Loading...
Search for:
bolorian-kord--mohammad-navid
0.147 seconds
Total 5436 records
Investigating the Performance of Tuned Mass Dampers in Controlling the Torsional Response of 3-D Steel Structural Models Under Earthquake Excitation
, M.Sc. Thesis Sharif University of Technology ; Rahimzadeh Rofouei, Fayyaz (Supervisor)
Abstract
Existing structural irregularities (in plan and elevation) has always been among the important causes of structural failures under strong earthquakes. The torsional related damages have especially been very important in multi-story buildings as the torsional behavior of structures changes their uniform translational vibration and causes concentration of demands in the elements at the perimeter of the buildings. On the other hand, the Tuned Mass Dampers (TMD) have in general been accepted as an effective passive structural control device to suppress the structural vibration. In this study, Three 3-D, irregular (in plan) steel structural models with 4, 8 and 15 number of floors are considered...
Effect of Obesity on Spinal Loads during Various Activities: A Combined in Vivo-Modeling Approach
, M.Sc. Thesis Sharif University of Technology ; Arjmand, Navid (Supervisor)
Abstract
Obesity is a worldwide growing health challenge affecting ~30% of the world's population. Increased rate of disc degeneration and herniation, low back pain and surgery has been reported in obese individuals. Although obesity-related low back diseases have multifactorial etiology, presumably greater mechanical loads on the spine of heavier individuals during their daily activities may be considered as a risk factor. Likely larger trunk muscle sizes, disc sizes and thus passive stiffness in heavier individuals may however partly or fully offset the effect of their additional body weight on the spinal loads. In absence of in vivo approaches, the present study aims to construct subject-specific...
Effect of Obesity on Spinal Loads during Various Activities: A Combined in Vivo-Modeling Approach
, M.Sc. Thesis Sharif University of Technology ; Arjmand, Navid (Supervisor) ; Parnianpour, Mohammad (Supervisor)
Abstract
Obesity is a worldwide growing health challenge affecting ~30% of the world's population. Increased rate of disc degeneration and herniation, low back pain and surgery has been reported in obese individuals. Although obesity-related low back diseases have multifactorial etiology, presumably greater mechanical loads on the spine of heavier individuals during their daily activities may be considered as a risk factor. Likely larger trunk muscle sizes, disc sizes and thus passive stiffness in heavier individuals may however partly or fully offset the effect of their additional body weight on the spinal loads. In absence of in vivo approaches, the present study aims to construct subject-specific...
The Effects of Vibrations Transferred to Vehicle Occupants on Spinal Loads as Function of Pelvic-lumbar Orientation, Posture, Seat Specifications and Seat Back Inclination Using FEM
, M.Sc. Thesis Sharif University of Technology ; Arjmand, Navid (Supervisor) ; Parnianpour, Mohammad (Supervisor)
Abstract
Due to adverse health problems with lumbar spine among professional drivers associated with exposure to whole body vibration (WBV), studying the effect of vibrations and parameters influencing WBV is of great importance. This study aims to simulate whole body vibration for a ground vehicle occupant and calculate loads that lumbar spine tolerate during harmonic sinusoidal vibrations. Moreover, this study determines the effect of lumbar spine angle, seat specifications (angles and materials), and vibration frequency on the results. To this end, a detailed viscoelastic lumbar spine (L1-S1) has been modeled using FE method which has been replaced with the simplified spine model in HYBRID III...
Selecting and Optimizing Portfolio Using Methaheuristic Methods
, M.Sc. Thesis Sharif University of Technology ; Rmezanian, Rasoul (Supervisor)
Abstract
Portfolio is a collection of different stocks for investment. The investors' objectives in portfolio formation are to get the highest return against exposure to the lowest risk. Portfolio Optimization Problem is one of the most complicated problems in investment and finance. It may be simply explained as follows: Let's imagine a set of N stocks for selection. We would like to see what percentage of the total amount of investment should be dedicated to each stock to maximize portfolio's total return and minimize its total risk.
Portfolio Optimization Problem is a NP-Hard problem and generally there exists no polynomial-time deterministic algorithm to find a precise solution to such a...
Portfolio Optimization Problem is a NP-Hard problem and generally there exists no polynomial-time deterministic algorithm to find a precise solution to such a...
