotrigine at highly oriented pyrolytic graphite electrode

    , Article Bioelectrochemistry ; Volume 84 , 2012 , Pages 38-43 ; 15675394 (ISSN) Saberi, R. S ; Shahrokhian, S ; Sharif University of Technology
    2012
    Abstract
    The electrochemical behavior of lamotrigine (LMT) at the pyrolytic graphite electrode (PGE) is investigated in detail by the means of cyclic voltammetry. During the electrochemical reduction of LMT, an irreversible cathodic peak appeared. Cyclic voltammetric studies indicated that the reduction process has an irreversible and adsorption-like behavior. The observed reduction peak is attributed to a two-electron process referring to the reduction of azo group. The electrode showed an excellent electrochemical activity toward the electro-reduction of LMT, leading to a significant improvement in sensitivity as compared to the glassy carbon electrode. The results of electrochemical impedance... 

    Optimization of a vanillin assay for determination of anthocyanins using D-optimal design

    , Article Analytical Methods ; Volume 4, Issue 3 , Feb , 2012 , Pages 824-829 ; 17599660 (ISSN) Khoshayand, M. R ; Roohi, T ; Moghaddam, G ; Khoshayand, F ; Shahbazikhah, P ; Oveisi, M. R ; Hajimahmoodi, M ; Sharif University of Technology
    Abstract
    The vanillin assay is a spectrophotometric method for anthocyanin determination that is simple, quick and inexpensive. The method is preferred because of its high sensitivity, specificity and simplicity; however, the results of this test are influenced by several factors. Hence, a D-optimal experimental design approach was investigated to simultaneously, without loss of information, optimize five factors that influence the vanillin assay: acid normality, vanillin concentration, temperature, time and acid type. Further optimization with a D-optimal design and response surface analysis (RSM) showed that a second-order polynomial model fit the experimental data appropriately. The optimum... 

    Mediator-less highly sensitive voltammetric detection of glutamate using glutamate dehydrogenase/vertically aligned CNTs grown on silicon substrate

    , Article Biosensors and Bioelectronics ; Volume 31, Issue 1 , 2012 , Pages 110-115 ; 09565663 (ISSN) Gholizadeh, A ; Shahrokhian, S ; Iraji zad, A ; Mohajerzadeh, S ; Vosoughi, M ; Darbari, S ; Sanaee, Z ; Sharif University of Technology
    Abstract
    A sensitive glutamate biosensor is prepared based on glutamate dehydrogenase/vertically aligned carbon nanotubes (GLDH, VACNTs). Vertically aligned carbon nanotubes were grown on a silicon substrate by direct current plasma enhanced chemical vapor deposition (DC-PECVD) method. The electrochemical behavior of the synthesized VACNTs was investigated by cyclic voltammetry and electrochemical impedance spectroscopic methods. Glutamate dehydrogenase covalently attached on tip of VACNTs. The electrochemical performance of the electrode for detection of glutamate was investigated by cyclic and differential pulse voltammetry. Differential pulse voltammetric determinations of glutamate are performed... 

    Corrosion detection in pipes by piezoelectric sensors using Artificial Neural Network

    , Article Advanced Materials Research, 4 November 2011 through 6 November 2011 ; Volume 403-408 , November , 2012 , Pages 748-752 ; 10226680 (ISSN) ; 9783037853122 (ISBN) Rafezi, H ; Rahmani, B ; Sharif University of Technology
    2012
    Abstract
    Defect detection in pipes is an essential task specially for sensitive applications such as oil and gas industry where special cares are required. Corrosion is a common defect in pipes which has attracted attention of researchers. In present work a non-destructive methodology for pipe corrosion monitoring is introduced. Polymer of Vinylidene Fluoride (PVDF) Piezoelectric is used as the sensor to measure strain variations affected by internal corrosion. High sensitivity and low cost of piezoelectric materials made them a good candidate for precise industrial applications. Different corrosion conditions (i.e. corrosion location along pipe and corrosion depth) are modeled and sensors voltages... 

