Loading...
Search for: electrochemical-analysis
0.009 seconds
Total 47 records

    Comparison between electrochemical and photoelectrochemical detection of dopamine based on titania-ceria-graphene quantum dots nanocomposite

    , Article Biosensors and Bioelectronics ; Volume 151 , 2020 Ahmadi, N ; Bagherzadeh, M ; Nemati, A ; Sharif University of Technology
    Elsevier Ltd  2020
    Abstract
    In this study, titania-ceria-graphene quantum dot (TC-GQD) nanocomposite was synthesized by hydrothermal method for the first time. The prepared nanomaterials were characterized by XRD, FTIR dynamic light scattering (DLS), FESEM, HRTEM, and EDX spectroscopy along with elemental mapping. The synergistic effect of the nanocomposite components was studied by diffuse reflectance spectroscopy (DRS) and electrical conductivity meter. The results showed that band gap of TC-GQD nanocomposite was shifted to visible lights relative to its components (1.3 eV), and electrical conductivity of the sample was significant increased to 89.5 μS cm−1. After chemical and physical characterization, prepared new... 

    Voltammetric studies of Azathioprine on the surface of graphite electrode modified with graphene nanosheets decorated with Ag nanoparticles

    , Article Materials Science and Engineering C ; Volume 58 , 2016 , Pages 1098-1104 ; 09284931 (ISSN) Asadian, E ; Iraji Zad, A ; Shahrokhian, S ; Sharif University of Technology
    Elsevier Ltd 
    Abstract
    By using graphene nanosheets decorated with Ag nanoparticles (AgNPs-G) as an effective approach for the surface modification of pyrolytic graphite electrode (PGE), a sensing platform was fabricated for the sensitive voltammetric determination of Azathioprine (Aza). The prepared AgNPs-G nanosheets were characterized using transmission electron microscopy (TEM), X-ray diffraction (XRD), UV-vis and Raman spectroscopy techniques. The electrochemical behavior of Aza was investigated by means of cyclic voltammetry. Comparing to the bare PGE, a remarkable enhancement was observed in the response characteristics of Aza on the surface of the modified electrode (AgNPs-G/PGE) as well as a noticeable... 

    Imprinted silica nanofiber formation via sol-gel-electrospinning for selective micro solid phase extraction

    , Article New Journal of Chemistry ; Volume 42, Issue 16 , 2018 , Pages 13864-13872 ; 11440546 (ISSN) Asgari, S ; Bagheri, H ; Es Haghi, A ; Sharif University of Technology
    Royal Society of Chemistry  2018
    Abstract
    Sol composition and ripening conditions are two important parameters in silica fiber production through the conventional sol-gel process. In the current study, silica nanofibers were successfully obtained via the electrospinning technique, and sol-gel formation occurred during this process. Based on previous reports, with the aim of increasing the selectivity, we used the molecular imprinted methodology to produce a selective medium via sol-gel electrospinning. In this process, sol-gel was formed during electrospinning and then, the backbone polymer was removed by heating. To obtain a thin layer of silica nanofibers, the influencing parameters such as backbone polymer types, imprinting time... 

    Aniline-silica nanocomposite as a novel solid phase microextraction fiber coating

    , Article Journal of Chromatography A ; Volume 1238 , May , 2012 , Pages 22-29 ; 00219673 (ISSN) Bagheri, H ; Roostaie, A ; Sharif University of Technology
    2012
    Abstract
    A new unbreakable solid phase microextraction (SPME) fiber coating based on aniline-silica nanocomposite was electrodeposited on a stainless steel wire. The electropolymerization process was carried out at a constant deposition potential, applied to the corresponding aqueous electrolyte containing aniline and silica nanoparticles. The scanning electron microscopy (SEM) images showed the non-smooth and the porous surface structure of the prepared nanocomposite. The applicability of the new fiber coating was examined by headspace-solid phase microextraction (HS-SPME) of some environmentally important polycyclic aromatic hydrocarbons (PAHs), as model compounds, from aqueous samples.... 

