Loading...
Search for: ion-selective-electrode
0.012 seconds

    Development of Miniaturized Electrochemical Sensors Based on Ion-Selective Membrane for Environmental Applications

    , Ph.D. Dissertation Sharif University of Technology Dehabadi, Monireh (Author) ; Yaghmaei, Soheila (Supervisor) ; Legin, Andrey (Supervisor) ; Kirsanov, Dmitry (Supervisor) ; Babain, Vasiliy (Supervisor)
    Abstract
    The first study of the present research aims to the possibility of developing simple, accurate and selective potentiometric sensors for the detection of scandium ions in aqueous solution, which is done for the first time. In this study, a sensor array consisting of 17 miniaturized potentiometric sensors based on polymeric membranes containing various ion-extracting ligands were designed and fabricated. Ligands as the active component of the membranes included phosphine oxides and diamides of various organic acids, which were used in the extraction of rare earth metal ions. The possibility of using these extractants in the polymer matrix of membranes for the development of scandium-sensitive... 

    Preparation of a naltrexone HCL potentiometric sensor and its application to pharmaceutical analysis and drug determination in biological fluids

    , Article Journal of Food and Drug Analysis ; Volume 19, Issue 4 , 2011 , Pages 445-451+539 ; 10219498 (ISSN) Ghorbani Bidkorbeh, F ; Shahrokhian, S ; Mohammadi, A ; Dinarvand, R ; Sharif University of Technology
    Abstract
    A novel ion selective electrode is fabricated for naltrexone HCl and used in pharmaceutical analysis and drug determination in biological fluids without complicated pretreatments and extractions, using direct potentiometry. The naltrexone complex with sodium tetraphenyl borate (NaTPB) is obtained by in situ soaking PVC membrane electrode in an 1 × 10 -3 M naltrexone solution. The sensor exhibited fast, reproducible and linear sub-Nernstian response over concentration range of 1 × 10 -5 - 1 × 10 -3 M with a detection limit of 5 × 10 -6 M. The membrane sensor was successfully applied to the determination of naltrexone in capsules as well as for its determination in urine and plasma samples  

    Simultaneous determination of epinephrine and acetaminophen concentrations using a novel carbon paste electrode prepared with 2,2′-[1,2 butanediylbis(nitriloethylidyne)]-bis-hydroquinone and TiO2 nanoparticles

    , Article Colloids and Surfaces B: Biointerfaces ; Volume 76, Issue 1 , 2010 , Pages 82-87 ; 09277765 (ISSN) Mazloum Ardakani, M ; Beitollahi, H ; Sheikh Mohseni, M. A ; Benvidi, A ; Naeimi, H ; Nejati Barzoki, M ; Taghavinia, N ; Sharif University of Technology
    2010
    Abstract
    A carbon paste electrode (CPE) modified with 2,2′-[1,2 butanediylbis(nitriloethylidyne)]-bis-hydroquinone (BBNBH) and TiO2 nanoparticles was used for the sensitive voltammetric determination of epinephrine (EP). The electrochemical response characteristics of the modified electrode toward EP and acetaminophen (AC) were investigated by cyclic and differential pulse voltammetry (CV and DPV). The results showed an efficient catalytic activity of the electrode for the electrooxidation of EP, which leads to a reduction in its overpotential by more than 270 mV. The effects of pH and potential sweep rate on the mechanism of the electrode process were investigated. The modified electrode exhibits an... 

    Rhodium(II) phthalocyanine as a selective carrier in thiocyanate-selective membrane electrode

    , Article Analytical Letters ; Volume 38, Issue 8 , 2005 , Pages 1221-1235 ; 00032719 (ISSN) Shahrokhian, S ; Jannatrezvani, M. J ; Khajehsharifi, H ; Sharif University of Technology
    2005
    Abstract
    An anion-selective electrode based on rhodium(II) phthalocyanine (RhPc) as a neutral carrier is reported. The prepared electrode displays an anti-Hofmeister behavior with a high selectivity for thiocyanate. The potentiometric response characteristics and selectivities of the membrane electrodes with various ratios of cationic additive to ion-carrier indicate that the observed potentiometric response is based on the formation of a 1:1 complex between RhPc and thiocyanate as an axial ligand. The membrane electrodes containing ∼60 mol percent of cationic additive (relative to ionophore) exhibit a near-Nernstian response in a concentration range of thiocyanate between 1 × 10-6 M to 1 × 10-1 M, a... 

    Metalophthalocyanine complexes as ion-carriers in membrane-selective electrodes for detection of thiosalicylic acid

    , Article Analytica Chimica Acta ; Volume 518, Issue 1-2 , 2004 , Pages 101-108 ; 00032670 (ISSN) Shahrokhian, S ; Souri, A ; Sharif University of Technology
    2004
    Abstract
    The potentiometric response properties of several PVC-based membrane electrodes using phthalocyanine complexes of aluminum (AlPc), nickel (NiPc) and copper (CuPc) as anion carriers, toward thiosalicylic acid (TSA) were investigated. The influences of lipophilic ionic additives (cationic and anionic) and the pH of the buffered solutions were used for the interpretation of the mechanism of the potentiometric response of sensors. The sensitivity, linear range, detection limit, and potentiometric selectivity of the membrane sensors show a considerable dependence on the nature of central metal of the ionophore. The membrane electrodes based on AlPc demonstrate sub-Nernstian responses toward TSA... 

