Loading...
Search for: fault-diagnosis
0.014 seconds
Total 49 records

    Quick diagnosis of short circuit faults in cascaded H-bridge multilevel inverters using FPGA

    , Article Journal of Power Electronics ; Volume 17, Issue 1 , 2017 , Pages 56-66 ; 15982092 (ISSN) Ouni, S ; Zolghadri, M. R ; Rodriguez, J ; Shahbazi, M ; Oraee, H ; Lezana, P ; Schmeisser, A. U ; Sharif University of Technology
    Korean Institute of Power Electronics  2017
    Abstract
    Fast and accurate fault detection is the primary step and one of the most important tasks in fault tolerant converters. In this paper, a fast and simple method is proposed to detect and diagnosis the faulty cell in a cascaded H-bridge multilevel inverter under a short circuit fault. In this method, the reference voltage is calculated using switching control pulses and DC-Link voltages. The comparison result of the output voltage and the reference voltage is used in conjunction with active cell pulses to detect the faulty cell. To achieve this goal, the cell which is active when the Fault signal turns to “0” is detected as the faulty cell. Furthermore, consideration of generating the active... 

    IGBT open-circuit fault diagnosis in a Quasi-Z-source inverter

    , Article IEEE Transactions on Industrial Electronics ; Volume 66, Issue 4 , 2019 , Pages 2847-2856 ; 02780046 (ISSN) Yaghoubi, M ; Shokrollahi Moghani, J ; Noroozi, N ; Zolghadri, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2018
    Abstract
    In this paper, a fast and practical method is proposed for open-circuit (OC) fault diagnosis (FD) in a three-phase quasi-Z-source inverter (q-ZSI). Compared to the existing fast OC FD techniques in three-phase voltage-source inverters (VSIs), this method is more cost-effective since no ultra-fast processor or high-speed measurement is required. Additionally, the method is independent of the load condition. The proposed method is only applicable to Z-source family inverters and is based on observing the effect of shoot-through (SH) intervals on the system variables during switching periods. The proposed algorithm includes two consecutive stages: OC detection and fault location identification.... 

    A robust short-circuit fault diagnosis for high voltage DC power supply based on multisensor data fusion

    , Article 10th International Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2019, 12 February 2019 through 14 February 2019 ; 2019 , Pages 659-664 ; 9781538692547 (ISBN) Ayoubi, R ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Short-circuit fault (SCF) detection is mandatory in a high voltage DC power supply (HVPS) to prevent fatal damage. The majority of converters employ a single sensor to detect the SCF. This attribute increases the interference vulnerability of the fault detection (FD) system in the presence of noise. Therefore, miss detections and false alarms are possible to occur. Miss detections and false alarms are harmful catastrophes in most applications. A commonly used method to suppress the noise impacts is using a low-bandwidth low-pass filter. However, the use of the low-bandwidth low-pass filter reduces the speed of FD due to the filter delay. This paper proposes a fast FD algorithm based on... 

    A fault-tolerant strategy for three-phase dual active bridge converter

    , Article 10th International Power Electronics, Drive Systems and Technologies Conference, PEDSTC 2019, 12 February 2019 through 14 February 2019 ; 2019 , Pages 253-258 ; 9781538692547 (ISBN) Davoodi, A ; Noroozi, N ; Zolghadri, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Due to several advantages, three-phase Dual Active Bridge (DAB) converter is widely used in numerous applications nowadays. On the other hand, this converter is very vulnerable to Transistor Open-Circuit Fault (TOCF). Therefore, a fault-tolerant (FT) scheme has been proposed in this paper to solve the problem. First, normal and faulty conditions are investigated, and according to the results, a fault-diagnosis (FD) approach is introduced. Using the outcomes of FD unit, a new post-fault strategy is proposed for the converter. The FD method is based on the DC component of transformer phase currents, and the basis of FT technique is shedding the faulty phase. Some benefits of the proposed... 

