Loading...
Search for: fluidic-devices
0.008 seconds
Total 64 records

    Treatment of the small time instability in the finite element analysis of fluid structure interaction problems

    , Article International Journal for Numerical Methods in Fluids ; Volume 71, Issue 6 , 2013 , Pages 756-771 ; 02712091 (ISSN) Afrasiab, H ; Movahhedy, M. R ; Sharif University of Technology
    2013
    Abstract
    In this paper, the fluid-structure interaction problem in mechanical systems in which a high frequency vibrating solid structure interacts with the surrounding fluid flow is considered. Such a situation normally appears in many microelectromechanical systems like a wide variety of microfluidic devices. A different implementation of the residual-based variational multiscale flow method is employed within the arbitrary Lagrangian-Eulerian formulation. The combination of the variational multiscale method with appropriate stabilization parameters is used to handle the so-called small time step instability in the finite element analysis of the fluid part in the coupled fluid-structure interaction... 

    Fluid-structure interaction analysis in microfluidic devices: A dimensionless finite element approach

    , Article International Journal for Numerical Methods in Fluids ; Volume 68, Issue 9 , 2012 , Pages 1073-1086 ; 02712091 (ISSN) Afrasiab, H ; Movahhedy, M. R ; Assempour, A ; Sharif University of Technology
    2012
    Abstract
    In this paper, the so-called small time-step instability in finite element simulation of the fluid part is considered in fluid-structure interaction (FSI) problems in which a high-frequency vibrating structure interacts with an incompressible fluid. Such a situation is common in many microfluid manipulating devices. A treatment has been proposed that uses the dimensionless set of FSI governing equations in order to scale up the problem time step to a proper level that precludes the potential small time-step instability. Two-dimensional and three-dimensional finite element simulations of a mechanical micropumping device are performed to verify the efficiency of the presented approach. Solid... 

    Computational study of geometric effects of bottom wall microgrooves on cell docking inside microfluidic devices

    , Article Journal of Mechanics in Medicine and Biology ; Volume 21, Issue 2 , 2021 ; 02195194 (ISSN) Ahandoust, S ; Saadatmand, M ; Sharif University of Technology
    World Scientific  2021
    Abstract
    Cells docking inside microfluidic devices is effective in studying cell biology, cell-based biosensing, as well as drug screening. Furthermore, single cell and regularly cells docking inside the microstructure of microfluidic systems are advantageous in different analyses of single cells exposed to equal drug concentration and mechanical stimulus. In this study, we investigated bottom wall microgrooves with semicircular and rectangular geometries with different sizes which are suitable for single cell docking along the length of the microgroove in x-direction and numerous cells docking regularly in one line inside the microgroove in a 3D microchannel. We used computational fluid dynamics to... 

    Computational study of geometric effects of bottom wall microgrooves on cell docking inside microfluidic devices

    , Article Journal of Mechanics in Medicine and Biology ; Volume 21, Issue 2 , 2021 ; 02195194 (ISSN) Ahandoust, S ; Saadatmand, M ; Sharif University of Technology
    World Scientific  2021
    Abstract
    Cells docking inside microfluidic devices is effective in studying cell biology, cell-based biosensing, as well as drug screening. Furthermore, single cell and regularly cells docking inside the microstructure of microfluidic systems are advantageous in different analyses of single cells exposed to equal drug concentration and mechanical stimulus. In this study, we investigated bottom wall microgrooves with semicircular and rectangular geometries with different sizes which are suitable for single cell docking along the length of the microgroove in x-direction and numerous cells docking regularly in one line inside the microgroove in a 3D microchannel. We used computational fluid dynamics to... 

