Loading...

Hysteresis band determination of direct torque controlled induction motor drives with torque ripple and motor-inverter loss considerations

Kaboli, S ; Sharif University of Technology | 2003

120 Viewed
  1. Type of Document: Article
  2. Publisher: 2003
  3. Abstract:
  4. The flux and torque hysteresis bands are the only gains to be adjusted in direct torque control (DTC). The torque ripple and harmonic loss of motor and switching loss of inverter greatly Influence them. Hence, these variables must be observed in the control process to maximize performance of the system. In this paper, the effects of flux and torque hysteresis bands on inverter switching loss, harmonic loss, and torque ripple of induction motor are investigated. In order to find their optimum values, a cost function consisting motor harmonic losses, torque ripples, and inverter switching losses is defined. Minimizing this cost function leads to the optimum value of the hysteresis bands of torque and flux controllers
  5. Keywords:
  6. Torque control ; Power electronics ; Stators ; Iron ; Cost function ; Switching loss ; Hysteresis motors ; Induction motor drives ; Inverters ; Voltage
  7. Source: 2003 IEEE 34th Annual Power Electronics Specialists Conference, Acapulco, NM, 15 June 2003 through 19 June 2003 ; Volume 3 , 2003 , Pages 1107-1111 ; 02759306 (ISSN)
  8. URL: https://ieeexplore.ieee.org/document/1216604