    A polypyrrole-based sorptive microextraction coating for preconcentration of malathion from aquatic media

    , Article Chromatographia ; Volume 74, Issue 9-10 , 2011 , Pages 731-735 ; 00095893 (ISSN) Bagheri, H ; Aghakhani, A ; Ayazi, Z ; Khakinezhad, M ; Sharif University of Technology
    Abstract
    A new micro-solid phase extraction method was developed by combining solid-phase extraction and stir bar sorptive extraction to benefit from the advantages of both techniques. A polypyrrole coating was electrochemically synthesized on the surface of an already used graphite furnace, employed in electro-thermal atomic absorption spectroscopy. The cylindrical geometry of the graphite tube provided a rather huge surface area, suitable for sorptive extraction. The novel sorbent coating was examined as an extracting medium to isolate malathion. Effects of different parameters such as extraction time, salt concentration, sample volume, desorption solvent and time were investigated and optimized.... 

    Preparation of novel and highly active magnetic ternary structures (metal-organic framework/cobalt ferrite/graphene oxide) for effective visible-light-driven photocatalytic and photo-fenton-like degradation of organic contaminants

    , Article Journal of Colloid and Interface Science ; Volume 602 , 2021 , Pages 73-94 ; 00219797 (ISSN) Bagherzadeh, B ; Kazemeini, M ; Mahmoodi, N. M ; Sharif University of Technology
    Academic Press Inc  2021
    Abstract
    Herein, MIL-101(Fe), CoFe2O4, novel binary (MIL-101(Fe)/CoFe2O4, MIL-101(Fe)/GO and CoFe2O4/GO), and ternary (MIL-101(Fe)/CoFe2O4/(3%)GO and MIL-101(Fe)/CoFe2O4/(7%)GO) magnetic composites based upon the MIL-101(Fe) were synthesized. The XRD, FESEM, TEM, EDX, BET-BJH, FTIR, VSM, DRS, PL, EIS and other electrochemical analyses were applied to characterize samples. The MIL/CoFe2O4/(3%)GO demonstrated the best performance compared to other samples for visible light photocatalytic and photo-Fenton-like degradation of Direct Red 23 (DtR-23), Reactive Red 198 (ReR-198) dyes as well as Tetracycline Hydrochloride (TC-H) antibiotic. Degradation of dyes using the ternary composite after 70 min of... 

    Origin of apparent light-enhanced and negative capacitance in perovskite solar cells

    , Article Nature Communications ; Volume 10, Issue 1 , 2019 ; 20411723 (ISSN) Ebadi, F ; Taghavinia, N ; Mohammadpour, R ; Hagfeldt, A ; Tress, W ; Sharif University of Technology
    Nature Publishing Group  2019
    Abstract
    So-called negative capacitance seems to remain an obscure feature in the analysis of the frequency-dependent impedance of perovskite solar cells. It belongs to one of the puzzling peculiarities arising from the mixed ionic-electronic conductivity of this class of semiconductor. Here we show that apparently high capacitances in general (positive and negative) are not related to any capacitive feature in the sense of a corresponding charge accumulation. Instead, they are a natural consequence of slow transients mainly in forward current of the diode upon ion displacement when changing voltage. The transient current leads to a positive or negative ‘capacitance’ dependent on the sign of its... 

    Artificial neural network aided estimation of the electrochemical signals of monosaccharides on gold electrode

    , Article Carbohydrate Research ; Volume 343, Issue 8 , 2008 , Pages 1359-1365 ; 00086215 (ISSN) Gobal, F ; Sadeghpour Dilmaghani, A ; Sharif University of Technology
    2008
    Abstract
    Artificial neural networks were used to predict the oxidation peaks potentials of 7 monosaccharides under linear sweep voltammetry regime. Two sets of descriptors, one based on molecular properties calculated through DFT and another based on simple geometric distributions of hydroxyl groups and asymmetric carbon atoms along molecular chains, were employed to introduce the molecules to networks. Relatively, simple networks of (3,3,1) and (3,3,3,1) structures with the number of epochs not exceeding 15 through training process were capable of correctly predicting the peaks positions with R values in the range of 0.97-0.99. © 2008 Elsevier Ltd. All rights reserved  

