Loading...
Search for: optimal-conditions
0.007 seconds
Total 89 records

    Optimization of dispersive liquid-liquid microextraction and improvement of detection limit of methyl tert-butyl ether in water with the aid of chemometrics

    , Article Journal of Chromatography A ; Volume 1217, Issue 45 , November , 2010 , Pages 7017-7023 ; 00219673 (ISSN) Karimi, M ; Sereshti, H ; Samadi, S ; Parastar, H ; Sharif University of Technology
    2010
    Abstract
    Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry-selective ion monitoring (GC-MS-SIM) was applied to the determination of methyl tert-butyl ether (MTBE) in water samples. The effect of main parameters affecting the extraction efficiency was studied simultaneously. From selected parameters, volume of extraction solvent, volume of dispersive solvent, and salt concentration were optimized by means of experimental design. The statistical parameters of the derived model were R 2=0.9987 and F=17.83. The optimal conditions were 42.0μL for extraction solvent, 0.30mL for disperser solvent and 5% (w/v) for sodium chloride. The calibration linear range... 

    Membrane protected conductive polymer as micro-SPE device for the determination of triazine herbicides in aquatic media

    , Article Journal of Separation Science ; Volume 33, Issue 8 , 2010 , Pages 1132-1138 ; 16159306 (ISSN) Bagheri, H ; Khalilian, F ; Naderi, M ; Babanezhad, E ; Sharif University of Technology
    Abstract
    A micro-SPE technique was developed by fabricating a rather small package including a polypropylene membrane shield containing the appropriate sorbent. The package was used for the extraction of some triazine herbicides from aqueous samples. Solvent desorption was subsequently performed in a microvial and an aliquot of extractant was injected into GC-MS. Various sorbents including aniline-ortho-phenylene diamine copolymer, newly synthesized, polypyrrole, multiwall carbon nanotube, C18 and charcoal were examined as extracting media. Among them, conductive polymers exhibited better performance. Influential parameters including extraction and desorption time, desorption solvent and the ionic... 

    Kinetics investigation of the photocatalytic degradation of acid blue 92 in aqueous solution using nanocrystalline TiO2 prepared in an ionic liquid

    , Article Progress in Reaction Kinetics and Mechanism ; Volume 34, Issue 1 , 2009 , Pages 55-76 ; 14686783 (ISSN) Ghasemi, S ; Rahimnejad, S ; Rahman Setayesh, S ; Hosseini, M ; Gholami, M. R ; Sharif University of Technology
    2009
    Abstract
    TiO2 nanoparticles were prepared by the sol - gel process using 2-hydroxylethy- lammonium formate as an ionic liquid. Nanoparticles were crystallized at various temperatures (300-700°C). The products were characterized using X-ray diffraction (XRD), nitrogen adsorption - desorption isotherms and scanning electron microscopy (SEM) techniques. It was found that the resulting TiO2 nanoparticles had good thermal stability either to resist collapse or the anatase-to-rutile phase transformation during heat treatment. The photocatalytic activity of the nanocrystalline TiO2 was evaluated by the degradation of Acid Blue 92 (AB92) which is commonly used as a textile dye. The results showed that the... 

    Graphene oxide-l-arginine nanogel: A pH-sensitive fluorouracil nanocarrier

    , Article Biotechnology and Applied Biochemistry ; Volume 66, Issue 5 , 2019 , Pages 772-780 ; 08854513 (ISSN) Malekimusavi, H ; Ghaemi, A ; Masoudi, G ; Chogan, F ; Rashedi, H ; Yazdian, F ; Omidi, M ; Javadi, S ; Haghiralsadat, B. F ; Teimouri, M ; Faal Hamedani, N ; Sharif University of Technology
    Wiley-Blackwell Publishing Ltd  2019
    Abstract
    Nowadays, putting forward an accurate cancer therapy method with minimal side effects is an important topic of research. Nanostructures, for their ability in controlled and targeted drug release on specific cells, are critical materials in this field. In this study, a pH-sensitive graphene oxide-l-arginine nanogel was synthesized to carry and release 5-fluorouracil. Optimized conditions using statistical analysis, based on the maximum relative viscosity of nanogel, were evaluated: 5.489 for the concentration of l-arginine and 2.404 for pH. The prepared nanogels were characterized using scanning electron microscope and transmission electron microscope images and Fourier-transform infrared... 

