Loading...
Search for:
zarei--s--a
0.113 seconds
Total 20766 records
What drives mergers and acquisitions waves in developing countries? Evidences from Iranian banking industry
, Article Iranian Economic Review ; Volume 19, Issue 2 , 2015 , Pages 123-137 ; 10266542 (ISSN) ; Alambeigi, A ; Karimi, P ; Zarei, B ; Sharif University of Technology
2015
Abstract
Many Middle-East countries, like Iran, have dynamic banking industries and have observed merger and acquisitions (M&A) waves. M&A waves are usually defined in the developed world context and some of their main drivers were identified as: market timing, environment's shocks, merger manias, government regulation and regulatory, and technological changes. It has been discussed that merger waves and their reasons are among the ten most important unsolved mysteries in the field of finance (Brealey and Myers, 1991, p. 923), and as a result of this, it was not possible to completely clarify the reasons behind emerging M&A waves, especially in developing countries; for this reason in these...
The effects of mergers and acquisitions (M&As) on bank performance and entrepreneurial orientation (EO)
, Article Iranian Entrepreneurship: Deciphering the Entrepreneurial Ecosystem in Iran and in the Iranian Diaspora ; 2017 , Pages 361-375 ; 9783319506395 (ISBN); 9783319506388 (ISBN) ; Alambeigi, A ; Zarei, B ; Karimi, P ; Sharif University of Technology
Springer International Publishing
2017
Abstract
This chapter aims at pointing out that how mergers and acquisitions (M&As) as popular strategies which they are based on external growth approach have affected the performance of banks and entrepreneurial orientation (EO) in the context of Iranian financial sector. In this regard, it has been tried to investigate in what way EO moderates the relationships between the performance of banks in one hand, and M&As on the other hand. For this goal, 114 participants including the top and middle managers of the Iranian banks were chosen to be closely considered. The research is an applied research and a cross-correlation methodology has been used to spotlight on the probable relationships between EO...
Enhanced control of grid forming VSCs in a micro-grid system under unbalanced conditions
, Article 9th Annual International Power Electronics, Drive Systems, and Technologies Conference, PEDSTC 2018, 13 February 2018 through 15 February 2018 ; Volume 2018-January , April , 2018 , Pages 380-385 ; 9781538646977 (ISBN) ; Mokhtari, H ; Ghasemi, M. A ; SHarif University of Technology
Institute of Electrical and Electronics Engineers Inc
2018
Abstract
Due to the technical advances in power electronic industry, employing inverter-based distributed energy resources (IBDERs) are increased in electric power systems. Distributed generators (DGs) with the rating capacity of few megawatts are commonly connected to the distribution level of power systems which are inherently unbalanced. A cluster of IBDERs and loads form a small-scale grid called microgrid (MG) which can operate independent of the main grid. In a MG, grid forming voltage source converters (VSCs) are used to control the voltages and frequency of the MG. However, grid forming VSCs with conventional control schemes cannot do this task properly when the MG is unbalanced. In this...
A simple, faster method for kinetic proximity problems
, Article Computational Geometry: Theory and Applications ; Volume 48, Issue 4 , 2015 , Pages 342-359 ; 09257721 (ISSN) ; Abam, M. A ; King, V ; Whitesides, S ; Zarei, A ; Sharif University of Technology
Elsevier
2015
Abstract
For a set of n points in the plane, this paper presents simple kinetic data structures (KDSs) for solutions to some fundamental proximity problems, namely, the all nearest neighbors problem, the closest pair problem, and the Euclidean minimum spanning tree (EMST) problem. Also, the paper introduces KDSs for maintenance of two well-studied sparse proximity graphs, the Yao graph and the Semi-Yao graph. We use sparse graph representations, the Pie Delaunay graph and the Equilateral Delaunay graph, to provide new solutions for the proximity problems. Then we design KDSs that efficiently maintain these sparse graphs on a set of n moving points, where the trajectory of each point is assumed to be...
Conceptual hydrosalinity model for prediction of salt load from wastewater flows into soil and ground water
, Article International Journal of Environmental Science and Technology ; Volume 6, Issue 3 , 2009 , Pages 359-368 ; 17351472 (ISSN) ; Mirbagheri, S. A ; Monavvari, M ; Javid, A. H ; Zarei, H ; Sharif University of Technology
2009
Abstract
Dynamic hydrosalinity models are available, but are not used extensively on a large scale soil which receives wastewater from industrial areas, partly because adequate database are expensive to be obtained. Thus, for this reason, there is an urgent need to assess the salt and other pollutant loads collected in wastewater flows into the soil and/ or ground water systems. A conceptual hydrosalinity model was used on two major underlying principals of mass balance and steady state. This model was initially tested on the 4,117 km2 plains west of the Yazd-Ardakan district in the central part of Iran. This model was used at a time when the soil and ground water salinity problem was serious due to...