    Twin growth in RF window ceramic as a criterion for the response time of protection system in high power vacuum tubes

    , Article 2019 International Vacuum Electronics Conference, IVEC 2019, 28 April 2019 through 1 May 2019 ; 2019 ; 9781538675342 (ISBN) Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    The ceramic fracture in output RF window is one of the most important failure factors in high power microwave sources. Fast protection systems are used to protect the source. The methods for determining the required protection response time are conservative and rough. In this paper, an investigation is presented about the twin growth in the ceramic of RF window in faulty condition. It is shown that the twin growth in ceramic can be a reliable figure of merit for the response time calculation of the microwave source protection system  

    A Vacuum arc diagnosis method for the high voltage power supply of vacuum tubes

    , Article 2019 International Vacuum Electronics Conference, IVEC 2019, 28 April 2019 through 1 May 2019 ; 2019 ; 9781538675342 (ISBN) Ayoubi, R ; Rahmanian, M ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Vacuum tubes are widely used for various applications. These vacuum tubes are supplied by high voltage power supplies. The amount of delivered energy from the high voltage power supply to the vacuum tube is an important issue during the vacuum arc in the tube. The protection mechanism consists of a shunt crowbar which diverts the fault current from the tube to itself as a parallel path. Detection of the vacuum arc is crucial and only one sensor is usually employed to detect the vacuum arc. This characteristic intensifies the interference susceptibility of the vacuum arc diagnosis system in a noisy environment. As a result of the noise, the arc detection system can report false alarms. False... 

    IGBT Open-circuit fault diagnosis in a quasi-z-source inverter

    , Article IEEE Transactions on Industrial Electronics ; Volume 66, Issue 4 , 2019 , Pages 2847-2856 ; 02780046 (ISSN) Yaghoubi, M ; Moghani, J. S ; Noroozi, N ; Zolghadri, M. R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    In this paper, a fast and practical method is proposed for open-circuit (OC) fault diagnosis (FD) in a three-phase quasi-Z-source inverter (q-ZSI). Compared with the existing fast OC FD techniques in three-phase voltage source inverters, this method is more cost-effective since no ultrafast processor or high-speed measurement is required. Additionally, the method is independent of the load condition. The proposed method is only applicable to Z-source family inverters and is based on observing the effect of shoot-through intervals on the system variables during switching periods. The proposed algorithm includes two consecutive stages: OC detection and fault location identification. When both... 

    High-Performance Fault Diagnosis Schemes for Efficient Hash Algorithm BLAKE

    , Article 10th IEEE Latin American Symposium on Circuits and Systems, LASCAS 2019, 24 February 2019 through 27 February 2019 ; 2019 , Pages 201-204 ; 9781728104522 (ISBN) Mozaffari Kermani, M ; Bayat Sarmadi, S ; Ackie, A. B ; Azarderakhsh, R ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Augmenting the security of cryptographic algorithms by protecting them against side-channel active attacks (and natural faults) is essential in cryptographic engineering. BLAKE algorithm is an efficient hash function which has been developed based on Bernstein's ChaCha stream cipher. Because of the fact that Google has chosen ChaCha along with Bernstein's Poly1305 message authentication code as a replacement for RC4 in TLS for Internet security, BLAKE's implementation is of paramount importance. In this paper, we present high-performance fault detection schemes for BLAKE. Specifically, for the round function, two fault diagnosis approaches are developed and analyzed in terms of error... 

    A Fast vacuum arc detection method based on the neural network data fusion algorithm for the high-voltage dc power supply of vacuum tubes

    , Article IEEE Transactions on Plasma Science ; 2020 Ayoubi, R ; Kaboli, S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    Vacuum arc is one of the most important failure factors of the vacuum tubes. The amount of delivered energy from the high-voltage dc power supply to the vacuum tube is an important issue during the vacuum arc in the tube. Vacuum arc acts as a short-circuit fault (SCF) at the power supply output. The majority of converters use a single current sensor to measure only the converter output current for detecting the SCF. However, the sensor may provide unreliable data because of the noise effect. Application of a low-pass filter reduces the noise effect. Regarding the delay of the low-pass filter, the interval of arc detection increases and more energy is delivered to the tube. In this article, a... 

    Online static/dynamic eccentricity fault diagnosis in inverter-driven electrical machines using resolver signals

    , Article IEEE Transactions on Energy Conversion ; Volume 35, Issue 4 , May , 2020 , Pages 1973-1980 Lasjerdi, H ; Nasiri Gheidari, Z ; Tootoonchian, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    Inverter driven electrical machines need resolver for position estimation and efficient electronic commutations. In this paper, the resolver signals are also used for the purpose of mechanical fault diagnosis. Therefore, a comprehensive procedure based on winding function (WF) method is presented to propose a noninvasive index to identify the mechanical fault's type (static/dynamic eccentricity) and even its percentage. In this regard, once the resolver signals are measured and saved in health condition. Then, during the operation of the motor, calculating the proposed index using the healthy and faulty signals leads to predict the fault type and its percentage. The success of the proposed... 

