Loading...
Search for:
shanehsazzadeh--f
0.114 seconds
Total 3979 records
Shielding factor enhancement method for bi-stage active shield in SQUID-based magnetocardiography system
, Article 29th Iranian Conference on Electrical Engineering, ICEE 2021, 18 May 2021 through 20 May 2021 ; 2021 , Pages 129-133 ; 9781665433655 (ISBN) ; Esmaeili, F ; Shanehsazzadeh, F ; Fardmanesh, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2021
Abstract
We proposed a simple method to enhance shielding factor of our previously proposed bi-stage active shield system employed in a SQUID-based magnetocardiography system. The additional proposed design is optimized for canceling the power-line magnetic interference field to provide a calmer magnetic environment for the bi-stage active shield. A 50 Hz cancellation coil is placed around the bi-stage shielding system which includes inner and outer coils designed for compensating low-frequency (0-0.1Hz) and high-frequency (0.1-100Hz) environmental magnetic noise, respectively. In this configuration, a SQUID magnetometer is located at the center of these coils. Considering that the power-line...
Shielding factor enhancement method for Bi-stage active shield in SQUID-based magnetocardiography system
, Article 29th Iranian Conference on Electrical Engineering, ICEE 2021, 18 May 2021 through 20 May 2021 ; 2021 , Pages 129-133 ; 9781665433655 (ISBN) ; Esmaeili, F ; Shanehsazzadeh, F ; Fardmanesh, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2021
Abstract
We proposed a simple method to enhance shielding factor of our previously proposed bi-stage active shield system employed in a SQUID-based magnetocardiography system. The additional proposed design is optimized for canceling the power-line magnetic interference field to provide a calmer magnetic environment for the bi-stage active shield. A 50 Hz cancellation coil is placed around the bi-stage shielding system which includes inner and outer coils designed for compensating low-frequency (0-0.1Hz) and high-frequency (0.1-100Hz) environmental magnetic noise, respectively. In this configuration, a SQUID magnetometer is located at the center of these coils. Considering that the power-line...
Integrated monolayer planar flux transformer and resonator tank circuit for high-$t-{c}$ rf-squid magnetometer
, Article IEEE Transactions on Applied Superconductivity ; Volume 27, Issue 4 , 2017 ; 10518223 (ISSN) ; Jabbari, T ; Qaderi, F ; Fardmanesh, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2017
Abstract
The authors propose a new design for monolayer superconducting planar flux transformer integrated with a coplanar resonator serving as a gigahertz range tank circuit for high-Tc rf-SQUID magnetometers. Based on the proposed design, which is optimized using the finite element method, the transformer-resonator configuration is made of 200-nm-thick monolayer YBCO film on a crystalline LaAlO3 substrate. In this optimized design, the SQUID magnetometer is coupled through flip-chip configuration with the configuration providing high coupling coefficient between the devices. The design permits coupling of the rf signals to the SQUID efficiently, whereas the transformer is designed to couple the dc...
Environmental noise cancellation for high-TC SQUID-based magnetocardiography systems using a bistage active shield
, Article IEEE Transactions on Applied Superconductivity ; 2017 ; 10518223 (ISSN) ; Kalantari, N ; Sarreshtedari, F ; Fardmanesh, M ; Sharif University of Technology
2017
Abstract
An active noise cancellation method is proposed for superconducting quantum interference devices (SQUID)-based magnetocardiography systems working out of magnetically shielded rooms. Using YBCO high-Tc rf-SQUID magnetometers as magnetic field sensors, an active shielding system was implemented based on this method. This method incorporates two different shielding frequency regimes of operation simultaneously. This is because the unwanted background magnetic field signals range from very low frequencies up to high frequencies with a wide range of amplitudes at the upper and lower frequency spectra. Therefore, the shielding system is designed in a bistage configuration, and each stage covers...
Modified Gadonanotubes as a promising novel MRI contrasting agent
, Article DARU, Journal of Pharmaceutical Sciences ; Volume 21, Issue 1 , 2013 ; 15608115 (ISSN) ; Atyabi, F ; Shanehsazzadeh, S ; Sobhani, Z ; Adeli, M ; Dinarvand, R ; Sharif University of Technology
2013
Abstract
Background and purpose of the study. Carbon nanotubes (CNTs) are emerging drug and imaging carrier systems which show significant versatility. One of the extraordinary characteristics of CNTs as Magnetic Resonance Imaging (MRI) contrasting agent is the extremely large proton relaxivities when loaded with gadolinium ion (Gdn 3+) clusters. Methods. In this study equated Gdn 3+ clusters were loaded in the sidewall defects of oxidized multiwalled (MW) CNTs. The amount of loaded gadolinium ion into the MWCNTs was quantified by inductively coupled plasma (ICP) method. To improve water solubility and biocompatibility of the system, the complexes were functionalized using diamine-terminated...
