Loading...
Search for: modified-glassy-carbon-electrode
0.012 seconds

    Facile electrochemical detection of morpholine in boiler water with carbon nanostructures: a comparative study of graphene and carbon nanotubes

    , Article Bulletin of Materials Science ; Volume 45, Issue 2 , 2022 ; 02504707 (ISSN) de Oliveira, S. M ; dos Santos Castro Assis, K. L ; Paiva, V. M ; Hashempour, M ; Bestetti, M ; de Araújo, J. R ; D’Elia, E ; Sharif University of Technology
    Springer  2022
    Abstract
    Two electrochemical sensors based on modified glassy carbon electrodes with carbon nanostructures as graphene (GCE–EG) and carbon nanotubes (GCE–CNT) were evaluated for morpholine analysis. The carbon nanostructures were obtained and characterized using X-ray photoelectron spectroscopy, Raman spectroscopy, X-ray diffraction, transmission electron microscopy, high-resolution transmission electron microscopy and cyclic voltammetry. All spectroscopic and microscopic techniques confirmed the procurement of graphene and CNT. The electrochemical studies proved the efficient behaviour of both electrodes GCE–EG and GCE–CNT in sensing and detection of morpholine via differential pulse voltammetry.... 

    Highly sensitive nonenzymetic glucose sensing platform based on MOF-derived NiCo LDH nanosheets/graphene nanoribbons composite

    , Article Journal of Electroanalytical Chemistry ; Volume 808 , 2018 , Pages 114-123 ; 15726657 (ISSN) Asadian, E ; Shahrokhian, S ; Iraji Zad, A ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    Herein, a novel sensing platform based on NiCo layered double hydroxide (LDH) nanosheets/graphene nanoribbons (GNRs) modified glassy carbon electrode is presented for sensitive non-enzymetic determination of glucose. In the first step, nanoflower-like NiCo LDH nanosheets were grown on the surface of ZIF-67 dodecahedron nanocrystals which used as sacrificial template and were further characterized by means of scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDX), X-ray powder diffraction (XRD) and FTIR. In the next step, in order to fabricate a mechanically stable modified electrode, the as-prepared nanosheets were mixed with... 

    Silver nanowires immobilized on gold-modified glassy carbon electrode for electrochemical quantification of atorvastatin

    , Article Journal of Electroanalytical Chemistry ; Volume 876 , November , 2020 Naseri, A ; Hormozi Nezhad, M. R ; Shahrokhian, S ; Asadian, E ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Development of simple yet precise sensing platforms for rapid determination of biological species and drugs is of paramount importance, not only for analysis of pharmaceutical formulations during the production stage, but also in clinical practices and medical diagnosis. In the present research, we report on the electrochemical determination of atorvastatin (ATOR) by using silver nanowires/gold-modified glassy carbon electrode (Ag NWs/Au/GCE). The modified electrode was constructed through a two-step procedure in which narrow silver nanowires synthesized via a polyol method are drop casted on a pre-modified GCE with electrodeposited gold particles. The results of XRD analysis indicated the... 

    Development of a nanocellulose composite based voltammetric sensor for vitamin B9 analysis

    , Article Current Nanoscience ; Volume 12, Issue 4 , 2016 , Pages 493-499 ; 15734137 (ISSN) Ghalkhani, M ; Shahrokhian, S ; Sharif University of Technology
    Bentham Science Publishers B.V 
    Abstract
    As a B group vitamins, vitamin B9 is a Water-soluble vitamin which is produced by plants and microorganisms (bacteria and yeasts). Vitamin B9 plays an important role in the production of proteins and nucleic acids in body and also is one of the substances that prevents the development of neural tube defects in the fetus. Methods: Electrochemical behavior of vitamin B9 was studied using a potentiostat/galvanostat SAMA 500, electroanalyzer system, I. R. Iran. A three-electrode system was used, including a glassy carbon working electrode (d = 2.0 mm, purchased from Azar Electrode Co., Urmia, I.R. Iran), an Ag/AgCl (saturated KCl) reference electrode and a Pt wire auxiliary electrode.... 

