Loading...
Search for: finite-element-analysis
0.01 seconds
Total 295 records

    Effect of intervertebral translational flexibilities on estimations of trunk muscle forces, kinematics, loads, and stability

    , Article Computer Methods in Biomechanics and Biomedical Engineering ; Volume 18, Issue 16 , Sep , 2015 , Pages 1760-1767 ; 10255842 (ISSN) Ghezelbash, F ; Arjmand, N ; Shirazi Adl, A ; Sharif University of Technology
    Taylor and Francis Ltd  2015
    Abstract
    Due to the complexity of the human spinal motion segments, the intervertebral joints are often simulated in the musculoskeletal trunk models as pivots thus allowing no translational degrees of freedom (DOFs). This work aims to investigate, for the first time, the effect of such widely used assumption on trunk muscle forces, spinal loads, kinematics, and stability during a number of static activities. To address this, the shear deformable beam elements used in our nonlinear finite element (OFE) musculoskeletal model of the trunk were either substantially stiffened in translational directions (SFE model) or replaced by hinge joints interconnected through rotational springs (HFE model). Results... 

    Dynamic analysis of laminated composite plates traversed by a moving mass based on a first-order theory

    , Article Composite Structures ; Volume 92, Issue 8 , 2010 , Pages 1865-1876 ; 02638223 (ISSN) Ghafoori, E ; Asghari, M ; Sharif University of Technology
    2010
    Abstract
    The dynamic response of angle-ply laminated composite plates traversed by a moving mass or a moving force is investigated. For this purpose, a finite element method based on the first-order shear deformation theory is used. Stationary and adaptive mesh techniques have been applied as two different meshing schemes. The adaptive mesh strategy is then used to avoid off-nodal position of moving mass. In this manner, the finite element mesh is continuously adapted to follow and comply with the path of moving mass. A Newmark direct integration method is employed to solve the equations of motion. Parametric study is directed to find out how different parameters like mass of the moving object as... 

    Joint edge detection and motion estimation of cardiac MR image sequence by a phase field method

    , Article Computers in Biology and Medicine ; Volume 40, Issue 1 , 2010 , Pages 21-28 ; 00104825 (ISSN) Eslami, A ; Jahed, M ; Preusser, T ; Sharif University of Technology
    Abstract
    In this paper a variational framework for joint segmentation and motion estimation is employed for inspecting heart in Cine MRI sequences. A functional including Mumford-Shah segmentation and optical flow based dense motion estimation is approximated using the phase-field technique. The minimizer of the functional provides an optimum motion field and edge set by considering both spatial and temporal discontinuities. Exploiting calculus of variation principles, multiple partial differential equations associated with the Euler-Lagrange equations of the functional are extracted, first. Next, the finite element method is used to discretize the resulting PDEs for numerical solution. Several... 

    Thermal residual stresses in silicon thin film solar cells under operational cyclic thermal loading: A finite element analysis

    , Article Solar Energy ; Volume 135 , 2016 , Pages 366-373 ; 0038092X (ISSN) Namvar, A ; Dehghany, M ; Sohrabpour, S ; Naghdabadi, R ; Sharif University of Technology
    Elsevier Ltd  2016
    Abstract
    In manufacturing amorphous silicon solar cells, thin films are deposited at high temperatures (200-400 °C) on a thick substrate using sputtering and plasma enhanced chemical vapor deposition (PECVD) methods. Since the thin films and substrate have different thermal expansion coefficients, cooling the system from deposition temperature to room temperature induces thermal residual stresses in both the films and substrate. In addition, these stresses, especially those having been induced in the amorphous silicon layer can change the carrier mobility and band gap energy of the silicon and consequently affect the solar cell efficiency. In this paper, a 2D finite element model is proposed to... 

    A regenerative approach towards recovering the mechanical properties of degenerated intervertebral discs: Genipin and platelet-rich plasma therapies

    , Article Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine ; Volume 231, Issue 2 , 2017 , Pages 127-137 ; 09544119 (ISSN) Nikkhoo, M ; Wang, J. L ; Abdollahi, M ; Hsu, Y. C ; Parnianpour, M ; Khalaf, K ; Sharif University of Technology
    SAGE Publications Ltd  2017
    Abstract
    Degenerative disc disease, associated with discrete structural changes in the peripheral annulus and vertebral endplate, is one of the most common pathological triggers of acute and chronic low back pain, significantly depreciating an individual's quality of life and instigating huge socioeconomic costs. Novel emerging therapeutic techniques are hence of great interest to both research and clinical communities alike. Exogenous crosslinking, such as Genipin, and platelet-rich plasma therapies have been recently demonstrated encouraging results for the repair and regeneration of degenerated discs, but there remains a knowledge gap regarding the quantitative degree of effectiveness and... 

