Loading...
Search for: dilatancy
0.006 seconds
Total 39 records

    Dilatational shear bands in rubber-modified isotactic polypropylene

    , Article Materials and Design ; Volume 25, Issue 3 , 2004 , Pages 247-250 ; 02613069 (ISSN) Zebarjad, S. M ; Bagheri, R ; Lazzeri, A ; Serajzadeh, S ; Sharif University of Technology
    Elsevier Ltd  2004
    Abstract
    The main goal of this study is to further understanding of the role of rubber particles on deformation mechanisms in PP/EPR blend. For doing this standard tensile specimens were produced using injection molding. The results of microscopic evaluation of tensile specimen after some stretching show that damage forms in some points and then propagates in different directions. Also some elongated voids are observed, those are probably formed due to cavitation of rubber particles or debonding at the interface. With regard to achieved micrographs one may conclude that the deformation mechanism in PP/EPR blend can be massive dilatational shear banding due to repeated cavitation. © 2003 Elsevier Ltd.... 

    Flow mediated dilation with photoplethysmography as a substitute for ultrasonic imaging

    , Article Physiological Measurement ; Volume 36, Issue 7 , 2015 , Pages 1551-1571 ; 09673334 (ISSN) Mashayekhi, G ; Zahedi, E ; Movahedian Attar, H ; Sharifi, F ; Sharif University of Technology
    Institute of Physics Publishing  2015
    Abstract
    Flow mediated dilation (FMD) is a non-invasive method for endothelial function assessment providing an index extracted from ultrasonic B-mode images. Although utilized in the research community, the difficulty of its application and high cost of ultrasonic devices prevent it from being widely used in clinical settings. In this study we show that substituting the ultrasonic device with more easily handled and low cost photoplethysmography and electrocardiography is possible. We introduce new indices based on the photoplethysmogram (PPG) and electrocardiogram (ECG) and show that they are correlated with the ultrasound-based FMD Index. To this end, a conventional ultrasound FMD test was carried... 

    Investigation of Stress-Dependence on Hydro-Mechanical Properties of Fractured Rocks

    , M.Sc. Thesis Sharif University of Technology Khazaie, Sina (Author) ; Goodarznia, Iraj (Supervisor)
    Abstract
    Fracture and Matrix permeability systematically change because production time of gas and oil reservoirs is very long and pore pressure, temperature and in-situ stresses continously change in reservoirs.This parameters have an important role in determination and development of wells according to the permeability distribution.The main factors in determination of fracture permeability values is normal and shear stiffness that parameters such as roughness, opening, closure, aperture and asperities influence this factor.In this thesis, we try to investigate the influence of this parameters on fracture permeability according to the normal and shear stresses.Also we want to investigate the... 

    Expansion Modeling of Coronary Stent for Selection of Optimized Stent

    , M.Sc. Thesis Sharif University of Technology Izadi Ramini, Elaheh (Author) ; Movahhedy, Mohammad Reza (Supervisor)
    Abstract
    Referring to mortality increasment having sprung from atherosclerosis, work on treatment of coronary heart disease seems to be necessary. Stent implementation is one of stenosis treatment. Stent deployment has been done during past two decades, but clinical evidence showed that because of some weakness in designing and implementing, restenosis occurs again. Material, structure and coating texture of stent are the designing criteria beside stent implementation importance. Thus a lot of activities have been done in this area to improve performance of these applications. Nowadays a lot of companies' researchers try the best to get better their products; consequently there is different types of... 

    An improved upper bound on dilation of regular polygons

    , Article Computational Geometry: Theory and Applications ; Volume 80 , 2019 , Pages 53-68 ; 09257721 (ISSN) Sattari, S ; Izadi, M ; Sharif University of Technology
    Elsevier B.V  2019
    Abstract
    Dilation of a set of points on the plane is the lowest possible dilation of a plane spanner on the point set. We show that dilation of vertices of any regular polygon is less than 1.4482. We introduce a method for constructing a triangulation of a regular polygon and prove this bound on its dilation. The upper bound on dilation is shown using mathematical proofs and experimental results. The new upper bound improves the previously known bound of 1.48454. © 2019 Elsevier B.V  

    Effect of dyslipidemia on a simple morphological feature extracted from photoplethysmography flow mediated dilation