    The effects of thymus plant extracts on single breast cancer cell morphology in the microfluidic channel

    , Article 2018 IEEE EMBS Conference on Biomedical Engineering and Sciences, IECBES 2018, 3 December 2018 through 6 December 2018 ; 2019 , Pages 647-651 ; 9781538624715 (ISBN) Ahmad, M. R ; Mansor, M. A ; Alsadat Rad, M ; Soo-Beng Khoo, A ; Ahmad, M ; Marzuki, M ; Physiological Measurement; Sarawak Convention Bureau ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2019
    Abstract
    Microfluidics based systems could be useful for drug discovery as they allow for miniaturization and could potentially be run as multiple parallel cell based assays. Such miniaturization allows assays at single cell level and reduces the amount of test material needed, which, in the case of natural product extracts, simplifies the preparation. Thyme species extracts have been reported to show some promising anti-cancer effects. In the present work, we used a microfluidics based system to study the effects of Thymus kotschyanusm Boiss plant extract on two human breast cancer cells lines which are MDA-MB-231 and MCF-7. For better understanding a single cancer cell death mechanism and a flow... 

    Particles focusing and separation by a novel inertial microfluidic device: divergent serpentine microchannel

    , Article Industrial and Engineering Chemistry Research ; Volume 61, Issue 38 , 2022 , Pages 14324-14333 ; 08885885 (ISSN) Amani, A ; Shamloo, A ; Vatani, P ; Ebrahimi, S ; Sharif University of Technology
    American Chemical Society  2022
    Abstract
    Microfluidic experiments have found wide applications in medical sciences and engineering, such as cell separation and focusing. In the present study, focusing and separation of particles with different sizes and densities were investigated by designing inertial microfluidic devices. The microfluidic channel is designed by analyzing the induced forces on the particles. In the designing process, the objective was to focus and separate the particles in the shortest length of the channel with the lowest possible cycles and high efficiency. The simulation is then used for analyzing the two proposed geometries to evaluate their particle separation and focusing ability, named convergent and... 

    Shear-thinning droplet formation inside a microfluidic T-junction under an electric field

    , Article Acta Mechanica ; Volume 232, Issue 7 , 2021 , Pages 2535-2554 ; 00015970 (ISSN) Amiri, N ; Honarmand, M ; Dizani, M ; Moosavi, A ; Kazemzadeh Hannani, S ; Sharif University of Technology
    Springer  2021
    Abstract
    Researchers usually simplify their simulations by considering the Newtonian fluid assumption in microfluidic devices. However, it is essential to study the behavior of real non-Newtonian fluids in such systems. Moreover, using the external electric or magnetic fields in these systems can be very beneficial for manipulating the droplet size. This study considers the simulation of the process of non-Newtonian droplets’ formation under the influence of an external electric field. The novelty of this study is the use of a shear-thinning fluid as the droplet phase in this process, which has been less studied despite its numerous applications. The effects of an external electric field on this... 

    Multiphysics analysis and practical implementation of a soft μ-actuator- based microfluidic micromixer

    , Article Journal of Microelectromechanical Systems ; Volume 29, Issue 2 , 2020 , Pages 268-276 Annabestani, M ; Azizmohseni, S ; Esmaeili Dokht, P ; Bagheri, N ; Aghassizadeh, A ; Fardmanesh, M ; Sharif University of Technology
    Institute of Electrical and Electronics Engineers Inc  2020
    Abstract
    Electroactive-Polymers (EAPs) are one of the best soft $mu $ -actuators with great biomedical applications. Ionic ones (i-EAPs) have more promising features and have adequate potential for using in the active microfluidic devices. Here, as a case study, we have designed and fabricated a microfluidic micromixer using an i-EAP named Ionic Polymer-Metal Composite (IPMC). In microfluidics, active devices have more functionality but due to their required facilities are less effective for Point of Care Tests (POCTs). In the direction of solving this paradox, we should use some active components that they need minimum facilities. IPMC can be one of these components, hence by integrating the IPMC... 