    Gold nanorods for drug and gene delivery: An overview of recent advancements

    , Article Pharmaceutics ; Volume 14, Issue 3 , 2022 ; 19994923 (ISSN) Jahangiri Manesh, A ; Mousazadeh, M ; Taji, S ; Bahmani, A ; Zarepour, A ; Zarrabi, A ; Sharifi, E ; Azimzadeh, M ; Sharif University of Technology
    MDPI  2022
    Abstract
    Over the past few decades, gold nanomaterials have shown great promise in the field of nanotechnology, especially in medical and biological applications. They have become the most used nanomaterials in those fields due to their several advantageous. However, rod-shaped gold nanoparticles, or gold nanorods (GNRs), have some more unique physical, optical, and chemical properties, making them proper candidates for biomedical applications including drug/gene delivery, photothermal/photodynamic therapy, and theranostics. Most of their therapeutic applications are based on their ability for tunable heat generation upon exposure to near-infrared (NIR) radiation, which is helpful in both... 

    A selective chemiresistive sensor for the cancer-related volatile organic compound hexanal by using molecularly imprinted polymers and multiwalled carbon nanotubes

    , Article Microchimica Acta ; Volume 186, Issue 3 , 2019 ; 00263672 (ISSN) Janfaza, S ; Banan Nojavani, M ; Nikkhah, M ; Alizadeh, T ; Esfandiar, A ; Ganjali, M. R ; Sharif University of Technology
    Springer-Verlag Wien  2019
    Abstract
    A chemiresistive sensor is described for the lung cancer biomarker hexanal. A composite consisting of molecularly imprinted polymer nanoparticles and multiwalled carbon nanotubes was used in the sensor that is typically operated at a voltage of 4 V and is capable of selectively sensing gaseous hexanal at room temperature. It works in the 10 to 200 ppm concentration range and has a 10 ppm detection limit (at S/N = 3). The sensor signal recovers to a value close to its starting value without the need for heating even after exposure to relatively high levels of hexanal  

    Synthesis and electrochemical characterization of sol-gel-derived RuO 2/carbon nanotube composites

    , Article Journal of Solid State Electrochemistry ; Vol. 18, Issue 4 , April , 2014 , pp. 993-1003 ; Online ISSN: 1433-0768 Kahram, M ; Asnavandi, M ; Dolati, A ; Sharif University of Technology
    Abstract
    Ruthenium oxide was coated on multiwalled carbon nanotubes (MWCNTs) to obtain nanocomposite electrode which has a good response to the pH. To synthesize this electrode, gold and cobalt were coated on a stainless steel 304 substrates, respectively, and then, vertically aligned carbon nanotubes were grown on the prepared substrates by chemical vapor deposition. Gold reduced activity of the stainless steel, while cobalt served as a catalyst for growth of the carbon nanotube. Ruthenium oxide was then coated on MWCNTs via sol-gel method. At last, different techniques were used to characterize the properties of synthesized electrode including scanning electron microscopy (SEM), transmission... 

    Electrochemical determination of atorvastatin on nano-scaled polypyrrole film

    , Article Bioelectrochemistry ; Vol. 98 , 2014 , pp. 1-10 ; ISSN: 15675394 Kamalzadeh, Z ; Shahrokhian, S ; Sharif University of Technology
    Abstract
    Pyrrole was electro-polymerized on the surface of the glassy carbon electrode (GCE) coated with a thin film of carbon nanomaterials, including carbon nanotubes (CNTs), carbon nanoparticles (CNPs), nanodiamond-graphite (NDG) or graphite nanopowder (GNP). Morphology, thickness, stability and loading of the polypyrrole (PPY) film were significantly affected by the structure and morphology of the sub-layer of carbon nanomaterials. Electrochemical oxidation of atorvastatin (ATOR) was investigated. Under the optimized conditions, a significant increase in the peak current (compared to other modified electrodes and bare GCE) and a negative shift in the peak potential (compared to bare GCE) were... 

