Loading...
Influence of different installation configurations on the position error of a multiturn wound-rotor resolver
Hajmohammadi, S ; Sharif University of Technology | 2020
513
Viewed
- Type of Document: Article
- DOI: 10.1109/JSEN.2020.2973225
- Publisher: Institute of Electrical and Electronics Engineers Inc , 2020
- Abstract:
- Multi-turn resolvers are proposed to be used in high accuracy, high-reliability applications that need to have the benefits of absolute measurement and high accuracy, simultaneously. In this paper, the influence of different arrangements of rotary transformer (RT) and resolvers' core on the accuracy of a multi-turn wound rotor (WR) resolver is discussed. Then, an optimal configuration with the aim of reducing the total cost, and the total volume of the sensor is proposed. All the analysis is done using 3-D time-variant finite element method (3-D TVFEM) and the optimal structure is built for experimental tests. Finally, experimental measurements are employed to verify the simulation results. © 2001-2012 IEEE
- Keywords:
- Design ; Multi-speed resolver ; Multi-turn resolver ; Optimal configuration ; Three-dimensional time-variant finite element method (3-D TVFEM) ; Wound-rotor (WR) resolver ; Electronics engineering ; Sensors ; Absolute measurements ; Experimental test ; High reliability ; High-accuracy ; Optimal structures ; Position errors ; Rotary transformers ; Time variant ; Structural optimization
- Source: IEEE Sensors Journal ; Volume 20, Issue 11 , 2020 , Pages 5785-5792
- URL: https://ieeexplore.ieee.org/document/8994099