    Details study of ambient wind effect on heat dissipation capacity of thermal-powerplant dry cooling-towers

    , Article American Society of Mechanical Engineers, Fluids Engineering Division (Publication) FEDSM ; Volume 1A , August 3–7 , 2014 , pp. V01AT03A017 ; ISSN: 08888116 ; ISBN: 9780791846216 Darbandi, M ; Behrouzifar, A ; Mirhashemi, A ; Salemkar, H ; Schneider, G. E ; Sharif University of Technology
    Abstract
    Thermal powerplants report a reduction in their dry cooling tower performances due to surrounding wind drafts. Therefore, it is very important to consider the influence of wind velocity in cooling tower design; especially in geographical points with high wind conditions. In this regard, we use the computational fluid dynamics (CFD) tool and simulate a dry cooling tower in different wind velocities of 0, 5 and 10 m/s. To extend our calculations; we also consider the temperature variation of circulating water through the tower heat exchanger or deltas one-by-one. We show that some heat exchangers around the tower cannot reduce the circulating water temperature sufficiently. This causes an... 

    CFD simulation of natural draught cooling tower wind-covering

    , Article Applied Mechanics and Materials, Dubai ; Volume 307 , 2013 , Pages 279-284 ; 16609336 (ISSN) ; 9783037856598 (ISBN) Darbandi, M ; Salemkar, H ; Behrouzifar, A ; Abrar, B ; Sharif University of Technology
    2013
    Abstract
    Past experiences have shown that a local wind can considerably affect the performances of powerplant cooling towers and factory chimneys. In thermal powerplants, the performance of Rankin cycles would reduce if the temperature of its condenser increases. This issue is very important to powerplants located in countries with strong local winds. To remedy the malperformance of a natural cooling tower in windy conditions, it is required to understand the physics of flow around cooling towers more clearly. One adverse physics is known as the wind covering problem which can drastically affect the natural draught through a cooling tower in windy conditions. In this paper, we focus on wind-covering... 

    Energy consumption criteria and labeling program of wet cooling towers in Iran

    , Article Energy and Buildings ; Volume 43, Issue 10 , October , 2011 , Pages 2712-2717 ; 03787788 (ISSN) Saidi, M. H ; Sajadi, B ; Sayyadi, P ; Sharif University of Technology
    2011
    Abstract
    Increasing concerns about the lack of energy resources, global warming and environmental pollution have pushed the relevant organizations to develop energy saving strategies such as energy labeling programs. In this research, a new energy labeling program is developed and evaluated for the wet cooling towers in Iran. The cooling tower parameters, including its cooling capacity and the fan power consumption, are measured using an experimental setup. The experimental data are standardized to compensate the effect of the ambient wet bulb temperature on the cooling tower performance which cannot be controlled during the experiments. The results show that the cooling tower capacity and the fan... 

    Application of a new gibbs energy equation to model a distillation tower for production of pure ethanol

    , Article Chemical Engineering and Technology ; Volume 34, Issue 10 , 2011 , Pages 1715-1722 ; 09307516 (ISSN) Hashemi, N ; Pazuki, G ; Vossoughi, M ; Hemmati, S ; Saboohi, Y ; Sharif University of Technology
    Abstract
    A steady-state equilibrium-stage model based on MESH equations was proposed to simulate saline extractive distillation columns. The interaction parameters between each component of water-CaCl 2 and ethanol-water were obtained from mean ionic activity coefficients and vapor-liquid equilibrium (VLE) experimental data. Additionally, the interaction coefficients for the ethanol-CaCl 2 pair were fitted to experimental VLE data which were reported by Nishi for the ethanol-water-CaCl 2 system. It should be noted that adjustable parameters between each pair were considered to be temperature dependent. The results confirmed that the proposed model could accurately predict the experimental... 

    Design of Airport Control Tower Structures Located in Seismic Zones

    , M.Sc. Thesis Sharif University of Technology Hakimi Toroghi, Amir (Author) ; Khaloo, Alireza (Supervisor)
    Abstract
    Airport Traffic Control Towers (ATCTs) are among the most critical structures in an airport that are expected to keep their level of serviceability after severe strong earthquakes. Therefore analysis and design of these structures need a detailed investigation on the seismic behavior of the structure based on the structural characteristics. In this study three different existing reinforced concrete ATCTs have been investigated. As important parameters of earthquake design of structures, response modification factor (R-factor) of these towers will be determined. R-factor reduces elastic force level to design force level and contains the effect of ductility, overstrength. In Iranian seismic... 