    , Article International Conference in Electronic Engineering and Computing Technology, London, 1 July 2009 through 3 July 2009 ; Volume 60 LNEE , 2010 , Pages 551-561 ; 18761100 (ISSN) ; 9789048187751 (ISBN) Zaheditochai, M ; Zahedi, E ; Mohd Ali, M. A ; Sharif University of Technology
    2010
    Abstract
    Dyslipidemia is considered to be one of the main heart risk factors, affecting the endothelial vascular function, which can be non-invasively investigated by ultrasound flow-mediated dilation (US-FMD). However, US-FMD comes at a high-cost and is operator-dependent. In this paper, the effect of dyslipidemia on the photoplethysmogram (PPG) signal recorded from collateral index fingers is investigated following a previous study where it was shown that results similar to that of US-FMD can be replicated by the PPG. Two groups, consisting of 30 healthy subjects free from any risk factors and 30 subjects who have only dyslipidemia as risk factor were respectively considered. The percent change in... 

    Evaluation of endothelial response to reactive hyperaemia in peripheral arteries using a physiological model

    , Article International Journal of Biomedical Engineering and Technology ; Volume 33, Issue 4 , 2020 , Pages 305-324 Parsafar, M. H ; Zahedi, E ; Vahdat, B. V ; Sharif University of Technology
    Inderscience Publishers  2020
    Abstract
    Non-invasive measurement of flow-mediated dilation (FMD) in the brachial artery for assessing endothelial function is costly and operator-dependent, limiting its application to research cases. In this paper, an approach based on a physiological model between normalized central blood pressure and finger photoplethysmogram is presented. Baseline model parameters are estimated using a genetic algorithm in 30 subjects consisting of ten normal blood pressure (BP), ten high-BP and ten elderly volunteers. Beat-to-beat fitness values after reactive hyperaemia are calculated using baseline (before cuff occlusion) data. Results show that stimulus-induced changes are fairly described with a first order... 

    Meaurement of Flow Mediated Dilation Using Photoplethysmography

    , M.Sc. Thesis Sharif University of Technology Goldoozian, Layli Sadat (Author) ; Zahedi, Edmond (Supervisor)
    Abstract
    Endothelial cells cover the inner surface of blood vessels. In response to different physical (such as reactive hyperemia-RH) and pharmacological stimuli, they maintain homeostasis by changing the vascular diameter (by releasing chemical agents like nitric oxide). The endothelium inability to respond to metabolic need (endothelial dysfunction) is an early marker of cardiovascular diseases such as atherosclerosis. Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmographic (PPG) signal changes... 

    Prediction of Coronary Angiography Results by Flow Mediated Dilation Assessments with Photoplethysmography

    , M.Sc. Thesis Sharif University of Technology Hosseini, Zahra Sadat (Author) ; Zahedi, Edmond (Supervisor) ; Fakhrzadeh, Hossein (Supervisor)
    Abstract
    Cardio Vascular Diseases (CVD) is currently the most important cause of mortality in the world. Coronary artery disease (CAD-with 3 major epicardial vessels) is one of the significant CVD. Coronary angiography remains the gold standard for identifying the presence and absence of stenosis due to CAD. It is performed by inserting a catheter into the coronary artery, directly injecting radiopaque contrast material there and recording radiographic images in different view of arteries. Images of this invasive way show severity and area of stenosis.
    A sign of CAD is endothelial dysfunction (inner artery layer) in peripheral arteries like the brachial artery. Due to a significant correlation... 

    A robust zero-watermarking scheme using Canny edge detector

    , Article International Journal of Electronic Security and Digital Forensics ; Volume 5, Issue 1 , 2013 , Pages 25-44 ; 1751911X (ISSN) Shakeri, M ; Jamzad, M ; Sharif University of Technology
    2013
    Abstract
    By expansion of digital multimedia and networking technology, the problem of ownership protection has become increasingly important. Digital watermarking is an efficient way for copyright protection of digital images. Traditional watermarking techniques degrade the quality of host image by embedding a watermark logo. Facing this problem, a new watermarking approach called zero-watermarking has been proposed. In zero-watermarking methods, the watermark does not require to be embedded into the protected image but it uses both the watermark and the protected image to generate a verification map which is registered to a trusted authority for further protection. In this paper we propose a robust... 

