Loading...
Search for: water-analysis
0.012 seconds
Total 42 records

    Improvement of Photocatalytic Efficiency of Nano-Titania Compsites

    , Ph.D. Dissertation Sharif University of Technology Koohestani, Hassan (Author) ; Sadrnezhad, Khatiboleslam (Supervisor)
    Abstract
    Semiconductor-based photo catalysts, titanium dioxide (TiO2) especially, have been extensively studied for the oxidative photo destruction of organic pollutants in wastewaters and hydrogen production as a green energy source. Much effort has been made to remove the restrictions on the use of TiO2 and challenges related to the recovery of powdery photocatalysts. In this study, copper oxide (CuO) and Zirconium oxide (ZrO2) were used to synthesize nanocomposites. Composition of TiO2/CuO and TiO2/ZrO2 with different weight percentages of second dioxide was synthesized by chemical methods and structural properties of samples were studied by X-ray diffraction and scanning electron microscopy.... 

    Development of Microextraction Methods
    for the Trace Determination of Organic Compounds in Biological and Environmental Media

    , Ph.D. Dissertation Sharif University of Technology Khalilian, Faezeh (Author) ; Bagheri, Habib (Supervisor)
    Abstract
    The approach of this thesis is to develop and simplify robust microextraction techniques and apply these developed methods to real samples and complex matrices. Firstly, a modified solvent microextraction with back extraction method (SME/BE) combined with high performance liquid chromatography and fluorescence detection (HPLC-FD) was developed for the determination of citalopram in human plasma. Extraction process was performed in a home-made total glass vial without using a teflon ring, usually employed in SME/BE. The evaluation results demonstrated that the calibration curve showed linearity in the range of 1.0–130.0 ng/mL which covers therapeutic window and even lower amounts which is... 

    Second-order calibration for simultaneous determination of pharmaceuticals in water samples by solid-phase extraction and fast high-performance liquid chromatography with diode array detector

    , Article Chemometrics and Intelligent Laboratory Systems ; Vol. 137, issue , 2014 , pp. 146-154 ; ISSN: 01697439 Akvan, N ; Parastar, H ; Sharif University of Technology
    Abstract
    A fast high-performance liquid chromatography-diode array detection (HPLC-DAD) approach combined to solid phase extraction (SPE) as a pre-concentration step is developed for simultaneous determination of five selected pharmaceuticals (carbamazepine, naproxen, diclofenac, gemfibrozil and mefenamic acid) in water samples. The effective factors on the efficiency of SPE procedure are optimized using faced-centered central composite design (FCCD). In addition, multi-response optimization by using Derringer's desirability function is used to find the optimum experimental conditions for extraction of analytes from well and river waters. Due to the complexity of water matrices and the presence of... 

    On-line micro solid-phase extraction of clodinafop propargyl from water, soil and wheat samples using electrospun polyamide nanofibers

    , Article Chromatographia ; Vol. 77, issue. 9-10 , May , 2014 , p. 723-728 Bagheri, H ; Asgari, S ; Piri-Moghadam, H ; Sharif University of Technology
    Abstract
    An on-line extraction/determination set up was designed for micro solid-phase extraction of clodinafop propargyl from water, soil and wheat samples using electrospun polyamide nanofiber mats. The prepared mats were packed in a stainless steel tube which conveniently acted as a high-performance liquid chromatography injection loop. Influential parameters affecting the extraction efficiency were optimized using a distilled water sample fortified with 25 μg L-1 of clodinafop propargyl. An enrichment factor of 440 was achieved for clodinafop propargyl indicating the ability of the whole procedure. Under the optimum conditions, the linearity for the analyte was in the range of 6-700 μg L-1, while... 