    The Study of Wind Aerodynamics Effects on Degrading the Dry Cooling Tower Performance; Using Experimental and CFD Tools

    , M.Sc. Thesis Sharif University of Technology Bagheri, Amir Hossein (Author) ; Darbandi, Massoud (Supervisor)
    Abstract
    A power plant cooling tower is like a tower, which needs to be studied very carefully from the aerodynamics point of view. Both the aerodynamics forces on the plume and intake stram are affected by the local winds and the performance of cooling tower decreases. There is a symmetric turbulent flow through the cooling tower if there is no. Wind blowing creates different vorticies, which appear in the lower section of the tower. Their periodic and wuick movments causes deficiency in towers performance and efficiency. Additionally there is wind effect on the plane of cooling tower and this causes a chocked plume which is named Wind Cover. The objective of this study is to decrease the adverse... 

    Application of Endurance Time Method in Seismic Analysis of RC Cooling Towers

    , M.Sc. Thesis Sharif University of Technology Tavazo, Hassanali (Author) ; Esmaeil Pourestekanchi, Homayoon (Supervisor)
    Abstract
    In the earthquake conditions, the collapse of cooling towers can stop power station activities and heavy financial losses that can be led increasing disaster dimentions finally. In this thesis for analysis of concrete hyperbolic cooling towers and generally for analysis of shell structures, the endurance time (ET) method benefits are used. Also with comparision between ET and standard time history method (THA), accuracy and probable errors of ET method are discussed. It should be noted that ET method is a new time history based method of seismic analysis expect that in this method, structure is imposed under specific intensifying acceleration functions. ET method is capabable for nonlinear... 

    Analysis of dehumidification effects on cooling capacity of an evaporative cooler

    , Article Journal of Thermal Science and Technology ; Volume 5, Issue 1 , 2010 , Pages 151-164 ; 18805566 (ISSN) Saidi, M. H ; Aghanajafi, C ; Mohammadian, M ; Sharif University of Technology
    2010
    Abstract
    In this study, effect of desiccant wheel, heat exchanger and cooling coil will be evaluated on decreasing the wet bulb temperature of entering air to cooling tower and decreasing the outlet cold water temperature. For this purpose, change effect of desiccant wheel parameters will be investigated on wet bulb temperature of outlet air from heat exchanger. After that, optimum parameters and minimum wet bulb temperature will be selected. Then, outlet cold water temperature will be achieved for various cooling coil surface temperature with definition of by pass factor and also by using optimum desiccant wheel parameters and entrance air wet bulb temperature to tower related to cooling coil... 

    Application of ozone treatment and pinch technology in cooling water systems design for water and energy conservation

    , Article International Journal of Energy Research ; Volume 34, Issue 6 , 2010 , Pages 494-506 ; 0363907X (ISSN) Ataei, A ; Gharaie, M ; Parand, R ; Panjeshahi, E ; Sharif University of Technology
    2010
    Abstract
    Re-circulating cooling water systems offer the means to remove heat from a wide variety of industrial processes that generate excess heat. Such systems consist of a cooling tower and a heat-exchanger network that conventionally has a parallel configuration. However, reuse of water between different cooling duties allows cooling water networks to be designed in a series arrangement. This results in performance improvement and increased cooling tower capacity. In addition, by the integration of ozone treatment into the cooling tower, the cycle of concentration can be increased. The ozone treatment also dramatically reduces the blow-down that, in turn, is environmentally constructive. In this... 

    A novel approach for energy and water conservation in wet cooling towers by using MWNTs and nanoporous graphene nanofluids

    , Article Energy Conversion and Management ; Volume 109 , 2016 , Pages 10-18 ; 01968904 (ISSN) Askari, S ; Lotfi, R ; Seif Kordi, A ; Rashidi, A. M ; Koolivand, H ; Sharif University of Technology
    Elsevier Ltd 
    Abstract
    This study deals with an experimental investigation on the thermal performance of a mechanical wet cooling tower with counter flow arrangement by using multi-walled carbon nanotubes (MWNTs) and nanoporous graphene nanofluids. Stable nanofluids were prepared through two-step procedure by using water with properties taken from a working cooling tower in the South of Iran. Zeta potential revealed suitable stability of MWNTs and nanoporous graphene nanofluids. Thermal and rheological properties of the nanofluids were investigated. It was found that thermal conductivity increases by 20% and 16% at 45°C for MWNTs and nanoporous graphene nanofluids, respectively. The increase in density and... 