A Detailed Nonlinear Finite Element Model of the L4-L5 Motion Segment to Predcit Spinal Loads during in Vivo Activities
, M.Sc. Thesis Sharif University of Technology ; Arjmand, Navid (Supervisor) ; Parnianpour, Mohammad (Supervisor)
Abstract
Several geometrically-detailed passive finite element (FE) models of the lumbar spine have been developed and validated under in vitro loading conditions. As these models are devoid of muscles, they are either not used to simulate in vivo activities or muscle forces are modeled by a hypothetical compressive follower load (FL). A number of symmetric and asymmetric static tasks were first simulated using a validated musculoskeletal model of the thoracolumbar spine to predict trunk muscle forces. The predicted muscle forces along with the gravity loading were then applied to a passive FE model of the L4-L5 motion segment (developed and validated here) to estimate load sharing among the disc,...
Design of a Novel Cable Driven Robotic System for Simulation of in vivo Loading of Cadaveric Lumbar Spine with Robustness-adaptive Controller for in vitro Spine Testing
, M.Sc. Thesis Sharif University of Technology ; Parnianpour, Mohammad (Supervisor) ; Arjmand, Navid (Supervisor)
Abstract
In this project we plan to propose a mechanism for controlling the profile of vertebra displacment and intera-discal pressure in in-vitro tests. Spineis the one of the most important members of the human musculoskeletal system. Health and stability of the spine help the people to moves on two legs. So any problems with this organ, causing movement problems and pain. For the treatment of spinal diseases, several methods such as surgery, insertion of implants and stabilizing were used. To ensure the accuracy of these methods, laboratory examination is essential. One of the ways to test these interventions, the implementation of in vitro tests on samples obtained from the bodies of the spine....
Effects of Low Back Pain and Posterior Lumbar Surgery on Pattern of Muscle Activities, Trunk Strength and Spinal Stability
, M.Sc. Thesis Sharif University of Technology ; Farahmand, Farzam (Supervisor) ; Arjmand, Navid (Co-Advisor)
Abstract
80% of people in all over the world, experience Low Back Pain (LBP) once in their lives. LBP leads to dysfunction of spine. About 25% of LBP relates to the intervertebral disks which in the critical cases, a Posterior Lumbar Surgery (PLS) on the one or more lumbar disks should be done. Due to the some procedure such as retracting, cutting or denervation of muscles, PLS can hurt trunk muscles and spine. Thus, investigation of LBP and postoperative complications of PLS can help us in recognition of causes of LBP and PLS complications and modification of PLS approaches. The objective of this research was investigation of effects of LBP and PLS on the biomechanical function of spine. Pattern of...
Measurements of the Upper Trunk and Pelvis kinematics Due to Two-handed Symmetric and Asymmetric Reach and Lifting Activities Using Inertial Sensors and Presenting a Neural Network for Posture Prediction
, M.Sc. Thesis Sharif University of Technology ; Arjmand, Navid (Supervisor) ; Parnianpour, Mohammad (Supervisor)
Abstract
Manual material handling (MMH) activities are identified as risk factors for occupational low back pain (LBP). Task-related variables including load and posture characteristics are required as input into these models and tools for estimation of trunk external moment. Biomechanical modeling studies that aim to mathematically estimate low back loads currently need an inevitable parallel time-consuming in vivo study in an equipped laboratory to measure trunk posture under physical activities. Inertial sensors as a portable, accurate, almost inexpensive, and small device could be very helpful in order to capture the kinematic data of movement in human activities. My master thesis aims to...
Effect of Translational Degrees of Freedom of Intervertebral Joints on Prediction of Spinal Load and Muscle Forces in AnyBody Modeling System
, M.Sc. Thesis Sharif University of Technology ; Arjmand, Navid (Supervisor) ; Parnianpour, Mohammad (Co-Advisor)
Abstract
Biomechanical models are indispensable tools in predictions of muscle forces and joint loads towards design of prevention and treatment programs. In most of these models intervertebral joints are modeled as hinge joints thus neglecting the existing translational degrees of freedom (DOFs). This simplification can alter the results of the model as changes in model kinematics affect the prediction of the joint and muscle forces. The current study aims to evaluate the likely effect of this simplification on the predictions of the musculoskeletal model of AnyBody Modeling System (AMS) for muscle forces and spinal loads. Clinical application of this study is in assessing the limitation of...
