Loading...
Search for: micromixer
0.012 seconds
Total 40 records

    Active microfluidic micromixer design using ionic polymer-metal composites

    , Article 27th Iranian Conference on Electrical Engineering, ICEE 2019, 30 April 2019 through 2 May 2019 ; 2019 , Pages 371-375 ; 9781728115085 (ISBN) Annabestani, M ; Mohammadzadeh, H ; Aghassizadeh, A ; Azizmohseni, S ; Fardmanesh, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    In most of the microfluidic applications, it is necessary to have a mixed fluid from the beginning, but in microchannels, due to facing with low Reynolds flows, the fluids flow in the channel by the laminar regimes. Hence the mixing process is a challenging problem and researchers are trying to present fast and reliable micromixers. In this paper, using Ionic Polymer-Metal Composites (IPMCs), an active micromixer has been designed. To investigate the appropriateness of IPMC, using experimental and simulation tests, we show that the IPMC actuator is a potential candidate as an active element of microfluidic micromixers  

    A depthwise averaging solution for cross-stream diffusion in a Y-micromixer by considering thick electrical double layers and nonlinear rheology

    , Article Microfluidics and Nanofluidics ; Volume 19, Issue 6 , 2015 , Pages 1297-1308 ; 16134982 (ISSN) Ahmadian Yazdi, A ; Sadeghi, A ; Saidi, M. H ; Sharif University of Technology
    Springer Verlag  2015
    Abstract
    Both nonlinear rheology and finite EDL thickness effects on the mixing process in an electroosmotically actuated Y-sensor are being investigated in this paper, utilizing a depthwise averaging method based on the Taylor dispersion theory. The fluid rheological behavior is assumed to obey the power-law viscosity model. Analytical solutions are obtained assuming a large channel width to depth ratio for which a 1-D profile can efficiently describe the velocity distribution. Full numerical simulations are also performed to determine the applicability range of the analytical model, revealing that it is able to provide accurate results for channel aspect ratios of ten and higher and quite... 

    A microfluidic concentration gradient generator for simultaneous delivery of two reagents on a millimeter-sized sample

    , Article Journal of Flow Chemistry ; Volume 10, Issue 4 , 2020 , Pages 615-625 Rismanian, M ; Saidi, M. S ; Kashaninejad, N ; Sharif University of Technology
    Springer International Publishing  2020
    Abstract
    Microfluidic concentration gradient generators (μCGGs) are indispensable parts of many emerging lab-on-a-chip platforms for biological studies and drug delivery applications. Most of the μCGGs reported in the literature can only generate the desired concentration gradients in a micron-sized sample (e.g., cells). As such, there is an unmet need to design a μCGG that can generate continuous concentration gradients of multi reagents (e.g., drugs) in a millimeter-sized sample (e.g., tissue). Herein, we report the proof-of-concept of this class of μCGG by combining a modified tree-like CGG with a micromixer. By conducting both experimental investigation and numerical analysis, we show that the... 

    Analyzing mixing quality in a curved centrifugal micromixer through numerical simulation

    , Article Chemical Engineering and Processing: Process Intensification ; 2017 ; 02552701 (ISSN) Shamloo, A ; Vatankhah, P ; Akbari, A ; Sharif University of Technology
    Elsevier B.V 
    Abstract
    The Lab On a CD (LOCD), also known as Centrifugal Microfluidics, has evolved into a sophisticated platform for performing biomedical assays due to its marvelous miniaturization and accurate simulation of biological reactions. Among the numerous applications of the LOCD is fluid mixing. In this paper a centrifugal, serpentine micromixer is simulated and reformed toward better mixing performance. The micromixer was chosen to be curved as a curved design was found to be thrice as functional and compact as a rectilinear design, mixing-wise. The two angular velocity and opening radius parameters were originally hypothesized to affect mixing performance. Effect of angular velocity was studied over... 

    Analyzing mixing quality in a curved centrifugal micromixer through numerical simulation

    , Article Chemical Engineering and Processing: Process Intensification ; Volume 116 , 2017 , Pages 9-16 ; 02552701 (ISSN) Shamloo, A ; Vatankhah, P ; Akbari, A ; Sharif University of Technology
    Elsevier B.V  2017
    Abstract
    The Lab On a CD (LOCD), also known as Centrifugal Microfluidics, has evolved into a sophisticated platform for performing biomedical assays due to its marvelous miniaturization and accurate simulation of biological reactions. Among the numerous applications of the LOCD is fluid mixing. In this paper a centrifugal, serpentine micromixer is simulated and reformed toward better mixing performance. The micromixer was chosen to be curved as a curved design was found to be thrice as functional and compact as a rectilinear design, mixing-wise. The two angular velocity and opening radius parameters were originally hypothesized to affect mixing performance. Effect of angular velocity was studied over... 