    Kinetic interpretation of a negative time constant impedance of glucose electrooxidation

    , Article Journal of Physical Chemistry B ; Volume 112, Issue 49 , 2008 , Pages 15933-15940 ; 15206106 (ISSN) Danaee, I ; Jafarian, M ; Forouzandeh, F ; Gobal, F ; Mahjani, M. G ; Sharif University of Technology
    American Chemical Society  2008
    Abstract
    Nickel - copper alloy modified glassy carbon electrodes (GC/NiCu) prepared by galvanostatic deposition were used for the electrocatalytic oxidation of glucose in alkaline solutions. The electro-oxidation of glucose in a 1 M NaOH solution at different concentration of glucose was studied by the method of ac-impedance spectroscopy. The impedance behavior show different patterns, capacitive, and inductive loops and negative resistances, at different applied anodic potential. The influence of the electrode potential on the impedance pattern is studied and a quantitative explanation for the impedance behavior of glucose oxidation is put forward by a proposed mathematical model. At potentials... 

    In-situ electro-polymerization of graphene nanoribbon/polyaniline composite film: Application to sensitive electrochemical detection of dobutamine

    , Article Sensors and Actuators, B: Chemical ; Vol. 196 , June , 2014 , pp. 582-588 ; ISSN: 09254005 Asadian, E ; Shahrokhian, S ; Zad, A. I ; Jokar, E ; Sharif University of Technology
    Abstract
    The present paper demonstrates the capability of narrow graphene nanoribbons (GNRs) in constructing new sensing platforms. Graphene nanoribbons have been synthesized via a simple solvothermal route through unzipping of carbon nanotubes, which was confirmed by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD) and Raman spectroscopy analysis. These narrow carbon sheets were used to form a composite film by in-situ electro-polymerization with aniline. The produced graphene nanoribbon/polyaniline (GNR/PANI) composite film showed impressive performance in electrochemical determination of dobutamine (DBT). Under optimal conditions, in comparison to... 

    Adsorptive stripping differential pulse voltammetric determination of mebendazole at a graphene nanosheets and carbon nanospheres/chitosan modified glassy carbon electrode

    , Article Sensors and Actuators, B: Chemical ; Volume 185 , 2013 , Pages 669-674 ; 09254005 (ISSN) Ghalkhani, M ; Shahrokhian, S ; Sharif University of Technology
    2013
    Abstract
    For the first time graphene nanosheets and carbon nanospheres/chitosan (GNS-CNS/CS) based nanocomposite film modified electrode was used for the electro-oxidation of mebendazole (MD). MD is a benzimidazole drug that is used to treat human infections caused by parasitic worms. MD causes slow immobilization and death of the worms by selectively and irreversibly blocking uptake of glucose. The electrochemical behavior of MD at GNS-CNS/CS modified glassy carbon electrode has been investigated using cyclic and differential pulse voltammetry in aqueous media at different pHs. The prepared electrode showed an excellent electrochemical activity toward the electro-oxidation of MD leading to a... 

    Electrochemical deposition of gold nanoparticles on carbon nanotube coated glassy carbon electrode for the improved sensing of tinidazole

    , Article Electrochimica Acta ; Volume 78 , September , 2012 , Pages 422-429 ; 00134686 (ISSN) Shahrokhian, S ; Rastgar, S ; Sharif University of Technology
    2012
    Abstract
    The electrochemical reduction of tinidazole (TNZ) is studied on gold-nanoparticle/carbon-nanotubes (AuNP/CNT) modified glassy carbon electrodes using the linear sweep voltammetry. An electrochemical procedure was used for the deposition of gold nanoparticles onto the carbon nanotube film pre-cast on a glassy carbon electrode surface. The resulting nanoparticles were characterized by scanning electron microscopy and cyclic voltammetry. The effect of the electrodeposition conditions, e.g., salt concentration and deposition time on the response of the electrode was studied. Also, the effect of experimental parameters, e.g., potential and time of accumulation, pH of the buffered solutions and... 

