Loading...
Search for: time-domain-simulations
0.006 seconds
Total 31 records

    Design and implementation of a single phase grid-connected PV inverter with a new active damping strategy

    , Article PEDSTC 2014 - 5th Annual International Power Electronics, Drive Systems and Technologies Conference ; Feb , 2014 , pp. 72-77 Hamzeh, M ; Karimi, Y ; Asadi, E ; Oraee, H ; Sharif University of Technology
    Abstract
    This paper presents an effective current injection method for a single phase grid-connected PV inverter with LCL filter. The main objective of the proposed control strategy is to compensate the resonance effect of the LCL filter. In the proposed control strategy, a resonance compensator is augmented to the conventional proportional resonance (PR) controller to attenuate current oscillations in resonance frequency of LCL filter. The proposed strategy robustly regulates the output current of grid connected inverter in various grid impedances and provides a high quality current injection capability for the PV inverter in harmonic polluted condition of the grid voltage. The performance of the... 

    A new power management control strategy for a MV microgrid with both synchronous generator and inverter-interfaced distributed energy resources

    , Article IEEE International Symposium on Industrial Electronics ; 1- 4 June , 2014 , pp. 2529-2534 ; ISBN: 978-147992399-1 Zangeneh, M ; Hamzeh, M ; Mokhtari, H ; Karimi, H ; Sharif University of Technology
    Abstract
    Control strategies of a microgrid which includes both synchronous generators and converter-based distribution generation (DG) units must be designed such that effective operation of the microgrid is achieved. The main objective of this paper is to develop a high performance control strategy for an islanded medium voltage (MV) microgrid consisting of inverter and non-inverter interfaced DG units. A new control method for the synchronous generator in an islanded microgrid is proposed based on a virtual droop scheme. The proposed strategy can effectively manage the real and reactive powers of the microgrid among the inverter and non-inverter based DG units. The steady state and dynamic... 

    Control of a microgrid with unbalanced loads using virtual negative-sequence impedance loop

    , Article PEDSTC 2014 - 5th Annual International Power Electronics, Drive Systems and Technologies Conference ; 2014 , p. 78-83 Hamzeh, M ; Karimi, H ; Mokhtari, H ; Mahseredjian, J ; Sharif University of Technology
    Abstract
    This paper presents an effective control strategy for autonomous operation of a multi-bus medium voltage (MV) microgrid (MG) consisting of several dispatchable distributed generation (DG) units. Each electronically-coupled DG unit supplies the loads which can be unbalanced due to the inclusion of single-phase loads. The proportional resonance (PR) and droop controllers are, respectively, used to regulate the load voltage and share the average powers among the DG units. The virtual negative-sequence impedance controller (VNSIC) is proposed to effectively compensate the negative-sequence currents of the unbalanced loads. Moreover, the VNSIC minimizes the negative-sequence currents in the MV... 

    A decentralized self-adjusting control strategy for reactive power management in an islanded multi-bus MV microgrid

    , Article Canadian Journal of Electrical and Computer Engineering ; Volume 36, Issue 1 , 2013 , Pages 18-25 ; 08408688 (ISSN) Hamzeh, M ; Mokhtari, H ; Karimi, H ; Sharif University of Technology
    2013
    Abstract
    This paper presents a decentralized self-adjusting reactive power controller for the autonomous operation of a multi-bus medium voltage (MV) microgrid. The main objective of the proposed control strategy of each distributed generation (DG) unit is to compensate the reactive power of its local loads and to share the reactive power of the nonlocal loads among itself and other DG units. The proposed control strategy includes an improved droop controller whose parameters are adjusted according to the reactive power of the local loads. A virtual inductive impedance loop is augmented to the voltage controller to enhance the steady state and transient responses of the proposed reactive power... 

    A control method for integrating hybrid power source into an islanded microgrid through CHB multilevel inverter

    , Article PEDSTC 2013 - 4th Annual International Power Electronics, Drive Systems and Technologies Conference ; 2013 , Pages 495-500 ; 9781467344845 (ISBN) Ghazanfari, A ; Hamzeh, M ; Mokhtari, H ; Sharif University of Technology
    2013
    Abstract
    This paper proposes a control strategy for an islanded microgrid to effectively coordinate hybrid power source (HPS) units and to robustly control individual interfaced inverters under unbalanced and nonlinear load conditions. Cascaded H-bridge (CHB) multilevel inverters are flexibly deployed in order to enhance the power quality and redundancy. The HPS employs fuel cell (FC) as the main and supercapacitors (SC) as complementary power sources. Fast transient response; high performance; and high power density are the main characteristics of the proposed HPS system. The presented control strategy consists of a power management strategy for the HPS units and a voltage control strategy for the... 

