Loading...
Search for:
hydroxyapatite
0.151 seconds
Synthesis of Hydroxyapatite Whisker and Nanorods/Polycaprolactone Composites and Scaffolds: In vitro & In vivo studies
, M.Sc. Thesis Sharif University of Technology ; Mohammadi, Mohammad Reza (Supervisor)
Abstract
This work describes the effect of hydroxyapatite with different morphology including nanorods and whisker on the properties of hydroxyapatite/polycaprolactone (HA/PCL) composite. Biodegradable polymer/Hydroxyapatite (HA) composites with the morphology of nanorods and whisker of (HA) as bone replacement scaffolds are synthesized by sol-gel and hydrothermal methods, respectively with a Ca/P ratio of 1.67 and 20:80 (HA/PCL).The crystallization behavior and porosity of HA/PCL composite are studied by scanning electron microscope and X-Ray diffraction. The response of bone marrow-derived human mesenchymal stem cells (hMSCs) in terms of cell proliferation and differentiation to the osteoblastic...
Loading of Drug and Nanostructured Coating on Dental Implant
, M.Sc. Thesis Sharif University of Technology ; Sadrnezhaad, Khatiboleslam (Supervisor)
Abstract
The aim of this project is to load analgesic drug; Paracetamol on dental implant. The implant is titanium alloy (Ti-6Al-4V). There are two kinds of samples of anodized and HA coated onto anodized. They are in the shape of the sheets in this study. The electrodeposition and anodization carried out in order to treat the two samples. Nanotubes were formed during anodic oxidation of the samples in the 1M Ammonium sulfate (NH₄)₂SO4 and 5wt% Ammonium fluoride NH4F electrolyte. They are expected to play role of carrier for the model drug; paracetamol. The results showed that HA anodized Ti-6-4 has the ability to hold higher amounts of drug and also can keep the drug for a longer time than the...
Preparation and Characterization of Hydroxyapatite Nanostructures Using Natural Resources for Bone Scaffold Applications
, M.Sc. Thesis Sharif University of Technology ; Simchi, Abdolreza (Supervisor) ; Askari, Masoud (Supervisor)
Abstract
This investigation presents synthesis and characterization of pure and monophasic hydroxyapatite (Ca10(PO4)6(OH)2; HA) Nanostructures prepared by coral and oyster shell powders heated at 800 oC for 8 h as precursor via precipitation method. The morphology of HA nanostructures was controlled in the presence of various surfactants such as SDS, CTAB and PVP. The HA Nanorods synthesized by SDS were applied to fabricate bone scaffolds. Particle sizes of the HA Nanoparticles were about 20-30 nm. Pours three-dimensional HA/Ge/CMC scaffolds cross-linked by citric and oxalic acids were synthesized. In order to increase the pore size of the scaffolds, NaCl with medium (180-250 µm) and large (420-500...
Chitosan/Gelatin/Mg Substituted Hydroxyapatite Nano Composite Scaffold for Bone Tissue Engineering
, M.Sc. Thesis Sharif University of Technology ; Mohammadi, Mohammad Reza (Supervisor) ; Fathi, Mohammad Hossein (Co-Advisor)
Abstract
The present study is work on fabrication and characterization of a chitosan/ gelatin/ Mg substituted hydroxyapatite nano composite scaffold for bone tissue engineering. At the first step pure and Mg-substituted hydroxyapatite (HA) (Ca10-xMgx(PO4) 6OH2) nano-hexagonal rods with 14–45 nmdiameter.for this, calcium nitrate, magnesium phosphate hydrate and potassium dihydrogenphosphate were used as precursors for Ca, Mg, and P, respectively. Calculated amounts of magnesium ions (Mg+2) especially from 0 to 8% (molar ratio) were incorporated as substituted into the calcium sol solution. Deionized water was used as a diluting media for HA sol preparation and ammonia was used to adjust the pH= 9....
Electrophoretic Deposition of Graphene Oxide Nanocomposite on Magnesium substrate Modified by PEO
, M.Sc. Thesis Sharif University of Technology ; Ghorbani, Mohammad (Supervisor)
Abstract
Plasma electrolyte oxidation process is one of the surface coating methods which is recommended to use as a surface preparation before applying the final coating on magnesium alloys due to its unique properties such as excellent adhesion.The aim of this study was to create an oxide layer on the AZ91 substrate and after optimizing the PEO coating conditions and choosing the best coating in order to increase adhesion and corrosion resistance, the composite coating of graphene oxide, hydroxyapatite and chitosan was applied by electrophoretic method. After studying the morphology of PEO oxide coating at current densities of 0.25, 0.35, 0.4, 0.5 and 0.6 amp/cm2 during times of 5 and 8 minutes, it...