    Part load behavior of molten salt cavity receiver solar tower plants under storage mode operational mode

    , Article ASME 2016 10th International Conference on Energy Sustainability, ES 2016, collocated with the ASME 2016 Power Conference and the ASME 2016 14th International Conference on Fuel Cell Science, Engineering and Technology, 26 June 2016 through 30 June 2016 ; Volume 1 , 2016 ; 9780791850220 (ISBN) Mostafavi Tehrani, S. S ; Shafiei Ghazani, A ; Taylor, R. A ; Saberi, P ; Sharif University of Technology
    American Society of Mechanical Engineers  2016
    Abstract
    The performance of the tower based concentrated solar thermal (CST-tower) plant is very sensitive to the operation strategy of the plant and the incident heat flux on the receiver. To date, most studies have been examined only the design mode characteristics of the cavity receivers, but this paper significantly expands the literature by considering non-design operating conditions of this important sub-component of the CST-tower plants. A feasible non-design operating conditions of the cavity receivers that was considered in this study is the storage mode of operation. Two practical dynamic control strategies were examined then to find the most efficient approach: fixed solar field mass... 

    A computational method for optimal design of the multi-tower heliostat field considering heliostats interactions

    , Article Energy ; Volume 106 , 2016 , Pages 240-252 ; 03605442 (ISSN) Piroozmand, P ; Boroushaki, M ; Sharif University of Technology
    Elsevier Ltd 
    Abstract
    In multi-tower heliostat fields, although heliostats are capable of aiming at different receivers during the day, due to different orientations, neighboring heliostats might affect shading and blocking efficiency of each other reciprocally. In the proposed method of this paper, considering the mentioned effects and based on a group decision-making approach, each heliostat chooses the best receiver thus ensuring the highest possible instantaneous efficiency of the field. As a case study, this method is applied for the optimal design of a multi-tower field. Then, the field performance is simulated in a case where heliostats make decisions individually without considering the interactions.... 

    Consumption criteria and energy labeling of wet cooling towers in Iran

    , Article 2009 ASME Power Conference, 21 July 2009 through 23 July 2009 ; 2009 , Pages 153-157 ; 9780791843505 (ISBN) Sajadi, B ; Sayyadi, P ; Saidi, M. H ; Sharif University of Technology
    Abstract
    Increasing concerns about global warming and environmental pollution control has pushed the relevant organizations to set regulations and to develop programs for energy saving. In addition, for many high energy using appliances, energy labeling provides the end user with important data to select energy-efficient equipments and encourage the manufacturers to enhance the performance of their productions. In this research, a new energy-saving program for wet cooling towers has been developed. Considering a thermo-hydraulic analysis, a novel Energy Index (IE) has been extracted which takes all aspects of the problem into account. The present index can be used as a proper criterion for energy... 

    Recovery of cooling tower blowdown water for reuse: the investigation of different types of pretreatment prior nanofiltration and reverse osmosis

    , Article Journal of Water Process Engineering ; Volume 10 , 2016 , Pages 188-199 ; 22147144 (ISSN) Davood Abadi Farahani, M. H ; Borghei, S. M ; Vatanpour, V ; Sharif University of Technology
    Abstract
    The suitability of two different pretreatment methods, i.e., coagulation-filtration and ultrafiltration (UF), and two final membrane treatment technologies, namely nanofiltration (NF) and reverse osmosis (RO), for desalination of a cooling tower blowdown (CTBD) was investigated. Particular attention was paid to ensuring that the best pretreatment method could enhance the permeate flux and lifespan of the NF and RO membranes and decrease the membranes' fouling characteristics. Furthermore, the difference of NF and RO performances in CTBD treatment was investigated. In order to find the most appropriate type of coagulant, coagulant dosage, pH and co-coagulant dosage, 21 jar tests were... 

    Demethanizer Debottlenecking in an Olefin Plant

    , M.Sc. Thesis Sharif University of Technology Mortazavi, Hamid (Author) ; Farhadi, Fathollah (Supervisor)
    Abstract
    The huge jam complex unit in assaluye (tenth olefin plan) with the capacity of 1320000 tons of ethylene and 306 thousand tons of propylene is considered as one of the biggest olefin units of all world. It is found that the bottleneck of increasing the capacity is the demethanizer unit. In this thesis, after simulation of the demethanizer towers, capacity enhancement is accomplished along with comparing the outlet stream with PFD data in terms of mass fractions, temperature and pressure. in addition, the hydrolic treat ment of towers is checked. This is continued till a problem occures in each of towers. In the bottleneck capacity , a solution and some changes have been offered. Thereafter... 