    Fabrication of porous gelatin-chitosan microcarriers and modeling of process parameters via the RSM method

    , Article International Journal of Biological Macromolecules ; Volume 88 , 2016 , Pages 288-295 ; 01418130 (ISSN) Karimian, S. A. M ; Mashayekhan, S ; Baniasadi, H ; Sharif University of Technology
    Elsevier B.V 
    Abstract
    Porous gelatin-chitosan microcarriers (MCs) with the size of 350 ± 50 μm were fabricated with blends of different gelatin/chitosan (G/C) weight ratio using an electrospraying technique. Response surface methodology (RSM) was used to study the quantitative influence of process parameters, including blend ratio, voltage, and syringe pump flow rate, on MCs diameter and density. In the following, MCs of the same diameter and different G/C weight ratio (1, 2, and 3) were fabricated and their porosity and biocompatibility were investigated via SEM images and MTT assay, respectively. The results showed that mesenchymal stem cells (MSCs) could attach, proliferate, and spread on fabricated porous MCs... 

    Mining the potential of label-free biosensors for in vitro antipsychotic drug screening

    , Article Biosensors ; Volume 8, Issue 1 , 2018 ; 20796374 (ISSN) Kilic, T ; Soler, M ; Fahimi Kashani, N ; Altug, H ; Carrara, S ; Sharif University of Technology
    MDPI AG  2018
    Abstract
    The pharmaceutical industry is facing enormous challenges due to high drug attribution rates. For the past decades, novel methods have been developed for safety and efficacy testing, as well as for improving early development stages. In vitro screening methods for drug-receptor binding are considered to be good alternatives for decreasing costs in the identification of drug candidates. However, these methods require lengthy and troublesome labeling steps. Biosensors hold great promise due to the fact that label-free detection schemes can be designed in an easy and low-cost manner. In this paper, for the first time in the literature, we aimed to compare the potential of label-free optical and... 

    Efficient protein immobilization on polyethersolfone electrospun nanofibrous membrane via covalent binding for biosensing applications

    , Article Materials Science and Engineering C ; Volume 58 , 2016 , Pages 586-594 ; 09284931 (ISSN) Mahmoudifard, M ; Soudi, S ; Soleimani, M ; Hosseinzadeh, S ; Esmaeili, E ; Vossoughi, M ; Sharif University of Technology
    Elsevier Ltd  2016
    Abstract
    In this paper we introduce novel strategy for antibody immobilization using high surface area electrospun nanofibrous membrane based on ethyl-3-(3-dimethylaminopropyl)-carbodiimide/N-hydroxysuccinimide (EDC/NHS) coupling chemistry. To present the high performance of proposed biosensors, anti-staphylococcus enterotoxin B (anti-SEB) was used as a model to demonstrate the utility of our proposed system. Polymer solution of polyethersolfone was used to fabricate fine nanofibrous membrane. Moreover, industrial polyvinylidene fluoride membrane and conventional microtiter plate were also used to compare the efficiency of antibody immobilization. Scanning electron microscopy images were taken to... 

    Sensitive determination of dopamine in the presence of uric acid and ascorbic acid using TiO2 nanotubes modified with Pd, Pt and Au nanoparticles

    , Article Analyst ; Volume 136, Issue 11 , 2011 , Pages 2322-2329 ; 00032654 (ISSN) Mahshid, S ; Li, C ; Mahshid, S. S ; Askari, M ; Dolati, A ; Yang, L ; Luo, S ; Cai, Q ; Sharif University of Technology
    2011
    Abstract
    A simple modified TiO2 nanotubes electrode was fabricated by electrodeposition of Pd, Pt and Au nanoparticles. The TiO2 nanotubes electrode was prepared using the anodizing method, followed by modifying Pd nanoparticles onto the tubes surface, offering a uniform conductive surface for electrodeposition of Pt and Au. The performance of the modified electrode was characterized by cyclic voltammetry and differential pulse voltammetry methods. The Au/Pt/Pd/TiO2 NTs modified electrode represented a high sensitivity towards individual detection of dopamine as well as simultaneous detection of dopamine and uric acid using 0.1 M phosphate buffer solution (pH 7.00) as the base solution. In both case,... 

