Loading...

Performance Analysis, Optimization and Prototyping of Doubly Salient PM Vernier Generators

Ghods, Mehrage | 2017

606 Viewed
  1. Type of Document: M.Sc. Thesis
  2. Language: Farsi
  3. Document No: 50092 (05)
  4. University: Sharif University of Technology
  5. Department: Electrical Engineering
  6. Advisor(s): Oraee, Hashem; Nasiri-Gheidari, Zahra
  7. Abstract:
  8. In this thesis, no-load and full-load performance of Permanent Magnet Vernier Generators (PMVGs) is investigated in fully-aligned condition and under different types of mechanical faults. The studied mechanical faults are Static Eccentricity (SE), Dynamic Eccentricity (DE), Inclined Rotor (IR), and Run-out (RO). Furthermore, an analytical model is also developed to calculate the permeance of the air-gap and the induced voltages in the health machine and under studied mechanical faults. Then, 2-D and 3-D non-linear, time stepping finite element method is utilized for performance evaluation of the generator in no-load and full-load (with resistive, inductive and capacitive loads). In continue, the performance of a conventional outer rotor permanent magnet generator, considering constant dimensions, constant PM, copper and iron usage is compared with the studied PMVG. The performance of two generators are studied in fully-aligned condition as well as under SE and DE. Finally, a small PMVG is designed, optimized and built to meet power concussion requirements of road speed cameras
  9. Keywords:
  10. Finite Element Analysis ; Optimization ; Eccentricity ; Permanent Magnet Generator ; Flux Modulation ; Permanent Magnet Verner Generators ; Inclined Rotor

 Digital Object List

 Bookmark

No TOC