    Experimental investigation of a modular wind tower in hot and dry regions

    , Article Energy for Sustainable Development ; Volume 39 , 2017 , Pages 21-28 ; 09730826 (ISSN) M. R. Khani, S ; Bahadori, M. N ; Dehghani Sanij, A. R ; Sharif University of Technology
    Elsevier B.V  2017
    Abstract
    Passive cooling systems such as wind towers or wind catchers can create thermal comfort for building residents in hot and dry regions. This paper introduces an experimental study of a modular design of wind tower called the modular wind tower with wetted surfaces. Air temperature, relative humidity (RH) and airflow velocity parameters were measured at different times and at points when the velocity of the ambient air was zero. The results show that the modular wind tower can decrease the air temperature by an average of 10 °C and increase the relative humidity of airflow in a building by approximately 36% on average. Additionally, the wind tower can create the airflow velocity entering the... 

    Performance evaluation of a modular design ofwind tower withwetted surfaces

    , Article Energies ; Volume 10, Issue 7 , 2017 ; 19961073 (ISSN) Khani, S. M. R ; Bahadori, M. N ; Dehghani Sanij, A ; Nourbakhsh, A ; Sharif University of Technology
    MDPI AG  2017
    Abstract
    Wind towers or wind catchers, as passive cooling systems, can provide natural ventilation in buildings located in hot, arid regions. These natural cooling systems can provide thermal comfort for the building inhabitants throughout the warm months. In this paper, a modular design of a wind tower is introduced. The design, called a modular wind tower with wetted surfaces, was investigated experimentally and analytically. To determine the performance of the wind tower, air temperature, relative humidity (RH) and air velocity were measured at different points. Measurements were carried out when the wind speed was zero. The experimental results were compared with the analytical ones. The results... 

    Annual comparative performance and cost analysis of high temperature, sensible thermal energy storage systems integrated with a concentrated solar power plant

    , Article Solar Energy ; Volume 153 , 2017 , Pages 153-172 ; 0038092X (ISSN) Mostafavi Tehrani, S. S ; Taylor, R. A ; Nithyanandam, K ; Shafiei Ghazani, A ; Sharif University of Technology
    Elsevier Ltd  2017
    Abstract
    The present study conducts a comprehensive comparative techno-economic analysis of some near-term sensible thermal energy storage (TES) alternatives to the ‘standard’ two-tank molten salt system for concentrated solar power (CSP) plants. As such, we conducted detailed, relative annual transient simulations for single-medium thermocline (SMT), dual-media thermocline (DMT), and shell-and-tube (ST) systems. To be consistent with recent literature, the DMT and ST systems use concrete with a porosity of 0.2 (e.g. where concrete occupies 80% of the system) as their low cost filler material. The systems were integrated into a validated 19.9 MWe Gemasolar CSP model, which has a solar multiple of... 

    Coordinated actors for reliable self-adaptive systems

    , Article Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics), 19 October 2016 through 21 October 2016 ; Volume 10231 LNCS , 2017 , Pages 241-259 ; 03029743 (ISSN) ; 9783319576657 (ISBN) Bagheri, M ; Akkaya, I ; Khamespanah, E ; Khakpour, N ; Sirjani, M ; Movaghar, A ; Lee, E. A ; Khosravi, R ; Kouchnarenko, O ; Sharif University of Technology
    Abstract
    Self-adaptive systems are systems that automatically adapt in response to environmental and internal changes, such as possible failures and variations in resource availability. Such systems are often realized by a MAPE-K feedback loop, where Monitor, Analyze, Plan and Execute components have access to a runtime model of the system and environment which is kept in the Knowledge component. In order to provide guarantees on the correctness of a self-adaptive system at runtime, the MAPE-K feedback loop needs to be extended with assurance techniques. To address this issue, we propose a coordinated actor-based approach to build a reusable and scalable model@runtime for self-adaptive systems in the... 

    Aerodynamic Improvement of Cooling Systems for a Thermal Power Plant Using CFD

    , M.Sc. Thesis Sharif University of Technology Salemkar, Hossein (Author) ; Darbandi, Masoud (Supervisor)
    Abstract
    This research considers the wind effects on the thermal deficiency of natural draught dry cooling tower (NDDCT) using the CFD tool. To have a realistic study, the NDDCT of Shazand Powerplant, located in Shazand, Iran, is simulated as the sample cooling tower design points. Considering of Shazand NDDCT model, the mal-effects of local wind were studied against its thermal efficiency. As is known, the thermal efficiency of a NDDCT can be affected by local wind in either its upper (i.e., outlet section) or lower (i.e., the radiator section) parts. In this study, a full study is performed to quantify the mal-effects of local wind on either upper or lower parts of one tower. The results show that...