Loading...
Search for: total-harmonic-distortions
0.008 seconds
Total 30 records

    Developing a Control Algorithm for the new Power Quality Device (HPFC)

    , M.Sc. Thesis Sharif University of Technology Rezaei Zavieh, Ali (Author) ; Mokhtari, Hossein (Supervisor)
    Abstract
    Non-linear loads have been increasing in industries resulting in high levels of harmonics in power networks. Harmonics have several negative effects including higher energy losses and lifespan reduction in equipment due to thermal loss. To reduce the levels of harmonics and consequently reduce the losses in power networks different methods of harmonic suppression have been employed. These methods are normally used at the customer’s side. In all of these methods, the idea is to prevent harmonics from flowing into a power network at the Point of Common Coupling (PCC). This research tries to reduce the harmonic losses by controlling the harmonic flow in a power network. Therefore, the solution... 

    Optimal Placement of Active Filters in a Power System

    , M.Sc. Thesis Sharif University of Technology Ghasemian, Majid (Author) ; Mokhtari, Hossein (Supervisor)
    Abstract
    The extensive use of nonlinear loads such as motor drives and new generation of home appliances has caused a deterioration of power quality in power systems. The use of active power filters due to the fast variation of the loads has been recommended by power engineering. In this method, the harmonic profiles are controlled by applying active filters in a distribution feeder. Optimal placement of active filters in a distribution system due to the increase of harmonic generation loads has attracted researchers. However placement of each filter is the major concern that researchers face. In this paper, a new objective function is introduced to determine the optimal number and location of active... 

    Reducing Harmonic Distortion in Three-phase Parallel UPS Configuration with Nonlinear Load Using Disturbance Observer

    , M.Sc. Thesis Sharif University of Technology Valizade Alavi, Shahab (Author) ; Tahami, Farzad (Supervisor)
    Abstract
    Three-phase inverters as a UPS are very common in industry and non-linear loads such as rectifiers are growing in industry. Three phase inverter with non-linear load can lead to highly distorted output voltage which can make problem for sensitive loads such as servers etc. Parallel configuration of three-phase inverters, also have the same problem with non-linear loads. Droop control and Master/slave control methods are two major methods which investigated in this thesis. This paper proposes a method for reducing voltage THD in three phase inverters with non-linear load. The proposed method considers the load current as a disturbance and provide a control strategy to reject it using the... 

    Control of Three-phase UPS with Nonlinear Load Using Disturbance Observer Considering Transformer Concerns

    , M.Sc. Thesis Sharif University of Technology Shahriari, Zohair (Author) ; Tahami, Farzad (Supervisor)
    Abstract
    Nowadays, non-linear loads comprise an important part of electrical grids. One of the most essential sources of nonlinear loads is switching power supplies, which mainly include power electronic rectifiers. When power outage occurs, Uninterruptible Power Supplies (UPS) must be able to supply these loads. The nonlinearity of the load has a significant effect on the Total Harmonic Distortion (THD) of the output voltage, which may not be easily reduced, especially in three-phase inverters. Furthermore, the presence of isolating transformers in these power supplies limits the control of harmonics and intensifies the nonlinear effects of the system.In this Master Thesis, a disturbance observer is... 

    Improvement of Z-source and Quasi-z Source Inverter for Photovoltaic Applications

    , M.Sc. Thesis Sharif University of Technology Aseyedali, Mahdi (Author) ; Parniani, Mostafa (Supervisor)
    Abstract
    The Z-source and quasi-Z source inverter have a capability to increase and decrease the output voltage without using extra switching stages or transformer. Therefor these inverters are an excellent choice for applications such as photovoltaic sources because of their higher efficiency, higher reliability and lower volume and cost. One drawback of these inverters is the leakage current that causes undesirable effect on the power system and safety issues. In this research we are going to develop a new modulation method for these inverters to reject the leakage current. In this method the harmonic content of common mode voltage is concentrated on the switching frequency and its harmonics while... 

    High Efficiency, Low Distortion Boundary Conduction Mode Boost PFCs for Different Power Ranges

    , Ph.D. Dissertation Sharif University of Technology Marvi, Mohammad (Author) ; Fotowat-Ahmadi, Ali (Supervisor)
    Abstract
    In this thesis, new boundary conduction mode boost PFCs are proposed and implemented for different power levels according to the characteristics and requirements of each power level. For medium power applications, we have proposed a new zero voltage switching PFC based on a synchronous boost converter which is controllable with conventional boundary conduction mode PFC control ICs without requiring any additional timing adjustment control circuits other than a special high side driver that consists of only low voltage components. Based on mathematical calculations, we have proposed two sipmle circuit solutions to reduce the high level of line current zero crossing distortion in the proposed... 