    Hypersensitivity of trunk biomechanical model predictions to errors in image-based kinematics when using fully displacement-control techniques

    , Article Journal of Biomechanics ; Volume 84 , 2019 , Pages 161-171 ; 00219290 (ISSN) Eskandari, A. H ; Arjmand, N ; Shirazi Adl, A ; Farahmand, F ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    Recent advances in medical imaging techniques have allowed pure displacement-control trunk models to estimate spinal loads with no need to calculate muscle forces. Sensitivity of these models to the errors in post-imaging evaluation of displacements (reported to be ∼0.4–0.9° and 0.2–0.3 mm in vertebral displacements) has not yet been investigated. A Monte Carlo analysis was therefore used to assess the sensitivity of results in both musculoskeletal (MS) and passive finite element (FE) spine models to errors in measured displacements. Six static activities in upright standing, flexed, and extended postures were initially simulated using a force-control hybrid MS-FE model. Computed vertebral... 

    A stability-based model of a growing spine with adolescent idiopathic scoliosis: A combination of musculoskeletal and finite element approaches

    , Article Medical Engineering and Physics ; Volume 64 , 2019 , Pages 46-55 ; 13504533 (ISSN) Kamal, Z ; Rouhi, G ; Arjmand, N ; Adeeb, S ; Sharif University of Technology
    Elsevier Ltd  2019
    Abstract
    Using a combined musculoskeletal and finite element (FE) approach, this study aimed to evaluate stability-based muscle forces in a spine with adolescent idiopathic scoliosis (AIS) as compared to a normal spine; and subsequently, determine the effects of stress distribution on the growth plates (GPs) of the growing spine. For this purpose a nonlinear 3D FE model of one normal and one scoliotic thoracolumbar spine, consisting of GPs attached to rigid L1 to L4 vertebrae, were developed using computed tomography images coupled with a growth modulation using the Stokes’ model. Corresponding well with recent in-vivo and in-vitro studies, results of the models predicted intradiscal pressures at the... 

    Optimal riser design in sand casting process by topology optimization with SIMP method I: poisson approximation of nonlinear heat transfer equation

    , Article Structural and Multidisciplinary Optimization ; Volume 36, Issue 2 , 25 January , 2008 , Pages 193-202 ; 1615147X (ISSN) Tavakoli, R ; Davami, P ; Sharif University of Technology
    2008
    Abstract
    The optimal design of a casting feeding system is considered. The problem is formulated as the volume constrained topology optimization and is solved with the finite element analysis, explicit design sensitivity, and numerical optimization. In contrast to the traditional topology optimization where the objective function is defined on the design space, in the presented method, the design space is a subset of the complement of the objective function space. To accelerate optimization procedure, the nonlinear unsteady heat transfer equation is approximated with a Poisson-like equation. The feasibility of the presented method is supported with illustrative examples. © 2007 Springer-Verlag  

    Trunk biomechanics during maximum isometric axial torque exertions in upright standing

    , Article Clinical Biomechanics ; Volume 23, Issue 8 , 2008 , Pages 969-978 ; 02680033 (ISSN) Arjmand, N ; Shirazi Adl, A ; Parnianpour, M ; Sharif University of Technology
    2008
    Abstract
    Background: Activities involving axial trunk rotations/moments are common and are considered as risk factors for low back disorders. Previous biomechanical models have failed to accurately estimate the trunk maximal axial torque exertion. Moreover, the trunk stability under maximal torque exertions has not been investigated. Methods: A nonlinear thoracolumbar finite element model along with the Kinematics-driven approach is used to study biomechanics of maximal axial torque generation during upright standing posture. Detailed anatomy of trunk muscles with six distinct fascicles for each abdominal oblique muscle on each side is considered. While simulating an in vivo study of maximal axial... 

    Experimental and analytical model analysis of Babolsar's steel arch bridge

    , Article 3rd International Conference on Bridge Maintenance, Safety and Management - Bridge Maintenance, Safety, Management, Life-Cycle Performance and Cost, Porto, 16 July 2006 through 19 July 2006 ; 2006 , Pages 235-237 ; 0415403154 (ISBN); 9780415403153 (ISBN) Beygi, M. H. A ; Kazemi, M. T ; Lark, B ; Tabrizian, Z ; Sharif University of Technology
    Taylor and Francis/ Balkema  2006
    Abstract
    The paper presents the experimental and analytical model analysis of a steel-girder arch bridge. The field test is carried out by ambient vibration testing under traffic excitations. Both the peak picking method in the frequency domain and the stochastic subspace identification method in the time domain are used for the output-only model identification. A good agreement in identified frequencies has been found between the two methods. It is further demonstrated that the stochastic subspace method provides better mode shapes. The three-dimensional finite element models are constructed and an analytical model analysis is then performed to generate natural frequencies and mode shapes in the... 