Reinforcing fault ride through capability of grid forming voltage source converters using an enhanced voltage control scheme
, Article IEEE Transactions on Power Delivery ; Volume 34, Issue 5 , 2019 , Pages 1827-1842 ; 08858977 (ISSN) ; Mokhtari, H ; Ghasemi, M. A ; Blaabjerg, F ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2019
Abstract
Medium power distributed energy resources (DERs) are commonly connected to medium voltage distribution systems via voltage source converters (VSCs). Several guidelines and standards have been developed to establish the needed criteria and requirements for DERs interconnections. In this respect, it is preferred to reinforce the VSC fault ride through (FRT) capability, which considerably minimizes the DG outage period and reconnection time and results in a resilient system against short circuits. Considering the significant number of asymmetrical faults in distribution systems, the VSC response in such conditions must be investigated, and consequently, its FRT capability must be reinforced. In...
Improving physio-mechanical and biological properties of 3D-printed PLA scaffolds via in-situ argon cold plasma treatment
, Article Scientific Reports ; Volume 13, Issue 1 , 2023 ; 20452322 (ISSN) ; Sayedain, S ; Askarinya, A ; Sabbaghi, M ; Alizadeh, R ; Sharif University of Technology
Nature Research
2023
Abstract
As a bone tissue engineering material, polylactic acid (PLA) has received significant attention and interest due to its ease of processing and biocompatibility. However, its insufficient mechanical properties and poor wettability are two major drawbacks that limit its extensive use. For this purpose, the present study uses in-situ cold argon plasma treatment coupled with a fused deposition modeling printer to enhance the physio-mechanical and biological behavior of 3D-printed PLA scaffolds. Following plasma treatment, field emission scanning electron microscopy images indicated that the surface of the modified scaffold became rough, and the interlayer bonding was enhanced. This resulted in...
A comprehensive digital protection scheme for low-voltage microgrids with inverter-based and conventional distributed generations
, Article IEEE Transactions on Power Delivery ; Volume 32, Issue 1 , 2017 , Pages 441-452 ; 08858977 (ISSN) ; Parniani, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2017
Abstract
Microgrid (MG) protection is one of the main challenges in proliferation of microgrids. Due to limited fault current feeding of inverter-based distributed generations (DGs), in islanded operation of MG, protection problems become more complicated; and, therefore, conventional protection strategies cannot be applied. Hence, new protection methods that are applicable in islanded and grid-connected modes of operation are necessary. In this paper, a comprehensive digital-relay based protection is introduced for the protection of MGs. The proposed method includes protection of lines, distributed generations, and the point of common coupling. The structure and graphical schematic of the proposed...
Formation of Zn-Ca-Ni tri cation's phosphate coating on steel and study that properties
, Article TMS 2009 - 138th Annual Meeting and Exhibition, San Francisco, CA, 15 February 2009 through 19 February 2009 ; Volume 1 , 2009 , Pages 615-623 ; 9780873397384 (ISBN) ; Afshar, A ; Sharif University of Technology
2009
Abstract
A new Zinc phosphating bath, which produces coatings at relatively lower temperatures within a reasonable time by using of chemical accelerators has been devised. Improvement of the bath performance by the addition of divalent cations like calcium, nickel has been studied. Bath formulation and operating conditions have been optimized by coating weight determinations. Stable samples of phosphating formulations with and without calcium and nickel salts were prepared and the structure and morphology of the phosphate coatings were determined by using X-ray diffraction (XRD) techniques, scanning electron microscopy. ASTMB117 salt spray test and electrochemical impedance spectroscopy (EIS) were...
Computational inverse design for cascaded systems of metasurface optics: comment
, Article Optics Express ; Volume 30, Issue 20 , 2022 , Pages 36966-37005 ; 10944087 (ISSN) ; Khavasi, A ; Sharif University of Technology
Optica Publishing Group (formerly OSA)
2022
Abstract
In a recently published article by Backer [Opt. Express 27(21), 30308 (2019).], a computational inverse design method is developed for designing optical systems composed of multiple metasurfaces. The forward propagation model used in this method was a discretized version of the angular spectrum propagator described by Goodman [Introduction to Fourier Optics, 1996]. However, slight modifications are necessary to increase the accuracy of this inverse design method. This comment examines the accuracy of the results obtained by the above-mentioned method by a full-wave electromagnetic solver and explains the reason of their difference. Thereafter, slight modifications to the method proposed by...