Low noise active shield for SQUID-Based mag-netocardiography systems
, Article IEEE Transactions on Applied Superconductivity ; 2017 ; 10518223 (ISSN) ; Fardmanesh, M ; Sharif University of Technology
2017
Abstract
light weight and low-cost active magnetic shield sys-tem is proposed for a single channel SQUID-based magnetocardiog-raphy system equipped for operating at liquid nitrogen temperature without passive magnetic shield. The developed active shield, using coils around the sensors, is a two-stage magnetic shielding system, each stage of which has been designed to compensate different fre-quency and dynamic ranges. The sensor part contains two high-Tc rf-SQUID magnetometers, capable of working stably under earth magnetic field, placed in an axial gradiometric arrangement with a baseline of 10 cm. The active shield setup is driven using two corre-lated proportional-integral-derivative closed loop...
Low noise active shield for SQUID-based magnetocardiography systems
, Article IEEE Transactions on Applied Superconductivity ; Volume 28, Issue 4 , 2018 ; 10518223 (ISSN) ; Fardmanesh, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2018
Abstract
A light weight and low-cost active magnetic shield system is proposed for a single channel SQUID-based magnetocardiography system equipped for operating at liquid nitrogen temperature without passive magnetic shield. The developed active shield, using coils around the sensors, is a two-stage magnetic shielding system, each stage of which has been designed to compensate different frequency and dynamic ranges. The sensor part contains two high-Tc rf-SQUID magnetometers, capable of working stably under earth magnetic field, placed in an axial gradiometric arrangement with a baseline of 10 cm. The active shield setup is driven using two correlated proportional-integral-derivative closed loop...
Design and Optimization of HTS SQUID based Magnetocardiography using Active Shield
, Ph.D. Dissertation Sharif University of Technology ; Fardmanesh, Mehdi (Supervisor)
Abstract
In this work, we report on a developed single-channel high-Tc SQUID based MCG system for operation in unshielded environment. In brief, our system consists of a liquid Nitrogen Dewar and two high-Tc rf-SQUID capsuled in a holding probe,which is connected via coaxial cables to our multichannel rf-SQUID readout electronics.The rf-SQUIDs were patterned from about 200 nm△10 nm thick YBCO films sputtered on 1 mm thick LaAlO3 substrates. The holding probe integrates rf-SQUIDs, LC resonant circuits, and shielding coils. We have investigated the effects of the lumped element tank circuit resonator parameters on the rf-SQUID signal characteristics and based on the simulation and experimental...
Evaluating the effect of ultrasmall superparamagnetic iron oxide nanoparticles for a long-term magnetic cell labeling
, Article Journal of Medical Physics ; Volume 38, Issue 1 , 2013 , Pages 34-40 ; 09716203 (ISSN) ; Oghabian, M. A ; Allen, B. J ; Amanlou, M ; Masoudi, A ; Daha, F. J ; Sharif University of Technology
2013
Abstract
In order to evaluate the long-term viability, the iron content stability, and the labeling efficiency of mammalian cells using magnetic cell labeling; dextran-coated ultrasmall superparamagnetic iron oxide (USPIOs) nanoparticles with plain surfaces having a hydrodynamic size of 25 nm were used for this study. Tests were carried out in four groups each containing 5 flasks of 5.5 × 10 6 AD-293 embryonic kidney cells. The cell lines were incubated for 24 h using four different iron concentrations with and without protamine sulfate (Pro), washed with phosphate-buffered saline (PBS) and centrifuged three times to remove the unbounded USPIOs. Cell viability was also verified using USPIOs. There...
Excitation current optimization of fluxgate magnetometers for active magnetic shielding of SQUID-Based magnetocardiography system
, Article Journal of Superconductivity and Novel Magnetism ; 2016 , Pages 1-6 ; 15571939 (ISSN) ; Kalantari, N ; Jabbari, T ; Fardmanesh, M ; Sharif University of Technology
Springer New York LLC
2016
Abstract
In order to achieve stable operation for a developed high-Tc SQUID-based magnetocardiography system, a two-stage active magnetic shielding technique is implemented. This technique is based on a combination of fluxgate and high-Tc SQUID magnetometers feedback loops. While two YBCO rf SQUIDs in a gradiometric configuration are used at liquid Nitrogen temperature as the main sensors for the heart signal detection and low-amplitude noise signals cancellation in one stage, a fluxgate is used to cancel large far-field environmental noise in the other stage feedback loop. The fluxgate sensors working in the fundamental mode under the optimized bias conditions have white noise levels less than 10...
