    2-D Modeling of Blood Flow in Mitral Valve During its Closing and Opening

    , M.Sc. Thesis Sharif University of Technology Jamshidi, Hadi (Author) ; Firoozabadi, Bahar (Supervisor) ; Saeedi, Mohammad Saeed (Co-Supervisor)
    Abstract
    Problems with the mitral valve can make the heart less efficient at pumping blood around the body. Severe problems can lead to heart failure if the valve is not surgically repaired or replaced. A simple approximation of the heart geometry is used and the valve dimensions are based on reported measurements. The primary objective for this study is to design and simulate the opening and closing behavior of the mitral valve using 2D fluid-structure interaction (FSI) model using ADINA software in order to evaluate and investigate the hemodynamic performance and problems of mitral valve, in which the blood is described as a viscous incompressible fluid, and the mitral valve is described as an... 

    Simulation of the Influence of Hypertension on Low Density Lipoprotein (Ldl) Permeation into Multilayer Coronary Bifurcation

    , M.Sc. Thesis Sharif University of Technology Moniri Piri, Mohammad (Author) ; Firoozabadi, Bahar (Supervisor)
    Abstract
    Atherosclerosis, due to the penetration of low-density lipoprotein particles (LDL) into the arterial wall, is one of the most common and death-leading diseases in today's world. Due to its importance, extensive research has been conducted on the factors that affect this disease. In this thesis, a numerical study of the effects of Wall Shear Stress (WSS), non-Newtonian behavior of blood, different hematocrit values, and blood pressure on LDL permeation through the artery wall layers are investigated in a 4-layer wall model of a coronary bifurcation. To obtain the velocity and concentration fields in the domain, momentum, Brinkman, and mass transport equations are solved in the lumen and wall... 

    Development of an Integrated Hybrid Model of Human Cardiovascular and Respiratory System for Control Study purposes

    , M.Sc. Thesis Sharif University of Technology Kehtari, Payam (Author) ; Bozorgmehri, Ramin (Supervisor)
    Abstract
    Mathematical models are used for describing physical systems to make it possible to study and investigate the behavior of these systems and compare their performance and improve them. For this reason, a mathematical model for cardiovascular system and respiratory system is used to study how these two systems interact. The cardiovascular system model and the respiratory system model comprise four and two compartments, respectively. In fact, the combined model contains the left and right ventricles, body tissue, lung, systemic blood circulation, and pulmonary compartments. Heart rate and alveolar ventilation are assumed to be the quantities through them the central nervous system controls the... 

    Time Series Analysis Using Deep Neural Networks Based on DTW Kernels and its Application in Blood Pressure Estimation Using PPG Signals

    , M.Sc. Thesis Sharif University of Technology Ahmadi Mobarakeh, Mohammad (Author) ; Mohammadzadeh, Narjesolhoda (Supervisor)
    Abstract
    This work presents a modification of deep neural networks for time series analysis. We used kernel layer(s), as a novel approach, at the beginning of the common deep neural networks. These kernels learn based on dynamic time warping (DTW). In each kernel, DTW is calculated between the kernel value and a part of input time series or a part of last layer output (if the kernel is not in the first layer). DTW also gives an alignment path for the input series. This alignment path is used to defining a loss function with the goal of getting better alignment (lower DTW distance) between the kernel and the other input. Besides getting better accuracy on the examined datasets, the other achievement... 

    Blood Pressure Estimation from PPG Signal Using Dynamic Time Warping Based Methods

    , M.Sc. Thesis Sharif University of Technology Hajikazem, Helia (Author) ; Mohammadzade, Narjes alhoda (Supervisor) ; Behrozi, Hamid (Co-Supervisor)
    Abstract
    By continuously measuring blood pressure, we can prevent the irreversible effects of high blood pressure. With the traditional method of using a cuff, it is not possible to measure blood pressure continuously during the day, so for continuous monitoring of blood pressure, it is necessary to use a method without the need for a cuff. Based on previous studies, to estimate blood pressure, Photoplethysmogram and ECG signal features, or temporal and morphological features of Photoplethysmogram signal have been used. In methods that use ECG signals, signal recording is difficult, and methods that use both PPG and ECG signals are even more complex. Using only PPG signals also has its problems.... 