Touring disjoint polygons problem is NP-hard
, Article Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics) Volume 8287 LNCS, 2013, Pages 351-360 ; Volume 8287 , 2013 , Pages 351-360 ; 03029743 (ISSN) ; 9783319037790 (ISBN) ; Mozafari, A ; Zarei, A ; Sharif University of Technology
2013
Abstract
In the Touring Polygons Problem (TPP) there is a start point s, a sequence of simple polygons P = (P1,...,Pk) and a target point t in the plane. The goal is to obtain a path of minimum possible length that starts from s, visits in order each of the polygons in P and ends at t. This problem has a polynomial time algorithm when the polygons in P are convex and is NP-hard in general case. But, it has been open whether the problem is NP-hard when the polygons are pairwise disjoint. In this paper, we prove that TPP is also NP-hard when the polygons are pairwise disjoint in any Lp norm even if each polygon consists of at most two line segments. This result solves an open problem from STOC '03 and...
Touring a sequence of disjoint polygons: Complexity and extension
, Article Theoretical Computer Science ; Vol. 556, Issue. C , October , 2014 , pp. 45-54 ; ISSN: 03043975 ; Mozafari, A ; Zarei, A ; Sharif University of Technology
2014
Abstract
In the Touring Polygons Problem (TPP) there is a start point s, a sequence of simple polygons P=(P1,. . .,Pk) and a target point t in the plane. The goal is to obtain a path of minimum possible length that starts from s, visits in order each of the polygons in P and ends at t. This problem was introduced by Dror, Efrat, Lubiw and Mitchell in STOC '03. They proposed a polynomial time algorithm for the problem when the polygons in P are convex and proved its NP-hardness for intersecting and non-convex polygons. They asked as an open problem whether TPP is NP-hard when the polygons are pairwise disjoint. In this paper, we prove that TPP is also NP-hard when the polygons are pairwise disjoint in...
Touring convex polygons in polygonal domain fences
, Article 11th International Conference on Combinatorial Optimization and Applications, COCOA 2017, 16 December 2017 through 18 December 2017 ; Volume 10628 LNCS , 2017 , Pages 61-75 ; 03029743 (ISSN); 9783319711461 (ISBN) ; Mozafari, A ; Zarei, A ; Sharif University of Technology
Springer Verlag
2017
Abstract
In the touring polygons problem (TPP), for a given sequence (s= P0, P1, ⋯, Pk, t = Pk+1) of polygons in the plane, where s and t are two points, the goal is to find a shortest path that starts from s, visits each of the polygons in order and ends at t. In the constrained version of TPP, there is another sequence (F0, ⋯, Fk) of polygons called fences, and the portion of the path from Pi to Pi+1 must lie inside the fence Fi. TPP is NP-hard for disjoint non-convex polygons, while TPP and constrained TPP are polynomially solvable when the polygons are convex and the fences are simple polygons. In this work, we present the first polynomial time algorithm for solving constrained TPP when the...
Characterization of proportional-integral-resonant compensator for DC link voltage control
, Article 2018 IEEE 19th Workshop on Control and Modeling for Power Electronics, COMPEL 2018, 25 June 2018 through 28 June 2018 ; 2018 ; 9781538655412 (ISBN) ; Ghasemi, M. A ; Peyghami, S ; Davari, P ; Mokhtari, H ; Blaabjerg, F ; Sharif University of Technology
2018
Abstract
Voltage unbalance and short circuits in distribution networks adversely affect the performance of grid-tied voltage source inverters (VSIs). Consequently, the dc-link voltage ripple may significantly increase leading to operation of VSI in an unsatisfactory manner. Conventionally in order to maintain the negative sequence current under unbalanced conditions, low-pass/trap filter in the current control loop are required which significantly reduce the controller bandwidth. In order to minimize the dc-link voltage ripple without impairing the controller bandwidth, this paper investigates the design and performance of Proportional-Integral-Resonant (PIR) controller in improving the performance...
DC-link loop bandwidth selection strategy for grid-connected inverters considering power quality requirements
, Article International Journal of Electrical Power and Energy Systems ; Volume 119 , 2020 ; Mokhtari, H ; Ghasemi, M. A ; Peyghami, S ; Davari, P ; Blaabjerg, F ; Sharif University of Technology
Elsevier Ltd
2020
Abstract
DC-link voltage and output current control loops are two cascaded loops in the control structure of grid-connected inverters. A high DC-link voltage loop bandwidth (DCL-BW) provides more disturbance rejection capability for the control loop and is preferred from control system perspective. However, for stability issues, this BW is limited and must be sufficiently less than that of the current control loop. Among the different control schemes, instantaneous active reactive control (IARC) method provides the highest possible DCL-BW (i.e., 0.02 × switching frequency). Having this degree of freedom in the controller design, a proper methodology should be defined for selection of DCL-BW. In this...