    Design and optimization of a large-scale permanent magnet synchronous generator

    , Article Scientia Iranica ; Volume 29, Issue 1 D , 2022 , Pages 217-229 ; 10263098 (ISSN) Alemi-Rostami, M ; Rezazadeh, G ; Alipour Sarabi, R ; Tahami, F ; Sharif University of Technology
    Sharif University of Technology  2022
    Abstract
    Direct-drive permanent magnet synchronous generators enjoy numerous advantages including improved reliability, low maintenance, long life, and developed performance characteristics. In recent years, many researchers have worked on these generators to enhance their performance, especially for the wind turbine application. The focus of this paper is on the development of a step-by-step method for the design of a permanent magnet synchronous generator. Then, the winding function method is used to model the generator and calculate its output characteristics analytically. The analytical results of the designed generator are validated using Finite Element Analysis (FEA) and it is demonstrated that... 

    Reducing output voltage THD of a three-phase inverter with non-linear load using disturbance observer

    , Article 8th Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2017, 14 February 2017 through 16 February 2017 ; 2017 , Pages 431-436 ; 9781509057665 (ISBN) Valizade Alavi, S ; Tahami, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    Non-linear loads such as rectifiers are growing in industry. Three phase inverter with non-linear load can lead to highly distorted output voltage. This paper proposes a method for reducing voltage THD in three phase inverters with non-linear load. The proposed method considers the load current as a disturbance and provide a control strategy to reject it using the disturbance observer method. This method doesn't need any additional sensors or hardware and is implemented digitally in controller. Simulation results show that the presented method will reduce the total harmonic distortion of the output voltage. © 2017 IEEE  

    A fast and cost-effective control of a three-phase stand-alone inverter

    , Article 8th Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2017, 14 February 2017 through 16 February 2017 ; 2017 , Pages 67-72 ; 9781509057665 (ISBN) Mazloum, N ; Keikha, O ; Yaghoubi, M ; Tahami, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2017
    Abstract
    This paper proposes a straightforward control method for voltage control of a three-phase transformer-based inverter in uninterruptible power supplies or distributed generation systems. The approach offers a dual-loop design consisting inner current control loop and outer voltage loop. Sliding mode current controller provides desired bandwidth for voltage controller which consists of a state feedback term for stabilization and resonant term for harmonic damping. The proposed scheme provides fast dynamic response and low total harmonic distortion even for high power inverters with the limitations of switching frequency and LC filter components. Experimental studies for 2KVA linear and... 

    Comparison of common-mode voltage in three-phase quasi-Z-source inverters using different shoot-through implementation methods

    , Article Proceedings - 2018 IEEE 12th International Conference on Compatibility, Power Electronics and Power Engineering, CPE-POWERENG 2018 ; 4 June , 2018 , Pages 1-6 ; 9781538625088 (ISBN) Noroozi, N ; Zolghadri, M. R ; Yaghoubi, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    In Z-source family inverters, shoot-through (ST) states are applied as a part of passive state in each switching cycle. The distribution of ST intervals along a switching period affects the system parameters as total harmonic distortion (THD), switching loss and common-mode voltage (CMV). In this paper, ST methods in a three-phase quasi-Z-source inverter (q-ZSI) are compared due to the CMV level. High-frequency harmonics of CMV cause leakage current flow in a transformerless grid-connected photovoltaic (PV) system. Through the comparison of the ST methods, the method with minimum CMV is identified. The experimental results are Prasented for a low voltage q-ZSI prototype. © 2018 IEEE  

    Challenges of finite element analysis of re-solvers

    , Article IEEE Transactions on Energy Conversion ; 2018 ; 08858969 (ISSN) Saneie, H ; Alipour Sarabi, R ; Nasiri Gheidari, Z ; Tootoonchian, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    Nowadays position sensors are increasingly used in many applications. One of the most commonly used sensors are resolvers. There are different types of resolvers including Wound Rotor (WR) resolvers, Variable Air-gap Length Variable Reluctance (VAGL-VR) resolvers, and Sinusoidal Rotor Variable Reluctance (SR-VR) resolvers. Regardless of the resolvers’ configurations, including linear, cylindrical and disk type, finite element analysis (FEA) is inseparable part of design and performance evaluation of these magnetic sensors. The scope of this study is to discuss challenges in the FEA of resolvers. The influence of mesh quality, time steps, stop time, excitation methods including volt-age... 

