Loading...
Search for: naderi--m--s
0.139 seconds

    A hybrid transformer model for determination of partial discharge location in transformer winding

    , Article IEEE Transactions on Dielectrics and Electrical Insulation ; Volume 14, Issue 2 , 2007 , Pages 436-443 ; 10709878 (ISSN) Naderi, M. S ; Vakilian, M ; Blackburn, T. R ; Phung, B. T ; Naderi, M. S ; Nasiri, A ; Sharif University of Technology
    2007
    Abstract
    Partial discharges are well known as a source for insulation degradation in power transformers. A hybrid transformer model is introduced to simulate the transformer winding transient response. Transformer structural data is used to determine the hybrid model parameters. Calculations of the hybrid transient model parameters are based on the parameters of the lumped parameter equivalent transformer model and electromagnetic rules. Modern computation techniques and optimizations are employed beside this model for PD location using the multi conductor transmission line model and also to analyze its propagation aimed at achieving (i) more reliable simulation results (ii) less computational time... 

    A method for studying partial discharges location and propagation within power transformer winding based on the structural data

    , Article 2005 International Symposium on Electrical Insulating Materials, ISEIM 2005, Kitakyushu, 5 June 2005 through 9 June 2005 ; Volume 2 , 2005 , Pages 490-493 Naderi, M. S ; Vakilian, M ; Blackburn, T. R ; Phung, B. T ; Zhang, H ; Naderi, M. S ; Sharif University of Technology
    Institute of Electrical Engineers of Japan  2005
    Abstract
    Power transformer inner insulation system is a very critical component. Its degradation may pose apparatus to fail while in service. On the other hand, experimental experiences prove that partial discharges are a major source of insulation failure in power transformers. If the deterioration of the insulation system caused by PD activity can be detected at an early stage, preventive maintenance measures may be taken. Because of the complex structure of the transformer, accurate PD location is difficult and is one of the challenges power utilities are faced with. This problem comes to be vital in open access systems. In this paper a theory for locating partial discharge and its propagation... 

    Constrained swarm stabilization of fractional order linear time invariant swarm systems

    , Article IEEE/CAA Journal of Automatica Sinica ; Volume 3, Issue 3 , 2016 , Pages 320-331 ; 23299266 (ISSN) Naderi Soorki, M ; Tavazoei, M. S ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2016
    Abstract
    This paper deals with asymptotic swarm stabilization of fractional order linear time invariant swarm systems in the presence of two constraints: the input saturation constraint and the restriction on distance of the agents from final destination which should be less than a desired value. A feedback control law is proposed for asymptotic swarm stabilization of fractional order swarm systems which guarantees satisfying the above-mentioned constraints. Numerical simulation results are given to confirm the efficiency of the proposed control method  

    Asymptotic swarm stability of fractional-order swarm systems in the presence of uniform time-delays

    , Article International Journal of Control ; Volume 90, Issue 6 , 2017 , Pages 1182-1191 ; 00207179 (ISSN) Naderi Soorki, M ; Tavazoei, M. S ; Sharif University of Technology
    Taylor and Francis Ltd  2017
    Abstract
    In this paper, asymptotic swarm stability of fractional-order swarm systems in the presence of uniform time-delays is studied. By using a frequency domain approach, the necessary and sufficient condition on the values of time-delay is derived to guarantee the asymptotic swarm stability under a directed/undirected interaction graph. Numerical examples are given to confirm the obtained analytical results. © 2015 Informa UK Limited, trading as Taylor & Francis Group  

    Adaptive robust control of fractional-order swarm systems in the presence of model uncertainties and external disturbances

    , Article IET Control Theory and Applications ; Volume 12, Issue 7 , 2018 , Pages 961-969 ; 17518644 (ISSN) Naderi Soorki, M ; Tavazoei, M. S ; Sharif University of Technology
    Institution of Engineering and Technology  2018
    Abstract
    This study investigates the asymptotic swarm stabilisation of fractional-order swarm systems in the presence of two different kinds of model uncertainties and external disturbances while the upper bound of the uncertainties is a linear function of pseudo-states norms with unknown coefficients. To this end, first a fractional-integral sliding manifold is constructed and then an adaptive-robust sliding mode controller is designed to guarantee the asymptotic swarm stability in a fractional-order linear time-invariant swarm system. The stability analysis of the proposed control system is done based on the Lyapunov stability theorem. Using the proposed controller, the coefficients of the upper... 