Synthesis of One-Dimensional Nanoneedle-Like Arrays Hydroxyapatite for Bone Tissue Engineering Applications
, M.Sc. Thesis Sharif University of Technology ; Nemati, Ali (Supervisor) ; Khachatourian, Adrine Malek (Supervisor) ; Shokri, Babak (Co-Supervisor)
Abstract
Implant primary stability is a crucial component of implant survival. Primary mechanical stability is correlated with implant type, surgical technique, quantity and quality of bone at the recipient site. Since bone integration (BI) significance has been acknowledged, a variety of techniques have been developed to quicken BI and achieve faster fixation. Studies have shown that material type, and many surface properties, including as surface composition, roughness, topography, and energy, have a significant influence during the early stages of bone integration to the implant. In this work, we did synthesis one-dimensional nanoneedle-like arrays of hydroxyapatite using the injection method...
Preparation a Bio-Composite Scaffold Containing Hydroxyapatite/Silver Faunctionalized Graphene Oxide/Chitosan for Bone Tissue Engineering
, M.Sc. Thesis Sharif University of Technology ; Nemati, Ali (Supervisor) ; Malek Khachatourian, Adrineh (Supervisor)
Abstract
Bone scaffolds are used to regenerate bone tissue and accelerate bone healing, for this purpose, an attempt was made to prepare biocompatible, biodegradable, low toxicity and non-allergenic scaffolds to help increase osteogenesis and improve bone infections. A porous multi-component composite of chitosan, hydroxyapatite, graphene oxide functionalized with silver was made to make the desired scaffolds. At first, graphene oxide was functionalized by silver ions using silver nitrate. The structure of silver graphene oxide nanocomposite was confirmed by scanning electron microscope (SEM), Fourier infrared spectroscopy (FT-IR), and ultraviolet (UV-Visible) spectroscopy. In the next step, a...
Formulation and Investigation of Thermal Behavior and Flexural Properties of PMMA Denture base Reinforced with Modified Nanoparticles m-HAP and m-MWCNTs
, M.Sc. Thesis Sharif University of Technology ; Nemati, Ali (Supervisor) ; Malek Khachatourian, Adrineh (Supervisor)
Abstract
This study investigates the effect of adding hydroxyapatite nanoparticles and multi-walled carbon nanotubes in pure and modified form on the flexural properties and hardness of denture base Polymethyl Methacrylate. Polymethyl Methacrylate (PMMA) is still the most common denture base material. In fact, the mechanical properties of this resin have played a significant role in expanding its use in dentistry. But in the long-term use of resins, defects such as low resistance to crack growth, low flexural strength and brittleness can be seen. In fact, flexural fatigue occurs as a result of repeated flexural stresses, and it can be described as the main reason for crack growth and propagation in...
Preparation of Hydroxyapatite-Graphene Nano Composite Coating on Ti-6Al-4V Alloy Using Plasma Electrolyte Oxidation
, M.Sc. Thesis Sharif University of Technology ; Ghorbani, Mohammad (Supervisor)
Abstract
Hydroxyapatite-Graphene Nanocomposite coatings were formed on Ti-6Al-4V alloy by Plasma electrolytic oxidation. PEO electrolyte contains calcium acetate and calcium glycerophosphate. The effect of adding graphene to PEO electrolyte on the corrosion, mechanical, and biocompatibility properties of the coating investigated. Before adding graphene to the electrolyte, working parameters such as voltage, current density, process time were optimized using scanning electron microscopy (SEM), potentiodynamic polarization test, and thickness measurement. Examination of the coating morphology showed that due to thermal stresses, surface cracks formed at Voltages above 350 V. The results of the...
Formulation and Properties of Scaffolds based on Hydroxyapatite Composites Containing Titanium Dioxide and Magnesium Oxide
, M.Sc. Thesis Sharif University of Technology ; Nemati, Ali (Supervisor)
Abstract
This study investigates the effect of titanium dioxide and magnesium oxide additives on hydroxyapatite synthesized by sol-gel and composite with the predominant phase of hydroxyapatite by in situ method to improve mechanical properties. Scaffold samples were synthesized with nanometer-sized hydroxyapatite and composite powder particles by gel casting and sintered at 1200 ° C. Then, to evaluate the synthesized powders, simultaneous thermal analysis (STA), X-ray diffraction test, FTIR test, FESEM, EDS, and MAP analysis were used. Also, to evaluate the mechanical properties of the scaffolds, a compressive test was used, and to evaluate the scaffolds' density, the Archimedes method was used....