    Upper bounds for minimum dilation triangulation in two special cases

    , Article Information Processing Letters ; Volume 133 , 2018 , Pages 33-38 ; 00200190 (ISSN) Sattari, S ; Izadi, M ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    Give a triangulation of a set of points on the plane, dilation of any two points is defined as the ratio between the length of the shortest path of these points and their Euclidean distance. Minimum dilation triangulation is a triangulation in which the maximum dilation between any pair of the points is minimized. We give upper bounds on the dilation of the minimum dilation triangulation for two kinds of point sets: An upper bound of nsin⁡(π/n)/2 for a centrally symmetric convex point set containing n points, and an upper bound of 1.19098 for a set of points on the boundary of a semicircle. © 2018 Elsevier B.V  

    Bacteria cell hydrophobicity and interfacial properties relationships: A new MEOR approach

    , Article Colloids and Interfaces ; Volume 5, Issue 4 , 2021 ; 25045377 (ISSN) Ganji Azad, E ; Javadi, A ; Jahanbani Veshareh, M ; Ayatollahi, S ; Miller, R ; Sharif University of Technology
    MDPI  2021
    Abstract
    For microbial enhanced oil recovery (MEOR), different mechanisms have been introduced. In some of these papers, the phenomena and mechanisms related to biosurfactants produced by certain microorganisms were discussed, while others studied the direct impacts of the properties of microorganisms on the related mechanisms. However, there are only very few papers dealing with the direct impacts of microorganisms on interfacial properties. In the present work, the interfacial properties of three bacteria MJ02 (Bacillus Subtilis type), MJ03 (Pseudomonas Aeruginosa type), and RAG1 (Acinetobacter Calcoaceticus type) with the hydrophobicity factors 2, 34, and 79% were studied, along with their direct... 

    Analyzing the Endothelial Function by Means of Photoplethysmogram Signal Modeling

    , M.Sc. Thesis Sharif University of Technology Amiri, Mina (Author) ; Zahedi, Edmond (Supervisor) ; Behnia, Fereidoon (Supervisor)
    Abstract
    The endothelial (the artery inner lumen cells) function is associated with cardiovascular risk factors. Its assessment methods can be classified into the two groups of invasive and noninvasive ones. The most widely used method among the current non-invasive tests employed in research settings is flow-mediated dilation (FMD). This technique measures endothelial function by inducing reactive hyperemia via the temporary arterial occlusion and measuring the resultant relative increase in the blood vessel diameter via ultrasound. The high price and large size of the device, and being operator dependent are the limitation of this method. In this work, we propose using the photoplethysmogram (PPG)... 

    Modeling the Endothelial Function in the Brachial Artery Using Photoplethysmography

    , M.Sc. Thesis Sharif University of Technology Mashayekhi, Ghoncheh (Author) ; Zahedi, Edmond (Supervisor) ; Jahed, Mehran (Supervisor)
    Abstract
    Flow Mediated Dilation (FMD) is a non-invasive method for endothelial function assessment providing an index extracted from ultrasonic B-mode images. Although utilized in the research community, the difficulty of its application and high cost of ultrasonic device prevent it from being widely used in clinical settings. In this study we show that substituting the ultrasonic device with more easily handled and low cost photoplethysmography and electrocardiography is possible. We introduce new indices based on the photoplethysmogram (PPG) and electrocardiogram (ECG) and show that they are correlated with the ultrasound-based FMD index. To this end, conventional ultrasound FMD test was carried... 

    Electrical analog model of arterial compliance during reactive hyperemia

    , Article 2011 1st Middle East Conference on Biomedical Engineering, MECBME 2011, 21 February 2011 through 24 February 2011, Sharjah ; 2011 , Pages 49-53 ; 9781424470006 (ISBN) Goldoozian, L. S ; Zahedi, E ; Sharif University of Technology
    2011
    Abstract
    Flow mediated dilation (FMD) measurement using ultrasound imaging (FMD-US) has been established as a standard method for assessing the endothelial function. Recently, a less skilled-operator demanding method has been proposed based on the photoplethysmogram (PPG) changes during reactive hyperemia. It was shown that the amplitude of the PPG pulse (FMD-PPG) changed in a quite similar manner to that of the artery diameter in the method of the FMD-US i.e. increases following releasing the cuff and then gradually returns to baseline. In this study PPG changes following reactive hyperaemia were modelled using time-varying passive electrical elements (R, L and C). The output of the electric analog... 