    Design and Implementation of Non-Invasive Blood Pressure Monitor for Smart Health Application

    , M.Sc. Thesis Sharif University of Technology Amini, Alireza (Author) ; Fakharzadeh Jahromi, Mohammad (Supervisor)
    Abstract
    The blood pressure (BP) is one of the most vital signs to monitor human health. Hypertension is a major public health problem that is associated with morbidity and mortality. In the past decades, the number of people with hypertension disease has been increased. According to Ministry of Health, 54 percent of hypertensive patients are unaware of this health threat. Therefore, accurate and continuous measurement of BP is essential for its prevention and treatment. Traditional non-invasive methods of BP monitoring use an inflatable cuff, which causes discomfort due to occlusion of the artery and can not be used continuously. Numerous studies have attempted to present methods without using a... 

    Non-invasive and Continuous Blood Pressure Measurement Using Pulse Transit Time without Cuff Requirement

    , M.Sc. Thesis Sharif University of Technology Esmaili Dastjerdi, Amir Hossein (Author) ; Shabany, Mahdi (Supervisor)
    Abstract
    This thesis addresses cuff-less blood pressure (BP) estimation, for systolic blood pressure (SBP) and diastolic blood pressure (DBP) estimation with the aid of the processing of vital signals. Both with and without calibration per person approaches for BP estimation are considered. A data acquisition hardware is designed for high-resolution sampling of phonocardiogram (PCG), Photoplethysmogram (PPG) and electrocardiogram (ECG). Using these signals, pulse transit time (PTT) and pulse arrival time (PAT) indexes, which would be used for BP estimation with calibration, are extracted. For the BP estimator model using the calibration, A nonlinear model based on PTT or PAT, via modeling the vessels... 

    Hardware Implementation of Wearable Cuff-less Blood Pressure Monitoring Module

    , M.Sc. Thesis Sharif University of Technology Kiani, Mohammad Mahdi (Author) ; Shabany, Mahdi (Supervisor) ; Mohammadzade, Hoda (Supervisor)
    Abstract
    Hypertension precvalence is 24 and 20.5 percent in men and women, respectively. Continuous Blood Pressure monitoring can provide invaluable information about individuals’ health conditions. However, BP is conventionally measured using inconvenient cuff-based instruments, which prevents continuous BP monitoring. This work presents an efficient algorithm, based on the Pulse Arrival Time (PAT), extracted from Electrocardiogram (ECG) and Photopletysmograph (PPG), for the continuous and cuff-less estimation of the Systolic Blood Pressure (SBP), Diastolic Blood Pressure (DBP), and Mean Arterial Pressure (MAP) values. Methods: The proposed framework estimates the BP values through processing vital... 

    Design of Efficient Algorithms for Cuff-less and Continuous Estimation of Blood Pressure in Smart Mobile Healthcare Systems

    , M.Sc. Thesis Sharif University of Technology Kachuee, Mohammad (Author) ; Shabany, Mahdi (Supervisor) ; Mohammadzadeh, Hoda (Co-Advisor)
    Abstract
    Continuous Blood Pressure monitoring can provide invaluable information about individuals’ health conditions. However, BP is conventionally measured using inconvenient cuff-based instruments, which prevents continuous BP monitoring. This work presents an efficient algorithm, based on the Pulse Arrival Time (PAT), for the continuous and cuff-less estimation of the Systolic Blood Pressure (SBP), Diastolic Blood Pressure (DBP), and Mean Arterial Pressure (MAP) values. The proposed framework estimates the BP values through processing vital signals and extracting two types of features, which are based on either physiological parameters or whole-based representation of vital signals. Finally, the... 

    Blood Pressure Measurement by using Pulse Transit Time

    , M.Sc. Thesis Sharif University of Technology Mazaheri, Samaneh (Author) ; Zahedi, Edmond (Supervisor) ; Jahed, Mehran (Supervisor)
    Abstract
    Continuous and non-invasive blood pressure (BP) measurement systems generally utilize applanation tonometry and vascular unloading. Some of them satisfies the AAMI standards (|mean|<5, |SD|<8). Unfortunately they are hardly to be widely affordable due to the complicated mechanical structure and high production cost. Till now those devices are seldom being used in operation room and generally used in clinical researches. In 2000, a linear model using pulse transit time (PTT) to continuous and non-invasive blood pressure (BP) measurement was proposed. Due to the nonlinear performance parameters of the arteries, researchers have used nonlinear models to promote this method. Although the... 

