Loading...
Search for: heart
0.007 seconds
Total 161 records

    Clinical validation of a smartphone-based handheld ECG device: A validation study

    , Article Critical Pathways in Cardiology ; Volume 21, Issue 4 , 2022 , Pages 165-171 ; 1535282X (ISSN) Ahmadi-Renani, S ; Gharebaghi, M ; Kamalian, E ; Hajghassem, H ; Ghanbari, A ; Karimi, A ; Mansoury, B ; Dayari, M. S ; Khatmi Nemati, M ; Karimi, A ; Zarghami, M. H ; Vasheghani Farahani, A ; Sharif University of Technology
    Lippincott Williams and Wilkins  2022
    Abstract
    Background: Remote cardiac monitoring and screening have already become an integral telemedicine component. The wide usage of several different wireless electrocardiography (ECG) devices warrants a validation study on their accuracy and reliability. Methods: Totally, 300 inpatients with the Nabz Hooshmand-1 handheld ECG device and the GE MAC 1200 ECG system (as the reference) were studied to check the accuracy of the devices in 1 and 6-limb lead performance. Simultaneous 10-second resting ECGs were assessed for the most common ECG parameters in lead I. Afterward, 6-lead ECGs (limb leads), were performed immediately and studied for their morphologies. Results: Of the 300 patients, 297 had... 

    Expansion Modeling of Coronary Stent for Selection of Optimized Stent

    , M.Sc. Thesis Sharif University of Technology Izadi Ramini, Elaheh (Author) ; Movahhedy, Mohammad Reza (Supervisor)
    Abstract
    Referring to mortality increasment having sprung from atherosclerosis, work on treatment of coronary heart disease seems to be necessary. Stent implementation is one of stenosis treatment. Stent deployment has been done during past two decades, but clinical evidence showed that because of some weakness in designing and implementing, restenosis occurs again. Material, structure and coating texture of stent are the designing criteria beside stent implementation importance. Thus a lot of activities have been done in this area to improve performance of these applications. Nowadays a lot of companies' researchers try the best to get better their products; consequently there is different types of... 

    Heart Motion Measurement and Prediction for Robotic Assisted Beating Heart Surgery

    , Ph.D. Dissertation Sharif University of Technology Mansouri, Saeed (Author) ; Farahmand, Farzam (Supervisor) ; Vossoughi, Gholamreza (Supervisor)
    Abstract
    An essential requirement for performing robotic assisted surgery on a freely beating heart is a prediction algorithm which can estimate the future heart trajectory with a high accuracy in a long horizon. The main objective of this research was measurement and prediction of the heart motion for robotic assisted beating heart surgery. In this study, first the feasibility of a stereo infrared tracking system for measuring the free beating heart motion was investigated by experiments on a heart motion simulator. Simulator experiments revealed a high tracking accuracy when the capturing times were synchronized and the tracker pointed at the target from an appropriate distance.Then, the heart... 

    Bayesian denoising framework of phonocardiogram based on a new dynamical model

    , Article IRBM ; Volume 34, Issue 3 , 2013 , Pages 214-225 ; 19590318 (ISSN) Almasi, A ; Shamsollahi, M. B ; Senhadji, L ; Sharif University of Technology
    2013
    Abstract
    In this paper, we introduce a model-based Bayesian denoising framework for phonocardiogram (PCG) signals. The denoising framework is founded on a new dynamical model for PCG, which is capable of generating realistic synthetic PCG signals. The introduced dynamical model is based on PCG morphology and is inspired by electrocardiogram (ECG) dynamical model proposed by McSharry et al. and can represent various morphologies of normal PCG signals. The extended Kalman smoother (EKS) is the Bayesian filter that is used in this study. In order to facilitate the adaptation of the denoising framework to each input PCG signal, the parameters are selected automatically from the input signal itself. This... 