    A new non-dimensional parameter to obtain the minimum mixing length in tree-like concentration gradient generators

    , Article Chemical Engineering Science ; Volume 195 , 2019 , Pages 120-126 ; 00092509 (ISSN) Rismanian, M ; Saidi, M. S ; Kashaninejad, N ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    Microfluidic-based concentration gradient generators (CGGs) have a number of applications in chemical, biological and pharmaceutical studies. Thus, precise design of the microfluidic system is crucial to maintaining the desired concentration gradient in microchannels. One of the design considerations is the length of microchannels in the structure of a CGG. A CGG with a short length fails to provide the complete diffusive mixing, while the size of the microchip would unfavorably increase by incorporating a long CGG. Considering a CGG as a tree-like structure consisting of T-shaped micromixers, the mixing process of the species at a straight microchannel has been solved analytically. Herein,... 

    A new scheme for improving the mixing efficiency in micro scale

    , Article ASME 2011 9th International Conference on Nanochannels, Microchannels, and Minichannels, ICNMM 2011 ; Volume 1 , 2011 , Pages 183-191 ; 9780791844632 (ISBN) Anbari, A. M ; Haroutunian, A ; Saidi, M. S ; Shafii, M. B ; Sharif University of Technology
    2011
    Abstract
    Generally speaking, most micro-fluidic mixing systems are limited to the low Reynolds number regime in which diffusion dominates convection, and consequently the mixing process tends to be slow and it takes a relatively long time to have two fluids completely mixed. Therefore, rapid mixing is essential in micro-fluidic systems. In order to hasten the mixing process in micro scale, in this study we come up with a novel scheme for a two dimensional micro-fluidic mixer which encompasses three pairs of electrodes, one pair embedded in the mixing chamber and two pairs located in the micro-channels before and after the mixing chamber. The width of the middle pair is assumed to be twice of the... 

    Computational study of an integrated microfluidic device for active separation of RBCs and cell lysis

    , Article Chemical Engineering and Processing - Process Intensification ; Volume 174 , 2022 ; 02552701 (ISSN) Jalilvand, E ; Shamloo, A ; Gangaraj, M. H ; Sharif University of Technology
    Elsevier B.V  2022
    Abstract
    Separation and lysis of RBCs play an important role in diagnosis of different diseases. Although they have been partially studied in several researches, a comprehensive study on integrating both separation and lysis units on a single chip has been seen rarely in the literature. Also, the factors related to the chemical lysis process have not been investigated in detail. In this study, we introduce a novel microfluidic channel design for sequential RBC's separation and lysis. For the separation part, an active method with an electric field was applied to the cells. Besides, a novel mixer was designed for mixing the cell solution and lysis reagent. In the lysis section, we used a mathematical... 

    Design and simulation of an integrated centrifugal microfluidic device for CTCs separation and cell lysis

    , Article Micromachines ; Volume 11, Issue 7 , July , 2020 Nasiri, R ; Shamloo, A ; Akbari, J ; Tebon, P ; Dokmeci, M. R ; Ahadian, S ; Sharif University of Technology
    MDPI AG  2020
    Abstract
    Separation of circulating tumor cells (CTCs) from blood samples and subsequent DNA extraction from these cells play a crucial role in cancer research and drug discovery. Microfluidics is a versatile technology that has been applied to create niche solutions to biomedical applications, such as cell separation and mixing, droplet generation, bioprinting, and organs on a chip. Centrifugal microfluidic biochips created on compact disks show great potential in processing biological samples for point of care diagnostics. This study investigates the design and numerical simulation of an integrated microfluidic device, including a cell separation unit for isolating CTCs from a blood sample and a... 

    Electrokinetic mixing at high zeta potentials: Ionic size effects on cross stream diffusion

    , Article Journal of Colloid and Interface Science ; Volume 442 , 2015 , Pages 8-14 ; 00219797 (ISSN) Ahmadian Yazdi, A ; Sadeghi, A ; Saidi, M. H ; Sharif University of Technology
    Academic Press Inc  2015
    Abstract
    The electrokinetic phenomena at high zeta potentials may show several unique features which are not normally observed. One of these features is the ionic size (steric) effect associated with the solutions of high ionic concentration. In the present work, attention is given to the influences of finite ionic size on the cross stream diffusion process in an electrokinetically actuated Y-shaped micromixer. The method consists of a finite difference based numerical approach for non-uniform grid which is applied to the dimensionless form of the governing equations, including the modified Poisson-Boltzmann equation. The results reveal that, neglecting the ionic size at high zeta potentials gives... 