    , M.Sc. Thesis Sharif University of Technology Shoaran, Mahsa (Author) ; Atarodi, Mojtaba (Supervisor) ; Mehrany, Khashayar (Supervisor)
    Abstract
    In this thesis a novel passive method for integrated blood pressure monitoring in implantable applications has been proposed. The main constraints of such implantable systems are power consumption, area and simplicity of the implanted part and detected pressure is transmitted wirelessly to the external system and recorded. In this thesis an oscillator in 0.18um CMOS process has been proposed to detect the resonance frequency of the implanted tank circuit in the external unit of an implantable blood pressure monitoring system. Other designed circuits include a buffer, frequency detector, voltage to current converter and an 8 bit analog to digital converter. The system is capable of measuring... 

    Modeling Brachial Blood Pressure by Using Finger PPG Signal

    , M.Sc. Thesis Sharif University of Technology Asadpour, Abdoreza (Author) ; Zahedi, Edmond (Supervisor)
    Abstract
    Nowadays, all of the devices that measure blood pressure commercially at home are using wrist or arm cuffs preventing the systolic or diastolic blood pressure from being measured continuously. Various parameters such as blood flow with some degree of correlation with blood pressure that can be measured noninvasively have been suggested. However, these parameters do not produce accurate estimates for blood pressure. Pulse Transit Time (PTT) which is defined as the interval between the R peak of ECG signal and the next PPG signal valley has shown to have over 90% correlation with systolic blood pressure in past studies. In this thesis, the relationship between the value of the systolic blood... 

    Utility of a nonlinear joint dynamical framework to model a pair of coupled cardiovascular signals

    , Article IEEE Journal of Biomedical and Health Informatics ; Volume 17, Issue 4 , 2013 , Pages 881-890 ; 21682194 (ISSN) Sayadi, O ; Shamsollahi, M. B ; Sharif University of Technology
    2013
    Abstract
    We have recently proposed a correlated model to provide a Gaussian mixture representation of the cardiovascular signals, with promising results in identifying rhythm disturbances. The approach provides a transformation of the data into a set of integrable Gaussians distributed over time. Looking into the model from a new joint modeling perspective, it is capable of assembling a filtered estimation, and can be used to derive temporal information of the waveforms. In this paper, we present a step-by-step derivation of the joint model putting correlation assumptions together to conclude a minimal joint description for a pair of ECG-ABP signals. We then probe novel applications of this model,... 

    Validation of the Saadat NIBP module according to the ANSI/AAMI-SP10 protocol

    , Article 2013 20th Iranian Conference on Biomedical Engineering, ICBME 2013 ; Deembec , 2013 , Pages 199-202 Sadaghiani, M ; Mashayekhi, G ; Behzadfar, N ; Yaghoobzadeh, A ; Babaee, T ; Sharif University of Technology
    IEEE Computer Society  2013
    Abstract
    This study is conducted with the aim of validating the Saadat non-invasive blood pressure (NIBP) module accuracy and reliability against direct intra arterial pressure measurement (IBP) according to the ANSI/AAMI SP10-2002 guidelines. Measurement and comparison procedure were done in a static population of 19 adult patients with brachial catheterized arterial line with total measurements of 195 under supervision of a highly experienced cardiovascular anesthesiologist in accordance with the ANSI/AAMI SP10-2002 regulation. Data analysis was performed based on the protocol criteria. In order to represent relationships between the test device and the reference method, Bland-Altman graphical... 

    Mathematical modeling of heart rate and blood pressure variations due to changes in breathing pattern

    , Article 2013 20th Iranian Conference on Biomedical Engineering, ICBME 2013, Tehran, 18 December 2013 through 20 December 2013 ; 2013 , Pages 54-58 Goldoozian, L. S ; Zahedi, E ; Sharif University of Technology
    IEEE Computer Society  2013
    Abstract
    Analysis of the heart rate (HR) variation due to respiration, known as respiratory sinus arrhythmia (RSA), is a method to assess the autonomic nervous system (ANS) function. In this paper a physiologically-based mathematical model consisting of the cardiorespiratory system and ANS control has been used in order to study the cardiovascular response (mean arterial blood pressure and HR) to breathing with different respiration rates and tidal volumes. Simulation results show that RSA has its maximal amplitude at the respiration frequency of 0.12 Hz and that RSA amplitude varies linearly by tidal volume. These results are in agreement with real data from the literature. In addition, the... 