Control of grid-following inverters under unbalanced grid conditions
, Article IEEE Transactions on Energy Conversion ; Volume 35, Issue 1 , 2020 , Pages 184-192 ; Mokhtari, H ; Ghasemi, M. A ; Peyghami, S ; Davari, P ; Blaabjerg, F ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2020
Abstract
This paper proposes a new control scheme to eliminate the 3rd harmonic in the output currents of grid-following inverters under unbalanced grid conditions. Unbalanced grids adversely affect the performance of grid-following inverters due to the oscillations appearing on the DC-link voltage with a frequency twice the line frequency. The paper is based on instantaneous active reactive control (IARC) technique due to its advantages over other existing methods. However, the presence of severe asymmetrical 3rd harmonic distortions in the inverter output currents is the main challenge with IARC method, which impairs the power quality requirements. This paper enhances the IARC scheme by proposing a...
Practical method to predict an upper bound for minimum variance track-to-track fusion
, Article IET Signal Processing ; Volume 11, Issue 8 , 2017 , Pages 961-968 ; 17519675 (ISSN) ; Malaek, S. M. B ; Sharif University of Technology
2017
Abstract
This study deals with the problem of track-to-track fusion in a sensor network when the correlation terms between the estimates of the agents are unknown. The proposed method offers an upper bound for the optimal minimum variance fusion rule through construction of the correlation terms according to an optimisation scheme. In general, the upper bound filter provides an estimate that is more conservative than the optimal estimate generated by the minimum variance fusion rule, while at the same time is less conservative than one obtained by the widely used covariance intersection method. From the geometrical viewpoint, the upper bound filter results in the inscribed largest volume ellipsoid...
Motion estimation of uncooperative space objects: A case of multi-platform fusion
, Article Advances in Space Research ; Volume 62, Issue 9 , 2018 , Pages 2665-2678 ; 02731177 (ISSN) ; Malaek, S. M. B ; Sharif University of Technology
Elsevier Ltd
2018
Abstract
This work describes an efficient technique to sequentially combine estimates resulting from individual sets of measurements provided by a network of satellites. The prescribed method is especially effective to estimate motion states of an uncooperative space object using range image data. The technique, which is fast and suitable for on-line applications, could also be effective to capture stray objects or those satellites that require periodic servicing. Such missions call for high degree of precision and reliable estimation methods. In fact, the proposed estimation architecture consists of a network of synchronized platforms, i.e., Observer Satellites (OS), each with processing power and...
Exact solution of generalized cooperative susceptible-infected-removed (SIR) dynamics
, Article Physical Review E ; Volume 100, Issue 1 , 2019 ; 24700045 (ISSN) ; Moghimi Araghi, S ; Ghanbarnejad, F ; Sharif University of Technology
American Physical Society
2019
Abstract
In this paper, we introduce a general framework for coinfection as cooperative susceptible-infected-removed (SIR) dynamics. We first solve the SIR model analytically for two symmetric cooperative contagions [L. Chen, Europhys. Lett. 104, 50001 (2013)10.1209/0295-5075/104/50001] and then generalize and solve the model exactly in the symmetric scenarios for three and more cooperative contagions. We calculate the transition points and order parameters, i.e., the total number of infected hosts. We show that the behavior of the system does not change qualitatively with the inclusion of more diseases. We also show analytically that there is a saddle-node-like bifurcation for two cooperative SIR...
Fault detection and protection strategy for islanded inverter-based microgrids
, Article IEEE Journal of Emerging and Selected Topics in Power Electronics ; 2019 ; 21686777 (ISSN) ; Mokhtari, H ; Blaabjerg, F ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2019
Abstract
This paper proposes a fault detection and protection strategy for islanded inverter-based microgrids (IBMGs). Reliable and accurate protection is one of the main challenges in the proliferation of modern microgrids (MGs). Considering the limited fault current of the voltage-frequency controlled inverter-based distributed energy resources (VF-IBDERs), the protection is more challenging in islanded IBMGs. In this regard, the control scheme of VF-IBDER with a current limiting strategy plays an important role. Due to the limited fault currents close to the converter nominal current, the conventional fault detection methods do not work properly. In addition, bi-directional fault currents worsen...