Experimental study of forced convection heat transfer from a cam shaped tube in cross flows

Nouri Borujerdi, A ; Sharif University of Technology | 2007

332 Viewed
  1. Type of Document: Article
  2. DOI: 10.1016/j.ijheatmasstransfer.2006.11.028
  3. Publisher: 2007
  4. Abstract:
  5. An experimental investigation has been conducted to clarify forced convection heat transfer characteristic and flow behavior of an isothermal cam shaped tube in cross flow. The range of angle of attack and Reynolds number based on an equivalent circular tube are within 0° < α < 180° and 1.5 × 104 < Reeq < 2.7 × 104, respectively. The results show that the mean heat transfer coefficient is a maximum at about α = 90° over the whole range of the Reynolds numbers. It is found that thermal hydraulic performance of the cam shaped tube is larger than that of a circular tube with the same surface area except for α = 90° and 120°. Furthermore, the effect of the diameter of the cam shaped tube upon the thermal hydraulic performance is discussed. © 2006
  6. Keywords:
  7. Cam shaped tube ; Cross flow ; Pressure drag ; Drag ; Flow patterns ; Forced convection ; Heat transfer coefficients ; Pipe flow ; Pressure effects ; Reynolds number
  8. Source: International Journal of Heat and Mass Transfer ; Volume 50, Issue 13-14 , 2007 , Pages 2605-2611 ; 00179310 (ISSN)
  9. URL: https://www.sciencedirect.com/science/article/abs/pii/S0017931006006594?via%3Dihub