Design and optimization of feedback control system for active shielding of HTS RF-SQUID based MCG
, Article 24th Iranian Conference on Electrical Engineering, ICEE 2016, 10 May 2016 through 12 May 2016 ; 2016 , Pages 457-459 ; 9781467387897 (ISBN) ; Majzoubi, M ; Kalantari, N ; Fardmanesh, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2016
Abstract
A High Tc RF-SQUID Based magnetocardiography system is developed for operating in a passively unshielded environment, in which active shielding is implemented to compensate field noises for the low to midrange frequency range. The main part of the implemented active shield configuration is a feedback control system designed for environmental noise cancelation in particular that of the power lines. This control system includes two layers of inner and outer compensation coils with respect to the liquid Nitrogen Dewar as parts of the designed active shield. The inner coils are surrounding the HTS SQUIDs which are placed in axial gradiometric configuration inside the dewar. The outer coils are...
Excitation current optimization of fluxgate magnetometers for active magnetic shielding of SQUID-based magnetocardiography system
, Article Journal of Superconductivity and Novel Magnetism ; Volume 30, Issue 8 , 2017 , Pages 2323-2328 ; 15571939 (ISSN) ; Kalantari, N ; Jabbari, T ; Fardmanesh, M ; Sharif University of Technology
2017
Abstract
In order to achieve stable operation for a developed high-Tc SQUID-based magnetocardiography system, a two-stage active magnetic shielding technique is implemented. This technique is based on a combination of fluxgate and high-Tc SQUID magnetometers feedback loops. While two YBCO rf SQUIDs in a gradiometric configuration are used at liquid Nitrogen temperature as the main sensors for the heart signal detection and low-amplitude noise signals cancellation in one stage, a fluxgate is used to cancel large far-field environmental noise in the other stage feedback loop. The fluxgate sensors working in the fundamental mode under the optimized bias conditions have white noise levels less than 10...
Design and Fabrication of Brain Spinal Cord Electrodes for Rehabilitation of Rats with Spinal Cord Injuries
, M.Sc. Thesis Sharif University of Technology ; Fardmanesh, Mehdi (Supervisor) ; Shanehsazzadeh, Faezeh (Co-Supervisor)
Abstract
The use of microelectrode arrays in neural networks has offered a wonderful opportunity for evaluating numerous properties and interactions with excitable tissues such as the brain and spinal cord in the laboratory. In neural network applications, microelectrode arrays can be utilized to analyze nerve impulses or interact with neurons. They are either used to record neural data or to stimulate spinal cord nerves. Previous research has revealed that stimulating the spinal epidural region can help restore after spinal cord injuries (SCIs), which is the key to using them in the rehabilitation of living beings, including humans. According to the international campaign for the treatment of SCI...
Synthesizing and staining manganese oxide nanoparticles for cytotoxicity and cellular uptake investigation
, Article Biochimica et Biophysica Acta - General Subjects ; Vol. 1840, Issue. 1 , 2014 , pp. 428-433 ; ISSN: 03044165 ; Oghabian, M. A ; Ahmadi, R ; Shahbazi, N ; Hosseini, H. R. M ; Shanehsazzadeh, S ; Zangeneh, R. N ; Sharif University of Technology
2014
Abstract
Background For decades, contrast agents have been used to reduce longitudinal (T1) or transverse (T2) relaxation times. High toxicity of gadolinium-based contrast agents leads researchers to new T1 contrast agents. Manganese oxide (MnO) nanoparticle (NP) with the lower peril and good enough signal change ability has been offered as a new possibility for magnetic resonance imaging (MRI). Methods The synthesized NPs were investigated for physicochemical and biological properties by X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscope, dynamic light scattering (DLS), inductively coupled plasma, enzyme-linked immunosorbent assay, and 3 T magnetic resonance...