    Control tuning of a اeart motion tracking system in off-pump heart surgery

    , Article 5th RSI International Conference on Robotics and Mechatronics, IcRoM 2017, 25 October 2017 through 27 October 2017 ; 2018 , Pages 445-450 ; 9781538657034 (ISBN) Rahmati, Z ; Behzadipour, S ; Sharif University of Technology
    Abstract
    Design, implementation and experimental evaluation of a classic PID, and a modern Generalized Predictive Control (GPC) for an off-pump heart tracking system were carried out. Following the design and simulation analysis of the controllers, experimental evaluation was conducted on the slave robot of SINA tele-operational surgical system. Results revealed that considering the volatile high-frequency/speed pattern of heart motion, the agility of the controlled system is the most influential factor on its performance. With this in mind, unlike the Ziegler-Nichols-based tuned PID with emphasis on steady-state condition, the PID control with more transient behavior showed a superior performance.... 

    Control tuning of a اeart motion tracking system in off-pump heart surgery

    , Article 5th RSI International Conference on Robotics and Mechatronics, IcRoM 2017, 25 October 2017 through 27 October 2017 ; 2018 , Pages 445-450 ; 9781538657034 (ISBN) Rahmati, Z ; Behzadipour, S ; Sharif University of Technology
    Elsevier  2018
    Abstract
    Design, implementation and experimental evaluation of a classic PID, and a modern Generalized Predictive Control (GPC) for an off-pump heart tracking system were carried out. Following the design and simulation analysis of the controllers, experimental evaluation was conducted on the slave robot of SINA tele-operational surgical system. Results revealed that considering the volatile high-frequency/speed pattern of heart motion, the agility of the controlled system is the most influential factor on its performance. With this in mind, unlike the Ziegler-Nichols-based tuned PID with emphasis on steady-state condition, the PID control with more transient behavior showed a superior performance.... 

    Statistical feature embedding for heart sound classification

    , Article Journal of Electrical Engineering ; Volume 70, Issue 4 , 2019 , Pages 259-272 ; 13353632 (ISSN) Adiban, M ; Babaali, B ; Shehnepoor, S ; Sharif University of Technology
    De Gruyter Open Ltd  2019
    Abstract
    Cardiovascular Disease (CVD) is considered as one of the principal causes of death in the world. Over recent years, this field of study has attracted researchers' attention to investigate heart sounds' patterns for disease diagnostics. In this study, an approach is proposed for normal/abnormal heart sound classification on the Physionet challenge 2016 dataset. For the first time, a fixed length feature vector; called i-vector; is extracted from each heart sound using Mel Frequency Cepstral Coefficient (MFCC) features. Afterwards, Principal Component Analysis (PCA) transform and Variational Autoencoder (VAE) are applied on the i-vector to achieve dimension reduction. Eventually, the reduced... 

    A comprehensive multimodality heart motion prediction algorithm for robotic-assisted beating heart surgery

    , Article International Journal of Medical Robotics and Computer Assisted Surgery ; Volume 15, Issue 2 , 2019 ; 14785951 (ISSN) Mansouri, S ; Farahmand, F ; Vossoughi, G ; Alizadeh Ghavidel, A ; Sharif University of Technology
    John Wiley and Sons Ltd  2019
    Abstract
    Background: An essential requirement for performing robotic-assisted surgery on a freely beating heart is a prediction algorithm that can estimate the future heart trajectory. Method: Heart motion, respiratory volume (RV) and electrocardiogram (ECG) signal were measured from two dogs during thoracotomy surgery. A comprehensive multimodality prediction algorithm was developed based on the multivariate autoregressive model to incorporate the heart trajectory and cardiorespiratory data with multiple inherent measurement rates explicitly. Results: Experimental results indicated strong relationships between the dominant frequencies of heart motion with RV and ECG. The prediction algorithm... 