    Catalytic activity of TiO 2 nanotubes modified with carbon and Pt nanoparticles for detection of dopamine

    , Article ECS Transactions ; Volume 35, Issue 35 , 2011 , Pages 53-62 ; 19385862 (ISSN) ; 9781607682950 (ISBN) Mahshid, S ; Mahshid, S. S ; Ghahremaninezhad, A ; Askari, M ; Dolati, A ; Yang, L ; Luo, Sh ; Cai, Q ; Sensor; Organic and Biological Electrochemistry ; Sharif University of Technology
    2011
    Abstract
    Catalytic activity of carbon/Pt nanoparticles modified TiO 2 nanotubes electrode was studied by using dopamine contained solutions. The TiO 2 nanotubes electrode was prepared using anodizing method in aqueous solution. The electrochemical pulse method was then applied for electrodeposition of Pt nanoparticles onto the TiO 2 nanotubes. Further modification was achieved by decomposition of polyethylene glycol in a tube furnace to have a carbon/Pt nanoparticles modified TiO 2 nanotubes electrode. The final modified electrode could successfully detect the electro-oxidation of dopamine in a ImM contained solution using cyclic voltametry method. Also, a high sensitivity towards the oxidation of... 

    Investigation of humidity effect on the air refractive index using an optical fiber design

    , Article Journal of Applied Sciences ; Volume 11, Issue 16 , 2011 , Pages 3022-3027 ; 18125654 (ISSN) Mehrabani, A ; Golnabi, H ; Sharif University of Technology
    2011
    Abstract
    In this study operation of an optical design based on the intensity modulation for the refractive index change has been described. The reported instrument measures the transmitted output power depending up on the medium refractive index in the light path of a fiber-to-fiber design. A liquid cell is located between the fibers in the light path and power variations for different cold and hot water levels in the cell are measured. By using a reference humidity meter the calibration curve representing the relative humidity (%RH) as a function of the transmitted output power is obtained. For the hot water with the final temperature of T = 32.7°C the output power range of 255.0 -313.OnW is... 

    Nonlinear vibration analysis of a micro beam exposed to an external flow

    , Article ASME 2011 International Mechanical Engineering Congress and Exposition, IMECE 2011 ; Volume 7, Issue PARTS A AND B , 2011 , Pages 643-646 ; 9780791854938 (ISBN) Mazaheri, H ; Hosseinzadeh, A ; Ahmadian, M. T ; Barari, A ; Sharif University of Technology
    2011
    Abstract
    In this paper, nonlinear vibration of a micro cantilever exposed to a constant velocity flow is studied. In order to obtain vibration frequency and time response of the micro beam the variational iteration method is used as a novel tool for solving nonlinear differential equations. Results of the analytical solution are compared with those obtained by Runge-Kutta method which shows very good agreement between them. Results confirm that frequency of vibration depends on the flow velocity. Also, the high sensitivity of the vibration frequency to the flow velocity means that it can be an effective indicator of velocity  

    Glassy carbon electrode modified with a bilayer of multi-walled carbon nanotube and polypyrrole doped with new coccine: Application to the sensitive electrochemical determination of Sumatriptan

    , Article Electrochimica Acta ; Volume 56, Issue 27 , November , 2011 , Pages 10032-10038 ; 00134686 (ISSN) Shahrokhian, S ; Kamalzadeh, Z ; Saberi, R. S ; Sharif University of Technology
    2011
    Abstract
    A promising electrochemical sensor was developed based on a layer by layer process by electro-polymerization of pyrrole in the presence of new coccine (NC) as dopant anion on the surface of the multi-walled carbon nanotubes (MWCNTs) pre-coated glassy carbon electrode (GCE). The modified electrode was used as a new and sensitive electrochemical sensor for voltammetric determination of sumatriptan (SUM). The electrochemical behavior of SUM was investigated on the surface of the modified electrode using linear sweep voltammetry (LSV). The results showed a remarkable increase (∼12 times) in the anodic peak current of SUM in comparison to the bare GCE. The effect of experimental variables such... 