    Grafting the sol-gel based sorbents by diazonium salts: A novel approach toward unbreakable capillary microextraction

    , Article Journal of Chromatography A ; Volume 1318 , November , 2013 , Pages 58-64 ; 00219673 (ISSN) Bagheri, H ; Bayat, P ; Piri Moghadam, H ; Sharif University of Technology
    2013
    Abstract
    The present work deals with a novel approach for grafting a sol-gel based sorbent, using diazonium salts for preparation of an unbreakable capillary microextraction (CME) device in on-line combination with high performance liquid chromatography (HPLC). The use of diazonium salts modifier allowed all types of metallic and non-metallic substrates to be used without any limitation. Substrates including copper, brass, stainless steel and polytetrafluoroethylene (PTFE) were chosen to be functionalized by chemical or electrochemical reduction of 4-amino phenyl acetic acid. Then, 3-(trimethoxysilyl)propylamine (3TMSPA) was selected as the precursor and the only reagent for preparation of the... 

    High-throughput micro-solid phase extraction on 96-well plate using dodecyl methacrylate-ethylen glycol dimethacrylate monolithic copolymer

    , Article Analytica Chimica Acta ; Volume 792 , August , 2013 , Pages 59-65 ; 00032670 (ISSN) Bagheri, H ; Es'haghi, A ; Es-haghi, A ; Mohammadkhani, E ; Sharif University of Technology
    2013
    Abstract
    A novel high-throughput device based on 96-micro-solid phase extraction (96-μ-SPE) system was constructed for multiresidue determination of nine pesticides in aquatic samples. The extraction procedure was performed on a commercially available 96-well plate system. The extraction module consisted of 96 pieces of 1cm×3cm of cylindrically shaped stainless steel meshes. The prepared meshes were fixed in a home-made polytetrafluoroethylene-based constructed ninety-six holes block for possible simultaneous immersion of meshes into the center of individual wells. Dodecyl methacrylate and ethylene glycol dimethacrylate was copolymerized as a monolithic polymer and placed in the cylindrically shaped... 

    Immersed solvent microextraction of aryloxyphenoxypropionate herbicides from aquatic media

    , Article International Journal of Environmental Analytical Chemistry ; Volume 93, Issue 4 , Feb , 2013 , Pages 450-460 ; 03067319 (ISSN) Bagheri, H ; Es'haghi, A ; Es-haghi, A ; Sharif University of Technology
    2013
    Abstract
    An immersed solvent microextraction (SME) method was successfully developed for the trace enrichment of aryloxyphenoxypropionate herbicides from aquatic media. A microdrop of toluene was used as the extraction solvent. Some important extraction parameters such as type of solvent, solvent dropsize, stirring rate, ionic strength and extraction time were investigated and optimized. The microdrop volume of 1.5 μL, a sampling time of 25 min, and use of toluene were major parameters for achieving high enrichment factors. The linearity was studied by preconcentration of 4 mL of the water samples spiked with a standard solution of aryloxyphenoxypropionates at the concentration range of 0.15 to 30 ng... 

    Multiresidue determination of pesticides from aquatic media using polyaniline nanowires network as highly efficient sorbent for microextraction in packed syringe

    , Article Analytica Chimica Acta ; Volume 740 , 2012 , Pages 43-49 ; 00032670 (ISSN) Bagheri, H ; Alipour, N ; Ayazi, Z ; Sharif University of Technology
    Abstract
    A simple, rapid and sensitive method based on microextraction in packed syringe (MEPS), in combination with gas chromatography-mass spectrometry (GC-MS) was developed. Polyaniline (PANI) nanowires network was synthesized and used as sorbent of MEPS for the multiresidue determination of selected analytes from triazine, organochlrorine and organophosphorous pesticides in aqueous samples. The PANI nanowires network was prepared using soft template technique and its characterization was studied by scanning electron microscopy (SEM). The presence of micelles in this methodology showed to be an important parameter in shaping the growing polymer. Hexadecyltrimethylammonium bromide (HTAB) was used... 

