Loading...
Search for: in-buildings
0.011 seconds

    Nonlinear dynamics, bifurcation and performance analysis of an air-handling unit: Disturbance rejection via feedback linearization

    , Article Energy and Buildings ; Vol. 56 , 2013 , pp. 150-159 ; ISSN: 03787788 Moradi, H ; Saffar-Avval, M ; Alasty, A ; Sharif University of Technology
    Abstract
    Nowadays, dynamic analysis of air-conditioner units is essential to achieve satisfactory comfort conditions in buildings with low energy consumption and operation cost. In this paper, a nonlinear multi input-multi output model (MIMO) of an air-handling unit (AHU) is considered. In the presence of realistic harmonic disturbances, nonlinear dynamics of AHU is investigated. The effect of various thermodynamics and geometrical parameters on limit cycles behaviour of the indoor temperature is investigated. It is observed that the indoor space volume plays as the bifurcation parameter of the system. Decreasing the indoor space volume leads to the occurrence of secondary Hopf (Neimark) bifurcation... 

    Superpoly algebraic normal form monomial test on Trivium

    , Article IET Information Security ; Volume 7, Issue 3 , 2013 , Pages 230-238 ; 17518709 (ISSN) Vardasbi, A ; Salmasizadeh, M ; Mohajeri, J ; Sharif University of Technology
    2013
    Abstract
    Recently, AIDA/cube testers have been revealed to be useful in building distinguishers for several cryptography schemes. χ2 tests, on the other hand, are well known and extensively used for distinguishing purposes. In this study, the notion of multi-χ2 test and AIDA/cube testers are utilised to introduce the superpoly algebraic normal form monomial test through which the output of reduced round Trivium is distinguished from being random. The test successfully distinguishes the keystream of Trivium with 830 out of 1152 initialisation rounds with a complexity of 239 operations, which is the most effective distinguisher on reduced Trivium thus far. Applying algebraic IV differential attack... 

    Genetic algorithm-based pore network extraction from micro-computed tomography images

    , Article Chemical Engineering Science ; Volume 92 , 2013 , Pages 157-166 ; 00092509 (ISSN) Nejad Ebrahimi, A ; Jamshidi, S ; Iglauer, S ; Boozarjomehry, R ; Sharif University of Technology
    2013
    Abstract
    A genetic-based pore network extraction method from micro-computed tomography (micro-CT) images is proposed in this paper. Several variables such as the number, radius and location of pores, the coordination number, as well as the radius and length of the throats are used herein as the optimization parameters. Two approaches to generate the pore network structure are presented. Unlike previous algorithms, the presented approaches are directly based on minimizing the error between the extracted network and the real porous medium. This leads to the generation of more accurate results while reducing required computational memories. Two different objective functions are used in building the... 

    Nonlinear dynamics, bifurcation and performance analysis of an air-handling unit: Disturbance rejection via feedback linearization

    , Article Energy and Buildings ; Volume 56 , 2013 , Pages 150-159 ; 03787788 (ISSN) Moradi, H ; Saffar Avval, M ; Alasty, A ; Sharif University of Technology
    2013
    Abstract
    Nowadays, dynamic analysis of air-conditioner units is essential to achieve satisfactory comfort conditions in buildings with low energy consumption and operation cost. In this paper, a nonlinear multi input-multi output model (MIMO) of an air-handling unit (AHU) is considered. In the presence of realistic harmonic disturbances, nonlinear dynamics of AHU is investigated. The effect of various thermodynamics and geometrical parameters on limit cycles behaviour of the indoor temperature is investigated. It is observed that the indoor space volume plays as the bifurcation parameter of the system. Decreasing the indoor space volume leads to the occurrence of secondary Hopf (Neimark) bifurcation... 

    A new approach to exergy analyses of a hybrid desiccant cooling system compares to a vapor compression system

    , Article Applied Mechanics and Materials, 29 July 2011 through 31 July 2011 ; Volume 110-116 , July , 2012 , Pages 2163-2169 ; 16609336 (ISSN) ; 9783037852620 (ISBN) Khosravi, S ; Yau, Y. H ; Mahlia, T. M. I ; Saidi, M. H ; Sharif University of Technology
    Abstract
    In the recent researches HVAC with a based desiccant dehumidifier with a low ambient impact is more efficient in comparison to the traditional systems. Hybrid desiccant cooling systems can be used to control indoor air quality in buildings. This paper presents an integrated energy, entropy and exergy analysis of a hybrid desiccant cooling system compare to a compression system based on first and second laws of thermodynamic. The main objective is the use of a method called exergy costing applied to a conventional compression system that has been chosen to provide the proper conditioned air for a building in hot and humid condition. By applying the same method for the equivalent hybrid... 