    A new fault detection method for modular multilevel converter semiconductor power switches

    , Article 41st Annual Conference of the IEEE Industrial Electronics Society, 9 November 2015 through 12 November 2015 ; 2015 , Pages 50-55 ; 9781479917624 (ISBN) Haghnazari, S ; Shahbazi, M ; Zolghadri, M. R ; IEEE Industrial Electonics Society (IES) ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc 
    Abstract
    This paper proposes a new fault detection method for the modular multilevel converter (MMC) semiconductor power switches. While in common MMCs, the modules capacitor voltages are measured directly for control purposes, in this paper voltage measurement point changes to module output terminal improving fault diagnosis ability. Based on this measurement reconfiguration, a novel fault detection algorithm is designed for MMCs semiconductor power switches. The open circuit and short circuit faultsare detected based on unconformity between modules output voltage and switching signals. Simulations results confirm accurate and fast operation of the proposed algorithm in faulty module diagnosis.... 

    Flooding and dehydration diagnosis in a polymer electrolyte membrane fuel cell stack using an experimental adaptive neuro-fuzzy inference system

    , Article International Journal of Hydrogen Energy ; Volume 47, Issue 81 , 2022 , Pages 34628-34639 ; 03603199 (ISSN) Khanafari, A ; Alasty, A ; Kermani, M. J ; Asghari, S ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Today the need for fault diagnosis in polymer electrolyte membrane fuel cells (PEMFCs) is felt more than ever to increase the useful life and durability of the cell. The present study proposes an indirect in-situ experimental-based algorithm for diagnosing the moisture content issues in a three-cell stack. Three adaptive neuro-fuzzy inference systems (ANFIS) approximate the system outputs (cells voltages, cathodic and anodic pressure drop) in normal conditions. The values of Pearson's correlation coefficients (0.998, 0.983, and 0.995 for outputs, respectively) show the high quality of the modeling. In unknown operating conditions, the residuals of experimental and ANFIS values are compared... 

    Fault diagnosis of a centrifugal pump by vibration analysis

    , Article Proceedings of the 7th Biennial Conference on Engineering Systems Design and Analysis - 2004, Manchester, 19 July 2004 through 22 July 2004 ; Volume 3 , 2004 , Pages 221-226 ; 0791841731 (ISBN); 9780791841730 (ISBN) Behzad, M ; Bastami, A. R ; Maassoumian, M ; Sharif University of Technology
    American Society of Mechanical Engineers  2004
    Abstract
    This paper gives the final Solution for vibration reduction in a centrifugal pump. Vibration measurement in different conditions has been carried out in order to find the main reason for excessive vibration of the pumps. In the first stage several parameters including cavitation, not working in the pump design condition and mechanical and electrical faults assumed to be the reason for the pump vibration. By vibration analysis it is found that the major reason for the pump vibration is working in off design conditions. More over dissolved air in the suction fluid can possibly cause two-phase flow leading to the pump vibration. For solving both problems considering pump performance curves it... 

    Impacts of fault diagnosis schemes on distribution system reliability

    , Article IEEE Transactions on Smart Grid ; Vol. 3, issue. 2 , 2012 , p. 720-727 ; ISSN: 19493053 Kazemi, S ; Lehtonen, M ; Fotuhi-Firuzabad, M ; Sharif University of Technology
    Abstract
    Design and development of fault diagnosis schemes (FDS) for electric power distribution systems are major steps in realizing the self-healing function of a smart distribution grid. The application of the FDS in the electric power distribution systems is mainly aimed at precise detecting and locating of the deteriorated components, thereby enhancing the quality and reliability of the electric power delivered to the customers. The impacts of two types of the FDS on distribution system reliability are compared and presented in this paper. The first type is a representative of the FDS which diagnoses the deteriorated components after their failing. However, the second type is a representative of... 

    Experimental investigation on the fault diagnosis of permanent magnet DC electromotors

    , Article Insight: Non-Destructive Testing and Condition Monitoring ; Volume 55, Issue 8 , August , 2013 , Pages 422-427 ; ISSN: 13542575 Behzad, M ; Ebrahimi, A ; Heydari, M ; Asadi, M ; Alasti, A ; Sharif University of Technology
    Abstract
    In this paper, an algorithm for fault diagnosis of permanent magnet DC electromotors.has been investigated, based on vibration and electrical current monitoring. Several permanent magnet DC electromotors.with previously determined faults have been prepared and the vibration, current and speed data have been measured. The relationship between certain related measured data and faults has been determined. A fault diagnosis algorithm has been developed in this research based on these relationships. This algorithm can be used in mass production lines for quality control  

    On-line fault detection and isolation (FDI) for the exhaust path of a turbocharged SI engine

