Loading...
Search for: mechanical-stress
0.006 seconds
Total 58 records

    Preparation and characteristics of epoxy/clay/B4C nanocomposite at high concentration of boron carbide for neutron shielding application

    , Article Radiation Physics and Chemistry ; Volume 141 , 2017 , Pages 223-228 ; 0969806X (ISSN) Kiani, M. A ; Ahmadi, S. J ; Outokesh, M ; Adeli, R ; Mohammadi, A ; Sharif University of Technology
    Abstract
    In this research, the characteristics of the prepared samples in epoxy matrix by means of X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDS), as well as scanning electron microscope (SEM) are evaluated. Meanwhile, the obtained mechanical properties of the specimen are investigated. Thermogravimetric analysis (TGA) is also employed to evaluate the thermal degradation of manufactured nanocomposites. The thermal neutron absorption properties of nanocomposites containing 3 wt% of montmorillonite nanoclay (closite30B) have been studied experimentally, using an Am-Be point source. Mechanical tests reveal that the higher B4C concentrations, the more tensile strengths, but lower... 

    Plaque structure affects mechanical stress distribution within blood vessels

    , Article Proceedings of the IASTED International Conference on Biomedical Engineering, BioMed 2014 ; 2014 , pp. 239-243 Mohseni, M ; Mehboudi, N ; Abdollahi, M ; Shamloo, A ; Naghdabadi, R ; Sharif University of Technology
    Abstract
    The main goal of this study is to investigate the effects of plaque structure on its stress distribution. Rupture of plaque causes cerebrovascular diseases which lead to high mortality rates all over the world. Computers are powerful tools to understand the mechanism of plaque rupture. In this study, 3D fluid structure interaction simulation is constructed in ABAQUS 6.13 to clarify the relation between stress distribution of plaque and its structure. A model of common carotid artery with distributed stenosis was chosen for the simulation. To investigate the effects of plaque structure on stress distribution, thickness of fibrous cap and lipid core size were varied in the stenosis.... 

    On thermomechanical stress analysis of adhesively bonded composite joints in presence of an interfacial void

    , Article Composite Structures ; Volume 130 , October , 2015 , Pages 116-123 ; 02638223 (ISSN) Tahani, M ; Yousefsani, S. A ; Sharif University of Technology
    Elsevier Ltd  2015
    Abstract
    This paper deals with analytical thermomechanical stress analysis of adhesively bonded composite joints in presence of a structural imperfection in the form of an interfacial void within the adhesive layer based on the full layerwise theory (FLWT). The joints are subjected to mechanical tension, uniform temperature change, or steady-state heat conduction. The proposed adhesive joint is divided into three distinct regions along its length and a large number of mathematical plies through its thickness. Three sets of fully coupled governing equilibrium equations are derived employing the principle of minimum total potential energy. The three-dimensional nonlinear interlaminar stress... 

    Notch-texture strengthening mechanism in commercially pure titanium thin sheets

    , Article Materials and Design ; Vol. 55, issue , March , 2014 , p. 683-689 Nasiri-Abarbekoh, H ; Abbasi, R ; Ekrami, A ; Ziaei-Moayyed, A. A ; Sharif University of Technology
    Abstract
    Simultaneous effects of notch and texture on strengthening mechanisms of rolled thin sheets of commercially pure titanium were investigated. The presence of notch led to the restriction of deformation systems and different fracture behaviors compared to un-notched specimens. The loss of material's ability to accommodate plastic deformation at the notch tip with increase in rolling reductions changed the notch strengthening phenomenon to the notch weakening one. At medium levels of deformation, due to the simultaneous development of a triaxial stress state and strong basal texture at the notch tip, a new strengthening mechanism which is called "notch-texture strengthening mechanism" led to a... 

    Nanomedicine applications in orthopedic medicine: State of the art

    , Article International Journal of Nanomedicine ; Volume 10 , 2015 , Pages 6039-6054 ; 11769114 (ISSN) Mazaheri, M ; Eslahi, N ; Ordikhani, F ; Tamjid, E ; Simchi, A ; Sharif University of Technology
    Dove Medical Press Ltd  2015
    Abstract
    The technological and clinical need for orthopedic replacement materials has led to significant advances in the field of nanomedicine, which embraces the breadth of nanotechnology from pharmacological agents and surface modification through to regulation and toxicology. A variety of nanostructures with unique chemical, physical, and biological properties have been engineered to improve the functionality and reliability of implantable medical devices. However, mimicking living bone tissue is still a challenge. The scope of this review is to highlight the most recent accomplishments and trends in designing nanomaterials and their applications in orthopedics with an outline on future directions... 