Studying the Effect of Zirconia & GNP on Mechanical, Tribological & Biological Properties of UHMWPE-HAp Nanocomposites used in Total Hip Joint Replacement
, M.Sc. Thesis Sharif University of Technology ; Bagheri, Reza (Supervisor) ; Faghihi Sani, Mohammad Ali (Supervisor)
Abstract
Medical engineering advances in total joint replacements and society’s rising demand for long lasting materials, have proven it essential to manufacture materials that are more similar to the original tissue in the fields of mechanical, tribological and biological properties. Ultra High Molecular Weight Polyethylene(UHMWPE), is a polymer widely used in arthroplasty applications due to its biocompatibility, chemical stability and proper mechanical properties. In this study, UHMWPE-HAp nanocomposites reinforced with Zirconia and Graphene were manufactured aiming to reach a structure that is more compatible with bone tissue and also to improve overall properties. First, using ultrasonication...
Synthesis of Antibacterial Hydroxyapatite/Titania-Silver Coating on Titanium Substrate Using Sol-Gel Method
, M.Sc. Thesis Sharif University of Technology ; Afshar, Abdollah (Supervisor)
Abstract
With the increase in the average age of the world's population, osteoporosis is a worldwide incidence. This disease, along with natural disasters, are important factors in the occurrence of fractures in various bones of the body. One of the methods for solving this problem and replacing with broken body bones is the use of metal implants with hydroxyapatite-based coatings. One of the common problems with using implants in the body is the infection in the adjacent parts of the implant. To overcome this problem, several studies have been carried out on the use of hydroxyapatite coatings with metal ions or antibacterial oxide compounds. In the present study, the influence of factors such as the...
Synthesis of Composite Coating with HA Nanoparticles on Ti by AC Plasma Electrolyte Oxidation
, M.Sc. Thesis Sharif University of Technology ; Ghorbani, Mohammad (Supervisor)
Abstract
In this project, a ceramic biocompatible coating was applied on Titanium which is included Hydroxyapatite by AC Plasma Electrolyte Oxidation method. First, coating was performed in 5 different solutions and various duration in 500mA/Cm2 as a current density. Then, by microscopic and macroscopic images and size of porosity and also thickness of coat, 3 solutions were chosen for adding nanoparticles: Solution 1 which includes NaH2PO4 and Ca(CH3COO)2 , Solution 3 which includes Ca(CH3COO)2 and Na-Beta G and Solution 4 which includes Ca(H2PO4)2, HMP, NA2(EDTA) and Ca(CH3COO)2 . Also the time 10 minutes was chose as a appropriate time. The average of the porosities size in solution 1 was about...
AC Anodizing of Pure Titanium Grade 2 with HA Nano Particle
, M.Sc. Thesis Sharif University of Technology ; Ghorbani, Mohammad (Supervisor)
Abstract
In this study, biocompatible ceramic coating, containing hydroxyapatite particles (HA), was successfully created by AC anodizing, on the surface of commercially pure titanium grades 2. Coating process basically consisted of three methods. In Method 1, samples were anodized in a salty electrolyte containing calcium – phosphate base and in method 2 samples were anodized as initial process, following cathodic polarisation deposition of HA particles. Finally in method 3, samples were anodized in an electrolyte containing of HA particles suspension.Parameters such as current density and time of anodizing process, in first procedure, and time of cathodic deposition process in second procedure, and...
Investigating Bio-Capability of HA-ZrO2-TiO2 Nano-Composite Coating by EPD on St. St 316 in Physiologic Solution
, M.Sc. Thesis Sharif University of Technology ; Afshar, Abdollah (Supervisor)
Abstract
Metallic implants are useful in dental and orthopedic applications. Bio coating is necessary to improve bio-compatibility and bio-activation of metallic implants. For this goal, HA is the most important material. In this research, the goal is to improve bio-compatibility of St. St 316 by coating HA, HA-ZrO2, HA-TiO2, HA-ZrO2-TiO2 using combination of electrodeposition and electrophoretic methods. To form HA, calcium and phosphor salt solution was used then ZrO2- TiO2 nanoparticles was added to solution. In order to analyst the coatings different tests were done. Thickness analysis, XRD, FT-IR, FE-SEM and EDS, bonding Strength, Polarization test, bio-compatibility and surface roughness...