    Computational investigation of stenosis in curvature of coronary artery within both dynamic and static models

    , Article Computer Methods and Programs in Biomedicine ; Volume 185 , 2020 Biglarian, M ; Momeni Larimi, M ; Hassanzadeh Afrouzi, H ; Moshfegh, A ; Toghraie, D ; Javadzadegan, A ; Rostami, S ; Sharif University of Technology
    Elsevier Ireland Ltd  2020
    Abstract
    Background and Objective: Blood flow variation during cardiac cycle is the main mechanism of atherosclerotic development which is dependent on. Methods: The present work mainly tends to investigate stenosis effect in dynamic curvature of coronary artery. This paper presents numerical investigations on wall shear stress profiles in three-dimensional pulsatile flow through curved stenotic coronary arteries for both static and dynamic model. In order to do so, three-dimensional models related to the curved arteries with two degrees of stenosis (30% and 50%). Results: Lower amount of wall shear stress is found near the inner wall of artery distal to the plaque region (stenosis) and in both... 

    Applicability of adaptive noise cancellation to fetal heart rate detection using photoplethysmography

    , Article Computers in Biology and Medicine ; Volume 38, Issue 1 , 2008 , Pages 31-41 ; 00104825 (ISSN) Zahedi, E ; Beng, G. K ; Sharif University of Technology
    2008
    Abstract
    In this paper, an approach based on adaptive noise cancellation (ANC) is evaluated for extraction of the fetal heart rate using photoplethysmographic signals from the maternal abdomen. A simple optical model is proposed in which the maternal and fetal blood pulsations result in emulated signals where the lower SNR limit (fetal to maternal) is - 25 dB. It is shown that a recursive least-squares algorithm is capable of extracting the peaks of the fetal PPG from these signals, for typical values of maternal and fetal tissues. © 2007 Elsevier Ltd. All rights reserved  

    Design and simulation of a life detection system based on detection of the heart beat using doppler frequency

    , Article 6th IEEE International Symposium on Signal Processing and Information Technology, ISSPIT 2006, Vancouver, BC, 27 August 2006 through 30 August 2006 ; 2006 , Pages 685-690 ; 0780397541 (ISBN); 9780780397545 (ISBN) Izadi, A ; Ghatan, Z ; Vosoughi Vahdat, B ; Farzaneh, F ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2006
    Abstract
    The ability and how to use a microwave life-detection system to search for the humans buried under earthquake rubble or laid behind various barriers has been investigated. Based on the behavior of a human under multiple layers of barriers and the detection capability of the microwave tools a system has been proposed. This system operating at 1150 MHz can remotely detect the movement of the heart of the trapped alive people. The operation principle is based on detection of the Doppler frequency shift of the electromagnetic wave reflected from the periodic moving part of a living human body such as the heart. In this paper, various parts of a microwave life-detection system such as patch... 

    Beating-heart robotic surgery using bilateral impedance control: Theory and experiments

    , Article Biomedical Signal Processing and Control ; Volume 45 , 2018 , Pages 256-266 ; 17468094 (ISSN) Sharifi, M ; Salarieh, H ; Behzadipour, S ; Tavakoli, M ; Sharif University of Technology
    Elsevier Ltd  2018
    Abstract
    A bilateral impedance controller is presented to enable robot-assisted surgery of a beating heart. For this purpose, two desired impedance models are designed and realized for the master and slave robots interacting with the operator (surgeon) and the environment (heart tissue), respectively. The impedance models are designed such that (a) the slave robot complies with the oscillatory motion of the beating heart and (b) the surgeon perceives the non-oscillatory portion of the slave/heart contact force at the master robot implying arrested-heart surgery. These performance goals are achieved via appropriate adjustment of the impedance model parameters without any measurement or estimation of... 