    Potentiometric membrane sensors based on zirconyl(IV) phthalocyanine for detection of sulfosalicylic acid

    , Article Talanta ; Volume 63, Issue 2 , 2004 , Pages 371-376 ; 00399140 (ISSN) Shahrokhian, S ; Taghani, A ; Hamzehloei, A ; Mousavi, S. R ; Sharif University of Technology
    Elsevier  2004
    Abstract
    A metallophthalocyanine complex with zirconium(IV) ion in the center (as an oxo-zirconium, Zr=O, group) was used in poly vinyl chloride (PVC) membranes for the selective detection of 5-sulfosalicylic acid (SSA). The resulting electrodes demonstrate Nernstian responses over a wide range of sulfosalicylic acid concentration (10-6 to 10-1 mol dm-3) with a slope of about -29 mV per decade. The influence of lipophilic ion-exchanger sites on the response properties of the electrodes was investigated. The optimal potentiometric response was observed for the electrode in the presence of about 150 mol% of cationic additive (relative to ionophore) in the phase membrane. The electrodes have a fast... 

    Measurement of activity coefficients of amino acids in aqueous electrolyte solutions: Experimental data for the systems (H2O + NaBr + glycine) and (H2O + NaBr + L-valine) at T = 298.15 K

    , Article Journal of Chemical Thermodynamics ; Volume 35, Issue 9 , 2003 , Pages 1553-1565 ; 00219614 (ISSN) Khavaninzadeh, A ; Modarress, H ; Taghikhani, V ; Khoshkbarchi, M. K ; Sharif University of Technology
    Academic Press  2003
    Abstract
    Electrochemical cells with two ion-selective electrodes, a cation ion-selective electrode against an anion ion-selective electrode, were used to measure the activity coefficient of amino acids in aqueous electrolyte solutions. Activity coefficient data were measured for (H2O + NaBr + glycine) and (H2O + NaBr + L-valine) at T = 298.15 K. The maximum concentrations of sodium bromide, glycine, and L-valine were (1.0, 2.4, and 0.4) mol · kg-1, respectively. The results show that the presence of an electrolyte and the nature of both the cation and the anion of the electrolyte have significant effects on the activity coefficients of amino acid in aqueous electrolyte solutions  

    Iodide-selective electrode based on copper phthalocyanine

    , Article Electroanalysis ; Volume 14, Issue 23 , 2002 , Pages 1621-1628 ; 10400397 (ISSN) Shahrokhian, S ; Taghani, A ; Moattar, F ; Sharif University of Technology
    2002
    Abstract
    Copper phthalocyanine was used as ion carrier for preparing polymeric membrane selective sensor for detection of iodide. The electrode was prepared by incorporating the ionophore into plasticized poly(vinyl chloride) (PVC) membrane, coated on the surface of graphite electrode. This novel electrode shows high selectivity for iodide with respect to many common inorganic and organic anions. The effects of membrane composition, pH and the influence of lipophilic cationic and anionic additives and also nature of plasticizer on the response characteristics of the electrode were investigated. A calibration plot with near-Nernestian slope for iodide was observed over a wide linear range of five... 

    Activity coefficients of electrolyte and amino acid in the systems (water + potassium chloride + DL-valine) at T = 298.15 K and (water + sodium chloride + L-valine) at T = 308.15 K

    , Article Journal of Chemical Thermodynamics ; Volume 34, Issue 8 , 2002 , Pages 1297-1309 ; 00219614 (ISSN) Khavaninzadeh, A ; Modarress, H ; Taghikhani, V ; Khoshkbarchi, M. K ; Sharif University of Technology
    2002
    Abstract
    The activity coefficient data were reported for (water + potassium chloride + DL-valine) at T = 298.15 K and (water + sodium chloride + L-valine) at T = 308.15 K. The measurements were performed in an electrochemical cell using ion-selective electrodes. The maximum concentrations of the electrolytes and the amino acids studied were 1.0 molality and 0.4 molality, respectively. The results of the activity coefficients of DL-valine are compared with the activity coefficients of DL-valine in (water + sodium chloride + DL-valine) system obtained from the previous study. The results show that the presence of an electrolyte and the nature of its cation have a significant effect on the activity... 

    Vanadyl and molybdenyl phthalocyanines as ionophores for salicylate-selective membranes coated on graphite electrodes

    , Article Analytical Letters ; Volume 34, Issue 5 , 2001 , Pages 661-674 ; 00032719 (ISSN) Firooz, A. R ; Amini, M. K ; Tangestaninejad, S ; Shahrokhian, S ; Sharif University of Technology
    2001
    Abstract
    Salicylate selective electrodes based on oxo(phthalocyanato)-vanadium(IV) [VO(Pc), vanadyl phthalocyanine] and oxo(phthalocyanato)molybdenum(IV) [MoO(Pc), molybdenyl phthalocyanine] are described. The electrodes were prepared by incorporating the ionophores into plasticized poly(vinyl chloride) membranes, which were directly coated on the surface of graphite electrodes. The resulting electrodes demonstrate Nernstian responses over a wide linear range (10-7-10-1 M) salicylate. The electrodes have a fast response time, submicromolar detection limit, and could be used over the pH range of 6-9. The proposed sensors revealed selectivity for salicylate over a number of common inorganic and organic...