Design and Fabrication of a Microfluidic Chip for Three-dimensional Cancer Cell Culture
, M.Sc. Thesis Sharif University of Technology ; Saeedi, Mohammad Saeed (Supervisor) ; Kashaninejad, Navid (Co-Advisor)
Abstract
Nowadays, we are witnesses of deaths caused by cancer in large statistical amounts. Vast number of investigations are conducted for anticancer drug evaluation on human and animal cells using traditional two-dimensional and three-dimensional culturing platforms. However, most of them are not successful due to the lack of in-vivo relevant microenvironment in these platforms. One of the best cancer in-vitro cultures is the tumor spheroid which is a spherical cellular aggregation. By culturing these tumor spheroids in a microfluidic chip, it is possible to mimic the in-vivo microenvironment elements such as nutrient and metabolite gradients. Here we present a microfluidic device fabricated using...
Investigation of Microstructural Characteristics and Mechanical Properties of Microalloyed Magnesium X0 via Severe Plastic Deformation Process with Cyclic Closed Die Forging
, M.Sc. Thesis Sharif University of Technology ; Akbarzadeh, Abbas (Supervisor)
Abstract
Nowadays, the application of magnesium alloys as biodegradable implants in the medical industry has garnered significant attention. However, the low mechanical properties and rapid degradation rate of pure magnesium implants in the biological environment have hindered their widespread use for clinical applications. Magnesium-calcium alloys, due to their low degradation rate and promotion of faster bone healing, have become attractive choices for orthopedic applications. Nevertheless, the micro alloy X0 used in this study lacks sufficient strength and flexibility, limiting its potential applications. Utilizing severe plastic deformation methods to create ultrafine microstructures can greatly...
Design and Modeling of an Isolator System for Reducing Transmitted Vibration Levels in Space System
, M.Sc. Thesis Sharif University of Technology ; Saadat Foumani, Mahmoud (Supervisor) ; Ghoreishi, Mohammad Navid (Supervisor)
Abstract
Vibration control is one of the most critical aspects of designing space structures, as it can significantly impact the performance and operational lifespan of satellites. The launch phase is the most sensitive and critical stage in the satellite mission lifecycle, as intense vibrations are generated and transmitted to the satellite during this phase. To mitigate the severity of these transmitted vibrations, vibration isolators are employed. The objective of this study is to design and model a vibration isolator to control the vibrations transmitted from the launcher to the satellite during launch. To achieve this, an extensive investigation into vibration isolators used in the space...
Optimization of Forging Processes with Concurrent Approach
, M.Sc. Thesis Sharif University of Technology ; Hosseini Kord Khyli, Ali (Supervisor)
Abstract
With the increasing complexity of manufacturing processes and the interrelations between the different phases, the possibility of a phase being affected by a preselected desing variable is very high. In that case, the influence of a desing variable not only on the part performance of but also on the feasibility and efficiency of its manufacturing should be considered. Concurrent engineering approaches should then be adopted to take the control of such complicated relations among the subprocesses. In this thesis a concurrent design optimization methodology was proposed to minimize the cost of a cold forged manufacturing process using the design parameters as optimization variables. An...
Asphaltene deposition in carbonate rocks: Experimental investigation and numerical simulation
, Article Energy and Fuels ; Volume 26, Issue 10 , June , 2012 , Pages 6186-6199 ; 08870624 (ISSN) ; Miri, R ; Ayatollahi, S ; Escrochi, M ; Sharif University of Technology
2012
Abstract
Oil production from asphaltenic oil reservoirs has always encountered difficulties, such as plugging and unpredictable fluid properties. To physically recognize the aspects of asphaltene deposition, several dynamic and static asphaltene deposition tests were designed and performed on one of the giant south Iranian oil reservoirs using dead and live crude oil and real core samples. Moreover, the effects of fluid velocity on the extent of damage were investigated. It was found that surface deposition of asphaltene particles is the main source of formation damages in the porous media and the resulting permeability impairment obeys an exponential behavior. All of the experiments confirm that...