    A comparative investigation of the electrocatalytic oxidation of methanol on poly-NiTCPP and poly-TCPP/Ni modified glassy carbon electrodes

    , Article Journal of Electroanalytical Chemistry ; Volume 663, Issue 1 , December , 2011 , Pages 14-23 ; 15726657 (ISSN) Jafarian, M ; Haghighatbin, M. A ; Gobal, F ; Mahjani, M. G ; Rayati, S ; Sharif University of Technology
    2011
    Abstract
    Electro-oxidation of methanol in alkaline solution at a glassy carbon electrode electrochemically modified by a conductive polymeric meso-tetra(4-carboxyphenyl)porphyrinato nickel(II), abbreviated as poly-NiTCPP and also meso-tetra(4-carboxyphenyl)porphyrin with incorporated nickel(II) cations, abbreviated as, poly-TCPP/Ni, were investigated and compared. Both films were prepared by oxidative electro-polymerization of complexes by repetitive cyclic voltammetry (RCV) in 0.1 M NaOH aqueous solution. The electrochemical properties and behaviors and also kinetic values of both films have been characterized and compared using cyclic voltammetry (CV), chronoamperometry (CA) and electrochemical... 

    Electrodeposition of Pt-Ru nanoparticles on multi-walled carbon nanotubes: Application in sensitive voltammetric determination of methyldopa

    , Article Electrochimica Acta ; Volume 58, Issue 1 , 2011 , Pages 125-133 ; 00134686 (ISSN) Shahrokhian, S ; Rastgar, S ; Sharif University of Technology
    2011
    Abstract
    A modified glassy carbon electrode, prepared by potentiostatic electrodeposition of platinum-ruthenium nanoparticles (Pt-RuNPs) onto a multi-walled carbon nanotube (MWCNT) layer, offers dramatic improvements in the stability and sensitivity of voltammetric responses toward methyldopa (m-dopa) compared to glassy carbon electrodes individually coated with MWCNT or Pt-RuNPs. The surface morphology and nature of the hybrid film (Pt-RuNPs/MWCNT) deposited on glassy carbon electrodes was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques. A remarkable enhancement in the microscopic area of the electrode together... 

    Simultaneous voltammetric determination of tramadol and acetaminophen using carbon nanoparticles modified glassy carbon electrode

    , Article Electrochimica Acta ; Volume 55, Issue 8 , 2010 , Pages 2752-2759 ; 00134686 (ISSN) Ghorbani Bidkorbeh, F ; Shahrokhian, S ; Mohammadi, A ; Dinarvand, R ; Sharif University of Technology
    2010
    Abstract
    A sensitive and selective electrochemical sensor was fabricated via the drop-casting of carbon nanoparticles (CNPs) suspension onto a glassy carbon electrode (GCE). The application of this sensor was investigated in simultaneous determination of acetaminophen (ACE) and tramadol (TRA) drugs in pharmaceutical dosage form and ACE determination in human plasma. In order to study the electrochemical behaviors of the drugs, cyclic and differential pulse voltammetric studies of ACE and TRA were carried out at the surfaces of the modified GCE (MGCE) and the bare GCE. The dependence of peak currents and potentials on pH, concentration and the potential scan rate were investigated for these compounds... 