    Multi-layered nature of the wall of the carotid-artery bifurcation on hemodynamic and mechanical stress and strain

    , Article 2011 18th Iranian Conference of Biomedical Engineering, ICBME 2011 ; 2011 , Pages 84-89 ; 9781467310055 (ISBN) Nikparto, A ; Firoozabadi, B. D ; Sharif University of Technology
    Abstract
    Arterial diseases, namely atherosclerosis, are believed to be a product of abnormal changes in both hemodynamic and non-hemodynamic factors. In order to explornmk,e the role of different factors in initiation and progression of this disease, a CFD technique was applied to study Interaction between the structure of the artery and blood flow for different suggested models that were used to describe mechanics of vessel wall. This study presents a three-dimensional, steady state simulation of blood flow through the single and double layered carotid artery bifurcation using fluid structure interaction (FSI) method. The wall shear stress and mechanical stress/strain are computed and analyzed under... 

    Micromechanical modeling of rate-dependent behavior of Connective tissues

    , Article Journal of Theoretical Biology ; Volume 416 , 2017 , Pages 119-128 ; 00225193 (ISSN) Fallah, A ; Ahmadian, M. T ; Firozbakhsh, K ; Aghdam, M. M ; Sharif University of Technology
    Academic Press  2017
    Abstract
    In this paper, a constitutive and micromechanical model for prediction of rate-dependent behavior of connective tissues (CTs) is presented. Connective tissues are considered as nonlinear viscoelastic material. The rate-dependent behavior of CTs is incorporated into model using the well-known quasi-linear viscoelasticity (QLV) theory. A planar wavy representative volume element (RVE) is considered based on the tissue microstructure histological evidences. The presented model parameters are identified based on the available experiments in the literature. The presented constitutive model introduced to ABAQUS by means of UMAT subroutine. Results show that, monotonic uniaxial test predictions of... 

    Margination and adhesion of micro- and nanoparticles in the coronary circulation: A step towards optimised drug carrier design

    , Article Biomechanics and Modeling in Mechanobiology ; Volume 17, Issue 1 , 2018 , Pages 205-221 ; 16177959 (ISSN) Forouzandehmehr, M ; Shamloo, A ; Sharif University of Technology
    Springer Verlag  2018
    Abstract
    Obstruction of left anterior descending artery (LAD) due to the thrombosis or atherosclerotic plaques is the leading cause of death worldwide. Targeted delivery of drugs through micro- and nanoparticles is a very promising approach for developing new strategies in clot-busting or treating restenosis. In this work, we modelled the blood flow characteristics in a patient-specific reconstructed LAD artery by the fluid–solid interaction method and based on physiological boundary conditions. Next, we provided a Lagrangian description of micro- and nanoparticles dynamics in the blood flow considering their Brownian motion and the particle–particle interactions. Our results state that the number of... 

    High-temperature deformation and structural restoration of a nanostructured Al alloy

    , Article Scripta Materialia ; Volume 66, Issue 11 , 2012 , Pages 911-914 ; 13596462 (ISSN) Asgharzadeh, H ; Simchi, A ; Kim, H. S ; Sharif University of Technology
    2012
    Abstract
    We studied the flow stress and microstructural changes of nanostructured Al-6063 alloy produced by mechanical alloying at various temperatures and strain rates. The analysis of flow curves was performed by a constitutive equation, and the stress exponent and activation energy were determined as functions of strain. The deformation mechanisms were elaborated through microstructural observations by electron backscattering diffraction and transmission electron microscopy. Coarsening of the subgrains and grain growth upon deformation was monitored and related to the Zener-Hollomon parameter  

    Fully coupled analysis of interaction between the borehole and pre-existing fractures

    , Article International Journal of Rock Mechanics and Mining Sciences ; Volume 89 , 2016 , Pages 151-164 ; 13651609 (ISSN) Gomar, M ; Goodarznia, I ; Shadizadeh, S. R ; Sharif University of Technology
    Elsevier Ltd  2016
    Abstract
    The coupling of rock and thermal stresses along with fluid pressure are particularly important in fractured rock masses, since stress-induced changes in permeability can be large and irreversible under perturbations resulting from various natural and induced activities. A new method is presented to model fracture permeability changes during drilling in fractured rocks. The approach includes finite element method (FEM) for fully coupled thermo-poroelastic analysis of stress distribution around borehole and displacement discontinuity method (DDM) to model fracture deformation. Three cases of overbalanced, underbalanced, and balanced drilling fluid pressure conditions are employed. The... 

