Loading...
Search for: steel-plate-shear-walls
0.011 seconds
Total 46 records

    Method of Estimating the Response Modification Factor for Stiffened Steel Shear Wall Systems

    , M.Sc. Thesis Sharif University of Technology Aslani, Jalal (Author) ; Bakhshi, Ali (Supervisor)
    Abstract
    Steel shear wall systems have been introduced as a lateral load resisting system since 1970s. Based on the designer’s choice, this system can be used with or without stiffeners. Employing stiffeners prevents the elastic buckling of steel plates which can enhance the system to absorb more energy. The design code for using stiffners has not developed yet in Iran since this kind of systems is not common practice. In this study, the Response Modification Factor (R), as an important factor in the design procedures of structures, is investigated for 2 to 10-story building structures which have steel shear walls with 3 and 6 millimeters thickness with 3, 4 and 6 meters spans.To this end, the... 

    Performance Based Optimal Seismic Design of Steel Plate Shear Walls by Bendurance Time Method

    , M.Sc. Thesis Sharif University of Technology Ghaderifard, Morteza (Author) ; Estekanchi, Homayoon (Supervisor)
    Abstract
    The AISC Seismic Design Provisions include capacity design requirements for steel plate shear walls since 2005. This system consist of thin web plates that infill frame panels with steel beams as horizontal boundary elements (HBEs), and columns as vertical boundary elements (VBEs). The thin unstiffened web plates are expected to buckle in shear at low load levels and develop tension field action, providing ductility and energy dissipation through tension yielding of the web plate. HBEs are designed for stiffness and strength requirements and are expected to anchor the tension field formation in the web plates. VBEs are designed for yielding of web plates and plastic hinge formation at the... 

    Experimental and Analytical Studies on Hysteretic Behavior of Trapezoidally Corrugated Steel Shear Walls

    , Ph.D. Dissertation Sharif University of Technology Emami, Fereshteh (Author) ; Mofid, Masoud (Supervisor) ; Vafai, Abolhassan (Co-Advisor)
    Abstract
    Steel shear wall system has been used in recent years as the lateral-load resisting system in the design and retrofit of high-rise buildings. This system consists of infill shear panel is framed by surrounding steel frames. Infill shear panel can be applied in two types: stiffened or unstiffened. Considering to the previous studies, the stiffened type is more convenient in the seismic performance and utility condition. However, in the stiffened system, the construction cost is considerably higher because of the complicated construction details. This dissertation concentrates on the experimental and analytical studies of trapezoidally corrugated steel shear walls as an option for removing the... 

    Using Finite Element Method for Analyzing the Performance of Low Yield Point Steel Plate Shear Wall

    , M.Sc. Thesis Sharif University of Technology Jebelli, Houtan (Author) ; Mofid, Massoud (Supervisor)
    Abstract
    Steel plate shear walls are lateral load resisting systems, especially against earthquake excitation. They are constructed with or without stiffeners. Stiffened walls are more ductile than without stiffeners walls. In this research, nine thin steel plate shear walls models were considered in three groups of 5story, 01story and 05 story walls. In each group different yield point steel for the infill plate was used. The results showed that, using low yield point(LYP) steel will increase energy dissipation of models up to %36. LYP also improve shear capacity of models up to %96. The results showed that using LYP will cause lower lateral displacement in models  

    Response Modification Factor of Steel Plate Shear Wall in Steel Structures

    , M.Sc. Thesis Sharif University of Technology Merati, Saeed (Author) ; Mofid, Massoud (Supervisor)
    Abstract
    Steel shear wall systems have been introduced as a lateral load resisting system since 1970s. Based on the designer’s choice, this system can be used with or without stiffeners. Employing stiffeners prevents the elastic buckling of steel plates which can enhance the system to absorb more energy. The design code for using stiffeners has not developed yet in Iran since this kind of systems is not common practice. In this study, the Response Modification Factor (R), as an important factor in the design procedures of structures, is investigated for 1,3,5,7 and 10-story regular and irregular building structures which have un-stiffened steel shear walls with 3, 4.5 and 6 millimeters thickness with... 

