    The evaluation of PM10, PM2.5, and PM1 concentrations during the Middle Eastern Dust (MED) events in Ahvaz, Iran, from april through september 2010

    , Article Journal of Arid Environments ; Volume 77, Issue 1 , 2012 , Pages 72-83 ; 01401963 (ISSN) Shahsavani, A ; Naddafi, K ; Jafarzade Haghighifard, N ; Mesdaghinia, A ; Yunesian, M ; Nabizadeh, R ; Arahami, M ; Sowlat, M. H ; Yarahmadi, M ; Saki, H ; Alimohamadi, M ; Nazmara, S ; Motevalian, S. A ; Goudarzi, G ; Sharif University of Technology
    Abstract
    In this study, PM10, PM2.5, and PM1 concentrations were measured from April through September 2010. These measurements were made every six days and on days with dust events using a Grimm Model 1.177 aerosol spectrometer. Meteorological data were also collected. Overall mean values of 319.6 ± 407.07, 69.5 ± 83.2, and 37.02 ± 34.9 μg/m3 were obtained for PM10, PM2.5, and PM1, respectively, with corresponding maximum values of 5337.6, 910.9, and 495 μg/m3. The presence of the westerly prevailing wind implied that Iraq is the major source of dust events in this area. A total of 72 dust days and 711 dust hours occurred in the study area. The dust events occurred primarily during July. The longest... 

    Particulate emissions of real-world light-duty gasoline vehicle fleet in Iran

    , Article Environmental Pollution ; Volume 292 , 2022 ; 02697491 (ISSN) Shahne, M. Z ; Arhami, M ; Hosseini, V ; Al Haddad, E ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Fine particulate matter cause profound adverse health effects in Iran. Road traffic is one of the main sources of particulate matter (PM) in urban areas, and has a large contribution in PM2.5 and organic carbon concentration, in Tehran, Iran. The composition of fine PM vehicle emission is poorly known, so this paper aims to determine the mixed fleet source profile by using the analysed data from the two internal stations and the emission factor for PM light-duty vehicles emission. Tunnels are ideal media for extraction vehicle source profile and emission factor, due to vehicles are the only source of pollutant in the urban tunnels. In this study, PM samples were collected simultaneously in... 

    A novel regression imputation framework for Tehran air pollution monitoring network using outputs from WRF and CAMx models

    , Article Atmospheric Environment ; Volume 187 , 2018 , Pages 24-33 ; 13522310 (ISSN) Shahbazi, H ; Karimi, S ; Hosseini, V ; Yazgi, D ; Torbatian, S ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    Missing or incomplete data in short or long intervals is a common problem in measuring air pollution. Severe issues may arise when dealing with missing data for time-series prediction schemes or mean analysis. This study aimed to develop a new regression imputation framework to impute missing values in the hourly air quality data set of Tehran and enhance the applicability of Tehran Air Pollution Forecasting System (TAPFS). The proposed framework was designed based on three types of features including measurements of other stations, WRF and CAMx physical models. In this framework, elastic net and neuro-fuzzy networks were efficiently combined in a two-layer structure. The framework was... 

    Assessment of emission reduction scenarios with a focus on the impact of vehicle fleets on tehran air quality: case study

    , Article Transportation Research Record ; Volume 2673, Issue 5 , 2019 , Pages 197-207 ; 03611981 (ISSN) Shahbazi, H ; Hosseini, V ; Torbatian, S ; Hamedi, M ; Sharif University of Technology
    SAGE Publications Ltd  2019
    Abstract
    In recent years, the city of Tehran has frequently experienced severe air pollution episodes, and the increase in the use of vehicles has exacerbated this critical situation. It is unclear to what extent each vehicle category contributes to the production of pollution during a pollution event. For this purpose, a combination of the weather research and forecasting (WRF) and the Comprehensive Air Quality Model with Extensions (CAMx) modeling systems was used to simulate the distributions of pollutant concentrations over Tehran in a pollution episode from December 3 to 23, 2017. First, the performance of the modeling system was evaluated with respect to the simulation outputs against... 

    Impact of mobile source emission inventory adjustment on air pollution photochemical model performance

    , Article Urban Climate ; Volume 32 , 2020 Shahbazi, H ; Hosseini, V ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Coupled weather forecasting and chemical transport models are useful tools to evaluate air pollution episodes in big cities for the purpose of forecasting and air pollution abatement measures' evaluation. However, large set of accurate data of various sources and modeling calibrations are needed for such complex modeling system to be reliable. The problem becomes more obvious when the model is operated over a domain in which there is a general lack of accurate input data such as emission inventory data. The current study investigates the possibility of model tuning for more accurate prediction of air pollutant concentrations in the city of Tehran in an air pollution episode as a case study.... 