    An optimal wavelet filtering method for noise suppression of PD measured signal and its location in power transformer winding

    , Article 2005 IEEE International Conference on Dielectric Liquids, ICDL 2005, Coimbra, 26 June 2005 through 1 July 2005 ; 2005 , Pages 269-272 ; 0780389549 (ISBN); 9780780389540 (ISBN) Naderi, M. S ; Vakilian, M ; Blackburn, T. R ; Phung, B. T ; Nam O, H ; Naderi, M. S ; Sharif University of Technology
    2005
    Abstract
    In this paper a method for selecting optimal wavelet is introduced, which is implemented for evaluating electrical measured partial discharges on a 66 kV/25 MVA fully interleaved winding of a power transformer. Applying wavelet transform to a signal produces a wavelet detail coefficient distribution throughout the time-scale, which depends on the wavelet chosen. This method is based on the capability of the chosen wavelet for generating coefficients with maximal values. The basic idea of this method is described and applications to partial discharge studies are explored. The paper demonstrates that the wavelet based de-noising method proposed in the paper can be employed in extracting the PD... 

    Probabilistic simulation of fatigue damage and life scatter of metallic components

    , Article International Journal of Plasticity ; Volume 43 , April , 2013 , Pages 101-115 ; 07496419 (ISSN) Naderi, M ; Hoseini, S. H ; Khonsari, M. M ; Sharif University of Technology
    2013
    Abstract
    A three-dimensional (3D) finite element model (FEM) is developed to predict the progressive fatigue damage with provision for stochastic distribution of material properties. Fatigue damage model for low and high cycle fatigue considering plastic deformation is implemented in the FEM and the results are presented for Al 6061-T6, Al 7075-T6, Ti 6Al-4V and SS 316. Comparisons of the numerical and experimental results of stress-life reveal the validity of the approach. Also presented is the result of an investigation showing the effect of element types, element size, variation of material properties, and initial flaws on the randomness of fatigue life. The present fatigue damage simulation... 

    Comment on S. Ahmed, H. Wang, and Y. Tian, “Robust adaptive fractional-order terminal sliding mode control for lower-limb exoskeleton,” Asian J. Control, vol. 21, no. 1, pp. 1–10 (2019)

    , Article Asian Journal of Control ; 2022 ; 15618625 (ISSN) Samaei, M. H ; Sheikh Ahmadi, S ; Naderi Soorki, M ; Amini, S. S ; Sharif University of Technology
    John Wiley and Sons Inc  2022
    Abstract
    In this comment, it is shown that there are some non-negligible big mistakes in the analyses and stability proof of the proposed controller in the quoted paper, which makes the main results of this paper to be incorrect. The main unavoidable mistakes in the stability analysis of the main theorem (Theorem 1) are stated and some remarks are also mentioned to fix some of them. © 2022 Chinese Automatic Control Society and John Wiley & Sons Australia, Ltd  

    A comparison between partial discharge propagation in multiple-α and single-α transformer winding

    , Article Electrical Insulation Conference and Electrical Manufacturing Expo, 2005, Indianapolis, IN, 23 October 2005 through 26 October 2005 ; Volume 2005 , 2005 , Pages 108-111 ; 0780391454 (ISBN); 9780780391451 (ISBN) Naderi, M. S ; Vakilian, M ; Blackburn, T. R ; Phung, B.T ; Zhang, H ; Nam O, H ; Naderi, M. S ; Sharif University of Technology
    2005
    Abstract
    Power transformers are in service in different environmental, electrical and mechanical conditions. Many experiences have proved that the inner insulation system degradation may pose the transformer to fail while in service. On the other hand, partial discharges (PD) are recognized as the main cause of insulation deterioration process. Therefore, reaching the optimum inner insulation system is one of the challenges a transformer designer is faced with. The solution lies in the correct and accurate modelling of different types of transformer windings. Transformer strength especially during transient conditions is a criterion for transformer insulation designers. This challenge has made... 

    Simulation of partial discharge propagation and location in Abetti winding based on structural data

    , Article 7th International Power Engineering Conference, IPEC2005, Singapore, 29 November 2005 through 2 December 2005 ; Volume 2005 , 2005 ; 9810544693 (ISBN); 9789810544690 (ISBN) Naderi, M. S ; Vakilian, M ; Blackburn, T. R ; Phung, B. T ; Hio, N. O ; Naderi, M. S ; Ghaemmaghami, R ; Sharif University of Technology
    IEEE Computer Society  2005
    Abstract
    Power transformer monitoring as a reliable tool for maintaining purposes of this valuable asset of power systems has always comprised partial discharge offline measurements and online monitoring. The reason lies in non-destructive feature of PD monitoring. Partial discharge monitoring helps to detect incipient insulation faults and prevent insulation failure of power transformers. This paper introduces a software package developed based on structural data of power transformer and discusses the results of the simulation on Abetti winding, which might be considered as a basic layer winding. A hybrid model is used to model the transformer winding, which has been developed by first author.... 

