    Ionic liquid excess molar volume prediction: a conceptual comparison

    , Article Journal of Molecular Liquids ; Volume 336 , 2021 ; 01677322 (ISSN) Bagheri, H ; Karimi, N ; Dan, S ; Notej, B ; Ghader, S ; Sharif University of Technology
    Elsevier B.V  2021
    Abstract
    In this study, the prediction of excess molar volume of ionic liquid + solvent binary system is described using modified two-parameter and three-parameter cubic equation of state (CEoS). The studied binary systems are consisted of 41 ionic liquids, 40 solvents and 5293 data point in the wide temperature range (278.15–353.15 K), ionic liquid mole fraction (0.0036–0.9920) and atmospheric pressure i.e. P = 1 bar. At the first step, the volume-translated parameter (c) was obtained based on three linear, distance function and exponential-type temperature-dependent cases and using experimental pure density. After that, and due to easy-to-use of c-parameter, various formula was presented based on... 

    A simplified droop method implementation in parallel UPS inverters with Proportional-Resonant controller

    , Article Iranian Journal of Science and Technology, Transaction B: Engineering ; Volume 33, Issue 2 , 2009 , Pages 163-178 ; 10286284 (ISSN) Hasanzadeh, A ; Mokhtari, H ; Sharif University of Technology
    2009
    Abstract
    In this paper, a simpler implementation of the well-known droop method for the control of parallel Uninterruptible Power Supply (UPS) systems is presented. In this method, in the power-sharing control scheme, the output current is calculated by software without the need for a current sensor, resulting in a simpler and cheaper structure. By doing so, the number of feedback sensors is reduced from three to two. The paralleling strategy uses the droop method in which the control strategy is based on the drop in the inverter output frequency and amplitude. The application of Proportional-Resonant (PR) controllers is also extended to parallel inverter and its superior performance over the... 

    Clinical validation of a smartphone-based handheld ECG device: A validation study

    , Article Critical Pathways in Cardiology ; Volume 21, Issue 4 , 2022 , Pages 165-171 ; 1535282X (ISSN) Ahmadi-Renani, S ; Gharebaghi, M ; Kamalian, E ; Hajghassem, H ; Ghanbari, A ; Karimi, A ; Mansoury, B ; Dayari, M. S ; Khatmi Nemati, M ; Karimi, A ; Zarghami, M. H ; Vasheghani Farahani, A ; Sharif University of Technology
    Lippincott Williams and Wilkins  2022
    Abstract
    Background: Remote cardiac monitoring and screening have already become an integral telemedicine component. The wide usage of several different wireless electrocardiography (ECG) devices warrants a validation study on their accuracy and reliability. Methods: Totally, 300 inpatients with the Nabz Hooshmand-1 handheld ECG device and the GE MAC 1200 ECG system (as the reference) were studied to check the accuracy of the devices in 1 and 6-limb lead performance. Simultaneous 10-second resting ECGs were assessed for the most common ECG parameters in lead I. Afterward, 6-lead ECGs (limb leads), were performed immediately and studied for their morphologies. Results: Of the 300 patients, 297 had...