    Corrugated Steel Shear Walls with and Without Openings, with Regard to Different Angles of Corrugation

    , M.Sc. Thesis Sharif University of Technology Farzampour, Alireza (Author) ; Mofid, Masoud (Supervisor)
    Abstract
    The widespread usage of corrugated steel plates as girders and steel shear walls necessitates the need for further investigation of theseefficient structural members. Having significant initial stiffness, high capability of energy dissipation and special geometry are the fundamental reasons for this study. The nonlinear behavior of trapezoidal corrugated steel shear walls with rectangular opening has been studied in this thesis. A series of corrugated and simple shear walls with and without opening regarding different angles of corrugation and different infill plat thicknesses have been investigated. This analytical study was conducted to compare the initial stiffness, ultimate strength,... 

    Response Modification Factor of Steel Plate Shear Walls in Concrete Structures

    , M.Sc. Thesis Sharif University of Technology Hosseinkhani, Ali (Author) ; Mofid, Massoud (Supervisor)
    Abstract
    The Steel shear wall is one of resisting lateral load system which has been used since 1970.with respect to design we can apply this system with or without stiffeners .here our investigation is about steel shear wall without stiffeners. Also this system is called SSW. Since using this system is new fashion, there is no specific code for it in Iranian 2800 code .also there is no code for using this system in reinforced concrete frames in any code which makes this investigation much harder. Need to obtain R which is one of the most important seismic parameters, encouraged us to consider R for SSW in 3 to 7 storey structures .we obtained static pushover curves with nonlinear static analysis... 

    Analysis on Characteristics and Behavior of Steel Structures with Steel Plate Shear Walls

    , M.Sc. Thesis Sharif University of Technology Sadati, Mohammad (Author) ; Mofid, Masood (Supervisor)
    Abstract
    Steel plate shear walls (SPSWs) are popular lateral force resisting systems whose practical applications range from high seismic regions to medium and low seismic areas and wind load applications. The factors which make SPSW attractive include its energy dissipation capacity, excellent ductility, constructability, speed of construction compared to concrete shear walls, reduced architectural footprint compared to concrete shear walls, and increased inelastic deformation capacity as compared to braced frames and concrete shear walls.
    In this research, characteristics and behavior of un-stiffened perforated SPSWs using non-linear finite elements software has been investigated. In order to... 

    A Numerical Investigation on Ultimate Strength of Steel Plate Shear Walls Utilizing Various Boundary Frame Elements and Different In-fill Plate Thicknesses

    , M.Sc. Thesis Sharif University of Technology Eghbali Farkoush, Vahid (Author) ; Khalu, Alireza (Supervisor)
    Abstract
    In this thesis different steel plate shear walls have been investigated using ABAQUS software. These investigations have been focused on various topics, including both boundary frame elements and also the in-fill plate. The main results have been gathered by utilizing different steel plate thicknesses and different boundary frame elements. In order to achieve a better understanding of the effects of both of these elements, various aspect ratios have also been investigated. Moment of inertia has been noted as the main property of both beams and columns used in SPSW. Comparison of the gained results is noteworthy. They show a variety of changes in the load-displacement diagrams, due to changes... 

    Introduction OF Coupling Panels in Steel Plate Shear Walls and Optimized Design Method

    , M.Sc. Thesis Sharif University of Technology Sadeghi Eshkevari, Soheil (Author) ; Mofid, Massood (Supervisor) ; Mohtasham Dolatshahi, Kiarash (Supervisor)
    Abstract
    Coupling beams have had a widespread application as performance enhancing devices within concrete structures and more recently, also in steel structures. However, the conventional coupling beams are not so efficient in coupling distant walls. In this paper, a novel form of coupling members, namely, Coupling Panels is proposed and then, the application for a nine-storey building is investigated. Coupling panels are steel plate shear walls which are exerted in the intermediate spans between adjacent shear walls, and act as a mega coupling beam. First, a verified finite element model is constructed to demonstrate coupling panel behavior along with its global structural mechanism. Subsequently,... 

