Loading...

Experimental and Theoretical Investigation of Microdroplet Breakup at Asymmetric T Junctions

Samie, Milad | 2013

706 Viewed
  1. Type of Document: M.Sc. Thesis
  2. Language: Farsi
  3. Document No: 44090 (08)
  4. University: Sharif University of Technology
  5. Department: Mechanical Engineering
  6. Advisor(s): Behshad Shafii, Mohammad
  7. Abstract:
  8. Symmetric T junctions have been used widely in microfluidics to generate equal-sized microdroplets, which are applicable in drug delivery systems. A newly proposed method for generating unequal-size microdroplets at a T junction is investigated theoretically and experimentally. Asymmetric T junctions with branches of identical lengths and different cross-sections are utilized for this aim. A novel equation for the critical breakup of droplets at asymmetric T junctions and one for determining the breakup point of droplets are developed. A good agreement was observed between the theories (novel and previous) and the experiments
  9. Keywords:
  10. Experimental Investigation ; Analytical Review ; Micro Droplet Breakup ; Asymmetric T Junction

 Digital Object List

 Bookmark