    A new decentralized voltage control scheme of an autonomous microgrid under unbalanced and nonlinear load conditions

    , Article Proceedings of the IEEE International Conference on Industrial Technology ; February , 2013 , Pages 1812-1817 ; 9781467345699 (ISBN) Paridari, K ; Hamzeh, M ; Emamian, S ; Karimi, H ; Bakhshai, A ; Sharif University of Technology
    2013
    Abstract
    This paper presents an effective voltage control strategy for the autonomous operation of a medium voltage (MV) microgrid under nonlinear and unbalanced load conditions. The main objectives of this strategy are to effectively compensate the harmonic and negative-sequence currents of nonlinear and unbalanced loads using distributed generation (DG) units. The proposed control strategy consists of a multi-proportional resonant controller (MPRC) whose parameters are assigned with particle swarm optimization (PSO) algorithm. The optimization function is defined to minimize the tracking error at the specific harmonics considering the stability limitations. In this paper the performance of the... 

    Robust decentralized voltage control of an islanded microgrid under unbalanced and nonlinear load conditions

    , Article Proceedings of the IEEE International Conference on Industrial Technology, Cape Town, South Africa ; Feb , 2013 , Pages 1825-1830 ; 9781467345699 (ISBN) Emamian, S ; Hamzeh, M ; Paridari, K ; Karimi, H ; Bakhshai, A ; Sharif University of Technology
    2013
    Abstract
    This paper presents a new decentralized control strategy for the islanded operation of a microgrid under unknown load conditions. In the islanded mode of operation, the microgrid should provide the load with a set of regulated balanced three-phase voltages. The load which is parametrically and topologically uncertain can also be unbalanced and/or nonlinear. Thus, the use of conventional control strategies results in the poor performance and even instability of the microgrid system. The proposed method assumes that the load current is a measurable disturbance signal. The robust optimal control approaches are used to design a controller to overcome the disturbances resulting from the unknown... 

    Active power management of multihybrid fuel cell/supercapacitor power conversion system in a medium voltage microgrid

    , Article IEEE Transactions on Smart Grid ; Volume 3, Issue 4 , 2012 , Pages 1903-1910 ; 19493053 (ISSN) Ghazanfari, A ; Hamzeh, M ; Mokhtari, H ; Karimi, H ; Sharif University of Technology
    2012
    Abstract
    This paper proposes a hierarchical active power management strategy for a medium voltage (MV) islanded microgrid including a multihybrid power conversion system (MHPCS). To guarantee excellent power management, a modular power conversion system is realized by parallel connection of small MHPCS units. The hybrid system includes fuel cells (FC) as main and supercapacitors (SC) as complementary power sources. The SC energy storage compensates the slow transient response of the FC stack and supports the FC to meet the grid power demand. The proposed control strategy of the MHPCS comprises three control loops; dc-link voltage controller, power management controller, and load current sharing... 

    Dynamic modeling of a wind turbine with brushless doubly fed induction generator

    , Article 2012 3rd Power Electronics and Drive Systems Technology, PEDSTC 2012, 15 February 2012 through 16 February 2012 ; February , 2012 , Pages 490-494 ; 9781467301114 (ISBN) Tohidi, S ; Zolghadri, M. R ; Oraee, H ; Oraee, A ; Sharif University of Technology
    2012
    Abstract
    Brushless Doubly Fed Induction Generator (BDFIG) has been recently proposed to be used in variable speed wind turbines. This paper intends to investigate the influence of certain model simplifications to obtain a reduced-order model of a wind turbine with BDFIG suitable for transient studies. To achieve this goal, small signal analysis is performed for a recently manufactured 250 kVA BDFIG to obtain system modes and their participation factors. Identifying highly damped modes, influences of neglecting dynamics of their participated states are studied through time-domain simulation in MATLAB/Simulink  

    A new control strategy for a multi-bus MV microgrid under unbalanced conditions

    , Article IEEE Transactions on Power Systems ; Volume 27, Issue 4 , 2012 , Pages 2225-2232 ; 08858950 (ISSN) Hamzeh, M ; Karimi, H ; Mokhtari, H ; Sharif University of Technology
    2012
    Abstract
    This paper proposes a new control strategy for the islanded operation of a multi-bus medium voltage (MV) microgrid. The microgrid consists of several dispatchable electronically-coupled distributed generation (DG) units. Each DG unit supplies a local load which can be unbalanced due to the inclusion of single-phase loads. The proposed control strategy of each DG comprises a proportional resonance (PR) controller with an adjustable resonance frequency, a droop control strategy, and a negative-sequence impedance controller (NSIC). The PR and droop controllers are, respectively, used to regulate the load voltage and share the average power components among the DG units. The NSIC is used to... 