    Investigation of short-time artificial aeration on water quality parameters and phytoplankton structure: a case study “Mamloo Reservoir”

    , Article Desalination and Water Treatment ; Volume 254 , 2022 , Pages 217-228 ; 19443994 (ISSN) Naderi, H ; Javid, A. H ; Borghei, S. M ; Eslamizadeh, M ; Sharif University of Technology
    Desalination Publications  2022
    Abstract
    Thermal stratification accompanied by a release of nutrients from sediment is a serious problem for the management of water quality. Water aeration and mixing technology can be widely used to control endogenous pollution and algae growth in reservoirs and lakes by water quality managers. In this research, a diffuser aeration system, was installed in a water column, in the Mamloo stratified Reservoir; and the impact of artificial aeration was brought under extensive assessment in relevance with the qualitative and biological parameters of the water, during the preliminary 6 d of aeration. The results showed that the thermal stratification was remarkably disturbed. After aeration, the amount... 

    Nickel molybdate nanorods supported on three-dimensional, porous nickel film coated on copper wire as an advanced binder-free electrode for flexible wire-type asymmetric micro-supercapacitors with enhanced electrochemical performances

    , Article Journal of Colloid and Interface Science ; Volume 542 , 2019 , Pages 325-338 ; 00219797 (ISSN) Naderi, L ; Shahrokhian, S ; Sharif University of Technology
    Academic Press Inc  2019
    Abstract
    Wire-shaped micro-supercapacitors attracted extensive attentions in next-generation portable and wearable electronics, due to advantages of miniature size, lightweight and flexibility. Herein, NiMoO 4 nanorods supported on Ni film coated Cu wire are successfully fabricated thorough direct deposition of Ni film onto Cu wire as the conductive substrate, followed by growth of the NiMoO 4 nanorods on Ni film coated Cu wire substrate by means a hydrothermal annealing process. The prepared 3D, porous electrode demonstrates extremely high areal specific capacitance of 12.03F cm −2 at the current density of 4 mA cm −2 and retained capacitance of 8.23 F cm −2 at a much higher current density of 80... 

    Nickel vanadium sulfide grown on nickel copper phosphide dendrites/Cu fibers for fabrication of all-solid-state wire-type micro-supercapacitors

    , Article Chemical Engineering Journal ; Volume 392 , 15 July , 2020 Naderi, L ; Shahrokhian, S ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Herein, we have successfully fabricated NiVS/NiCuP nanostructures on Cu wire as a fiber electrode for high performance FSMSCs applications. The 3D NiCuP dendritic film was firstly deposited on Cu wire through the electrodeposition method, which not only act as a scaffold for deposition of the electroactive materials (NiV-LDH and NiV-S), but also served as a micro-porous current collector, supplied extra capacitances. Then, NiV-LDH nanosheets grown on 3D NiCuP film were obtained using a hydrothermal method. The sulfidation of NiV-LDH is carried out through an ion-exchange reaction of OH– with S2– to obtain NiVS, which maintains an ultrathin and porous structure, improves the electrical... 

    Cobalt vanadium chalcogenide microspheres decorated with dendrite-like fiber nanostructures for flexible wire-typed energy conversion and storage microdevices

    , Article Nanoscale ; Volume 14, Issue 25 , 2022 , Pages 9150-9168 ; 20403364 (ISSN) Naderi, L ; Shahrokhian, S ; Sharif University of Technology
    Royal Society of Chemistry  2022
    Abstract
    The increasing energy demand for next-generation portable and miniaturized electronics has drawn tremendous attention to develop microscale energy storage and conversion devices with light weight and flexible characteristics. Herein, we report the preparation of flower-like cobalt vanadium selenide/nickel copper selenide (CoVSe/NiCuSe) microspheres with three-dimensional hierarchical structure of micropore growth on copper wire for a flexible fiber microsupercapacitor (microSC) and overall water splitting. The CoV-LDH microspheres are anchored on the dendrite-like NiCu nanostructured Cu wire using a hydrothermal method (CoV-LDH/NiCu@CW). The sulfidation and selenization of CoV-LDH/NiCu was... 

    An empirical model for modified bituminous binder master curves

    , Article Materials and Structures/Materiaux et Constructions ; Volume 46, Issue 9 , December , 2013 , Pages 1459-1471 ; 13595997 (ISSN) Asgharzadeh, S. M ; Tabatabaee, N ; Naderi, K ; Partl, M ; Sharif University of Technology
    2013
    Abstract
    Modeling the mechanical behavior of asphalt binders and mixtures has been the subject of intensified research in recent decades. Master curves of the norm of the complex modulus |G*| in the linear viscoelastic domain are frequently used for modeling, while phase angle master curves are less frequently considered for this purpose. Therefore in this research, an empirical model is introduced for phase angle master curves of modified and neat bituminous binders. The model is based on a general form of a double-logistic (DL) mathematical function. The |GG*| master curve was then modeled using a mutual relationship between the phase angle and |GG*|. Master curves of three neat and seven modified... 