    Type V collagen in scar tissue regulates the size of scar after heart injury

    , Article Cell ; Volume 182, Issue 3 , 2020 , Pages 545-562.e23 Yokota, T ; McCourt, J ; Ma, F ; Ren, S ; Li, S ; Kim, T. H ; Kurmangaliyev, Y. Z ; Nasiri, R ; Ahadian, S ; Nguyen, T ; Tan, X. H. M ; Zhou, Y ; Wu, R ; Rodriguez, A ; Cohn, W ; Wang, Y ; Whitelegge, J ; Ryazantsev, S ; Khademhosseini, A ; Teitell, M. A ; Chiou, P. Y ; Birk, D. E ; Rowat, A. C ; Crosbie, R. H ; Pellegrini, M ; Seldin, M ; Lusis, A. J ; Deb, A ; Sharif University of Technology
    Cell Press  2020
    Abstract
    Scar tissue size following myocardial infarction is an independent predictor of cardiovascular outcomes, yet little is known about factors regulating scar size. We demonstrate that collagen V, a minor constituent of heart scars, regulates the size of heart scars after ischemic injury. Depletion of collagen V led to a paradoxical increase in post-infarction scar size with worsening of heart function. A systems genetics approach across 100 in-bred strains of mice demonstrated that collagen V is a critical driver of postinjury heart function. We show that collagen V deficiency alters the mechanical properties of scar tissue, and altered reciprocal feedback between matrix and cells induces... 

    Design and Manufacturing of Left Ventricular Assist Device for Patients Undergoing Cardiac Surgery

    , M.Sc. Thesis Sharif University of Technology Ahmadidoust, Ehsan (Author) ; Ahmadian, Mohammad Taghi (Supervisor) ; Firouzbakhsh, Keikhosrow (Supervisor)
    Abstract
    The heart is a powerful muscle whose primary function is to pump blood into the body. many cardiac patients reach a stage that can no longer be kept function of their heart to a satisfactory level by using medication thus doctors undergo surgery. The common problem occurs to most patients undergoing cardiac surgery is that after the surgery, the patient's heart during a short period of time is unable to supply blood with the flow rate and pressure required for all organs, especially the end organs of the body. In this conditions, ventricular assist device help the patients. These devices are used parallel with patient’s heart and supply the large portion of blood that patient’s body needs.... 

    Investigation the Effect of Conductive Scaffolds on Regeneration of the Heart Tissue

    , M.Sc. Thesis Sharif University of Technology Moradpour, Kayvan (Author) ; Vossoughi, Manoochehr (Supervisor) ; Ahmadi Tafti, Hossein (Supervisor)
    Abstract
    Cardiovascular diseases, especially coronary artery disease and coronary heart disease, are the leading cause of death in human communities. After myocardial infarction, known as heart attack, the flow of oxygen to the heart muscle cells is disrupted. It causes the death of cells that leads to structural and functional changes in the heart muscle. Therefore, specialists try to find a way to repair and regenerate the heart muscle after myocardial infarction. Tissue engineering is used to develop substantial alternatives to assist clinical therapies. Recent studies have focused on the construction of scaffolds with various advanced techniques to create guiding channels that mimic the natural... 

    Heart Disease Diagnosis Based on Heart Sounds Using Signal Processing and Machine Learning Algorithms

    , M.Sc. Thesis Sharif University of Technology Zeinali, Yasser (Author) ; Akhavan Niaki, Taghi (Supervisor)
    Abstract
    The research in this study aims to analyze data in healthcare, especially the diagnosis of several diseases caused by heart failure. Analyzing and analyzing this data can lead to the discovery of relationships and patterns that can play an important role in the decision-making process of relevant officials in any field. Today, medical data around the world is stored in large volumes for future research. Various infrastructures and software have been set up in many health centers and research centers affiliated with those organizations.In this research, the general process of work is such that the data related to the heart sounds, which are in the four broad categories of S1 to S4, are... 

