Loading...
Search for: modulation-transfer-function
0.005 seconds

    A fast optimization method for extension of depth-of-field in three-dimensional task-specific imaging systems

    , Article IEEE/OSA Journal of Display Technology ; Volume 6, Issue 10 , August , 2010 , Pages 412-421 ; 1551319X (ISSN) Bagheri, S ; Kavehvash, Z ; Mehrany, K ; Javidi, B ; Sharif University of Technology
    2010
    Abstract
    In this paper, we present a novel approach to generate images of extended depth-of-field (DOF) to support realization of three-dimensional (3D) imaging systems such as integral imaging. In our approach in extending the DOF, we take advantage of the spatial frequency spectrum of the object specific to the task in hand. The pupil function is thus engineered in such a fashion that the modulation transfer function (MTF) is maximized only in these selected spatial frequencies. We extract these high energy spatial frequencies using the principal component analysis (PCA) method. Moreover, given the need for many pupil function engineering steps in 3D imaging systems, we have constructed an... 

    Extension of depth of field using amplitude modulation of the pupil function for bio-imaging

    , Article Proceedings of SPIE - The International Society for Optical Engineering, 6 April 2010 through 8 April 2010 ; Volume 7690 , May , 2010 ; 0277786X (ISSN) ; 9780819481542 (ISBN) Kavehvash, Z ; Bagheri, S ; Mehrany, K ; Javidi, B ; Sanchez, E ; Martinez Corral, M ; Sharif University of Technology
    2010
    Abstract
    In this paper we present a novel approach to generate images of extended depth of field (DOF) without compromising the lateral resolution to support realization of three-dimensional imaging systems such as integral imaging. In our approach in extending DOF, we take advantage of the spatial frequency spectrum of the object specific to the task in hand. The pupil function is thus engineered in such a fashion that the modulation transfer function (MTF) is maximized only in these selected spatial frequencies. We extract these high energy spatial frequencies using PCA method. The advantage of our approach is illustrated using an amplitude modulation and a phase modulation example. In these... 

    Directed functional networks in Alzheimer's disease: disruption of global and local connectivity measures

    , Article IEEE Journal of Biomedical and Health Informatics ; Volume 21, Issue 4 , 2017 , Pages 949-955 ; 21682194 (ISSN) Afshari, S ; Jalili, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    Techniques available in graph theory can be applied to signals recorded from human brain. In network analysis of EEG signals, the individual nodes are EEG sensor locations and the edges correspond to functional relations between them that are extracted from EEG time series. In this paper, we study EEG-based directed functional networks in Alzheimer's disease (AD). To this end, directed connectivity matrices of 25 AD patients and 26 healthy subjects are processed and a number of meaningful graph theory metrics are studied. Our data show that functional networks of AD brains have significantly reduced global connectivity in alpha and beta bands (P < 0.05). The AD brains have significantly... 

    A novel method for measuring the MTF of CT scanners: A phantom study

    , Article 2019 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2019, 26 June 2019 through 28 June 2019 ; 2019 ; 9781538684276 (ISBN) Khodajou Chokami, H ; Hosseini, S. A ; Reza Ay, M ; Safarzadehamiri, A ; Ghafarian, P ; Zaidi, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    The modulation transfer function (MTF) is well known as a crucial parameter in quality assurance of computed tomography (CT) scanners, which provides detailed information of both contrast and resolution of CT images. Different methods have been introduced and developed to calculate the MTF of CT scanners. However, a robust methodology which accurately estimates the MTF of CT scanners under the use of every range of object electron density and tube current-time product (mAs) has not been reported so far. To this aim, a new wavelet-based circular edge method for MTF measurement has been presented in this work. Owning to the edge spread function (ESF) susceptibility to noise, the approach was... 

    QCT: A measuring tool dedicated to the estimation of image parameters for quality assurance/quality control programs of ct scanners

    , Article 15th IEEE International Symposium on Medical Measurements and Applications, MeMeA 2020, 1 June 2020 through 3 June 2020 ; July , 2020 Khodajou Chokami, H ; Hosseini, S. A ; Ghorbanzadeh, M ; Mohammadi, M ; IEEE; IEEE Instrumentation and Measurement Society; IEEE Sensors Council Italy Chapter; Politecnica di Bari; Politecnico di Torino; Societa Italiana di Analisi del Movimento in Clinica ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    Computed Tomography (CT) is one of the most widely used screening and diagnostic tools in medical imaging centers. Considering IAEA HUMAN HEALTH SERIES No. 19 and the American College of Radiology (ACR) Accreditation Program, quality assurance (QA) and quality control (QC) are mandatory programs to periodically monitor the system condition to promote the effective utilization of ionization radiation for a diagnostic outcome through obtaining and retaining appropriate image quality and reduction of patient dose. Computational phantoms (CPs) are the key tool to monitor system condition. The commercial QC phantoms are expensive products and are not flexible enough for user demands. In this...