    Fluid–structure interaction simulation of a cerebral aneurysm: effects of endovascular coiling treatment and aneurysm wall thickening

    , Article Journal of the Mechanical Behavior of Biomedical Materials ; Volume 74 , 2017 , Pages 72-83 ; 17516161 (ISSN) Shamloo, A ; Nejad, M. A ; Saeedi, M ; Sharif University of Technology
    Abstract
    In the present study, we investigate the effect of the hemodynamic factors of the blood flow on the cerebral aneurysms. To this end, a hypothetical geometry of the aneurysm in the circle of Willis, located in the bifurcation point of the anterior cerebral artery (ACA) and anterior communicating artery (ACoA) is modeled in a three-dimensional manner. Three cases are chosen in the current study: an untreated thin wall (first case), untreated thick wall (second case), and a treated aneurysm (third case). The effect of increasing the aneurysm wall thickness on the deformation and stress distribution of the walls are studied. The obtained results showed that in the second case, a reduction in the... 

    Endothelial cells morphology in response to combined wss and biaxial cs: introduction of effective strain ratio

    , Article Cellular and Molecular Bioengineering ; Volume 13, Issue 6 , 2020 , Pages 647-657 Pakravan, H. A ; Saidi, M. S ; Firoozabadi, B ; Sharif University of Technology
    Springer  2020
    Abstract
    Introduction: Endothelial cells (ECs) morphology strongly depends on the imposed mechanical stimuli. These mechanical stimuli include wall shear stress (WSS) and biaxial cyclic stretches (CS). Under combined loading, the effect of CS is not as simple as pure CS. The present study investigates the morphological response of ECs to the realistic mechanical stimuli. Methods: The cell population is theoretically studied using our previous validated model. The mechanical stimuli on ECs are described using four parameters; WSS magnitude (0 to 2.0 Pa), WSS angle (− 50° to 50°), and biaxial CS in two perpendicular directions (0 to 10%). The morphology of ECs is reported using four parameters; average... 

    Effect of soil structure and disturbance on hydromechanical behavior of collapsible loessial soils

    , Article International Journal of Geomechanics ; Volume 17, Issue 1 , 2017 , Pages 1-15 ; 15323641 (ISSN) Mohsen Haeri, S ; Khosravi, A ; Akbari Garakani, A ; Ghazizadeh, S ; Sharif University of Technology
    American Society of Civil Engineers (ASCE)  2017
    Abstract
    To characterize the role of specimen disturbance and structure in the hydromechanical behavior of collapsible soils, two sets of wetting-induced collapse and suction-controlled triaxial tests were conducted on intact and reconstituted specimens of a loessial soil taken from a loess deposit in Gorgan, a city in the northeastern Golestan province of Iran. The testing approach used an advanced triaxial testing device that was specifically modified to control pressures applied to a soil specimen and to monitor and measure the amount of changes in volume and water content of the soil specimens during testing using highly sensitive digital sensors with an accuracy of 60.01 cm3. Results of the... 

    Effect of microthread design of dental implants on stress and strain patterns: A three-dimensional finite element analysis

    , Article Biomedizinische Technik ; Volume 58, Issue 5 , September , 2013 , Pages 457-467 ; 00135585 (ISSN) Amid, R ; Raoofi, S ; Kadkhodazadeh, M ; Movahhedi, M. R ; Khademi, M ; Sharif University of Technology
    Walter de Gruyter and Co  2013
    Abstract
    The aim of this study was to use finite element analysis (FEA) to assess the influence of microthread design at the implant neck on stress distribution in the surrounding bone. A commercially available implant with 3.5 mm diameter and 10.5 mm length was selected and used as a model. For the purpose of designing the microthread implant model, microthreads were added to the implant neck in a computerized model. A force measuring 100 N was then applied to the entire surface of the abutment in the vertical direction. The results showed that in both models, stress was mainly concentrated at the cortical bone adjacent to the neck of the implant. Maximum stress values in the cortical bone... 

    Effect of centrifugal force on natural frequency of lateral vibration of rotating shafts

    , Article Journal of Sound and Vibration ; Volume 274, Issue 3-5 , 2004 , Pages 985-995 ; 0022460X (ISSN) Behzad, M ; Bastami, A. R ; Sharif University of Technology
    Academic Press  2004
    Abstract
    This paper investigates the effect of shaft rotation on its natural frequency. Apart from gyroscopic effect, the axial force originated from centrifugal force and the Poisson effect results in change of shaft natural frequency. D'Alembert principle for shaft in cylindrical co-ordinate system, along with the stress-strain relation, gives the non-homogenous linear differential equation, which can be used to calculate axial stress in the shaft. Numerical results of this study show that axial stress produced by shaft rotation has a major effect on the natural frequency of long high-speed shafts, while shaft diameter has no influence on the results. In addition, change in lateral natural... 