    A novel photometric glucose biosensor based on decolorizing of silver nanoparticles

    , Article Sensors and Actuators, B: Chemical ; Volume 158, Issue 1 , November , 2011 , Pages 185-189 ; 09254005 (ISSN) Tashkhourian, J ; Hormozi Nezhad, M. R ; Khodaveisi, J ; Dashti, R ; Sharif University of Technology
    2011
    Abstract
    A novel glucose biosensor based on chromophore (silver nanoparticles) decolorizing for the photometric determination of glucose was developed. Silver nanoparticles are directly synthesized in the sol-gel matrix by a one-step method based on the reduction of the inorganic precursor AgNO3 and were used for the preparation, characterization and calibration of a highly sensitive and cost-effective localized surface plasmon resonance-based glucose biosensor. In the presence of glucose oxidase (GOx) and due to the enzyme-substrate (glucose) reaction, H2O2 was produced and silver nanoparticles in the sol-gel glass have the ability for the decomposition of hydrogen peroxide. Due to the degradation... 

    Multi sensing grasper for minimally invasive surgery

    , Article IEEE/ASME International Conference on Advanced Intelligent Mechatronics, AIM, 3 July 2011 through 7 July 2011, Budapest ; July , 2011 , Pages 344-349 ; 9781457708381 (ISBN) Fattahi, S. J ; Zabihollah, A ; Adldoost, H ; Sharif University of Technology
    2011
    Abstract
    In the present work, a multi sensing grasper has been developed for minimally invasive surgery with embedded ZnO piezoelectric and Fiber Bragg Grating sensors. In this model, a sensing patch equipped with three FBG sensors to sense the temperature in rage of 800 n.m and two separated FBG in range of 1550 m.m to detect the displacement in x and y directions. ZnO piezoelectric is highly sensitive to time and provides a good resistance to temperature. Therefore, this sensor is used for measuring the rate of strain and creep coefficient. A finite element approach based on the viscous material theory and plane displacement theory of anisotropic materials has been utilized to obtain the compliance... 

    Copper oxide nanoflakes as highly sensitive and fast response self-sterilizing biosensors

    , Article Journal of Materials Chemistry ; Volume 21, Issue 34 , Jul , 2011 , Pages 12935-12940 ; 09599428 (ISSN) Akhavan, O ; Ghaderi, E ; Sharif University of Technology
    2011
    Abstract
    Vertical copper oxide nanoflakes were synthesized on a Cu foil through oxidation in alkaline conditions. X-ray photoelectron spectroscopy showed that after exposing the nanoflakes to an Escherichia coli bacterial suspension, the outermost surface of the nanoflakes was chemically reduced through the glycolysis process of the bacteria. Current-voltage (I-V) characteristics of the nanoflakes (measured perpendicular to surface of the Cu foil by using conductive atomic force microscopy) indicated that electrical resistivity of the nanoflakes increased about one order of magnitude after exposure to the bacterial suspension. The nanoflakes reduced by the bacterial suspension could also be... 

    Carbon-Pt nanoparticles modified TiO 2 nanotubes for simultaneous detection of dopamine and uric acid

    , Article Journal of Nanoscience and Nanotechnology ; Volume 11, Issue 8 , 2011 , Pages 6668-6675 ; 15334880 (ISSN) Mahshid, S ; Luo, S ; Yang, L ; Mahshid, S. S ; Askari, M ; Dolati, A ; Cai, Q ; Sharif University of Technology
    Abstract
    The present work describes sensing application of modified TiO 2 nanotubes having carbon-Pt nanoparticles for simultaneous detection of dopamine and uric acid. The TiO 2 nanotubes electrode was prepared using anodizing method, followed by electrodeposition of Pt nanoparticles onto the tubes. Carbon was deposited by decomposition of polyethylene glycol in a tube furnace to improve the conductivity. The C-Pt-TiO 2 nanotubes modified electrode was characterized by cyclic voltam-metry and differential pulse voltammetry methods. The modified electrode displayed high sensitivity towards the oxidation of dopamine and uric acid in a phosphate buffer solution (pH 7.00). The electro-oxidation currents...