    Integrating hydrodynamic and acoustic cell separation in a hybrid microfluidic device: a numerical analysis

    , Article Acta Mechanica ; Volume 233, Issue 5 , 2022 , Pages 1881-1894 ; 00015970 (ISSN) Ashkezari, A. H. K ; Dizani, M ; Shamloo, A ; Sharif University of Technology
    Springer  2022
    Abstract
    Cell separation microfluidic devices have evolved into a multitude of biomedical and clinical research. Nonetheless, many critical issues remain in the way of achieving an excellent separation of target cells from a heterogeneous sample. Parallel to the abundant experimental studies related to the hybrid microfluidic methods, it is easy to perceive the lack of numerical investigations in order to optimize the separation process and its accuracy. In this study, for the first time to the best of our knowledge, a hybrid system by integrating acoustophoresis and pinched-flow fractionation (PFF) is proposed to achieve a viable system for a wide-range, precise separation. Employing the ultrasound... 

    Production of uniform size cell-enclosing silk derivative vehicles through coaxial microfluidic device and horseradish crosslinking reaction

    , Article European Polymer Journal ; Volume 172 , 2022 ; 00143057 (ISSN) Badali, E ; Hosseini, M ; Varaa, N ; Mahmoodi, N ; Goodarzi, A ; Taghdiri Nooshabadi, V ; Hassanzadeh, S ; Arabpour, Z ; Khanmohammadi, M ; Sharif University of Technology
    Elsevier Ltd  2022
    Abstract
    Silk fibroin (SF) as a natural biopolymer holds great potential in biomedical research because of its biocompatibility, easy processability and high strength properties. However, slow gelation time has narrowed its applications, specifically in cell-laden microparticle production due to insufficient crosslinkable moieties. This study aimed to develop cell-laden silk fibroin-phenol (SF-Ph) microparticle through co-flow microfluidic system using SF conjugated Ph moieties whereas covalent crosslinking is mediated with horseradish peroxidase (HRP) in the presence of hydrogen peroxide (H2O2). For this, the SF-Ph was synthesized through carbodiimide condensation crosslinking reaction. Aqueous... 

    Toward a comprehensive microextraction/determination unit: A chip silicon rubber polyaniline-based system and its direct coupling with gas chromatography and mass spectrometry

    , Article Journal of Separation Science ; Volume 39, Issue 21 , 2016 , Pages 4227-4233 ; 16159306 (ISSN) Bagheri, H ; Allahdadlalouni, M ; Zamani, C ; Sharif University of Technology
    Wiley-VCH Verlag  2016
    Abstract
    An inexpensive silicon rubber-based chip was constructed by fabricating a triangle-shaped microcanal with a 135 μm width and 234 μm depth by laser ablation technique. The fabricated groove was sealed by a thin glass cover while two pieces of stainless-steel tubing were connected to each side of the canal. Then, a thin polyaniline film was synthesized on the walls of the canal by chemical oxidation using a syringe pump to deliver the relevant reagents. The microfluidic system was eventually connected to a gas chromatography-mass spectrometry. To evaluate the capability of the constructed microfluidic system, it was implemented to the analysis of submilliliter volumes of environmental samples... 

    Numerical simulation of the behavior of toroidal and spheroidal multicellular aggregates in microfluidic devices with microwell and U-shaped barrier

    , Article Micromachines ; Volume 8, Issue 12 , 2017 ; 2072666X (ISSN) Barisam, M ; Saidi, M. S ; Kashaninejad, N ; Vadivelu, R ; Nguyen, N. T ; Sharif University of Technology
    Abstract
    A microfluidic system provides an excellent platform for cellular studies. Most importantly, a three-dimensional (3D) cell culture model reconstructs more accurately the in vivo microenvironment of tissue. Accordingly, microfluidic 3D cell culture devices could be ideal candidates for in vitro cell culture platforms. In this paper, two types of 3D cellular aggregates, i.e., toroid and spheroid, are numerically studied. The studies are carried out for microfluidic systems containing U-shaped barrier as well as microwell structure. For the first time, we obtain oxygen and glucose concentration distributions inside a toroid aggregate as well as the shear stress on its surface and compare its... 