    An emission inventory update for Tehran: The difference between air pollution and greenhouse gas source contributions

    , Article Atmospheric Research ; Volume 275 , 2022 ; 01698095 (ISSN) Shahbazi, H ; Abolmaali, A. M ; Alizadeh, H ; Salavati, H ; Zokaei, H ; Zandavi, R ; Torbatian, S ; Yazgi, D ; Hosseini, V ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Many highly populated cities are still struggling to reach clean air targets, while the zero greenhouse gas emission objectives may accelerate the path toward healthy air for all. Still, there is a fine line between intensive electrification's impact on greenhouse gas emissions and criteria air contaminants depending on the source of the electricity. In this study, the previous version of the emission inventory for Tehran was evaluated and re-calculated in a detailed bottom-up approach to provide the most updated data on the contribution of stationary sources derived by power plants vs. mobile sources. The objectives were to update the emission inventory for improved policymaking, study the... 

    Nonlinear robust control of air handling units to improve the indoor air quality & CO2 concentration: A comparison between H∞ & decoupled sliding mode controls

    , Article Applied Thermal Engineering ; Volume 160 , 2019 ; 13594311 (ISSN) Setayesh, H ; Moradi, H ; Alasty, A ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    Air-handling units (AHUs) are the installations responsible for the control of temperature and humidity inside a space using the heating, cooling, humidifier and drying air components. In this research, a multivariable nonlinear dynamic model of the AHU with one zone in the VAV (variable air volume) system for working in the summer is considered. The indoor temperature, relative humidity and carbon dioxide concentration are controlled via manipulation of the valve positions of the air flow rate, cold water flow rate and fresh air percent. Due to the complexity and nonlinearity of AHU model and also the existence of various operating points and uncertainty, model uncertainties are included.... 

    CFD aided procedure for optimizing electrical mobility spectrometer

    , Article Defect and Diffusion Forum ; Volume 366 , 2016 , Pages 73-87 ; 10120386 (ISSN) Saifi, R ; Shaygani, A ; Sani, M ; Saidi, M. S ; Sharif University of Technology
    Trans Tech Publications Ltd 
    Abstract
    Aerosol measurement is used in a variety of fields such as nanotechnology, materials science, pollution monitoring, air quality measurements, combustion and engine exhaust analysis, inhalation toxicology, and medical studies. One of the most prevalent methods for aerosol measurement is to use electrical mobility. An electrical mobility spectrometer (EMS) is used to measure aerosol particles size distribution ranging from 10-1000 nanometers, under the influence of an electric field. The accuracy of this distribution is influenced by flow conditions, the geometry of the EMS, the electric field, and the number of electrode rings. In this work, a multi-channel EMS is studied using computational... 

    The effect of source motion on contaminant distribution in the cleanrooms

    , Article Energy and Buildings ; Volume 43, Issue 4 , April , 2011 , Pages 966-970 ; 03787788 (ISSN) Saidi, M. H ; Sajadi, B ; Molaeimanesh, G. R ; Sharif University of Technology
    2011
    Abstract
    In the recent decades, cleanrooms have found growing applications in broad range of industries such as pharmacy and microelectronics. Concerns about negative effects of the contaminant exposure on the human health and product quality motivate many researchers towards understanding of the airflow and contaminant distribution though these environments. With an improvement in computational capacity of the computers, computational fluid dynamics (CFD) technique has become a powerful tool to study the engineering problems including indoor air quality (IAQ). In this research, indoor airflow in a full-scale cleanroom is investigated numerically using Eulerian-Eulerian approach. To evaluate the... 

    Integrated analysis of energy-pollution-health nexus for sustainable energy planning

    , Article Journal of Cleaner Production ; Volume 356 , 2022 ; 09596526 (ISSN) Rezazadeh, A. A ; Alizadeh, S ; Avami, A ; Kianbakhsh, A ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    In recent years, the emission of various pollutants has caused many problems for human life and the ecosystem. The prioritization between different air pollution control scenarios is a challenge between scientists and policy-makers. This study develops an integrated method for sustainable energy planning considering the energy-pollution-health nexus. The paper investigates three main pollutants (i.e., PM2.5, SO2, and NOx) of different emission sources (i.e., industrial, residential, and intra-city and suburban transportations) in twelve scenarios. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) is applied to model the air pollution dispersion,... 