    Larval habitats and biodiversity of anopheline mosquitoes (Diptera: Culicidae) in a malarious area of southern Iran

    , Article Journal of Vector Borne Diseases ; Volume 49, Issue 2 , Jun , 2012 , Pages 91-100 ; 09729062 (ISSN) Hanafi-Bojd, A. A ; Vatandoost, H ; Oshaghi, M. A ; Charrahy, Z ; Haghdoost, A. A ; Sedaghat, M. M ; Abedi, F ; Soltani, M ; Raeisi, A ; Sharif University of Technology
    JVBD  2012
    Abstract
    Background & objectives: Malaria is the most important mosquito-borne disease in Iran. It is endemic in south to southeastern part of the country. Knowledge about bio-ecology of vectors will support authorities for appropriate management of the disease. Bashagard district is one of the main endemic areas for malaria in south of Iran. This study was conducted to determine anopheline fauna, diversity and affinity in the area, characterization of larval habitats, and mapping their potential distribution across the district. Methods: The potential aquatic habitats for Anopheles larvae were extracted from Indian Remote Sensing Satellite (IRS) image and digital elevation model of the area using... 

    Aniline-silica nanocomposite as a novel solid phase microextraction fiber coating

    , Article Journal of Chromatography A ; Volume 1238 , May , 2012 , Pages 22-29 ; 00219673 (ISSN) Bagheri, H ; Roostaie, A ; Sharif University of Technology
    2012
    Abstract
    A new unbreakable solid phase microextraction (SPME) fiber coating based on aniline-silica nanocomposite was electrodeposited on a stainless steel wire. The electropolymerization process was carried out at a constant deposition potential, applied to the corresponding aqueous electrolyte containing aniline and silica nanoparticles. The scanning electron microscopy (SEM) images showed the non-smooth and the porous surface structure of the prepared nanocomposite. The applicability of the new fiber coating was examined by headspace-solid phase microextraction (HS-SPME) of some environmentally important polycyclic aromatic hydrocarbons (PAHs), as model compounds, from aqueous samples.... 

    Reprint of: Extraction of fluoxetine from aquatic and urine samples using sodium dodecyl sulfate-coated iron oxide magnetic nanoparticles followed by spectrofluorimetric determination

    , Article Analytica Chimica Acta ; Volume 716 , February , 2012 , Pages 61-65 ; 00032670 (ISSN) Bagheri, H ; Zandi, O ; Aghakhani, A ; Sharif University of Technology
    2012
    Abstract
    A new method based on the combination of magnetic solid phase extraction (MSPE) and spectrofluorimetric determination was developed for isolation and preconcentration of fluoxetine form aquatic and biological samples using sodium dodecyl sulfate (SDS) coated Fe 3O 4 nanoparticles (NPs) as a sorbent. The unique properties of Fe 3O 4 NPs including high surface area and strong magnetism were utilized effectively in the MSPE process. Effect of different parameters influencing the extraction efficiency of fluoxetine including the amount of Fe 3O 4 and SDS, pH value, sample volume, extraction time, desorption solvent and time were optimized. Under optimized condition, the method was successfully... 

    Reinforced polydiphenylamine nanocomposite for microextraction in packed syringe of various pesticides

    , Article Journal of Chromatography A ; Volume 1222 , January , 2012 , Pages 13-21 ; 00219673 (ISSN) Bagheri, H ; Ayazi, Z ; Es'haghi, A ; Aghakhani, A ; Sharif University of Technology
    2012
    Abstract
    Reinforced polydiphenylamine (PDPA) nanocomposite was synthesized by oxidation of diphenylamine in 4molL-1 sulfuric acid solution containing a fixed amount of carbon nanotubes (CNTs) in the presence of cetyltrimethylammonium bromide (CTAB). The surface characteristic of PDPA and PDPA/CNT nanocomposites was investigated using scanning electron microscopy (SEM). The prepared PDPA/CNT nanocomposite was used as an extraction medium for microextraction in packed syringe (MEPS) of selected pesticides from aquatic environment. The effect of CNT doping level and the presence of surfactant on the extraction capability of nanocomposite was investigated and it was revealed that when 4% (w/w) of CNT in... 