    Modeling and control of a grid-connected BDFM under unbalanced grid voltage conditions

    , Article 2011 IEEE International Electric Machines and Drives Conference, IEMDC 2011, 15 May 2011 through 18 May 2011 ; May , 2011 , Pages 1647-1651 ; 9781457700613 (ISBN) Sotoodeh, P ; Seyed Mahdi Izadkhast ; Khosravi, H ; Oraee, H ; Sharif University of Technology
    2011
    Abstract
    This paper presents a mathematical model for Brushless Doubly-Fed Machine (BDFM) based on Stator Flux Orientation (SFO) in positive and negative reference frames under unbalanced grid voltage conditions. A negative controller is designed to eliminate the effects of unbalanced conditions on electrical torque. The model and controller performance during unbalanced conditions is validated by time domain simulation in MATLAB/Simulink  

    Influence of different series dynamic resistors on low-voltage ride-through of brushless doubly fed induction generator

    , Article Electric Power Components and Systems ; Volume 43, Issue 8-10 , 2015 , Pages 995-1005 ; 15325008 (ISSN) Tohidi, S ; Oraee, H ; Zolghadri, M. R ; Tavner, P. J ; Sharif University of Technology
    Taylor and Francis Inc  2015
    Abstract
    The brushless doubly fed induction generator has been proposed for use in wind turbines as a more reliable alternative to the more commonly used doubly fed induction generator. To realize the commercial promises of the brushless doubly fed induction generator in this role, it must meet the existing grid connection codes, particularly with respect to low-voltage ride-through. In this article, the application of series dynamic resistors is proposed to enhance brushless doubly fed induction generator low-voltage ride-through capability, and the required analysis is provided. Three locations for series dynamic resistors are suggested in the brushless doubly fed induction generator circuit and... 

    Efficient control scheme of wind turbines with doubly fed induction generators for low-voltage ride-through capability enhancement

    , Article IET Renewable Power Generation ; Volume 4, Issue 3 , May , 2010 , Pages 242-252 ; 17521416 (ISSN) Rahimi, M ; Parniani, M ; Sharif University of Technology
    2010
    Abstract
    As the penetration of wind power in electrical power systems increases, it is required that wind turbines remain connected to the grid and actively contribute to the system stability during and after grid faults. This study proposes an efficient control strategy to improve the low-voltage ride-through (LVRT) capability in doubly fed induction generators (DFIGs). The proposed scheme consists of passive and active LVRT compensators. The passive compensator is based on a new crowbar arrangement located in series with stator windings. It considerably reduces the rotor inrush current at the instants of occurring and clearing the fault. The active LVRT compensator is realised through rotor voltage... 

    Time-domain split-step method with variable step-sizes in vectorial pulse propagation by using digital filters

    , Article Optics Communications ; Volume 283, Issue 12 , June , 2010 , Pages 2518-2524 ; 00304018 (ISSN) Farhoudi, R ; Mehrany, K ; Sharif University of Technology
    2010
    Abstract
    Finite impulse response (FIR) and infinite impulse response (IIR) digital filters are proposed to allow for time-domain simulation of optical pulse propagation by using the operator-splitting technique. These filters simulate polarization mode dispersion and chromatic dispersion effects with acceptable accuracy in time-domain. An analytical relation between the coefficients of these filters and the simulation step-size is established to accommodate the possibility of carrying out the time-domain split-step method with variable split-step length at virtually no computational burden. The superiority of the proposed method over the conventional frequency-domain technique is particularly... 

    A simple time domain approach to noise analysis of switched capacitor circuits

    , Article IEICE Electronics Express ; Volume 7, Issue 11 , Jun , 2010 , Pages 745-750 ; 13492543 (ISSN) Rashtian, M ; Hashemipour, O ; Afshin Hemmatyar, A. M ; Sharif University of Technology
    2010
    Abstract
    Thermal noise is one of the most important limiting factors on the performance of switched-capacitor (SC) circuit due to the aliasing effect of wide-band thermal noise. In this paper a new simple method for estimating the effect of thermal noise is presented. In the proposed technique only the discrete sampled noise is considered. HSPICE simulator and analytical analysis are used to estimate the sampled noise specification on each clock state. Next, using difference equations of the circuit, time domain simulation is done by MATLAB. Based on this method, a SC integrator is analyzed and results compared to the measured noise response  

