Loading...
Search for: power-switch-fault
0.005 seconds

    Geometric-Based Fault Diagnosis in a Grid-Connected Inverter

    , Ph.D. Dissertation Sharif University of Technology Mashreghi, Ali (Author) ; Namvar, Mehrzad (Supervisor)
    Abstract
    Inverters are the main utility in transmitting power from distributed generation (DG) systems toward grid and their safe and immune performance has become a major concern among the system designers. In addition to poor power transmittance, faults in inverter can harm other equipment such as DG and local load. Consequently different protections has been considered to increase the reliability of these systems. Some of these protections like fuses and varistors are implemented in the hardware while others are considered in the processor. In the later class of protections, fault detection and isolation (FDI) system has been the subject of intense investigation in inverters over the past two... 

    Fast short circuit power switch fault detection in cascaded H-bridge multilevel converter

    , Article IEEE Power and Energy Society General Meeting ; 2013 ; 19449925 (ISSN); 9781479913039 (ISBN) Shahbazi, M ; Zolghadri, M. R ; Poure, P ; Saadate, S ; Sharif University of Technology
    2013
    Abstract
    Multilevel converters are being widely used in a large number of power electronics applications. Due to the increased number of switching devices, they are more likely to have faults in their switches than the conventional converters. In order to have a balanced operation after a short circuit power switch fault occurrence, it is necessary to detect the fault location. In this paper, a fast power switch fault detection method is presented to identify the fault location. This method only needs one additional voltage sensor per phase, and is faster compared to most of the existing methods. Also it is easy for implementation on a FPGA chip. The proposed method is verified by computer... 

    Fast detection of open-switch fault in cascaded H-Bridge multilevel converter

    , Article 6th Annual International Power Electronics, Drive Systems, and Technologies Conference, PEDSTC 2015, 3 February 2015 through 4 February 2015 ; February , 2015 , Pages 538-543 ; 9781479976539 (ISBN) Shahbazi, M ; Zolghadri, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    Cascaded H-Bridge converter has recently been utilized in different high-power applications due to its modular and simple structure. In order to have a balanced operation after a fault occurrence in this converter, it is necessary to detect the switch fault and its location. In this paper, a fast power switch fault detection method is presented to identify the fault and its location. Only one voltage measurement per phase is required by this method, and the fault detection is faster compared to the existing methods. Moreover, it is easy for implementation on an FPGA device, due to the use of simple math, relational and state machine blocks. The proposed method is verified by computer... 

    Fast and simple open-circuit fault detection method for interleaved DC-DC converters

    , Article 7th Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2016, 16 February 2016 through 18 February 2016 ; 2016 , Pages 440-445 ; 9781509003754 (ISBN) Shahbazi, M ; Zolghadri, M. R ; Ouni, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2016
    Abstract
    Interleaved DC-DC boost converters are interesting choices in applications like fuel cells and photovoltaic systems. Although this converter offers low current ripple, but an open-circuit switch fault can lead to unacceptable current ripples. In this paper, a very fast and simple method is proposed to detect an open-circuit switch fault and its location. This method doesn't need any additional sensors, is efficient in CCM and DCM modes of operation, and can detect the fault in less than one switching period. Moreover, this method is suitable for implementation on an FPGA, due to the use of simple math and state machine blocks. Simulations are carried out to validate the effectiveness of this... 

    Fast detection of open-switch fault in cascaded H-bridge multilevel converter

    , Article Scientia Iranica ; Volume 25, Issue 3D , 2018 , Pages 1561-1570 ; 10263098 (ISSN) Shahbazi, M ; Zolghadri, M. R ; Khodabandeh, M ; Ouni, S ; Sharif University of Technology
    Sharif University of Technology  2018
    Abstract
    Cascaded H-bridge converter has been utilized recently in different high-power applications due to its modular and simple structure. In order to have a balanced operation after a fault occurrence in this converter, it is necessary to detect the switch fault and its location. In this paper, a fast power-switch fault detection method is presented to identify a fault and its location. Only one voltage measurement per phase is required by this method, and the fault detection is faster compared to the existing methods. Moreover, it is suitable for implementation on an FPGA device due to the use of simple math, relational, and state machine blocks. The proposed method is verified by computer...