    Experimental investigation and process intensification of barium sulfate nanoparticles synthesis via a new double coaxial spinning disks reactor

    , Article Chemical Engineering and Processing: Process Intensification ; Volume 115 , 2017 , Pages 11-22 ; 02552701 (ISSN) Bagheri Farahani, H ; Shahrokhi, M ; Molaei Dehkordi, A ; Sharif University of Technology
    Elsevier B.V  2017
    Abstract
    In this article, a new double spinning disks reactor (DSDR) has been proposed and tested successfully for the synthesis of barium sulfate nanoparticles by means of the reactive precipitation. The proposed DSDR consists of two coaxial rotating disks placed horizontally in a cylindrical chamber. Continuous precipitation of barium sulfate nanoparticles as a chemical test system was carried out using this new contacting device and the effects of operating and design parameters such as the disk rotational speed, distance between the disks, feed concentration, feed flow rate, free ion ratio, feed location, and feed distribution pattern on the mean size, size distribution, and morphology of the... 

    Investigation of a Novel Microfluidic Device for Label-Free Ferrohydrodynamic Cell Separation on a Rotating Disk

    , Article IEEE Transactions on Biomedical Engineering ; Volume 67, Issue 2 , 2020 , Pages 372-378 Shamloo, A ; Besanjideh, M ; Sharif University of Technology
    IEEE Computer Society  2020
    Abstract
    Negative magnetophoresis is a novel and attractive method for continuous microparticle sorting inside a magnetic medium. In this method, diamagnetic particles are sorted based on their sizes using magnetic buoyancy force and without any labeling process. Although this method provides some attractive features, such as low-cost fabrication and ease of operation, there are some obstacles that adversely affect its performance, especially for biological applications. Most types of magnetic media, such as ferrofluids, are not biocompatible, and the time-consuming process of sample preparation can be threatening to the viability of the cells within the sample. Furthermore, in this method, both the... 

    Mixing performance of T, Y, and oriented Y-micromixers with spatially arranged outlet channel: evaluation with villermaux/dushman test reaction

    , Article Microsystem Technologies ; 2016 , Pages 1-14 ; 09467076 (ISSN) Rahimi, M ; Azimi, N ; Parsamogadam, M. A ; Rahimi, A ; Masahy, M. M ; Sharif University of Technology
    Springer Verlag  2016
    Abstract
    This study aims to investigate the micromixing performance of three basic types of spatial shaped micromixers. New configurations of T, Y, and oriented Y-spatial mixers were designed with change in the angles of the confluence and the outlet channel to achieve the efficient micromixing. These micromixers offer advantages that are not attainable with the typical types of these mixers. Experimental tests were carried out in the laminar flow regime and the mixing efficiency was evaluated using Villermaux/Dushman test reaction. The geometries of the channels were cylindrical with the length of 30 mm and the diameter of 800 μm. The experimental results show that the angle of outlet channel has a... 

    Mixing performance of T, Y, and oriented Y-micromixers with spatially arranged outlet channel: evaluation with Villermaux/Dushman test reaction

    , Article Microsystem Technologies ; Volume 23, Issue 8 , 2017 , Pages 3117-3130 ; 09467076 (ISSN) Rahimi, M ; Azimi, N ; Parsamogadam, M. A ; Rahimi, A ; Masahy, M. M ; Sharif University of Technology
    Springer Verlag  2017
    Abstract
    This study aims to investigate the micromixing performance of three basic types of spatial shaped micromixers. New configurations of T, Y, and oriented Y-spatial mixers were designed with change in the angles of the confluence and the outlet channel to achieve the efficient micromixing. These micromixers offer advantages that are not attainable with the typical types of these mixers. Experimental tests were carried out in the laminar flow regime and the mixing efficiency was evaluated using Villermaux/Dushman test reaction. The geometries of the channels were cylindrical with the length of 30 mm and the diameter of 800 μm. The experimental results show that the angle of outlet channel has a... 

    Modeling active micromixers with multiple microstirrers using smoothed particle hydrodynamics

    , Article Scientia Iranica ; Vol. 21, issue. 4 , 2014 , pp. 1390-1402 ; ISSN: 10263098 Jafarian, A ; Pishevar, A ; Saidi, M. S ; Sharif University of Technology
    Abstract
    The smoothed particle hydrodynamics method is used to explore the effects of design parameters on the mixing efficiency of two types of active micromixer. First, the complex flow field and the mixing process of two separated fluids in a square mixing chamber with nine symmetric microstirrers are simulated. The influence of design parameters, such as the microstirrer rotation arrangement and the angular velocity of the microstirrer, on the mixing performance, is investigated. The mixing index parameter on ten control points is calculated and the average mixing index is compared for different cases. Simulations illustrate that the rotation arrangement of microstirrers is a key parameter in the... 