    Optimal distribution network reconfiguration considering power quality issues

    , Article 2017 IEEE Smart Grid Conference, SGC 2017, 20 December 2017 through 21 December 2017 ; Volume 2018-January , March , 2018 , Pages 1-6 ; 9781538642795 (ISBN) Nazerian, E ; Gharebaghi, S ; Safdarian, A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    Distribution network reconfiguration as a technique for reducing network losses and enhancing voltage profile has attracted attention of many researchers. In spite of impacts network reconfiguration can have on power quality indices, the potentials have not been studied enough. To fill the gap, this paper presents a method to determine optimum network configuration considering voltage profile, network losses, and total harmonic distortion (THD). The proposed method also vouches for radial structure of the network, supplying all loads, and maintaining voltages and currents within allowable bounds. Since network reconfiguration problem is a combinatorial optimization problem, a meta-heuristic... 

    Challenges of Finite Element Analysis of Resolvers

    , Article IEEE Transactions on Energy Conversion ; Volume 34, Issue 2 , 2019 , Pages 973-983 ; 08858969 (ISSN) Saneie, H ; Alipour Sarabi, R ; Nasiri Gheidari, Z ; Tootoonchian, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Nowadays, position sensors are increasingly used in many applications. One of the most commonly used sensors are resolvers. There are different types of resolvers including wound rotor resolvers, variable air-gap length variable reluctance resolvers, and sinusoidal rotor variable reluctance resolvers. Regardless of the resolvers' configurations, including linear, cylindrical and disk type, finite element analysis (FEA) is inseparable part of design and the performance evaluation of these magnetic sensors. The scope of this study is to discuss challenges in the FEA of resolvers. The influence of mesh quality, time steps, stop time, excitation methods including voltage source and current... 

    Design optimization of a double-stage resolver

    , Article IEEE Transactions on Vehicular Technology ; Volume 68, Issue 6 , 2019 , Pages 5407-5415 ; 00189545 (ISSN) Alemi-Rostami, M ; Alipour Sarabi, R ; Rezazadeh, G ; Nasiri Gheidari, Z ; Oraee, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Accurate position estimation is an integral part of any motion control system. Besides, instantaneous position of poles plays an important role in electronic drive system of modern PM machines. Resolvers, due to their structure, are the most reliable position sensors in harsh environments. However, resolvers are not as accurate as optical encoders in normal conditions. To increase the accuracy of these sensors, various solutions are used, such as optimization in winding arrangement, rotor and stator contour, slot-pole combinations, and improvements in resolver-to-digital converter. In this paper, fractional slot concentrated winding is used in an axial flux resolver. By the aid of winding... 

    Improved winding proposal for wound rotor resolver using genetic algorithm and winding function approach

    , Article IEEE Transactions on Industrial Electronics ; Volume 66, Issue 2 , 2019 , Pages 1325-1334 ; 02780046 (ISSN) Alipour Sarabi, R ; Nasiri Gheidari, Z ; Tootoonchian, F ; Oraee, H ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Among position sensors, resolvers are superior from reliability point of view. However, obtaining lower output voltage harmonics and simple manufacturing process is a challenge in the design and optimization of resolvers. In this paper, a metaheuristic optimization algorithm is used to minimize total harmonic distortion of the output signals, and consequently the estimated position error in concentrated coil wound field resolvers. Meanwhile, to minimize total coil numbers, manufacturing costs, and complexity of the winding process, modified objective function and constraints are proposed. In this way, a modified winding function method is employed for performance analysis of the axial flux... 