    Numerical Study of Stiffener Effects on Composite Shear Wall Performance

    , M.Sc. Thesis Sharif University of Technology Taherkhani, Amir (Author) ; Khaloo, Alireza (Supervisor)
    Abstract
    Concrete filled double-steel-plate (CFDSP) composite wall is a new lateral resisting system that recently used in design and strengthening of high-rise buildings. This CFDSP composite wall is composed of concrete filled steel tubular columns at the two boundaries and concrete filled double-steel-plate wall body. The main advantage of this system is the interaction between steel and concrete which delays local buckling of steel plates. Also, steel jacket increases the strength of concrete in result of confinement effects. Furthermore, these systems have lower thickness compared to ordinary concrete shear walls. Hence, they have less structural weight which reduces the earthquake force.... 

    Performance of RC Shear Walls Strengthened by Vertical Strips of Steel Plates under Seismic Loading

    , M.Sc. Thesis Sharif University of Technology VatanKhah Rahmani, Borna (Author) ; Khaloo, Alireza (Supervisor)
    Abstract
    Even though a considerable amount of research has been conducted on composite wall system during past years, very limited research has been reported on shear walls strengthened by steel plates. In 2008, the composite shear wall, which consisted of reinforced concrete wall, retrofitted by steel plates, attached to both sides of RC walls using mechanical connectors in form of shear studs, bolts or lateral ties tested under axial load and lateral force. In this research, seismic behavior of RC shear walls strengthened by vertical strips of steel plates is going to be studied. The result will be compared with RC shear wall which fully covered by steel plates. The behavior of RC shear wall will... 

    Performance of RC Shear Walls Strengthened by Diagonal Strips of Steel Plates under Seismic Loading

    , M.Sc. Thesis Sharif University of Technology Fayyazi, Davood (Author) ; khalo, Alireza (Supervisor)
    Abstract
    Even though a considerable amount of research has been conducted on composite wall system during past years, very limited research has been reported on shear walls strengthened by steel plates. In 2008, the composite shear wall, which consisted of reinforced concrete wall, retrofitted by steel plates, attached to both sides of RC walls using mechanical connectors in form of shear studs, bolts or lateral ties tested under axial load and lateral force. In this research, seismic behavior of RC shear walls strengthened by diagonal strips of steel plates is going to be studied. The result will be compared with RC shear wall which fully covered by steel plates.The behavior of RC shear wall will be... 

    Performance Analysis and Consideration of Steel Shear Walls and Bracing in Irregular Plans of Mid-rise and High-rise Structures

    , M.Sc. Thesis Sharif University of Technology Fathi, Morvarid (Author) ; Mofid, Masoud (Supervisor)
    Abstract
    Plan irregularities of structures due to the governing regional and environmental conditions are a pretty important issue from the architectural as well as structural design point of view. Most of the time, especially in mid-rise and/or high-rise buildings with plan irregularities, dual system of Moment Resisting Frames (MRF), accompanied with shear walls are strongly suggested. Considering the previous works and investigations of researchers, reveals not too many studies and researches in this regards; specially, when it comes into new area and application of the Steel Shear Walls (SSW). In the present work, at first it is proposed to model and analyze a MRF steel structure with plan... 

    Study on Behavior of Diagonally Stiffened Steel Plate Shear Walls

    , Ph.D. Dissertation Sharif University of Technology Akhavan Sigariyazd, Mohammad Hossein (Author) ; Joghataie, Abdolreza (Supervisor) ; Khajeh Ahmad Attari, Nader (Supervisor)
    Abstract
    In this study, the behavior of diagonally stiffened steel plate shear wall systems which have a new configuration of stiffeners is investigated. This dissertation is divided into three main sections which contain experimental studies, finite element analysis and developing design equations. In the section on experimental studies, 5 single-bay, single-story, one-third scale specimens were tested. An unstiffened specimen as a control sample and two other specimens with different configuration of stiffeners were constructed and tested to study the effect of diagonal stiffeners. Based on the observations during the tests, it was decided to add and study two other specimens too, including one... 