    A novel enzyme based biosensor for catechol detection in water samples using artificial neural network

    , Article Biochemical Engineering Journal ; Volume 128 , 2017 , Pages 1-11 ; 1369703X (ISSN) Maleki, N ; Kashanian, S ; Maleki, E ; Nazari, M ; Sharif University of Technology
    Elsevier B.V  2017
    Abstract
    Biosensors could be used as digital devices to measure the sample infield. Consequently, computational programming along with experimental achievements are required. In this study, a novel biosensor/artificial neural network (ANN) integrated system was developed. Poly (3,4-ethylenedioxy-thiophene)(PEDOT), graphene oxide nano-sheets (GONs) and laccase (Lac) were used to construct a biosensor. The simple and one-pot process was accomplished by electropolymerizing 3,4-ethylenedioxy-thiophene (EDOT) along with GONs and Lac as dopants on glassy carbon electrode. Scanning electron microscopy (SEM) and electrochemical characterization were conducted to confirm successful enzyme entrapment. The... 

    Interpretation of the electrochemical response of a multi-population biofilm in a microfluidic microbial fuel cell using a comprehensive model

    , Article Bioelectrochemistry ; Volume 128 , 2019 , Pages 39-48 ; 15675394 (ISSN) Mardanpour, M. M ; Saadatmand, M ; Yaghmaei, S ; Sharif University of Technology
    Elsevier B.V  2019
    Abstract
    The present study investigates the diversification and dynamic behavior of a multi-population microfluidic microbial fuel cell (MFC) as a biosensor. The cost effective microfluidic MFC coupled to a comprehensive model, presents a novel platform for monitoring chemical and biological phenomena. The importance of competition among different microbial groups, hierarchical biochemical processes, bacterial chemotaxis and different mechanisms of electron transfer were significant considerations in the present model. The validation of the model using experimental data from a microfluidic MFC shows an appropriate match with the hierarchal biodegradation processes of a complex substrate as well as... 

    Three-dimensional hybrid of iron–titanium mixed oxide/nitrogen-doped graphene on Ni foam as a superior electrocatalyst for oxygen evolution reaction

    , Article Journal of Colloid and Interface Science ; Volume 563 , 15 March , 2020 , Pages 241-251 Mousavi, D. S ; Asen, P ; Shahrokhian, S ; Irajizad, A ; Sharif University of Technology
    Academic Press Inc  2020
    Abstract
    Growing demands for clean and renewable energy technologies have sparked broad research on the development of highly efficient and stable non-noble metal electrocatalysts for oxygen evolution reaction (OER). In this regard, in the present work a three-dimensional Fe2TiO5/nitrogen-doped graphene (denoted as 3D FTO/NG) hybrid electrocatalyst was synthesized via a facile in-situ process using a hydrothermal method. Structural characterization of the prepared nanocomposite is performed by various techniques e.g. field emission scanning electron microscopy (FE-SEM), atomic force microscopy (AFM) analysis, Fourier transform infrared spectra (FT-IR), X-ray photoelectron spectroscopy spectra (XPS),... 

    Optimization of solid-phase microextraction of volatile phenols in water by a polyaniline-coated Pt-fiber using experimental design

    , Article Analytica Chimica Acta ; Volume 581, Issue 1 , 2007 , Pages 71-77 ; 00032670 (ISSN) Mousavi, M ; Noroozian, E ; Jalali Heravi, M ; Mollahosseini, A ; Sharif University of Technology
    2007
    Abstract
    Solid-phase microextraction (SPME) coupled to gas chromatography (GC) was applied to the extraction of phenol and some of its volatile derivatives in water samples. The SPME fiber consisted of a thin layer of polyaniline, which was electrochemically coated on a fine Pt wire. The stability of the coating was such that it could be used at temperatures as high as 325 °C, without any deterioration. The effects of various parameters affecting the extraction efficiency were studied, simultaneously. From these, optimization of the extraction temperature, extraction time, coating thickness, sample pH, salt concentration and desorption time was carried out by means of a (26-2) fractional factorial...