    A polypyrrole-based sorptive microextraction coating for preconcentration of malathion from aquatic media

    , Article Chromatographia ; Volume 74, Issue 9-10 , 2011 , Pages 731-735 ; 00095893 (ISSN) Bagheri, H ; Aghakhani, A ; Ayazi, Z ; Khakinezhad, M ; Sharif University of Technology
    Abstract
    A new micro-solid phase extraction method was developed by combining solid-phase extraction and stir bar sorptive extraction to benefit from the advantages of both techniques. A polypyrrole coating was electrochemically synthesized on the surface of an already used graphite furnace, employed in electro-thermal atomic absorption spectroscopy. The cylindrical geometry of the graphite tube provided a rather huge surface area, suitable for sorptive extraction. The novel sorbent coating was examined as an extracting medium to isolate malathion. Effects of different parameters such as extraction time, salt concentration, sample volume, desorption solvent and time were investigated and optimized.... 

    Magnetic nanoparticle-based micro-solid phase extraction and GC-MS determination of oxadiargyl in aqueous samples

    , Article Chromatographia ; Volume 74, Issue 5-6 , 2011 , Pages 483-488 ; 00095893 (ISSN) Bagheri, H ; Zandi, O ; Aghakhani, A ; Sharif University of Technology
    Abstract
    A new facile, rapid, inexpensive, and sensitive method based on magnetic micro-solid phase extraction (M-μ-SPE) coupled to gas chromatography-mass spectrometry (GC-MS) was developed for determination of the herbicide oxadiargyl in environmental water samples. The feasibility of employing non-modified magnetic nanoparticles (MNPs) as sorbent was examined and applied to perform the extraction process. Influential parameters affecting the extraction efficiency along with desorption conditions were investigated and optimized. The limit of detection (LOD, S/N = 3) and limit of quantification (LOQ, S/N = 10) of the method under optimized conditions were 0.005 and 0.030 ng mL-1, respectively. The... 

    Extraction of fluoxetine from aquatic and urine samples using sodium dodecyl sulfate-coated iron oxide magnetic nanoparticles followed by spectrofluorimetric determination

    , Article Analytica Chimica Acta ; Volume 692, Issue 1-2 , 2011 , Pages 80-84 ; 00032670 (ISSN) Bagheri, H ; Zandi, O ; Aghakhani, A ; Sharif University of Technology
    Abstract
    A new method based on the combination of magnetic solid phase extraction (MSPE) and spectrofluorimetric determination was developed for isolation and preconcentration of fluoxetine form aquatic and biological samples using sodium dodecyl sulfate (SDS) coated Fe3O4 nanoparticles (NPs) as a sorbent. The unique properties of Fe3O4 NPs including high surface area and strong magnetism were utilized effectively in the MSPE process. Effect of different parameters influencing the extraction efficiency of fluoxetine including the amount of Fe3O4 and SDS, pH value, sample volume, extraction time, desorption solvent and time were optimized. Under optimized condition, the method was successfully applied... 

    A novel needle trap sorbent based on carbon nanotube-sol-gel for microextraction of polycyclic aromatic hydrocarbons from aquatic media

    , Article Analytica Chimica Acta ; Volume 683, Issue 2 , January , 2011 , Pages 212-220 ; 00032670 (ISSN) Bagheri, H ; Ayazi, Z ; Aghakhani, A ; Sharif University of Technology
    2011
    Abstract
    A new type of composite material based on carbon nanotubes (CNTs) and sol-gel chemistry was prepared and used as sorbent for needle trap device (NTD). The synthesized composite was prepared in a way to disperse CNTs molecules in a sol-gel polymeric network. CNT/silica composites with different CNT doping levels were successfully prepared, and the extraction capability of each composite was evaluated. Effects of surfactant and the oxidation duration of CNTs on the extraction efficiency of synthesized composites were also investigated. The applicability of the synthesized sorbent was examined by developing a method based on needle trap extraction (NTE) and gas chromatography mass spectrometry... 