    Simple voltage balancing approach for CHB multilevel inverter considering low harmonic content based on a hybrid optimal modulation strategy

    , Article IEEE Transactions on Power Delivery ; Volume 27, Issue 4 , July , 2012 , Pages 2150-2158 ; 08858977 (ISSN) Ghazanfari, A ; Mokhtari, H ; Firouzi, M ; Sharif University of Technology
    IEEE  2012
    Abstract
    This paper presents an effective hybrid optimal modulation technique for a cascaded H-bridge (CHB) multilevel inverter. The introduced method is generalized optimal pulsewidth modulation, which can be extended to any m-level CHB multilevel inverter operating at any switching frequency. The presented hybrid optimal modulation strategy includes the pattern exchange and optimal modulation techniques. In the optimal modulation technique, the hybrid interior-point algorithm, which is more flexible and efficient than conventional optimization techniques, is applied. The proposed hybrid optimal modulation strategy yields balanced units' output fundamental voltages, and low total harmonic distortion... 

    A configurable high frequency Gm-C filter using a novel linearized Gm

    , Article AEU - International Journal of Electronics and Communications ; Volume 109 , 2019 , Pages 55-66 ; 14348411 (ISSN) Karami, P ; Atarodi, S. M ; Sharif University of Technology
    Elsevier GmbH  2019
    Abstract
    A large-signal linearization method for operational transconductance amplifiers (OTA) using a combination of cross-coupled quadratic cell and a novel non-linear current injection technique is presented in this paper. Post-layout simulations show that for 180 nm CMOS process with a 1.8 V power supply, total harmonic distortion (THD) at 1.5 V peak-to-peak and 5 kHz input is less than −46 dB. Also, the dynamic range (DR) at given THD is 68 dB with power consumption of 0.64 mW. To verify the performance, the proposed OTA is used to design a new configurable filter in high-frequency range using N-path filter methodology. Universal Butterworth Gm-C active filters are embedded in the proposed... 

    Stable operation of grid connected Cascaded H-Bridge inverter under unbalanced insolation conditions

    , Article 2013 3rd International Conference on Electric Power and Energy Conversion Systems, EPECS 2013 2013 ; 2013 ; 9781479906888 (ISBN) Eskandari, A ; Javadian, V ; Iman Eini, H ; Yadollahi, M ; Sharif University of Technology
    2013
    Abstract
    This paper presents a single-phase Cascaded H-Bridge (CHB) inverter for photovoltaic applications. The proposed control strategy permits the optimum control of each string of PV panels in different insolation conditions. Based on the presented mathematical analysis, an analytic constraint is derived to check the stable operation of the inverter. A modified MPPT control strategy is also proposed based on this new condition. This strategy enhances the stability margins of the system by changing the operating point of some PV arrays. In this approach, the extracted power from high power cell is reduced to prevent instability issue and to avoid injection of highly distorted current into the... 

    A novel control technique for Power Factor Correction in SEPIC converter utilizing input/output voltage waveforms sampling

    , Article PECon 2012 - 2012 IEEE International Conference on Power and Energy ; 2012 , Pages 268-273 ; 9781467350198 (ISBN) Keipour, A ; Sudi, Z ; Mohagheghi, E ; Lakmehsari, A. H ; Hajihosseinlu, A ; Sharif University of Technology
    2012
    Abstract
    In this study, a simple and novel control technique for Power Factor Correction (PFC) is introduced, which is a SEPIC-based (Single-ended Primary-inductor Converter based) rectifier with high input power factor. Operation of the proposed method is based on sampling of input and output voltages in SEPIC rectifier. Using samples of input and output voltage, this control system makes the input current to follow a sinusoidal path. As a result, the line current?'s Total Harmonic Distortion (THD) is reduced and the input power factor is improved. This paper also compares the new method with the conventional control method for the power factor correction. In order to examine the proposed control... 

    Output voltage quality intensification of diode clamped multilevel inverters using FM PWM technique

    , Article 2012 3rd Power Electronics and Drive Systems Technology, PEDSTC 2012, 15 February 2012 through 16 February 2012 ; February , 2012 , Pages 98-102 ; 9781467301114 (ISBN) Najmi, V ; Ebrahimi, S ; Oraee, H ; Sharif University of Technology
    2012
    Abstract
    Improvement in switching techniques is one of the effective methods for increasing the voltage quality in Multilevel Inverters. In this paper, a novel switching technique using frequency modulation is proposed to achieve high quality output voltage of multilevel inverters. This method is employed to different configurations of multilevel inverters consist of Diode Clamped (or Neutral Point Clamped), Flying Capacitor and Cascaded H-bridge. Each multilevel inverter which utilizes this technique is modeled and simulated to investigate the performance of this method by the help of MATLAB/Simulink software. The Results show that this innovative method considerably reduces total harmonic...