Loading...
Search for:
cardiovascular-system
0.007 seconds
Total 32 records
Life-threatening arrhythmia verification in ICU patients using the joint cardiovascular dynamical model and a bayesian filter
, Article IEEE Transactions on Biomedical Engineering ; Volume 58, Issue 10 PART 1 , 2011 , Pages 2748-2757 ; 00189294 (ISSN) ; Shamsollahi, M. B ; Sharif University of Technology
Abstract
In this paper, a novel nonlinear joint dynamical model is presented, which is based on a set of coupled ordinary differential equations of motion and a Gaussian mixture model representation of pulsatile cardiovascular (CV) signals. In the proposed framework, the joint interdependences of CV signals are incorporated by assuming a unique angular frequency that controls the limit cycle of the heart rate. Moreover, the time consequence of CV signals is controlled by the same phase parameter that results in the space dimensionality reduction. These joint equations together with linear assignments to observation are further used in the Kalman filter structure for estimation and tracking. Moreover,...
A novel distributed model of the heart under normal and congestive heart failure conditions
, Article Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine ; Volume 227, Issue 4 , 2013 , Pages 362-372 ; 09544119 (ISSN) ; Jahed, M ; Sharif University of Technology
2013
Abstract
Conventional models of cardiovascular system frequently lack required detail and focus primarily on the overall relationship between pressure, flow and volume. This study proposes a localized and regional model of the cardiovascular system. It utilizes noninvasive blood flow and pressure seed data and temporal cardiac muscle regional activity to predict the operation of the heart under normal and congestive heart failure conditions. The analysis considers specific regions of the heart, namely, base, mid and apex of left ventricle. The proposed method of parameter estimation for hydraulic electric analogy model is recursive least squares algorithm. Based on simulation results and comparison...
Robust control of LVAD based on the sub-regional modeling of the heart
, Article Scientia Iranica ; Volume 23, Issue 6 , 2016 , Pages 2934-2943 ; 10263098 (ISSN) ; Jahed, M ; Sharif University of Technology
Sharif University of Technology
2016
Abstract
Left Ventricular Assist Devices (LVAD) have received renewed interest as a bridge-to-transplantation as well as a bridge-to-recovery device. Ironically, reports of malfunction and complications have hindered the growth of this device. In particular, the main concern is LVAD's susceptibility to excessive backlash and suction as a result of ows that are either too low or high, respectively. This study utilizes a well-established physiological model of the cardiovascular system as a reliable platform to study a proposed adaptive robust controller for a rotary motor based LVAD which overcomes such shortcomings. Proposed controller performance is evaluated by comparing simulated natural heart...
Conceptual modeling of cardiovascular sounds
, Article 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005, Shanghai, 1 September 2005 through 4 September 2005 ; Volume 7 VOLS , 2005 , Pages 2308-2311 ; 05891019 (ISSN); 0780387406 (ISBN); 9780780387409 (ISBN) ; Tehrani Fard, A. A ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2005
Abstract
In this paper, it is shown that the main source of mechanical energy of cardiovascular (CV) system i.e., rhythmic heart contraction is transformed to the oscillations of the CV walls and blood flow, and finally CV acoustical waves. These waves propagate through both blood flow (hemodynamical pathways) and tissues (viscoelastical pathways) toward the skin. Nonetheless, the CV walls could be assumed as the source of acoustical waves, since they act as the interface between blood flows and other tissues including skin. After obtaining the approximate accelerations of CV walls from pressure-flow (PF) models, we also needed to model the viscoelastical pathways until the skin. Some improvements on...
Early cancer detection in blood vessels using mobile nanosensors
, Article IEEE Transactions on Nanobioscience ; Volume 18, Issue 2 , 2019 , Pages 103-116 ; 15361241 (ISSN) ; Ahmadzadeh, A ; Wicke, W ; Jamali, V ; Schober, R ; Nasiri Kenari, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2019
Abstract
In this paper, we propose using mobile nanosensors (MNSs) for early stage anomaly detection. For concreteness, we focus on the detection of cancer cells located in a particular region of a blood vessel. These cancer cells produce and emit special molecules, so-called biomarkers, which are symptomatic for the presence of anomaly, into the cardiovascular system. Detection of cancer biomarkers with conventional blood tests is difficult in the early stages of a cancer due to the very low concentration of the biomarkers in the samples taken. However, close to the cancer cells, the concentration of the cancer biomarkers is high. Hence, detection is possible if a sensor with the ability to detect...
Exact simulating of human arteries using lumped model and probing constriction in femoral and carotid arteries
, Article American Journal of Applied Sciences ; Volume 6, Issue 5 , 2009 , Pages 834-842 ; 15469239 (ISSN) ; Ghasemalizadeh, O ; Firoozabadi, B ; Sharif University of Technology
2009
Abstract
Problem statement: Modeling Human cardiovascular system was always an important issue from long past because by doing such modeling, investigation in cardiovascular system and its abnormities would be simpler. One of the most effective ways to do such modeling is using lumped method (Electrical analogy). Approach: Lumped method was used for simulating a complete model in this approach. A 36-vessel model was chosen to make equivalent circuit of lumped method from it. This complicated circuit includes equivalent segment for arteries, pulmonary, atrium, left and right ventricles. Furthermore, in this complex circuit some additional points were considered to improve this method. Some of the most...