    Numerical Modeling of the Behavior of an Innovative Steel Shear Wall

    , M.Sc. Thesis Sharif University of Technology Valikhani, Alireza (Author) ; Khonsari, Vahid (Supervisor)
    Abstract
    The behavior of a new steel shear wall, already devised by the supervisor of this project, and tested by other students, was modeled numerically. Such numerical simulation was carried out using the Finite Element Methods of analysis. Hexagonal solid elements were employed in order to discretize the tested specimens and those parts of the test assembly which had to be included in the models. Both, Monotonic and Cyclic tests were simulated numerically. Comparison of the tests results with those of the numerical models showed fair correlation between them. Percentages of error in the dissipated energy for the three monotonic tests were 6.9%, 6.4% and 11.2%, respectively, whereas that of the... 

    A Study of Steel Frames with Steel Plate Shear Wall Resisting System Subjected to Blast Loading

    , M.Sc. Thesis Sharif University of Technology Shabanlou, Mohammad (Author) ; Aligani Moghaddam, Hassan (Supervisor) ; Saedi Darian, Amir (Co-Supervisor)
    Abstract
    Over the last years, terrorist attacks and accidental explosions have brought on a need for research in the field of structural engineering to study the response of a building subjected to blast loading conditions. An explosion within or surrounding a building, not only can have disastrous effects causing both structural damage or failure, but may also lead to the death of human beings.In order to prevent these catastrophes and gain a better understanding of responses of the buildings and lateral resisting systems with different characteristics, the study of the behavior of the lateral resisting systems under blast loading conditions is essential. This research will also aid in the... 

    Examining Steel Plate Shear Wall with Various Infill Plates Under Cyclic Loads

    , M.Sc. Thesis Sharif University of Technology Darvishi, Hadi (Author) ; Mofid, Massoud (Supervisor)
    Abstract
    In the present study, a number of Steel Plate Shear wall (SPSW) models with various infill plates such as perforated and slit infill panels are analyzed and the results are utilized to discuss about behavior of Steel Plate Shear walls with various infill plates. The ABAQUS finite element package is utilized for all Eigen value and incremental nonlinear pushover analyses. Cyclic loading is in compliance with the ATC 24 loading protocol (ATC 1992). To validate modeling, boundary conditions and loading procedures, the experimental results provided by Darren Vian et al. [102, 103] and In-Rak et al. [48, 49] was modeled and analyzed. Investigation of steel plate shear walls made of different... 

    Investigation of Steel Plate Shear Wall Behavior with Shape Memory Alloy Connection

    , M.Sc. Thesis Sharif University of Technology Haghi, Farzad (Author) ; Mofid, Masoud (Supervisor) ; Mohtasham Dolatshahi, Kiarash (Co-Advisor)
    Abstract
    In recent decades, restoring residual deformations and adding the capability of returning to initial deformed state was investigated by many researchers. Steel Plate Shear Wall (SPSW) is one of structural earthquake resisting system that have high ductility capacity and good energy absorption property. On of major issues in SPSW systems is intense nonlinear deformation in panel’s infill web plate and this panels vertical and horizontal boundary elements. By incorporating Shape Memory Alloy (SMA) connections we can add returning to first deformed condition (self-centering) and sustain high ductility capacity to many structures. In this research the addition of SMA connections to SPSW system... 

    On the Characteristics of The Behavior of Multi-story Steel Frames Accompanied by Steel Shear Walls with Openings

    , M.Sc. Thesis Sharif University of Technology Rostami, Parisa (Author) ; Mofid, Massoud (Supervisor)
    Abstract
    As steel shear walls are usually applied in the central cores of buildings (around the elevators and stairs), the use of opening as door is inevitable in steel shear wall spans. On the other hand, because of weakening the performance of steel shear walls due to the presence of these openings, it is necessary to apply stiffeners around it. The use of stiffeners around all sides of opening continued to beams and columns, is very expensive. Therefore, the necessity of studying on the effect of different arrangements of stiffeners on the behavior of steel shear walls is felt. In this research, a number of steel shear walls with different characteristics in terms of plate aspect ratio, location...