    Using strongly connected components as a basis for autonomous skill acquisition in reinforcement learning

    , Article 6th International Symposium on Neural Networks, ISNN 2009, Wuhan, 26 May 2009 through 29 May 2009 ; Volume 5551 LNCS, Issue PART 1 , 2009 , Pages 794-803 ; 03029743 (ISSN); 3642015069 (ISBN); 9783642015069 (ISBN) Kazemitabar, J ; Beigy, H ; Sharif University of Technology
    2009
    Abstract
    Hierarchical reinforcement learning (HRL) has had a vast range of applications in recent years. Preparing mechanisms for autonomous acquisition of skills has been a main topic of research in this area. While different methods have been proposed to achieve this goal, few methods have been shown to be successful both in performance and also efficiency in terms of time complexity of the algorithm. In this paper, a linear time algorithm is proposed to find subgoal states of the environment in early episodes of learning. Having subgoals available in early phases of a learning task, results in building skills that dramatically increase the convergence rate of the learning process. © 2009 Springer... 

    An innovative executive and financial mechanism for energy conservation in new and existing buildings in Iran

    , Article International Journal of Environmental Science and Technology ; Volume 17, Issue 10 , 2020 , Pages 4217-4232 Abbasizade, F ; Abbaspour, M ; Soltanieh, M ; Kani, A ; Sharif University of Technology
    Springer  2020
    Abstract
    One of the most effective measures for building energy conservation is the implementation of energy codes. The building energy codes introduction in Iran started two decades after the first oil crisis in the early 1970s by establishing the building energy conservation regulation called Issue 19. Nowadays, due to some financial and executive barriers, the implementation of Issue 19 is faced with some difficulties. The most critical obstacle is the low price of energy carriers, which lead to high subsidies of energy and the reluctance of the building owners to implement the regulation. The main goal of this paper is the introduction of an innovative financial and executive mechanism for... 

    Adaptive model predictive climate control of multi-unit buildings using weather forecast data

    , Article Journal of Building Engineering ; Volume 32 , May , 2020 , Pages: 5-6 Mohammadzadeh Mazar, M ; Rezaeizadeh, A ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    Energy use in buildings contributes a large part in global energy demand. To reduce energy use in this group of consumers, specially in cold seasons, an automatic control technique is proposed. In this paper, a model predictive controller (MPC) is employed to minimize the boiler activation time. The method uses the building model and incorporates the weather forecast data to act on the actuator in an optimal fashion while treating the user comfort constraints. This technique, as a part, can be embedded into the building energy management system. The building model parameters are obtained via an online identification process using unscented kalman filter (UKF). This identification is... 

    Metal-organic frameworks (MOF) based heat transfer: A comprehensive review

    , Article Chemical Engineering Journal ; Volume 449 , 2022 ; 13858947 (ISSN) Moayed Mohseni, M ; Jouyandeh, M ; Mohammad Sajadi, S ; Hejna, A ; Habibzadeh, S ; Mohaddespour, A ; Rabiee, N ; Daneshgar, H ; Akhavan, O ; Asadnia, M ; Rabiee, M ; Ramakrishna, S ; Luque, R ; Reza Saeb, M ; Sharif University of Technology
    Elsevier B.V  2022
    Abstract
    Higher than a standard level, the humidity provides a suitable environment for the pathogenic microorganisms to grow and increases energy consumption for cooling, increasing greenhouse gas emissions. Desiccant air-conditioning (DAC) is an effective method to reduce humidity and energy simultaneously. Conventional desiccants are not suitable for use as a desiccant in building air conditioners, mainly because of high regeneration temperature and other issues such as limited equilibrium capacity and hydrothermal and cyclic instability. Metal-organic frameworks (MOFs) are a novel class of porous crystalline materials without the disadvantages of traditional desiccants. They benefit from a huge...