Loading...

Combined backscatter and transmission method for nuclear density gauge

Golgoun, S. M ; Sharif University of Technology | 2015

54 Viewed
  1. Type of Document: Article
  2. DOI: 10.1051/epjconf/201510002004
  3. Publisher: EDP Sciences , 2015
  4. Abstract:
  5. Nowadays, the use of nuclear density gauges, due to the ability to work in harsh industrial environments, is very common. In this study, to reduce error related to the ρ of continuous measuring density, the combination of backscatter and transmission are used simultaneously. For this reason, a 137Cs source for Compton scattering dominance and two detectors are simulated by MCNP4C code for measuring the density of 3 materials. Important advantages of this combined radiometric gauge are diminished influence of μ and therefore improving linear regression
  6. Keywords:
  7. Source: EPJ Web of Conferences, 23 April 2015 through 26 April 2015 ; Volume 100 , July , 2015 ; 21016275 (ISSN)
  8. URL: http://www.epj-conferences.org/articles/epjconf/abs/2015/19/epjconf_tesnat2015_02004/epjconf_tesnat2015_02004.html