Healthy and diseasedin vitromodels of vascular systems
, Article Lab on a Chip ; Volume 21, Issue 4 , 2021 , Pages 641-659 ; 14730197 (ISSN) ; Mallone, A ; Nasrollahi, F ; Ostrovidov, S ; Nasiri, R ; Mahmoodi, M ; Haghniaz, R ; Baidya, A ; Salek, M. M ; Darabi, M. A ; Orive, G ; Shamloo, A ; Dokmeci, M. R ; Ahadian, S ; Khademhosseini, A ; Sharif University of Technology
Royal Society of Chemistry
2021
Abstract
Irregular hemodynamics affects the progression of various vascular diseases, such atherosclerosis or aneurysms. Despite the extensive hemodynamics studies on animal models, the inter-species differences between humans and animals hamper the translation of such findings. Recent advances in vascular tissue engineering and the suitability ofin vitromodels for interim analysis have increased the use ofin vitrohuman vascular tissue models. Although the effect of flow on endothelial cell (EC) pathophysiology and EC-flow interactions have been vastly studied in two-dimensional systems, they cannot be used to understand the effect of other micro- and macro-environmental parameters associated with...
Beat pressure and comparing it with ascending aorta pressure in normal and abnormal conditions
, Article 4th European Conference of the International Federation for Medical and Biological Engineering, ECIFMBE 2008, Antwerp, 23 November 2008 through 27 November 2008 ; Volume 22 , 2008 , Pages 276-285 ; 16800737 (ISSN); 9783540892076 (ISBN) ; Mirzaee, M. R ; Firoozabadi, B ; Sajadi, B ; Zolfonoon, A ; Sharif University of Technology
2008
Abstract
Lumped method (Electrical analogy) is a quick and easy way to model human cardiovascular system. In this paper Lumped method is used for simulating a complete model. It describes a 36-vessel model and cardiac system of human body with details that could show hydrodynamic parameters of cardiovascular system. Also this paper includes modeling of pulmonary, atrium, left and right ventricles with their equivalent circuits. Exact modeling of right and left ventricles pressure with division of ascending aorta into 27 segments increases the accuracy of our simulation. In this paper we show that a calculated pressure for aorta from our complex circuit is near to measured pressure by using advanced...
Exact modeling of cardiovascular system using lumped method
, Article 2008 International Conference on Bioinformatics and Computational Biology, BIOCOMP 2008, Las Vegas, NV, 14 July 2008 through 17 July 2008 ; 2008 , Pages 408-417 ; 1601320558 (ISBN); 9781601320551 (ISBN) ; Mirzaee, M. R ; Firoozabadi, B ; Hassani, K ; Sharif University of Technology
2008
Abstract
Electrical analogy (Lumped method) is an easy way to model human cardiovascular system. In this paper Lumped method is used for simulating a complete model. It describes a 36-vessel model and cardiac system of human body with details that could show hydrodynamic parameters of cardiovascular system. Also this paper includes modeling of pulmonary, atrium, left and right ventricles with their equivalent circuits. Exact modeling of right and left ventricles pressure increases the accuracy of our simulation. In this paper we show that a calculated pressure for aorta from our complex circuit is near to measured pressure by using advanced medical instruments
An age index for vascular system based on photoplethysmogram pulse contour analysis
, Article IFMBE Proceedings ; Volume 21 IFMBE, Issue 1 , 2008 , Pages 125-128 ; 16800737 (ISSN); 9783540691389 (ISBN) ; Mohd Ali, M. A ; Zahedi, E ; Sharif University of Technology
Springer Verlag
2008
Abstract
An approach based pulse on contour analysis is proposed for the development of an aging index for the vascular system. The approach is non-invasive, using photoplethysmography (PPG), which is in wide clinical use. A probe is applied to the subject's finger-tip to provide a measure of the pulse waveform. The measured waveforms are filtered, digitized and post-processed. Individual pulses are extracted and the best pulse was selected by using the best pulse selection algorithm. Pulse contour analysis is then performed with specially formulated PPG fitness equation. Results of measurements taken from 72 subjects are reported. The age range of the subjects was from 19 to 68 years, all of them...
Effects of physical exercise on the photoplethysmogram waveform
, Article 2007 5th Student Conference on Research and Development, SCORED, Selangor, 11 December 2007 through 12 December 2007 ; 2007 ; 1424414709 (ISBN); 9781424414703 (ISBN) ; Zahedi, E ; Mohd Ali, M. A ; Sharif University of Technology
2007
Abstract
Photoplethysmography is a non-invasive method which is suitable to estimate vascular compliance. Photoplethysmogram (PPG) waveform has been used to evaluate vascular characteristic changes due to exercise. Quantification of the primary and secondary peak position is of interest as a potential objective, individualized measure of the level of exercise that a subject has achieved with respect to a baseline status, prior to the beginning of the exercise session. The modified bicycle ergonomic protocol was selected for this experiment. Two different signal processing methods were employed in processing the PPG waveform to characterize its changes through a single parameter. Both, the visual...
Estimation of mean radius, length and density of microvasculature using diffusion and perfusion MRI
, Article Scientia Iranica ; Volume 13, Issue 4 , 2006 , Pages 348-354 ; 10263098 (ISSN) ; Jahed, M ; Chopp, M ; Mireshghi, A ; Sharif University of Technology
Sharif University of Technology
2006
Abstract
In theory, diffusion and perfusion information in MRI maps can be combined to yield morphological information, such as capillary density, volume and possibly capillary plasma velocity. This paper suggests a new method for determination of mean radius, length and capillary density in normal regions using diffusion and perfusion MRI. Mean Transit Time (MTT), Cerebral Blood Volume (CBV), Apparent Diffusion Coefficient (ADC), pseudo-diffusion coefficient (D*) and ΔR2 and ΔR2* values were utilized to calculate mean radius, length and capillary density. To verify the proposed theory, a special protocol was designed and tested on normal regions of a male Wistar rat using obtained functions. Mean...