    Search for critical loading condition of the spine-A meta analysis of a nonlinear viscoelastic finite element model

    , Article Computer Methods in Biomechanics and Biomedical Engineering ; Volume 8, Issue 5 , 2005 , Pages 323-330 ; 10255842 (ISSN) Wang, J. L ; Shirazi Adl, A ; Parnianpour, M ; Sharif University of Technology
    2005
    Abstract
    The relative vulnerability of spinal motion segments to different loading combinations remains unknown. The meta-analysis described here using the results of a validated L2-L3 nonlinear viscoelastic finite element model was designed to investigate the critical loading and its effect on the internal mechanics of the human lumbar spine. A Box-Behnken experimental design was used to design the magnitude of seven independent variables associated with loads, rotations and velocity of motion. Subsequently, an optimization method was used to find the primary and secondary variables that influence spine mechanical output related to facet forces, disc pressure, ligament forces, annulus matrix... 

    Enhanced singlet oxygen production under nanoconfinement using silica nanocomposites towards improving the photooxygenation’s conversion

    , Article Journal of Nanoparticle Research ; Volume 24, Issue 9 , 2022 ; 13880764 (ISSN) Tamtaji, M ; Kazemeini, M ; Sharif University of Technology
    Springer Science and Business Media B.V  2022
    Abstract
    In this contribution, the effect of physical immobilization of methylene blue (MB) into silica nanocomposites was investigated on the conversion and selectivity of the photooxygenation of anthracene and dihydroartemisinic acid (DHAA). Physically immobilized photocatalysts were synthesized through a developed Stöber method and were thoroughly characterized by UV–Vis, FTIR, XRD, XPS, SEM, TEM, HR-TEM, BET-BJH, and EDX analyses. Based on the TEM and UV–Vis results, it was determined that enhancement of the MB concentration as an organocatalyst for the Stöber reaction led to an increase in the size of the nanoparticles from 54 to 183 nm and a 21 nm blue shift in their UV–Vis spectra. Moreover,... 

    Manipulating failure mechanism of rapid prototyped scaffolds by changing nodal connectivity and geometry of the pores

    , Article Journal of Biomechanics ; Volume 45, Issue 16 , 2012 , Pages 2866-2875 ; 00219290 (ISSN) Amirkhani, S ; Bagheri, R ; Zehtab Yazdi, A ; Sharif University of Technology
    2012
    Abstract
    The performance of cellular solids in biomedical applications relies strongly on a detailed understanding of the effects of pore topology on mechanical properties. This study aims at characterizing the failure mechanism of scaffolds based on nodal connectivity (number of struts that meet in joints) and geometry of the pores. Plastic models of scaffolds having the same relative density but different cubic and trigonal unit cells were designed and then fabricated via three dimensional (3-D) printing. Unit cells were repeated in different arrangements in 3-D space. An in-situ imaging technique was utilized to study the progressive deformation of the scaffold models. Different nodal... 

    Nonlinear hierarchical multiscale modeling of cortical bone considering its nanoscale microstructure

    , Article Journal of Biomechanics ; Volume 42, Issue 10 , 2009 , Pages 1560-1565 ; 00219290 (ISSN) Ghanbari, J ; Naghdabadi, R ; Sharif University of Technology
    2009
    Abstract
    We have used a hierarchical multiscale modeling scheme for the analysis of cortical bone considering it as a nanocomposite. This scheme consists of definition of two boundary value problems, one for macroscale, and another for microscale. The coupling between these scales is done by using the homogenization technique. At every material point in which the constitutive model is needed, a microscale boundary value problem is defined using a macroscopic kinematical quantity and solved. Using the described scheme, we have studied elastic properties of cortical bone considering its nanoscale microstructural constituents with various mineral volume fractions. Since the microstructure of bone... 

    A state-of-the-art review of the fabrication and characteristics of titanium and its alloys for biomedical applications

    , Article Bio-Design and Manufacturing ; Volume 5, Issue 2 , 2022 , Pages 371-395 ; 20965524 (ISSN) Sarraf, M ; Rezvani Ghomi, E ; Alipour, S ; Ramakrishna, S ; Liana Sukiman, N ; Sharif University of Technology
    Springer  2022
    Abstract
    Abstract: Commercially pure titanium and titanium alloys have been among the most commonly used materials for biomedical applications since the 1950s. Due to the excellent mechanical tribological properties, corrosion resistance, biocompatibility, and antibacterial properties of titanium, it is getting much attention as a biomaterial for implants. Furthermore, titanium promotes osseointegration without any additional adhesives by physically bonding with the living bone at the implant site. These properties are crucial for producing high-strength metallic alloys for biomedical applications. Titanium alloys are manufactured into the three types of α, β, and α + β. The scientific and clinical...