    A comparison of different geometrical elements to model fluid wicking in paper-based microfluidic devices

    , Article AIChE Journal ; Volume 66, Issue 1 , 2020 Boodaghi, M ; Shamloo, A ; Sharif University of Technology
    John Wiley and Sons Inc  2020
    Abstract
    Recently, microfluidic paper-based analytical devices (μPADs) have outstripped polymeric microfluidic devices in the ease of fabrication and simplicity. Surface tension-based fluid motion in the paper's porous structure has made the paper a suitable substrate for multiple biological assays by directing fluid into multiple assay zones. The widespread assumption in most works for modeling wicking in a paper is that the paper is a combination of capillaries with the same diameter equal to the effective pore diameter. Although assuming paper as a bundle of capillaries gives a good insight into pressure force that drives the fluid inside the paper, there are some difficulties using the effective... 

    Ion-pair extraction-reaction of calcium using Y-shaped microfluidic junctions: An optimized separation approach

    , Article Chemical Engineering Journal ; Volume 334 , 2018 , Pages 2603-2615 ; 13858947 (ISSN) Foroozan Jahromi, P ; Karimi Sabet, J ; Amini, Y ; Sharif University of Technology
    Elsevier B.V  2018
    Abstract
    In this research, a continuous microsolvent extraction-reaction was developed for the efficient separation of calcium ion. This study gives a preliminary possible practical application of microfluidic devices in chemical exchange reaction for enrichment of 48Ca stable isotope. For this purpose, in the first stage, the hydrodynamic behavior of two immiscible liquids in a simple Y-shaped microfluidic junction is experimentally investigated, and then ion-pair extraction-reaction of Ca2+ using picric acid as a counter-ion and dicyclohexano-18-crown-6 (DC18C6) as a lipophilic ionophore is studied in this microfluidic and conventional batch method. The impact of main process parameters, including... 

    Novel microfluidic graphene oxide–protein amperometric biosensor for detecting sulfur compounds

    , Article Biotechnology and Applied Biochemistry ; Volume 66, Issue 3 , 2019 , Pages 353-360 ; 08854513 (ISSN) Ghaemi, A ; Abdi, K ; Javadi, S ; Shehneh, M. Z ; Yazdian, F ; Omidi, M ; Rashedi, H ; Haghiralsadat, B. F ; Asayeshnaeini, O ; Sharif University of Technology
    Wiley-Blackwell Publishing Ltd  2019
    Abstract
    Sulfur compounds are essential for many industries and organisms; however, they cause serious respiratory problems in human beings. Therefore, determination of sulfur concentration is of paramount importance. The research approach in the field of detecting contaminants has led to smaller systems that provide faster and more effective ways for diagnosis purposes. In this study, a novel portable amperometric graphene oxide–protein biosensor platform is investigated. The main characteristic of this structure is the implementation of a microfluidic configuration. With albumin metalloprotein as the biorecognition element, graphene oxide was synthesized and characterized by transmission electron... 

    Carbon nanotubes in microfluidic lab-on-a-chip technology: current trends and future perspectives

    , Article Microfluidics and Nanofluidics ; Volume 21, Issue 9 , 2017 ; 16134982 (ISSN) Ghasemi, A ; Amiri, H ; Zare, H ; Masroor, M ; Hasanzadeh, A ; Beyzavi, A ; Aref, A. R ; Karimi, M ; Hamblin, M. R ; Sharif University of Technology
    Abstract
    Advanced nanomaterials such as carbon nanotubes (CNTs) display unprecedented properties such as strength, electrical conductance, thermal stability, and intriguing optical properties. These properties of CNT allow construction of small microfluidic devices leading to miniaturization of analyses previously conducted on a laboratory bench. With dimensions of only millimeters to a few square centimeters, these devices are called lab-on-a-chip (LOC). A LOC device requires a multidisciplinary contribution from different fields and offers automation, portability, and high-throughput screening along with a significant reduction in reagent consumption. Today, CNT can play a vital role in many parts... 