    Effect of microstructure on shear strength and dilatancy of unsaturated loess at high suctions

    , Article Canadian Geotechnical Journal ; Volume 57, Issue 2 , February , 2020 , Pages 221-235 Ng, C. W. W ; Sadeghi, H ; Jafarzadeh, F ; Sadeghi, M ; Zhou, C ; Baghbanrezvan, S ; Sharif University of Technology
    Canadian Science Publishing  2020
    Abstract
    To investigate the influences of microstructure changes on dilatancy of unsaturated loess at high suctions, a direct shear box device using the vapour equilibrium technique was used. Through conducting two series of direct shear tests on both intact and recompacted loess specimens and also investigating microstructural changes using the mercury intrusion porosim-etry (MIP) technique, a linear increase in dilatancy with suctions ranging from 8 to 230 MPa can be identified at different net stresses. The enhanced dilatancy observed is mainly attributed to desiccation-induced high suctions as the reduction in void ratio due to enhancement of suction was negligible. A macrovoid ratio, eM, may be... 

    Development of a Wrist PPG Probe for the Measurement of Radial Artery Diameter

    , M.Sc. Thesis Sharif University of Technology Keikhosravi, Adib (Author) ; Zahedi, Edmond (Supervisor)
    Abstract
    Inability of endothelial cells in responding to metabolic needs (endothelial dysfunction,) is a sign of heart diseases like atherosclerosis and vascular stenosis. Recently, a new method using finger PPG signal has been proposed to determine endothelial function in response to reactive hypertension (RH.) PPG-based endothelial function assessment results are not fully correlated with ultrasound FMD tests, and this is because of some auto-regulation phenomena in the fingertip. It is expected that such problems will not exist in larger arteries, like the radial artery. The goal of this project is to acquire the PPG signal from the radial artery as it is proportional to blood volume changes in... 

    Modeling the Relationship between Central Aortic Pressure and Radial Photoplethysmogram in Flow-mediated Dilation Test

    , Ph.D. Dissertation Sharif University of Technology Parsafar, Mohammad Habib (Author) ; Vosughi Vahdat, Bijan (Supervisor) ; Zahedi, Edmond (Supervisor)
    Abstract
    According to the World Health Organization, about 35% of deaths worldwide are due to cardiovascular diseases, therefore the evaluation of vascular endothelial function has great prognostic and diagnostic value for cardiovascular diseases. The conventional noninvasive method for endothelial function evaluation is the measurement of flow-mediated dilation in brachial artery using ultrasound imaging (FMD-US). As the accuracy of FMD-US depends on the operator's skill and the resolution of the ultrasound images, this method has not been adopted. In this work, we propose to use a low cost, easily-accessible surrogate signal, the photoplethysmogram (PPG) to implement the FMD test. Whereas previous... 

    A Micro-structural Study on Hydro-mechanical Behavior of Loess

    , Ph.D. Dissertation Sharif University of Technology Sadeghi, Hamed (Author) ; Jafarzadeh, Fardin (Supervisor) ; W. W. NG, Charles (Supervisor)
    Abstract
    Loess soil layers in semi-arid to arid areas have been deposited through the accumulation of aeolian sediments, resulted in a special metastable and open structure being usually unsaturated in nature. Since naturally occurred loess is widespread, it has been recently considered as a promising resource for constructing earth-fill structures. However, due to different microstructures of intact and recompacted loess, different responses to hydraulic and mechanical loading would be expected. Up to now, the hydro-mechanical behavior of loess from different perspectives has not been linked to its microstructural characteristics. The current research, therefore, aims to provide insight into the... 

    Discrimination of bilateral finger photoplethysmogram responses to reactive hyperemia in diabetic and healthy subjects using a differential vascular model framework

    , Article Physiological Measurement ; Volume 34, Issue 5 , 2013 , Pages 513-525 ; 09673334 (ISSN) Keikhosravi, A ; Aghajani, H ; Zahedi, E ; Sharif University of Technology
    2013
    Abstract
    Endothelial dysfunction assessment has received considerable attention due to its potential in early screening of cardiovascular diseases. Since the seminal work by Celermajer in flow-mediated dilation (FMD) based on B-mode ultrasound measurement of the brachial artery dilation following limb ischemia, many attempts have been made toward applying this method to clinical, non-invasive endothelial dysfunction assessment. One major obstacle toward achieving this objective has been the relative high cost of the required setup and skilled manpower. Such limitations have prompted the investigation of other non-invasively accessible signals such as the photoplethysmogram (PPG) in relation to FMD....