    , Article ASME 2013 Dynamic Systems and Control Conference, DSCC 2013 ; Vol. 1 , 2013 ; ISBN: 9780791856123 Salehi, R ; Shahbakhti M ; Alasty, A ; Vossoughi, G ; Sharif University of Technology
    Abstract
    Detection and isolation of faults in the exhaust gas path of a turbocharged spark ignition (SI) engine is an essential part of the engine control unit (ECU) strategies to minimize exhaust emission and ensure safe operation of a turbocharger. This paper proposes a novel physics-based strategy to detect and isolate an exhaust manifold leakage and a closed-stuck wastegate fault. The strategy is based on a globally optimal parameter estimation algorithm which detects an effective hole area in the exhaust manifold. The estimation algorithm requires prediction of the exhaust manifold's input and output flows. The input flow is predicted by a nonlinear Luenberger observer which is analytically... 

    Circuit-breaker automated failure tracking based on coil current signature

    , Article IEEE Transactions on Power Delivery ; Vol. 29, issue. 1 , February , 2014 , pp. 283-290 ; ISSN: 08858977 Razi-Kazemi, A. A ; Vakilian, M ; Niayesh, K ; Lehtonen, M ; Sharif University of Technology
    Abstract
    The online condition assessment of circuit breakers (CBs) has been increasingly requested by power utilities in recent years. Trip and close coil current (CC) signature is an effective and noninvasive parameter in CB online condition monitoring. This paper gives an insight into the impacts of the various failures on the coil current waveform, as well as on the CB operation time. The failures and their causes are categorized based on the outcome of these investigations. Finally, a new algorithm using trip/close CC is proposed to detect the mode and cause of CB incipient failures. In this study, the CC patterns are acquired by measurements carried out on (healthy and faulty) CBs of 72.5-kV and... 

    Reliable concurrent error detection architectures for extended euclidean-based division over (2m)

    , Article IEEE Transactions on Very Large Scale Integration (VLSI) Systems ; Vol. 22, Issue. 5 , 2014 , pp. 995-1003 Mozaffari-Kermani, M ; Azarderakhsh, R ; Lee, C. Y ; Bayat-Sarmadi, S ; Sharif University of Technology
    Abstract
    The extended Euclidean algorithm (EEA) is an important scheme for performing the division operation in finite fields. Many sensitive and security-constrained applications such as those using the elliptic curve cryptography for establishing key agreement schemes, augmented encryption approaches, and digital signature algorithms utilize this operation in their structures. Although much study is performed to realize the EEA in hardware efficiently, research on its reliable implementations needs to be done to achieve fault-immune reliable structures. In this regard, this paper presents a new concurrent error detection (CED) scheme to provide reliability for the aforementioned sensitive and... 

    Application of synchronised phasor measurements to wide-area fault diagnosis and location

    , Article IET Generation, Transmission and Distribution ; Vol. 8, issue. 4 , 2014 , pp. 716-729 ; ISSN: 17518687 Salehi-Dobakhshari, A ; Ranjbar, A. M ; Sharif University of Technology
    Abstract
    This study introduces a novel approach to power system fault diagnosis by synchronised phasor measurements. Conventionally, faults are diagnosed through the status of protective relays and circuit breakers which are activated following a fault. However, the hidden failures of the protection system has itself often been among the main suspects of partial or widespread blackouts. This study proposes an alternative fault diagnosis approach independent of the function of the protection system. An analytical method is introduced for power system fault diagnosis using dispersed synchronised measurements and bus impedance matrix (Zbus). Fault inception is first detected by local phasor measurement... 

    Open-and short-circuit switch fault diagnosis for nonisolated DC-DC converters using field programmable gate array

    , Article IEEE Transactions on Industrial Electronics ; Volume 60, Issue 9 , October , 2013 , Pages 4136-4146 ; 02780046 (ISSN) Shahbazi, M ; Jamshidpour, E ; Poure, P ; Saadate, S ; Zolghadri, M. R ; Sharif University of Technology
    2013
    Abstract
    Fault detection (FD) in power electronic converters is necessary in embedded and safety critical applications to prevent further damage. Fast FD is a mandatory step in order to make a suitable response to a fault in one of the semiconductor devices. The aim of this study is to present a fast yet robust method for fault diagnosis in nonisolated dc-dc converters. FD is based on time and current criteria which observe the slope of the inductor current over the time. It is realized by using a hybrid structure via coordinated operation of two FD subsystems that work in parallel. No additional sensors, which increase system cost and reduce reliability, are required for this detection method. For...