    Microfluidic devices with gold thin film channels for chemical and biomedical applications: a review

    , Article Biomedical Microdevices ; Volume 21, Issue 4 , 2019 ; 13872176 (ISSN) Ghasemi Toudeshkchoui, M ; Rabiee, N ; Rabiee, M ; Bagherzadeh, M ; Tahriri, M ; Tayebi, L ; Hamblin, M. R ; Sharif University of Technology
    Springer New York LLC  2019
    Abstract
    Microfluidic systems (MFS) provide a range of advantages in biomedical applications, including improved controllability of material characteristics and lower consumption of reagents, energy, time and money. Fabrication of MFS employs various materials, such as glass, silicon, ceramics, paper, and metals such as gold, copper, aluminum, chromium and titanium. In this review, gold thin film microfluidic channels (GTFMFC) are discussed with reference to fabrication methods and their diverse use in chemical and biomedical applications. The advantages of gold thin films (GTF) include flexibility, ease of manufacture, adhesion to polymer surfaces, chemical stability, good electrical conductivity,... 

    Secondary flows, mixing, and chemical reaction analysis of droplet-based flow inside serpentine microchannels with different cross sections

    , Article Langmuir ; Volume 37, Issue 17 , 2021 , Pages 5118-5130 ; 07437463 (ISSN) Ghazimirsaeed, E ; Madadelahi, M ; Dizani, M ; Shamloo, A ; Sharif University of Technology
    American Chemical Society  2021
    Abstract
    Chemical bioreactions are an important aspect of many recent microfluidic devices, and their applications in biomedical science have been growing worldwide. Droplet-based microreactors are among the attractive types of unit operations, which utilize droplets for enhancement in both mixing and chemical reactions. In the present study, a finite-volume-method (FVM) numerical investigation is conducted based on the volume-of-fluid (VOF) applying for the droplet-based flows. This multiphase computational modeling is used for the study of the chemical reaction and mixing phenomenon inside a serpentine microchannel and explores the effects of the aspect ratio (i.e., AR = height/width) of... 

    Silane–based modified papers and their extractive phase roles in a microfluidic platform

    , Article Analytica Chimica Acta ; Volume 1128 , 2020 , Pages 31-41 Hashemi Hedeshi, M ; Rezvani, O ; Bagheri, H ; Sharif University of Technology
    Elsevier B.V  2020
    Abstract
    Herein, some (modified) paper–based substrates were prepared and utilized as extractive phases in a microfluidic device and their extraction performances examined for analytes with different polarities. Reagents including hexadecyltrimethoxysilane (HDTMS), phenyltrimethoxysilane (PTES), (3-aminopropyl) triethoxysilane (APTES) and 3–(2,3–epoxypropoxy) propyltrimethoxysilane (EPPTMOS) were implemented for the modification process. Due to the induction of different silane functional groups, it was anticipated to have various interactions for the tested analytes. Eventually, the prepared paper sheets were used as extractive phases for solid–phase extraction within a microfluidic system. The... 

    Computational study of an integrated microfluidic device for active separation of RBCs and cell lysis

    , Article Chemical Engineering and Processing - Process Intensification ; Volume 174 , 2022 ; 02552701 (ISSN) Jalilvand, E ; Shamloo, A ; Gangaraj, M. H ; Sharif University of Technology
    Elsevier B.V  2022
    Abstract
    Separation and lysis of RBCs play an important role in diagnosis of different diseases. Although they have been partially studied in several researches, a comprehensive study on integrating both separation and lysis units on a single chip has been seen rarely in the literature. Also, the factors related to the chemical lysis process have not been investigated in detail. In this study, we introduce a novel microfluidic channel design for sequential RBC's separation and lysis. For the separation part, an active method with an electric field was applied to the cells. Besides, a novel mixer was designed for mixing the cell solution and lysis reagent. In the lysis section, we used a mathematical...