    Development of a method for analysis of Iranian damask rose oil: combination of gas chromatography-mass spectrometry with Chemometric techniques

    , Article Analytica Chimica Acta ; Volume 623, Issue 1 , 8 August , 2008 , Pages 11-21 ; 00032670 (ISSN) Jalali Heravi, M ; Parastar, H ; Sereshti, H ; Sharif University of Technology
    2008
    Abstract
    Gas chromatography-mass spectrometry (GC-MS) combined with Chemometric resolution techniques were proposed as a method for the analysis of volatile components of Iranian damask rose oil. The essential oil of damask rose was extracted using hydrodistillation method and analyzed with GC-MS in optimized conditions. A total of 70 components were identified using similarity searches between mass spectra and MS database. This number was extended to 95 components with concentrations higher than 0.01% accounting for 94.75% of the total relative content using Chemometric techniques. For the first time in this work, an approach based upon subspace comparison is used for determination of the chemical... 

    Liquid-liquid-liquid microextraction followed by HPLC with UV detection for quantitation of ephedrine in urine

    , Article Journal of Separation Science ; Volume 31, Issue 18 , 2008 , Pages 3212-3217 ; 16159306 (ISSN) Bagheri, H ; Khalilian, F ; Ahangar, L. E ; Sharif University of Technology
    2008
    Abstract
    Liquid-liquid-liquid microextraction (LLLME) in combination with HPLC and UV detection has been used as a sensitive method for the determination of ephedrine in urine samples. Extraction process was performed in a homemade total glass vial without using a Teflon ring, usually employed. Ephedrine was first extracted from 3.5 mL of urine sample (pH 12) into a microfilm of toluene/benzene (50:50). The analyte was subsequently back extracted into an acidic microdrop solution (pH 2) suspended in the organic phase. The extract was then injected into the HPLC system directly. An enrichment factor of 137 along with a good sample clean-up was obtained under the optimized conditions. The calibration... 

    In situ solid-phase microextraction and post on-fiber derivatization combined with gas chromatography-mass spectrometry for determination of phenol in occupational air

    , Article Analytica Chimica Acta ; Volume 742 , 2012 , Pages 17-21 ; 00032670 (ISSN) Es haghi, A ; Baghernejad, M ; Bagheri, H ; Sharif University of Technology
    Elsevier  2012
    Abstract
    A method based on solid-phase microextraction (SPME) followed by on-fiber derivatization and gas chromatography-mass spectrometry detection (GC-MS) for determination of phenol in air was developed. Three different types of SPME fibers, polar and non-polar poly(dimethylsiloxane) (PDMS) and polyethylene glycol (PEG) were synthesized using sol-gel technology and their feasibility to the sampling of phenol were investigated. Different derivatization reagents for post on-fiber derivatization of phenol were studied. Important parameters influencing the extraction and derivatization process such as type of fiber coating, type and volume of derivatizing reagent, derivatization time and temperature,... 

    Novel polyamide-based nanofibers prepared by electrospinning technique for headspace solid-phase microextraction of phenol and chlorophenols from environmental samples

    , Article Analytica Chimica Acta ; Volume 716 , 2012 , Pages 34-39 ; 00032670 (ISSN) Bagheri, H ; Aghakhani, A ; Baghernejad, M ; Akbarinejad, A ; Sharif University of Technology
    2012
    Abstract
    A novel solid phase microextraction (SPME) fiber was fabricated by electrospinning method in which a polymeric solution was converted to nanofibers using high voltages. A thin stainless steel wire was coated by the network of polymeric nanofibers. The polymeric nanofiber coating on the wire was mechanically stable due to the fine and continuous nanofibers formation around the wire with a three dimensional structure. Polyamide (nylon 6), due to its suitable characteristics was used to prepare the unbreakable SPME nanofiber. The scanning electron microscopy (SEM) images of this new coating showed a diameter range of 100-200nm for polyamide nanofibers with a homogeneous and porous surface... 

    Immersed single-drop microextraction-electrothermal vaporization atomic absorption spectroscopy for the trace determination of mercury in water samples

    , Article Journal of Hazardous Materials ; Volume 165, Issue 1-3 , 2009 , Pages 353-358 ; 03043894 (ISSN) Bagheri, H ; Naderi, M ; Sharif University of Technology
    2009