    Roles of inorganic oxide nanoparticles on extraction efficiency of electrospun polyethylene terephthalate nanocomposite as an unbreakable fiber coating

    , Article Journal of Chromatography A ; Volume 1375 , 2015 , Pages 8-16 ; 00219673 (ISSN) Bagheri, H ; Roostaie, A ; Sharif University of Technology
    Elsevier  2015
    Abstract
    In the present work, the roles of inorganic oxide nanoparticles on the extraction efficiency of polyethylene terephthalate-based nanocomposites were extensively studied. Four fiber coatings based on polyethylene terephthalate nanocomposites containing different types of nanoparticles along with a pristine polyethylene terephthalate polymer were conveniently electrospun on stainless steel wires. The applicability of new fiber coatings were examined by headspace-solid phase microextraction of some environmentally important volatile organic compound such as benzene, toluene, ethylbenzene and xylene (BTEX), as model compounds, from aqueous samples. Subsequently, the extracted analytes were... 

    Optimization of dispersive liquid-liquid microextraction and improvement of detection limit of methyl tert-butyl ether in water with the aid of chemometrics

    , Article Journal of Chromatography A ; Volume 1217, Issue 45 , November , 2010 , Pages 7017-7023 ; 00219673 (ISSN) Karimi, M ; Sereshti, H ; Samadi, S ; Parastar, H ; Sharif University of Technology
    2010
    Abstract
    Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry-selective ion monitoring (GC-MS-SIM) was applied to the determination of methyl tert-butyl ether (MTBE) in water samples. The effect of main parameters affecting the extraction efficiency was studied simultaneously. From selected parameters, volume of extraction solvent, volume of dispersive solvent, and salt concentration were optimized by means of experimental design. The statistical parameters of the derived model were R 2=0.9987 and F=17.83. The optimal conditions were 42.0μL for extraction solvent, 0.30mL for disperser solvent and 5% (w/v) for sodium chloride. The calibration linear range... 

    Evaluation of spatial and temporal variation in water quality by pattern recognition techniques: A case study on Jajrood River (Tehran, Iran)

    , Article Journal of Environmental Management ; Volume 91, Issue 4 , 2010 , Pages 852-860 ; 03014797 (ISSN) Razmkhah, H ; Abrishamchi, A ; Torkian, A ; Sharif University of Technology
    2010
    Abstract
    In this paper, principal component analysis (PCA) and hierarchical cluster analysis (CA) methods have been used to investigate the water quality of Jajrood River (Iran) and to assess and discriminate the relative magnitude of anthropogenic and "natural" influences on the quality of river water. T, EC, pH, TDS, NH4, NO3, NO2, Turb., T.Hard., Ca, Mg, Na, K, Cl, SO4, SiO2 as physicochemical and TC, FC as biochemical variables have been analyzed in the water samples collected every month over a three-year period from 18 sampling stations along a 50 km section of Jajrood River that is under the influence of anthropogenic and natural changes. Exploratory analysis of experimental data has been... 

    A single–step synthesized supehydrophobic melamine formaldehyde foam for trace determination of volatile organic pollutants

    , Article Journal of Chromatography A ; Volume 1525 , 2017 , Pages 10-16 ; 00219673 (ISSN) Bagheri, H ; Zeinali, S ; Baktash, M. Y ; Sharif University of Technology
    Abstract
    Superhydrophobic materials have attracted many attentions in recent years while their application in sample preparation remained almost intact. In this project, a rough surface of melamine formaldehyde foam was silanized by chemical deposition of trichloromethylsilane to form a highly porous and superhydrophobic material, presumably a suitable medium for extracting non–polar compounds such as benzene and its methyl derivatives. The prepared sorbent was packed in a needle for the headspace needle–trap microextraction of benzene, toluene, ethylbenzene and xylenes (BTEX). Major parameters associated with the extraction/desorption processes were considered for optimization. Under the optimized...