    Mathematical modeling of heart rate and blood pressure variations due to changes in breathing pattern

    , Article 2013 20th Iranian Conference on Biomedical Engineering, ICBME 2013, Tehran, 18 December 2013 through 20 December 2013 ; 2013 , Pages 54-58 Goldoozian, L. S ; Zahedi, E ; Sharif University of Technology
    IEEE Computer Society  2013
    Abstract
    Analysis of the heart rate (HR) variation due to respiration, known as respiratory sinus arrhythmia (RSA), is a method to assess the autonomic nervous system (ANS) function. In this paper a physiologically-based mathematical model consisting of the cardiorespiratory system and ANS control has been used in order to study the cardiovascular response (mean arterial blood pressure and HR) to breathing with different respiration rates and tidal volumes. Simulation results show that RSA has its maximal amplitude at the respiration frequency of 0.12 Hz and that RSA amplitude varies linearly by tidal volume. These results are in agreement with real data from the literature. In addition, the... 

    Introducing an adaptive robust controller for artificial heart

    , Article Proceedings of the IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics, 24 June 2012 through 27 June 2012 ; June , 2012 , Pages 413-418 ; 21551774 (ISSN) ; 9781457711992 (ISBN) Ravanshadi, S ; Jahed, M ; Sharif University of Technology
    2012
    Abstract
    Prolonged and uncontrolled high shear stresses and turbulence can cause hemolysis, while alternating and low-level stresses may contribute to platelet activation and thrombus formation. Such deficiencies are reported for Total Artificial Heart (TAH) systems which are generally not fully capable of dynamic adaptation to sudden pressure and volume changes. This study introduces an adaptive robust controller for a linear motor based TAH (LMTAH) which overcomes such shortcomings. Proposed controller performance is compared with simulated natural heart in normal and stressed physiological conditions. Application of adaptive robust control results in flows with less stress variation and... 

    Characteristics of early repolarization pattern in the Iranian population

    , Article Iranian Red Crescent Medical Journal ; Volume 19, Issue 3 , 2017 ; 20741804 (ISSN) Mollazadeh, R ; Sehhati, F ; Eslami, M ; Nemati, F ; Monfarednasab, M ; Sefidbakht, S ; Sharif University of Technology
    Kowsar Medical Publishing Company  2017
    Abstract
    Background: The early repolarization pattern (ERP) has been considered a normal variant in electrocardiography (ECG) for a long time. Nevertheless, increasing evidence has demonstrated its association with adverse outcomes. Objectives: The present study aimed to evaluate the prevalence of ERP in the Iranian general population and demonstrate its clinical and ECG correlates. Methods: A cross sectional study, comprising 1424 consecutive healthy adult individuals, was conducted at two university based hospitals in Tehran, Iran in 2012-2013. The ERP prevalence, clinical characteristics and ECG morphology were investigated in volunteers. Results: ERP was present in 136 out of 1,424 people (9.6%).... 

    Combined effects of electric stimulation and microgrooves in cardiac tissue-on-a-chip for drug screening

    , Article Small Methods ; Volume 4, Issue 10 , 2020 Ren, L ; Zhou, X ; Nasiri, R ; Fang, J ; Jiang, X ; Wang, C ; Qu, M ; Ling, H ; Chen, Y ; Xue, Y ; Hartel, M.C ; Tebon, P ; Zhang, S ; Kim, H.-J ; Yuan, X ; Shamloo, A ; Dokmeci, M. R ; Li, S ; Khademhosseini, A ; Ahadian, S ; Sun, W ; Sharif University of Technology
    John Wiley and Sons Inc  2020
    Abstract
    Animal models and traditional cell cultures are essential tools for drug development. However, these platforms can show striking discrepancies in efficacy and side effects when compared to human trials. These differences can lengthen the drug development process and even lead to drug withdrawal from the market. The establishment of preclinical drug screening platforms that have higher relevancy to physiological conditions is desirable to facilitate drug development. Here, a heart-on-a-chip platform, incorporating microgrooves and electrical pulse stimulations to recapitulate the well-aligned structure and synchronous beating of cardiomyocytes (CMs) for drug screening, is reported. Each chip...