    Introducing an adaptive robust controller for artificial heart

    , Article Proceedings of the IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics, 24 June 2012 through 27 June 2012 ; June , 2012 , Pages 413-418 ; 21551774 (ISSN) ; 9781457711992 (ISBN) Ravanshadi, S ; Jahed, M ; Sharif University of Technology
    2012
    Abstract
    Prolonged and uncontrolled high shear stresses and turbulence can cause hemolysis, while alternating and low-level stresses may contribute to platelet activation and thrombus formation. Such deficiencies are reported for Total Artificial Heart (TAH) systems which are generally not fully capable of dynamic adaptation to sudden pressure and volume changes. This study introduces an adaptive robust controller for a linear motor based TAH (LMTAH) which overcomes such shortcomings. Proposed controller performance is compared with simulated natural heart in normal and stressed physiological conditions. Application of adaptive robust control results in flows with less stress variation and... 

    Life-threatening arrhythmia verification in ICU patients using the joint cardiovascular dynamical model and a bayesian filter

    , Article IEEE Transactions on Biomedical Engineering ; Volume 58, Issue 10 PART 1 , 2011 , Pages 2748-2757 ; 00189294 (ISSN) Sayadi, O ; Shamsollahi, M. B ; Sharif University of Technology
    Abstract
    In this paper, a novel nonlinear joint dynamical model is presented, which is based on a set of coupled ordinary differential equations of motion and a Gaussian mixture model representation of pulsatile cardiovascular (CV) signals. In the proposed framework, the joint interdependences of CV signals are incorporated by assuming a unique angular frequency that controls the limit cycle of the heart rate. Moreover, the time consequence of CV signals is controlled by the same phase parameter that results in the space dimensionality reduction. These joint equations together with linear assignments to observation are further used in the Kalman filter structure for estimation and tracking. Moreover,... 

    Prediction of acute hypotension episodes using Logistic Regression model and Support Vector Machine: A comparative study

    , Article 2011 19th Iranian Conference on Electrical Engineering, ICEE 2011, 17 May 2011 through 19 May 2011 ; May , 2011 , Page(s): 1 - 4 ; ISSN :21647054 ; 9789644634284 (ISBN) Janghorbani, A ; Arasteh, A ; Moradi, M. H ; Sharif University of Technology
    2011
    Abstract
    Acute hypotension episodes are one of the hemodynamic instabilities with high mortality rate that is frequent among many groups of patients. Prediction of acute hypotension episodes can help clinicians to diagnose the cause of this physiological disorder and select proper treatment based on this diagnosis. In this study new physiological time series are generated based on heart rate, systolic blood pressure, diastolic blood pressure and mean blood pressure time series. Statistical features of these time series are extracted and patients whom are exposed to acute hypotension episodes in future 1 hour time interval and whom are not, are classified based on these features and with the aid of... 

    Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time

    , Article Proceedings - IEEE International Symposium on Circuits and Systems, 24 May 2015 through 27 May 2015 ; Volume 2015-July , 2015 , Pages 1006-1009 ; 02714310 (ISSN) ; 9781479983919 (ISBN) Kachuee, M ; Kiani, M.M ; Mohammadzade, H ; Shabany, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    Recently a few methods have been proposed in the literature for non-invasive cuff-less estimation of systolic and diastolic blood pressures. One of the most prominent methods is to use the Pulse Transit Time (PTT). Although it is proven that PTT has a strong correlation with the systolic and diastolic blood pressures, this relation is highly dependent to each individuals physiological properties. Therefore, it requires per person calibration for accurate and reliable blood pressure estimation from PTT, which is a big drawback. To alleviate this issue, in this paper, a novel method is proposed for accurate and reliable estimation of blood pressure that is calibration-free. This goal is... 

    Definition and comparison of a new vascular index between young healthy and aged subjects

    , Article IECBES 2014, Conference Proceedings - 2014 IEEE Conference on Biomedical Engineering and Sciences: "Miri, Where Engineering in Medicine and Biology and Humanity Meet", 8 December 2014 through 10 December 2014 ; 2015 , Pages 911-915 ; 9781479940844 (ISBN) Jaafar, R ; Zahedi, E ; Mohd Ali, M. A ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2015
    Abstract
    In an effort to identify a useful noninvasive screening tool for cardiovascular diseases (CVD) screening, photoplethysmograph (PPG) signals were acquired and analyzed. These PPG signals were recorded during reactive hyperemia experiments consisting of a 4-minute blood flow blockage of the right arm (RA) brachial artery (BA) using a blood pressure cuff inflator. This procedure is usually done for the assessment of endothelial dysfunction which is a risk factor for developing CVD. In this study, signals of the infrared (IR) and red (R) LED's of the PPG sensor were analyzed. These signals were preprocessed, normalized and slow varying component of the signal (DC values) and the pulsatile...