Design and Manufacture of Nanostructured Hydroxyapatite coated Foamy core@compact Shell Ti-6Al-4V Nanocomposite
, M.Sc. Thesis Sharif University of Technology ; Sadrnezhad, Khatiboleslam (Supervisor)
Abstract
The main purpose of this research is design and manufacture of nanostructured hydroxyapatite-coated foamy core@compact shell Ti-6Al-4V bone-like composites for utilization as substitutive implant for cortical bone having porous core. The production procedure consist of two steps; (a) fabrication of foamy core@compact shell Ti-6Al-4V alloy using powder metallurgy-space holder technique, (b) precipitation of hydroxyapatite on the Ti-6Al-4V alloy specimens via pulse electrodeposition process. The bone-like structures were designed to reduce the stress shielding which ensures long-term stabilization of implants. It is while that, the hydroxyapatite coating improve the biological response of...
In Situ Synthesis of Nanorod Hydroxyapatite Reinforced Polycaprolactone Nanocomposite for Bone Tissue Engineering Application
, M.Sc. Thesis Sharif University of Technology ; Mohammadi, Mohammad Reza (Supervisor) ; Simchi, Abdol Reza (Supervisor)
Abstract
Hydroxyapatite is the most substantial inorganic constituent of bone tissue which displays splendid biocompability and bioactivity. Nevertheless, its mechanical properties is not utmost appropriate for a bone substitutes. Therefore, it is used to improve the mechanical properties of polymer matrix composite scaffolds. In the present work polycaprolactone as a polymeric matrix was employed to fabricate hydroxyapatite-polycaprolactone biocomposite scaffolds via in situ route. Solvothermal method was employed to synthesize in situ hydroxyapatite in polymer matrix. Porous scaffolds were fabricated via freeze-drying/porogen leaching. Physical, mechanical (compressive module and compressive...
Preparation and Characterization of HA/ZrO2 Biocomposite Coating on 316 Stainless Steel Fabricated by Electrodeposition
, M.Sc. Thesis Sharif University of Technology ; Afshar, Abdollah (Supervisor)
Abstract
In this research, role of zirconia nanoparticles as a biocompatible material which has great mechanical properties, was investigated on corrosion behavior and bonding strength of HA coating. HA- ZrO2 composite prepared by a 2-step pulse electrodeposition method. Effect of pH (3.5, 4.5), bath temperature (60, 80 ͦC), current density (0.5, 1, 2 mA/cm2) and zirconia concentration (5, 10, 15 g/L) on coating characteristics were studied. X-ray diffraction was employed for phase analysis. Morphology and microstructure of samples observed utilizing scanning electron microscope (SEM) and elemental analysis was done by EDS. In order to corrosion studies electrochemical impedance spectroscopy (EIS)...
Effect of Mullite Content on HAp-Mullite Composite for Hard Tissue Application
,
M.Sc. Thesis
Sharif University of Technology
;
Faghihi Sani, Mohammad Ali
(Supervisor)
;
Solati Hashjin, Mehran
(Supervisor)
Abstract
In this study effect of various mullite contents, as reinforcement phase, on phase combination, fracture surface and mechanical propertiese of hydroxyapatite- mullite composite has been investigated.
The used hydroxyapatite powder was synthesized through acid- base route and further calcination. XRD results demonstrated partially decomposition of HA in to β- TCP and CaO during the calcination. SEM image of the prepared HA powder showed that they were spherical and agglomarated.
The mixed HA with various amounts of the ball- milled mullite (10- 40 wt%)were pressed and sintered at 1350°C for 2h. Dominant phase in all composite samplese after sintering was Ca9Al(PO4)7.
Phase...
The used hydroxyapatite powder was synthesized through acid- base route and further calcination. XRD results demonstrated partially decomposition of HA in to β- TCP and CaO during the calcination. SEM image of the prepared HA powder showed that they were spherical and agglomarated.
The mixed HA with various amounts of the ball- milled mullite (10- 40 wt%)were pressed and sintered at 1350°C for 2h. Dominant phase in all composite samplese after sintering was Ca9Al(PO4)7.
Phase...
“ Nano Oxide Layer Forming on the Surface of Porous Nitinol Shape Memory Alloy for Improving Surface Properties “
, M.Sc. Thesis Sharif University of Technology ; Sadrnejhad, Khatiboleslam (Supervisor)
Abstract
In this project ,it has been done different surface treatment on 6 samples of nitinol with 40 % prosity,three of them are anodized by H2SO4 ,Hf, Acetic acid, one of them is treated with plasma spray with TIO2 powder, one of them is putted in the furnace at 700 degrees for an hour, and the last one is bare ; Moreover, these treated samples are putted in Simulated body fluid for 16 days . After this period of time, we analyzed the results. Then the cell adhesion amount of osteo blast cells (MG 63) is measured to these samples by immersing them for 3 days in these cells.The results are investigated by SEM ,XRD(X pertpro produced by Panalitical), XRF(530-XRF-01), AAS( AA240), Roughness measuring...