    A method for modeling power transformer tap winding for transient studies

    , Article Conference Record of IEEE International Symposium on Electrical Insulation, Indianapolis, IN, 19 September 2004 through 22 September 2004 ; 2004 , Pages 34-37 ; 01642006 (ISSN) Naderi, M. S ; Vakilian, M ; Sharif University of Technology
    2004
    Abstract
    One of the challenges a transformer designer is faced with is to correctly model the different types of transformer windings for transient study. For a precise insulation design, determination of transformer transient responses is unavoidable. The basis of these studies is calculation of transient responses due to application of standard switching and lightning impulse wave to the transformer winding. In a previous work, a computer program was developed for determination of the layer and disk type windings transient model parameters based on design data. This program has all of the necessary capabilities for a detailed transient study. As a continuation of that work, in this paper a method... 

    Investigation of partial discharge propagation and location in multiple-α and single- α transformer windings using optimized wavelet analysis

    , Article Iranian Journal of Science and Technology, Transaction B: Engineering ; Volume 30, Issue 6 , 2006 , Pages 655-666 ; 03601307 (ISSN) Salay Naderi, M ; Vakilian, M ; Blackburn, T. R ; Phung, T. B ; Salay Naderi, M ; Sharif University of Technology
    2006
    Abstract
    Partial discharges (PD) are recognized as the main cause of the inner insulation deterioration process in power transformers. Therefore, the optimum inner insulation design is one of the challenges a transformer designer is faced with. Transformer strength, especially during transient conditions, is a criterion for transformer insulation designers. This challenge has made designers initiate and employ other types of winding, for example, rather than ordinary layer and disc windings employ the multiple-α windings. Multiple-α windings have a more complicated structure and are comprised of various parts with different physical structures and electrical characteristics. Typical partial discharge... 

    Extreme bendability of DNA double helix due to bending asymmetry

    , Article Journal of Chemical Physics ; Volume 143, Issue 10 , 2015 ; 00219606 (ISSN) Salari, H ; Eslami Mossallam, B ; Naderi, S ; Ejtehadi, M. R ; Sharif University of Technology
    American Institute of Physics Inc  2015
    Abstract
    Experimental data of the DNA cyclization (J-factor) at short length scales exceed the theoretical expectation based on the wormlike chain (WLC) model by several orders of magnitude. Here, we propose that asymmetric bending rigidity of the double helix in the groove direction can be responsible for extreme bendability of DNA at short length scales and it also facilitates DNA loop formation at these lengths. To account for the bending asymmetry, we consider the asymmetric elastic rod (AER) model which has been introduced and parametrized in an earlier study [B. Eslami-Mossallam and M. R. Ejtehadi, Phys. Rev. E 80, 011919 (2009)]. Exploiting a coarse grained representation of the DNA molecule... 

    Evaluation of rheological master curve models for bituminous binders

    , Article Materials and Structures/Materiaux et Constructions ; Volume 48, Issue 1-2 , January , 2015 , Pages 393-406 ; 13595997 (ISSN) Asgharzadeh, S. M ; Tabatabaee, N ; Naderi, K ; Partl, M. N ; Sharif University of Technology
    Kluwer Academic Publishers  2015
    Abstract
    Master curves of asphalt binders and mixtures have been traditionally used to evaluate their rheological behavior in the linear viscoelastic range. Different analytical models are available to describe the master curves of bituminous binders and mixtures. No models are currently considered universal for all modeling purposes. In this research, the general structure and capabilities of some of the most commonly used analytical models were investigated. Then, based on the patterns of phase angle master curves of ten neat and modified asphalt binders, four groups of master curve shapes were defined. The goodness of fit of the models for the different groups of master curves was used to develop... 

    Optimization of a new activated carbon based sorbent for on-line preconcentration and trace determination of nickel in aquatic samples using mixed-level orthogonal array design

    , Article Analyst ; Volume 125, Issue 9 , 2000 , Pages 1649-1654 ; 00032654 (ISSN) Bagheri, H ; Saraji, M ; Naderi, M ; Sharif University of Technology
    Royal Society of Chemistry  2000
    Abstract
    A mini-column was made by packing α-diphenylglyoxime (DPG), a known ligand for complexation with nickel ions, loaded on activated charcoal (AC). Water samples were buffered at the pH range 8-9 and then passed through the column. After the preconcentration step, the column was eluted with 0.2 M nitric acid into the atomic absorption spectrometer (AAS). Mixed-level orthogonal array design (OAD) was used as a chemometric approach to study the effect of various factors on recovery of extraction. Factors such as pH, amount of sorbent, flow rate of sample, concentration and volume of the sample were investigated. Effects of interference ions, i.e., Co, Cu, Bi, Fe(I1), Pt and Pd was also studied....