    Multiphysics analysis and practical implementation of a soft μ-actuator- based microfluidic micromixer

    , Article Journal of Microelectromechanical Systems ; Volume 29, Issue 2 , 2020 , Pages 268-276 Annabestani, M ; Azizmohseni, S ; Esmaeili Dokht, P ; Bagheri, N ; Aghassizadeh, A ; Fardmanesh, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    Electroactive-Polymers (EAPs) are one of the best soft $mu $ -actuators with great biomedical applications. Ionic ones (i-EAPs) have more promising features and have adequate potential for using in the active microfluidic devices. Here, as a case study, we have designed and fabricated a microfluidic micromixer using an i-EAP named Ionic Polymer-Metal Composite (IPMC). In microfluidics, active devices have more functionality but due to their required facilities are less effective for Point of Care Tests (POCTs). In the direction of solving this paradox, we should use some active components that they need minimum facilities. IPMC can be one of these components, hence by integrating the IPMC... 

    Numerical investigation on mixing intensification of ferrofluid and deionized water inside a microchannel using magnetic actuation generated by embedded microcoils for lab-on-chip systems

    , Article Chemical Engineering and Processing - Process Intensification ; Volume 147 , 2020 Saadat, M ; Shafii, M. B ; Ghassemi, M ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Effective and rapid mixing is crucial for chemical and biological processes. The purpose of the current study is to investigate the effect of steady and varying magnetic field on the mixing of a water-based ferrofluid and two streams of deionized water inside a microchannel for Lab-on-Chip applications. To this end, the nonlinear governing equations, the momentum equation, the continuity equation, the mass transport equation and the Maxwell-Ampere equations are numerically solved. A commercial code based on the finite-element method is used and the numerical simulations are validated by the experimental results in the literature. To augment the mixing performance, the effects of influencing... 

    Numerical investigation on the effect of external varying magnetic field on the mixing of ferrofluid with deionized water inside a microchannel for lab-on-chip systems

    , Article Energy Sources, Part A: Recovery, Utilization and Environmental Effects ; 2020 Saadat, M ; Ghassemi, M ; Shafii, M. B ; Sharif University of Technology
    Taylor and Francis Inc  2020
    Abstract
    Energy-efficient mixing is vital for chemical and fuel processes. To this end, a flow-focusing configuration is proposed to investigate the effect of a uniform magnetic field on the mixing of a water-based ferrofluid with two streams of deionized water. An external and varying magnetic field is imposed on a straight microchannel, and the mixing between the ferrofluid and deionized waters is qualitatively and quantitatively measured. A commercial code based on the finite-element method is used, and the simulations are validated by two experimental studies in the literature. For a magnetic flux density of 10 mT, a signal frequency of 1 Hz, a duty cycle of 0.3, an inlet velocity of 500 µm/s,... 

    Numerical simulation of centrifugal serpentine micromixers and analyzing mixing quality parameters

    , Article Chemical Engineering and Processing: Process Intensification ; Volume 104 , 2016 , Pages 243-252 ; 02552701 (ISSN) Shamloo, A ; Madadelahi, M ; Akbari, A ; Sharif University of Technology
    Elsevier, B.V  2016
    Abstract
    Centrifugal microfluidics or the Lab on a CD (LOCD) has developed vast applications in biomedical researches and analyses. Fluid mixing is an application of the LOCD. In this paper, multiple centrifugal micromixers were simulated. Various parameters were originally presumed to have an effect on mixing performance. These parameters include inlet angle, angular velocity, cross-sectional profile, perpendicular length ratio and the number of channels in series. They were each analyzed through simulations. It was gathered that the inlet angle does not significantly affect the mixing quality. Increasing angular velocity steadily increases mixing quality for all geometries. The vertical triangular... 

    Numerical simulation of mixing and heat transfer in an integrated centrifugal microfluidic system for nested-PCR amplification and gene detection

    , Article Sensors and Actuators, B: Chemical ; Volume 283 , 2019 , Pages 831-841 ; 09254005 (ISSN) Naghdloo, A ; Ghazimirsaeed, E ; Shamloo, A ; Sharif University of Technology
    Elsevier B.V  2019
    Abstract
    Nucleic acid amplification via polymerase chain reaction (PCR) is one of the essential and powerful methods used in a myriad of bio-assays in clinical laboratories. Application of microfluidic devices in biologically-related processes like PCR can result in the usage of less volume of reactant samples and reduce the processing time. By implementing PCR systems on centrifugal microfluidic platforms, automation and portability can be easily achieved. Although several methods have been developed, most of them are still dealing with challenges of the required high processing time. This study presents the numerical simulation of a fully automated PCR system with the goal of enhancing the mixing...