    Amine functionalized TiO2 coated on carbon nanotube as a nanomaterial for direct electrochemistry of glucose oxidase and glucose biosensing

    , Article Journal of Molecular Catalysis B: Enzymatic ; Volume 68, Issue 2 , 2011 , Pages 206-210 ; 13811177 (ISSN) Tasviri, M ; Rafiee Pour, H. A ; Ghourchian, H ; Gholami, M. R ; Sharif University of Technology
    Abstract
    A nano-composite material consisting of amine functionalized TiO 2-coated carbon nanotubes was prepared and used for glucose oxidase (GOx) absorption. The GOx bearing nanomaterial was fixed on a glassy carbon electrode to construct a novel biosensor for glucose determination. The direct electrochemistry of immobilized GOx and its electron transfer parameters at the modified glassy carbon electrode were reported. The apparent heterogeneous electron transfer rate constant (ks) of GOx was estimated to be 3.5 s-1, which is higher than those reported previously. Amperometric detection of glucose resulted in a rapid (3 s) and stable response in the linear concentration range from 1.8 to 266 μM.... 

    Modified glassy carbon electrodes based on carbon nanostructures for ultrasensitive electrochemical determination of furazolidone

    , Article Materials Science and Engineering C ; Volume 61 , 2016 , Pages 842-850 ; 09284931 (ISSN) Shahrokhian, S ; Naderi, L ; Ghalkhani, M ; Sharif University of Technology
    Abstract
    The electrochemical behavior of Furazolidone (Fu) was investigated on the surface of the glassy carbon electrode modified with different carbon nanomaterials, including carbon nanotubes (CNTs), carbon nanoparticles (CNPs), nanodiamond-graphite (NDG), graphene oxide (GO), reduced graphene oxide (RGO) and RGO-CNT hybrids (various ratios) using linear sweep voltammetry (LSV). The results of voltammetric studies exhibited a considerable increase in the cathodic peak current of Fu at the RGO modified GCE, compared to other modified electrodes and also bare GCE. The surface morphology and nature of the RGO film was thoroughly characterized by scanning electron microscopy (SEM), atomic force... 

    Electrocatalytic oxidation of glucose on Ni and NiCu alloy modified glassy carbon electrode

    , Article Journal of Solid State Electrochemistry ; Volume 13, Issue 8 , 2009 , Pages 1171-1179 ; 14328488 (ISSN) Jafarian, M ; Forouzandeh, F ; Danaee, I ; Gobal, F ; Mahjani, M. G ; Sharif University of Technology
    2009
    Abstract
    Nickel and nickel-copper alloy modified glassy carbon electrodes (GC/Ni and GC/NiCu) prepared by galvanostatic deposition were examined for their redox processes and electro-catalytic activities towards the oxidation of glucose in alkaline solutions. The methods of cyclic voltammetry (CV) and chronoamperometry (CA) were employed. The cyclic voltammogram of NiCu alloy demonstrates the formation of β/β crystallographic forms of the nickel oxyhydroxide under prolonged repetitive potential cycling in alkaline solution. It is also observed that the overpotential for O 2 evolution increases for NiCu alloy modified electrode. In CV studies, NiCu alloy modified electrode yields significantly higher... 

    Electrocatalytic oxidation of methanol on Ni and NiCu alloy modified glassy carbon electrode

    , Article International Journal of Hydrogen Energy ; Volume 33, Issue 16 , August , 2008 , Pages 4367-4376 ; 03603199 (ISSN) Danaee, I ; Jafarian, M ; Forouzandeh, F ; Gobal, F ; Mahjani, M. G ; Sharif University of Technology
    2008
    Abstract
    Nickel and nickel-copper alloy modified glassy carbon electrodes (GC/Ni and GC/NiCu) prepared by galvanostatic deposition were examined for their redox process and electrocatalytic activities towards the oxidation of methanol in alkaline solutions. The methods of cyclic voltammetery (CV) and chronoamperometry (CA) were employed. The cyclic voltammogram of NiCu alloy demonstrates the formation of β/β crystallographic forms of the nickel oxyhydroxide under prolonged repetitive potential cycling in alkaline solution. In CV studies, in the presence of methanol NiCu alloy modified electrode shows a significantly higher response for methanol oxidation. The peak current of the oxidation of nickel...