    A novel viewpoint to the green city concept based on vegetation area changes and contributions to healthy days: a case study of Mashhad, Iran

    , Article Environmental Science and Pollution Research ; 2021 ; 09441344 (ISSN) Nejatian, A ; Makian, M ; Gheibi, M ; Fathollahi Fard, A. M ; Sharif University of Technology
    Springer Science and Business Media Deutschland GmbH  2021
    Abstract
    One of the significant challenges in urbanization is the air pollution. This highlights the need of the green city concept with reconsideration of houses, factories, and traffic in a green viewpoint. The literature review confirms that this reconsideration for green space has a positive effect on the air quality of large cities and to reduce the air pollution. The purpose of this study is to evaluate the annual vegetation changes in the green space of Mashhad, Iran as a very populated city in the middle east to study the air pollution. To investigate the relationship between the air pollution and vegetation, the Landsat 8 satellite images for summer seasons of 2013–2019 were used to extract... 

    A novel viewpoint to the green city concept based on vegetation area changes and contributions to healthy days: a case study of Mashhad, Iran

    , Article Environmental Science and Pollution Research ; Volume 29, Issue 1 , 2022 , Pages 702-710 ; 09441344 (ISSN) Nejatian, A ; Makian, M ; Gheibi, M ; Fathollahi Fard, A. M ; Sharif University of Technology
    Springer Science and Business Media Deutschland GmbH  2022
    Abstract
    One of the significant challenges in urbanization is the air pollution. This highlights the need of the green city concept with reconsideration of houses, factories, and traffic in a green viewpoint. The literature review confirms that this reconsideration for green space has a positive effect on the air quality of large cities and to reduce the air pollution. The purpose of this study is to evaluate the annual vegetation changes in the green space of Mashhad, Iran as a very populated city in the middle east to study the air pollution. To investigate the relationship between the air pollution and vegetation, the Landsat 8 satellite images for summer seasons of 2013–2019 were used to extract... 

    Optimisation of micro gas turbine by exergy, economic and environmental (3E) analysis

    , Article International Journal of Exergy ; Volume 7, Issue 1 , 2010 , Pages 1-19 ; 17428297 (ISSN) Mozafari, A ; Ahmadi, A ; Ehyaei, M. A ; Sharif University of Technology
    2010
    Abstract
    This research proposes a new method for optimisation of a power generation system based on exergy fuel cost and external social cost of air pollution. A thermodynamic model is provided to estimate the outlet mass flow rates of CO2, CO, NO and NO2 for a gas turbine based on maximising the first and second law efficiencies and minimising the objective function. Results show that inclusion of the external social cost of air pollution increases the optimum excess air ratio if temperature constraint due to metallurgical consideration is disregarded. Otherwise external social cost of air pollution is independent of optimised conditions  

    A numerical study of reactive pollutant dispersion in street canyons with green roofs

    , Article Building Simulation ; Volume 11, Issue 1 , February , 2018 , Pages 125-138 ; 19963599 (ISSN) Moradpour, M ; Afshin, H ; Farhanieh, B ; Sharif University of Technology
    Tsinghua University Press  2018
    Abstract
    Roof greening is a new technique for improvement of outdoor thermal environment which influences air quality through its impacts on thermal and flow field. In order to examine effects of green roofs on reactive pollutant dispersion within urban street canyons, a computational fluid dynamics (CFD) model was employed which contained NO-NO2-O3 photochemistry and energy balance models. Simulations were performed for street canyons with different aspect ratios (H/W) of 0.5, 1.0, and 2.0 such that leaf area density (LAD) of green roofs changed. It was found that roof greening led distribution of pollutants to alter for H/W = 0.5 and 1.0 cases in such a manner that their averaged concentrations had... 

    Characterization of aerosol types over Lake Urmia Basin

    , Article 2019 Central Asian DUst Conference, CADUC 2019, 8 April 2019 through 12 April 2019 ; Volume 99 , 2019 ; 25550403 (ISSN) Moghim, S ; Ramezanpoor, R ; Sharif University of Technology
    EDP Sciences  2019
    Abstract
    Atmospheric aerosols affect the Earth's climate, air quality, and thus human health. This study used the Aerosol Optical Depth (AOD) and the Ångström exponent to cluster different particle types over the Lake Urmia Basin. This classification found desert dust and marine (mixed with continental or local-pollution aerosols) as two main aerosol types over the region, while their sources are not well defined. Although different air masses and wind circulation over the study domain in varied months can help to distinguish aerosol sources, measurements are crucial for a complete evaluation  

    A new approach to exergy analyses of a hybrid desiccant cooling system compares to a vapor compression system

    , Article Applied Mechanics and Materials, 29 July 2011 through 31 July 2011 ; Volume 110-116 , July , 2012 , Pages 2163-2169 ; 16609336 (ISSN) ; 9783037852620 (ISBN) Khosravi, S ; Yau, Y. H ; Mahlia, T. M. I ; Saidi, M. H ; Sharif University of Technology
    Abstract
    In the recent researches HVAC with a based desiccant dehumidifier with a low ambient impact is more efficient in comparison to the traditional systems. Hybrid desiccant cooling systems can be used to control indoor air quality in buildings. This paper presents an integrated energy, entropy and exergy analysis of a hybrid desiccant cooling system compare to a compression system based on first and second laws of thermodynamic. The main objective is the use of a method called exergy costing applied to a conventional compression system that has been chosen to provide the proper conditioned air for a building in hot and humid condition. By applying the same method for the equivalent hybrid... 