    Dynamic behavior analysis of doubly-fed induction generator wind turbines - The influence of rotor and speed controller parameters

    , Article International Journal of Electrical Power and Energy Systems ; Volume 32, Issue 5 , June , 2010 , Pages 464-477 ; 01420615 (ISSN) Rahimi, M ; Parniani, M ; Sharif University of Technology
    2010
    Abstract
    This paper analytically investigates the effects of system and controller parameters and operating conditions on the dynamic and transient behavior of wind turbines (WTs) with doubly-fed induction generators (DFIGs) under voltage dips and wind speed fluctuations. Also, it deals with the design considerations regarding rotor and speed controllers. The poorly damped electrical and mechanical modes of the system are identified, and the effects of system parameters, and speed/rotor controllers on these modes are investigated by modal and sensitivity analyses. The results of theoretical studies are verified by time domain simulations. It is found that the dynamic behavior of the DFIG-based WT... 

    Adaptive delay compensator for the robust Wide-Area damping controller design

    , Article IEEE Transactions on Power Systems ; Volume 31, Issue 6 , 2016 , Pages 4966-4976 ; 08858950 (ISSN) Beiraghi, M ; Ranjbar, A. M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc 
    Abstract
    This paper presents an adaptive delay compensator (ADC) on the basis of the latest development in wide-area measurement system (WAMS) to cater to varying latencies. The proposed compensator can effectively reciprocate the phase deviation resulting from varying delays to improve the performance of central wide-area damping controller (WADC). The greatest challenge to continuous delay compensation is the uncertainty regarding the inherent robustness of the central controller. The proposed technique provides an opportunity to epitomize the uncertainty retrieved from phase compensated delay. Next, taking the uncertainty into consideration, the mixed H2H∞ synthesis technique is adopted for the... 

    Automatic droop control for a low voltage DC microgrid

    , Article IET Generation, Transmission and Distribution ; Volume 10, Issue 1 , 2016 , Pages 41-47 ; 17518687 (ISSN) Khorsandi, A ; Ashourloo, M ; Mokhtari, H ; Iravani, R ; Sharif University of Technology
    Institution of Engineering and Technology 
    Abstract
    A DC microgrid (DC-MG) provides an effective mean to integrate various sources, energy storage units and loads at a common dc-side. The droop-based, in the context of a decentralised control, has been widely used for the control of the DC-MG. However, the conventional droop control cannot achieve both accurate current sharing and desired voltage regulation. This study proposes a new adaptive control method for DC-MG applications which satisfies both accurate current sharing and acceptable voltage regulation depending on the loading condition. At light load conditions where the output currents of the DG units are well below the maximum limits, the accuracy of the current sharing process is... 

    Modification of DFIG's active power control loop for speed control enhancement and inertial frequency response

    , Article IEEE Transactions on Sustainable Energy ; Volume 8, Issue 4 , 2017 , Pages 1772-1782 ; 19493029 (ISSN) Ashouri Zadeh, A ; Toulabi, M ; Bahrami, S ; Ranjbar, A. M ; Sharif University of Technology
    Abstract
    This paper proposes a fuzzy-based speed controller for the doubly fed induction generator (DFIG)-based wind turbines with the rotor speed and wind speed inputs. The controller parameters are optimized using the particle swarm optimization algorithm. To accelerate tracking the maximum power point trajectory, the conventional controller is augmented with a feed-forward compensator, which uses the wind speed input and includes a high-pass filter. The proposed combined speed controller is robust against wind measurement errors and as the accuracy of anemometers increases the speed regulation tends toward the ideal controller. The cutoff frequency of the applied filter is determined considering a... 

    Robust tuning of transient droop gains based on kharitonov's stability theorem in droopcontrolled microgrids

    , Article IET Generation, Transmission and Distribution ; Volume 12, Issue 14 , 2018 , Pages 3495-3501 ; 17518687 (ISSN) Mahdian Dehkordi, N ; Sadati, N ; Hamzeh, M ; Sharif University of Technology
    Abstract
    This study addresses the robust stability analysis for an islanded microgrid with droop-controlled inverter-based distributed generators (DGs). Owing to large load changes, microgrid structure reconfiguration, and higher-power demands, the low-frequency (LF) dominant modes of a microgrid stir toward unstable zone and make the system more oscillatory or even unstable. In this study, a robust two-degree-of-freedom (2DOF) decentralised droop controller, which is the combination of the conventional droop with a robust transient droop function, is utilised for each inverter-based DG unit. Unlike conventional tuning of 2DOF droop controllers, a new design procedure is proposed to robustly...