Pore-level experimental investigation of ASP flooding to recover heavy oil in fractured five-spot micromodels
, Article EUROPEC 2015, 1 June 2015 through 4 June 2015 ; June , 2015 , Pages 1033-1058 ; 9781510811621 (ISBN) ; Mohammadzadeh, O ; Kord, S ; Chatzis, I ; Sharif University of Technology
Society of Petroleum Engineers
2015
Abstract
Although Alkaline-Surfactant-Polymer (ASP) flooding is proved to be efficient for heavy oil recovery, the displacement mechanisms/efficiency of this process should be discussed further in fractured porous media especially in typical waterflood geometrical configurations such as five-spot injection-production pattern. In this study, several ASP flooding tests were conducted in fractured glass-etched micromodels which were initially saturated with heavy oil. The ASP flooding tests were conducted at constant injection flow rates and different fracture geometrical characteristics were used. The ASP solutions constituted of five polymers, two surfactants and three alkaline types. The results...
Heavy oil recovery using ASP flooding: A pore-level experimental study in fractured five-spot micromodels
, Article Canadian Journal of Chemical Engineering ; Volume 94, Issue 4 , 2016 , Pages 779-791 ; 00084034 (ISSN) ; Mohammadzadeh, O ; Kord, S ; Chatzis, I ; Sharif University of Technology
Wiley-Liss Inc
2016
Abstract
Although alkaline-surfactant-polymer (ASP) flooding has proven efficient for heavy oil recovery, the displacement mechanisms and efficiency of this process should be discussed further in fractured porous media. In this study, several ASP flooding tests were conducted in fractured glass-etched micromodels with a typical waterflood geometrical configuration, i.e. five-spot injection-production pattern. The ASP flooding tests were conducted at constant injection flow rates but different fracture geometrical characteristics. The ASP solutions consisted of five polymers, two surfactants, and three alkaline types. It was found that using synthetic polymers, especially hydrolyzed polyacrylamide...
Lumbopelvic Rhythm during Forward and Backward Sagittal Trunk Rotations; in vivo Measurements Using Inertial Sensors
, M.Sc. Thesis Sharif University of Technology ; Arjmand, Navid (Supervisor)
Abstract
Direct in vivo measurements of spinal loads and muscle forces are invasive. Investigators have thus used musculoskeletal biomechanical models that require kinematic data including trunk and pelvis angular movements as their inputs. . Novel devices measure anglular movements using both inertial sensors (such as gyroscopes and accelerometers) and miniature magnetometers. Relative low cost, portability, and accuracy are among specific characteristics of inertial tracking devices. The main objective of the present study was set to measure spinal kinematics including the lumbopelvic rhythm as the ratio of total lumbar rotation over pelvic rotation during trunk sagittal movement which is essential...
Evaluation of 1991 NIOSH Lifting Equation in Controlling the Biomechanical Loads of the Human Spine
, M.Sc. Thesis Sharif University of Technology ; Arjmand, Navid (Supervisor)
Abstract
The 1991 NIOSH Lifting Equation (NLE) is widely used to assess risk of injury to the spine by providing estimates of the recommended weight limit (RWL) in hands. The present study uses two biomechanical models of the spine to verify whether the RWL generates L5-S1 loads within the limits (e.g., 3400 N for compression recommended by NIOSH and 1000 N for shear recommended in some studies).Severallifting activities are simulated here to evaluate the RWL by the NLE and the L5-S1 loads by the models. In lifting activities involving moderate to large forward trunk flexion, the estimated RWL generates L5-S1 spine loads exceeding the recommended limits. The NIOSH vertical multiplier is the likely...
Sagittal Range of Motion of the Thoracic Spine Using Inertial Tracking Device and Effect of Measurement Errors on Model Predictions
, M.Sc. Thesis Sharif University of Technology ; Arjmand, Navid (Supervisor)
Abstract
Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvis, and entire trunk (T1) ROMs were measured using an inertial tracking device as asymptomatic subjects flexed forward from their neutral upright position to full forward flexion. Correlations between body height and the ROMs were conducted. Effect of measurement errors of the trunk flexion (T1) on the model-predicted spinal loads was investigated. Mean of peak voluntary total...