    Production of perovskite catalysts on ceramic monoliths with nanoparticles for dual fuel system automobiles

    , Article International Journal of Environmental Science and Technology ; Volume 6, Issue 1 , 2009 , Pages 105-112 ; 17351472 (ISSN) Khanfekr, A ; Arzani, K ; Nemati, A ; Hosseini, M ; Sharif University of Technology
    CEERS  2009
    Abstract
    (Lanthanum, Cerium)(Iron, Manganese, Cobalt, Palladium)(Oxygen)3- Perovskite catalyst was prepared by the citrate route and deposited on ceramic monoliths via dip coating procedure. The catalyst was applied on a car with XU7 motors and the amount of emission was monitored with vehicle emission test systems in Sapco company. The results were compared with the imported catalyst with noble metals such as palladium, platinum and rhodium by Iran Khodro company based on the Euro III standards. The catalysts were characterized by specific surface area measurements, scanning electron microscopy, X-ray diffraction, line scan and map. In the results, obtained in the home made sample, the amount of... 

    The air quality of Tehran underground railway transit system

    , Article BHR Group - 14th International Symposium on Aerodynamics and Ventilation of Tunnels, 11 May 2011 through 13 May 2011 ; May , 2011 , Pages 551-561 ; 9781855981232 (ISBN) Jafari, M. J ; Abbasspour, M ; Mansoori, N ; Moattar, F ; Nouri, N ; Allahyari, M ; Sharif University of Technology
    2011
    Abstract
    This study examines the air quality on line 1 and 2 of Tehran underground metro. The total suspended particulate (TSP), PM10, PM2.5, PM1, CO2, NO, NO2, SO2, relative humidity and air temperature were measured. An integrated air quality index was also calculated for each location. The results revealed that, PMlO, PM2.5, and SO2 concentrations are higher than their environmental standard levels. The in station CO2 levels are higher while its' in train levels are lower than environmental permissible level. The air quality index showed that the in-train air quality is more acceptable than the instation air quality  

    The lake urmia environmental disaster in Iran: a look at aerosol pollution

    , Article Science of the Total Environment ; Volume 633 , 2018 , Pages 42-49 ; 00489697 (ISSN) Hossein Mardi, A ; Khaghani, A ; MacDonald, A. B ; Nguyen, P ; Karimi, N ; Heidary, P ; Karimi, N ; Saemian, P ; Sehatkashani, S ; Tajrishy, M ; Sorooshian, A ; Sharif University of Technology
    Abstract
    Lake Urmia (LU) once was the second largest hypersaline lake in the world, covering up to 6000 km2, but has undergone catastrophic desiccation in recent years resulting in loss of 90% of its area and extensive coverage by playas and marshlands that represent a source of salt and dust. This study examines daily Aerosol Optical Depth (AOD) data from the Moderate Resolution Imaging Spectroradiometer (MODIS) between 2001 and 2015 over northwestern Iran, which encompasses LU. Intriguingly, salt emissions from the LU surface associated with ongoing desiccation do not drive the study region's AOD profile, whereas pollution transported from other regions and emissions around LU are more important.... 

    Characterization of PAHs and metals in indoor/outdoor PM10/PM2.5/PM1 in a retirement home and a school dormitory

    , Article Science of the Total Environment ; Volume 527-528 , September , 2015 , Pages 100-110 ; 00489697 (ISSN) Hassanvand, M. S ; Naddafi, K ; Faridi, S ; Nabizadeh, R ; Sowlat, M. H ; Momeniha, F ; Gholampour, A ; Arhami, M ; Kashani, H ; Zare, A ; Niazi, S ; Rastkari, N ; Nazmara, S ; Ghani, M ; Yunesian, M ; Sharif University of Technology
    Elsevier  2015
    Abstract
    In the present work, we investigated the characteristics of polycyclic aromatic hydrocarbons (PAHs) and metal(loid)s in indoor/outdoor PM10, PM2.5, and PM1 in a retirement home and a school dormitory in Tehran from May 2012 to May 2013. The results indicated that the annual levels of indoor and outdoor PM10 and PM2.5 were much higher than the guidelines issued by the World Health Organization (WHO). The most abundant detected metal(loid)s in PM were Si, Fe, Zn, Al, and Pb. We found higher percentages of metal(loid)s in smaller size fractions of PM. Additionally, the results showed that the total PAHs (ΣPAHs) bound to PM were...