Graphene/cobalt nanocarrier for hyperthermia therapy and MRI diagnosis
, Article Colloids and Surfaces B: Biointerfaces ; Volume 146 , 2016 , Pages 271-279 ; 09277765 (ISSN) ; Ahadian, M. M ; Ghiass, M. A ; Iraji zad, A ; Saber, R ; Parseh, B ; Oghabian, M. A ; Shanehsazzadeh, S ; Sharif University of Technology
Elsevier
2016
Abstract
Graphene/cobalt nanocomposites are promising materials for theranostic nanomedicine applications, which are defined as the ability to diagnose, provide targeted therapy and monitor the response to the therapy. In this study, the composites were synthesized via chemical method, using graphene oxide as the source material and assembling cobalt nanoparticles of 15 nm over the surface of graphene sheets. Various characterization techniques were then employed to reveal the morphology, size and structure of the nanocomposites, such as X-ray diffraction analysis, X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, high resolution transmission electron microscopy and...
Effect of heating profile on desorption curve in temperature programmed desorption analysis: Case study of acid sites distribution of SAPO-34
, Article Journal of Porous Materials ; Volume 16, Issue 5 , 2009 , Pages 599-603 ; 13802224 (ISSN) ; Farhadi, F ; Khorasheh, F ; Yan, Z. F ; Sharif University of Technology
2009
Abstract
Comparison of the traditional linear heating method of TPD with an original stepwise heating scheme was reported for the first time. Stepwise heating TPD was carried out by keeping the temperature constant as soon as ammonia desorption signal rises until the signal returns to the baseline. More ammonia desorption peaks on a SAPO-34 catalyst were identified using TPD with stepwise heating. The effect of temperature ramp on desorption peak broadening in TPD curve was also addressed. The more distinct ammonia desorption peaks in stepwise TPD indicates that ammonia adsorbs in about five or six different ways on SAPO-34, and attribution of different adsorptions may be explained considering some...
Theoretical and experimental study of cascade solar stills
, Article Solar Energy ; Volume 90 , April , 2013 , Pages 205-211 ; 0038092X (ISSN) ; Sharak, A. Z ; Moghadam, H ; Tabrizi, F. F ; Sharif University of Technology
2013
Abstract
Most part of Iran is dominated by arid and semi-arid areas due to low annual rainfall. The need for production of fresh water from brackish water is considerably high, especially in dry regions. In this study 1 month daily-based experimental data from a solar still site has been reported. The technical and operational problems of this site which finally contributed to the total cease of the site are described. Then a detailed analysis is investigated on progress of a prototype which constructed in order to solve the site's problems. The results of 1 month of experimental data of the final design showed that the last prototype could be used to solve the current problems of the site. The...
Application of a continuous kinetic model for the hydrocracking of vacuum gas oil
, Article Petroleum Science and Technology ; Vol. 32, Issue. 18 , 2014 , Pages 2245-2252 ; ISSN: 10916466 ; Khorasheh, F ; Farhadi, F ; Sharif University of Technology
2014
Abstract
Hydrocracking is one of the most versatile petroleum refining processes for production of valuable products including gasoline, gas oil, and jet fuel. In this paper, a five-parameter continuous lumping model was used for kinetic modeling of hydrocracking of vacuum gas oil (VGO). The model parameters were estimated from industrial data obtained from a fixed bed reactor operating at an average temperature of 400°C and residence time of 0.3 h. Product distributions were obtained in terms of the weight fraction of various boiling point cuts. The model parameters were estimated using the Nelder-Mead optimization procedure and were correlated with temperature. Comparison of experimental and...
An improved methodology for design of custom-made hip prostheses to be fabricated using additive manufacturing technologies
, Article Rapid Prototyping Journal ; Volume 18, Issue 5 , 2012 , Pages 389-400 ; 13552546 (ISSN) ; Abbaszadeh, F ; Farahmand, F ; Sharif University of Technology
Emerald
2012
Abstract
Purpose - The purpose of this paper is to present an improved methodology for design of custom-made hip prostheses, through integration of advanced image processing, computer aided design (CAD) and additive manufacturing (AM) technologies. Design/methodology/approach - The proposed methodology for design of custom-made hip prostheses is based on an independent design criterion for each of the intra-medullary and extra-medullary portions of the prosthesis. The intra-medullar part of the prosthesis is designed using a more accurate and detailed description of the 3D geometry of the femoral intra-medullary cavity, including the septum calcar ridge, so that an improved fill and fit performance...
Evaluation and enhancing of operational performance and training objective in accordance with Line Operations Safety Audit (LOSA)
, Article International Air Safety Seminar Proceedings, 1 November 2011 through 3 November 2011 ; November , 2011 , Pages 78-99 ; 02705176 (ISSN) ; 9781618393975 (ISBN) ; Goodarzi, F ; Sharafbafi, F ; Sharif University of Technology
2011