    Dynamic parameters of saturated and unsaturated sand at different ranges of shear strain levels in cyclic simple shear tests

    , Article 14th Asian Regional Conference on Soil Mechanics and Geotechnical Engineering ; 2011 Jafarzadeh, F ; Golshan, Z ; Sharif University of Technology
    2011
    Abstract
    In order to evaluate dynamic properties of Babolsar and Toyoura sands at saturation levels of 25, 50, 75 & 100%, a series of cyclic simple shear tests were carried out. The SGI type cyclic simple shear device was used to study the shear modulus, G, and damping ratio, D, of the above mentioned sands at cyclic shear strain of 0.5, 5 & 10%. The effect of degree of saturation (S), vertical consolidation stress (σ vc) and number of loading cycles (N) were investigated. On the basis of the tests results, the shear modulus approximately remains constant by change of degree of saturation from 25 to 50% and decreases when reaches the degree of saturation 75%. Damping ratio approximately is constant... 

    Design optimization of an above-knee prosthesis based on the kinematics of gait

    , Article 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08, Vancouver, BC, 20 August 2008 through 25 August 2008 ; 2008 , Pages 4274-4277 ; 9781424418152 (ISBN) Pejhan, S ; Farahmand, F ; Parnianpour, M ; Sharif University of Technology
    2008
    Abstract
    A dynamic model of an above-knee prosthesis during the complete gait cycle was developed. The model was based on a two-dimensional multi-body mechanical system and included a hydraulic and an elastic controller for the knee and a kinematical driver controller for the prosthetic ankle. The equations of motion were driven using Lagrange method. Simulation of the foot contact was conducted using a two-point penetration contact model. The knee elastic and hydraulic controller units, the knee extension stop, and the kinematical driver controller of the ankle were represented by a spring and a dashpot, a nonlinear spring, and a torsional spring-damper within a standard prosthetic configuration.... 

    Comparison of periodontally compromised splinted teeth and implant supported fixed partial denture: a three-dimensional finite element analysis on bone response

    , Article Journal of long-term effects of medical implants ; Volume 31, Issue 2 , 2021 , Pages 1-8 ; 19404379 (ISSN) Amid, R ; Kadkhodazadeh, M ; Talebi Ardakani, M. R ; Movahhedy, M. R ; Mirakhori, M ; Hakimi, A ; Broukhim, M ; Sharif University of Technology
    NLM (Medline)  2021
    Abstract
    Introduction - This study aimed to compare the amount and pattern of stress and strain distributed around periodontally compromised splinted teeth and the two-implant abutments supported six-unit fixed partial denture (FPD) using finite element analysis (FEA). Methods and Materials - Six mandibular anterior teeth of a dental model were scanned and the scans were transferred to 3D CAD design and finite element software. Jaw bone was also designed and the teeth were splinted by fiber-reinforced composite (FRC) band. In another model, two implants were placed at the site of canine teeth and a six-unit FPD was designed over them. Models were transferred to finite element software and after... 

    Compact basis free relations for stress tensors conjugate to Hill's strain measures

    , Article 8th Biennial ASME Conference on Engineering Systems Design and Analysis, ESDA2006, Torino, 4 July 2006 through 7 July 2006 ; Volume 2006 , 2006 ; 0791837793 (ISBN); 9780791837795 (ISBN) Naghdabadi, R ; Asghari, M ; Ghavam, K ; Sharif University of Technology
    American Society of Mechanical Engineers  2006
    Abstract
    If the double contraction of a stress tensor such as T and rate of a Lagrangean strain tensor such as E, i.e. T : Ė produces the stress power then these stress and strain tensors are called a conjugate pair. The applications of the conjugate stress and strain measures are in the development of the basic relations in nonlinear continuum mechanics analysis such as modeling of constitutive equations of elastic-plastic materials. In this paper relations for stress tensors conjugate to an arbitrary Lagrangean strain measure of Hill's class are obtained. The results of this paper are more compact and simpler in compare with those available in the literature. The results are valid for the three... 

    Basis free expressions for the stress rate of isotropic elastic materials in the cases of coalescent principal stretches

    , Article International Journal of Solids and Structures ; Volume 47, Issue 5 , 2010 , Pages 611-613 ; 00207683 (ISSN) Asghari, M ; Sharif University of Technology
    2010
    Abstract
    In this paper, some basis-free expressions for the material time derivative of Lagrangian stress tensors are presented which are generally valid in all cases of coalescent principal stretches. The material is assumed to be elastic and isotropic